Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 73
Filtrar
1.
Nat Genet ; 21(4): 370-8, 1999 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-10192386

RESUMO

The immunogenetic basis of severe infections caused by bacille Calmette-Guérin vaccine and environmental mycobacteria in humans remains largely unknown. We describe 18 patients from several generations of 12 unrelated families who were heterozygous for 1 to 5 overlapping IFNGR1 frameshift small deletions and a wild-type IFNGR1 allele. There were 12 independent mutation events at a single mutation site, defining a small deletion hotspot. Neighbouring sequence analysis favours a small deletion model of slipped mispairing events during replication. The mutant alleles encode cell-surface IFNgamma receptors that lack the intra-cytoplasmic domain, which, through a combination of impaired recycling, abrogated signalling and normal binding to IFNgamma exert a dominant-negative effect. We thus report a hotspot for human IFNGR1 small deletions that confer dominant susceptibility to infections caused by poorly virulent mycobacteria.


Assuntos
Predisposição Genética para Doença/genética , Infecções por Mycobacterium/imunologia , Receptores de Interferon/genética , Deleção de Sequência , Adolescente , Adulto , Linfócitos B/efeitos dos fármacos , Linfócitos B/metabolismo , Vacina BCG/efeitos adversos , Vacina BCG/uso terapêutico , Proteínas de Ligação a DNA/metabolismo , Feminino , Fibroblastos/efeitos dos fármacos , Fibroblastos/imunologia , Expressão Gênica , Predisposição Genética para Doença/imunologia , Heterozigoto , Humanos , Interferon gama/farmacologia , Masculino , Mycobacterium/patogenicidade , Infecções por Mycobacterium/genética , Linhagem , RNA Mensageiro/metabolismo , Receptores de Interferon/metabolismo , Fator de Transcrição STAT1 , Transativadores/metabolismo , Transfecção , Receptor de Interferon gama
2.
J Environ Radioact ; 99(7): 1149-53, 2008 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-18342413

RESUMO

Thermoluminescence dosimetry has been used to measure air kerma in 29 sites in Sicily. Four three month measurement campaigns have been carried out in order to assess seasonal variations. Average annual values between 20 and 90 nGy h(-1), after cosmic background subtraction, are reported. Average annual values are strongly dependent on site lithology, and we find that winter data are generally the highest, while spring and autumn rates are generally the lowest with very similar trends in any site. Summer values generally lay in between. Largest seasonal variations are found in sites along the southern coast of the island, probably because of stronger action of winds affecting radon, along with its progeny, concentrations at ground level.


Assuntos
Poluentes Radioativos do Ar/análise , Monitoramento de Radiação/métodos , Estações do Ano , Geografia , Sicília , Espectrometria gama
3.
Phys Med Biol ; 52(17): 5219-30, 2007 Sep 07.
Artigo em Inglês | MEDLINE | ID: mdl-17762082

RESUMO

In this paper, the addition of gadolinium is proposed as a useful tool to enhance the electron spin resonance (ESR) sensitivity of organic compounds to thermal neutrons. The target of this work is the detection, through the ESR technique, of the thermal neutron fluence in a mixed field of photons and neutrons. Gadolinium was chosen because it has a very high capture cross section to thermal neutrons; its nuclear reaction with thermal neutrons induces complex inner shell transitions that generate, besides other particles, Auger electrons, which in turn release their energy in the neighborhood (only several nanometers) of the place of reaction. Gadolinium was added to two organic molecules: alanine and ammonium tartrate. The main result obtained was a greater neutron sensitivity for dosimeters with gadolinium than for those without gadolinium for both organic molecules used. Since a dosimeter pair is required to discriminate between the two components of a mixed field, we studied the response of each dosimeter pair irradiated in a mixed field. Through a blind test we verified the usefulness of this dosimetric system and we obtained an estimate of the fluence in the mixed field with a relative uncertainty of 3%, when the pair composed of an alanine dosimeter and a dosimeter with alanine and gadolinium is used.


Assuntos
Espectroscopia de Ressonância de Spin Eletrônica/métodos , Gadolínio/química , Gadolínio/efeitos da radiação , Radiometria/métodos , Temperatura Alta , Nêutrons , Doses de Radiação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
4.
Appl Radiat Isot ; 65(4): 435-9, 2007 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-17158056

RESUMO

ESR response to gamma-irradiation (1-50 Gy) of blends containing alanine and either B(OH)(3) or Gd(2)O(3) is reported. The sensitivity of the alanine--B(OH)(3) blend is comparable to the sensitivity of pure alanine, although its lowest detectable dose, LDD, is smaller ( approximately 1.3 Gy) than that of pure alanine ( approximately 2.9 Gy). Alanine with Gd(2)O(3) is about two times more sensitive than pure alanine, and its LDD is 0.8 Gy. The better sensitivity and LDD are probably due to the high atomic number (Z=64) of gadolinium, which enhances the interaction probability with photons and, consequently, the radical yield. This study suggests that other high-Z atoms may be useful for increasing the sensitivity of the response of alanine to gamma-radiation.


Assuntos
Alanina/efeitos da radiação , Ácidos Bóricos/efeitos da radiação , Espectroscopia de Ressonância de Spin Eletrônica/métodos , Raios gama , Radiometria/métodos , Boro , Gadolínio/efeitos da radiação , Isótopos
5.
Radiat Prot Dosimetry ; 126(1-4): 333-6, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17502321

RESUMO

The glow curves of thermoluminescent dosimeters (TLD600, TLD700 and MCP), exposed to a mixed field of thermal neutrons and gamma photons are analysed. The fluence values of thermal neutrons used, comparable with those used in radiotherapy, allow one to define the reliability of the TLDs, in particular the most sensitive MCP, in this radiation field and to get information on the dose absorbed values. The glow curves obtained have been deconvoluted using general order kinetics and the observed differences for the different LET components have been analysed. In particular, the ratio of the n(0) parameter of two different peaks seems to allow to discriminate the different contributions of neutrons and gamma photons in the beam.


Assuntos
Desenho Assistido por Computador , Modelos Teóricos , Nêutrons , Proteção Radiológica/instrumentação , Dosimetria Termoluminescente/instrumentação , Simulação por Computador , Desenho de Equipamento , Análise de Falha de Equipamento , Temperatura Alta , Doses de Radiação , Proteção Radiológica/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Dosimetria Termoluminescente/métodos
6.
Radiat Prot Dosimetry ; 126(1-4): 631-5, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17517673

RESUMO

In this paper, the results of a study on the electron spin resonance (ESR) dosimetry to measure thermal neutron fluence in a mixed radiation field (neutron and photons) are presented. The ESR responses of alanine dosemeters with different additives are compared. In particular, the (10)B-acid boric and the Gd-oxide were chosen to enhance the sensitivity of alanine dosemeters to thermal neutrons. Irradiations were carried out inside the thermal column of the TAPIRO reactor of the ENEA center, Casaccia Rome. The main results are a greater neutron sensitivity and a smaller lowest detectable fluence for the dosemeters with gadolinium than for dosemeters of alanine with (10)B, which is well known to be much more sensitive to thermal neutrons than simple alanine.


Assuntos
Alanina/química , Alanina/efeitos da radiação , Espectroscopia de Ressonância de Spin Eletrônica/instrumentação , Nêutrons , Monitoramento de Radiação/instrumentação , Proteção Radiológica/instrumentação , Calibragem , Espectroscopia de Ressonância de Spin Eletrônica/métodos , Desenho de Equipamento , Análise de Falha de Equipamento , Teste de Materiais , Doses de Radiação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
7.
Physiol Meas ; 27(9): 881-99, 2006 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-16868353

RESUMO

The a-wave is one of the main issues of research in the field of ocular electrophysiology, since it is strictly connected with early photoreceptoral activities. The present study proposes mathematical methods that analyse this component in human subjects, and supports experimental evidence relating to possible correlations among the responses of photoreceptoral units under a light stimulus. The investigation is organized in two parts: the first part concerns the onset and the initial slope, up to the first minimum (about 10-15 ms), the second part deals with the main portion of the wave, up to about 30 ms. In both cases, the a-waves, recorded at various levels of luminance, have been fitted with a set of appropriate functions representing possible models of physiological behaviour which would take place in the early stages of phototransduction. The statistical nature of the underlying processes is also discussed. The results indicate that correlations occur in the early stages, whereas random processes are set up later.


Assuntos
Algoritmos , Diagnóstico por Computador/métodos , Eletrorretinografia/métodos , Eletrorretinografia/efeitos da radiação , Modelos Biológicos , Retina/fisiologia , Retina/efeitos da radiação , Simulação por Computador , Relação Dose-Resposta a Droga , Humanos , Luz , Estimulação Luminosa/métodos , Células Fotorreceptoras/fisiologia , Células Fotorreceptoras/efeitos da radiação , Doses de Radiação
8.
Clin Neuroradiol ; 26(4): 391-403, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26589207

RESUMO

In recent years many papers about diagnostic applications of diffusion tensor imaging (DTI) have been published. This is because DTI allows to evaluate in vivo and in a non-invasive way the process of diffusion of water molecules in biological tissues. However, the simplified description of the diffusion process assumed in DTI does not permit to completely map the complex underlying cellular components and structures, which hinder and restrict the diffusion of water molecules. These limitations can be partially overcome by means of diffusion kurtosis imaging (DKI). The aim of this paper is the description of the theory of DKI, a new topic of growing interest in radiology. DKI is a higher order diffusion model that is a straightforward extension of the DTI model. Here, we analyze the physics underlying this method, we report our MRI acquisition protocol with the preprocessing pipeline used and the DKI parametric maps obtained on a 1.5 T scanner, and we review the most relevant clinical applications of this technique in various neurological diseases.


Assuntos
Encefalopatias/patologia , Encéfalo/patologia , Imagem de Difusão por Ressonância Magnética/métodos , Imagem de Tensor de Difusão/métodos , Interpretação de Imagem Assistida por Computador/métodos , Substância Branca/patologia , Algoritmos , Humanos , Aumento da Imagem/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
10.
Eur J Pharm Biopharm ; 59(1): 139-46, 2005 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-15567311

RESUMO

Ionizing radiation can be used as a drug sterilization technique, provided that the drug itself is not modified and that no toxic products are produced; moreover, if the irradiated product is a drug delivery system, the drug release characteristics must not be significantly altered by radiation. The aim of this work was to study the effects of sterilization by ionizing radiation on hydroxyethylcellulose/trehalose spherical micromatrices, containing the antibiotic vancomycin. Our experimental results showed that gamma-rays did not alter the chromophore groups of vancomycin (UV measurements), and did not modify the kinetic behavior of drug release from microspheres. Moreover, no significant changes in the shape and in the size distribution of microspheres were found after irradiation. The electron spin resonance (ESR) spectroscopy was proven to be a valid identification method of the executed radiation treatment, even after 5 years. The experimental results showed that the therapeutic application of the pharmacological system investigated was not compromised by irradiation, and that ESR spectroscopy can be used to distinguish irradiated from non-irradiated products.


Assuntos
Celulose/análogos & derivados , Celulose/efeitos da radiação , Raios gama , Microesferas , Trealose/efeitos da radiação , Vancomicina/efeitos da radiação , Celulose/química , Trealose/química , Vancomicina/química
11.
Am J Clin Pathol ; 85(3): 305-11, 1986 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-2944374

RESUMO

Hereditary angioedema (HAE) is a disease related to a complement disorder, namely a deficiency of C1 esterase inhibitor. Complement-split products are implicated in the regulation of the immune response, and we have compared some immunologic parameters between HAE and normal individuals. T-lymphocytes with receptors for IgG were increased in HAE, but no difference in T-cell suppressor activity for B-cells was detected. Furthermore, increased IgG receptor expression was not accompanied by any significant changes in the ratios of OKT4- and OKT8-defined antigens. Numbers of peripheral mononuclear cells (MNC) detected by alpha-naphthyl acetate esterase (ANAE) staining positivity were not significantly modified in HAE patients, although there was a trend toward higher absolute numbers of them showing paranuclear localization of ANAE. HAE patients had significantly reduced numbers of Langerhans cells (LC) showing different morphology and localization patterns. These observations are discussed in terms of differential membrane arrangements related to particular stages of cell activation, possibly attributable to continual complement activation resulting from a lack of control by C1 esterase inhibitor.


Assuntos
Angioedema/imunologia , Células de Langerhans/patologia , Receptores de Antígenos de Linfócitos T/análise , Linfócitos T/imunologia , Adulto , Angioedema/genética , Angioedema/patologia , Anticorpos Monoclonais , Contagem de Células , Feminino , Imunofluorescência , Humanos , Contagem de Leucócitos , Masculino , Pessoa de Meia-Idade , Monócitos/patologia , Pele/imunologia , Pele/patologia , Linfócitos T Reguladores/imunologia
12.
J Gerontol A Biol Sci Med Sci ; 54(4): B150-3, 1999 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-10219002

RESUMO

The aim of this study was to examine the complement system and the distribution of some human leukocyte antigen (HLA) class III alleles (C4, BF) in healthy aged people (77 centenarians and 89 elderly subjects). We have also studied the alleles of C3, a complement component genetically unrelated to HLA, the immunochemical levels of C4 and C3 and serum functional hemolytic activity for classical (CH50) and alternative (AP50) complement pathway. The levels of C3 and C4 and the CH50 and AP50 were found to be within the normal range. The frequencies of C3, BF, and C4A alleles were similar in the cohorts that have been studied. For C4B null allele (C4BQ0) a trend toward an increase in the older cohort was observed, although the differences were not significant after statistical correction. Our data suggest that the complement system is well preserved in centenarians and elderly subjects and class III HLA antigens are equally distributed in aged cohorts and in young healthy individuals.


Assuntos
Envelhecimento/genética , Alelos , Ativação do Complemento/genética , Complemento C3/genética , Complemento C4/genética , Fator B do Complemento/genética , Adulto , Idoso , Idoso de 80 Anos ou mais , Envelhecimento/imunologia , Estudos de Coortes , Complemento C3/análise , Complemento C4/análise , Fator B do Complemento/análise , Via Alternativa do Complemento/genética , Via Clássica do Complemento/genética , DNA/genética , Feminino , Deleção de Genes , Antígenos HLA/genética , Hemólise , Humanos , Masculino , Pessoa de Meia-Idade , Polimorfismo Genético
13.
Eur J Pharmacol ; 346(2-3): 283-90, 1998 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-9652371

RESUMO

Here we investigate the effects of tetracycline base and of a semi-synthetic tetracycline derivative, doxycycline, on the induction of inducible nitric oxide synthase and, hence, on the production of nitric oxide (NO) by lipopolysaccharide in J774 macrophage cultured in vitro. The treatment of J774 line with tetracycline base (6.25-250 microM) or doxycycline (5-50 microM) dose-dependently decreased the lipopolysaccharide-stimulated (1 microg/ml) inducible NO synthase activity and, consequently, nitrite formation. For instance, the inhibition was 70% for tetracycline base at 250 microM and 68% for doxycycline at 50 microM. The inhibitory effect of tetracyclines was due neither to a reduction in the viability of the cells, studied as colorimetric 3-[4,5-dimethylthiazol-2yl]-2,5-diphenyltetrazolium bromide (MTT) reduction assay, nor to an indiscriminate inhibition of total protein synthesis, but to a specific decrease in inducible NO synthase protein content in the cells, as attested by the significant reduction of the expression of inducible NO synthase, assayed by sodium-dodecyl sulphate-polyacrylamide gel electrophoresis (SDS-PAGE) and Western blot. However, no effect of tetracyclines on inducible NO synthase mRNA accumulation could be demonstrated in lipopolysaccharide-stimulated macrophage line, suggesting that the inhibitory effect of tetracyclines on NO synthesis involves post-transcriptional events. The reduction in lipopolysaccharide-stimulated nitrite accumulation produced by tetracyclines was significantly less when they were applied 6 h after lipopolysaccharide and absent 12 h after lipopolysaccharide, indicating that tetracyclines modify an early event in inducible NO synthase activation operating after mRNA transcription. The findings presented in this study indicate that the modulation of NO synthesis is another possible pathway by which tetracyclines may function as anti-inflammatory compounds.


Assuntos
Antibacterianos/farmacologia , Endotoxinas/farmacologia , Macrófagos/enzimologia , Óxido Nítrico Sintase/antagonistas & inibidores , Tetraciclina/farmacologia , Animais , Western Blotting , Sobrevivência Celular/efeitos dos fármacos , Doxiciclina/farmacologia , Eletroforese em Gel de Poliacrilamida , Indução Enzimática/efeitos dos fármacos , Escherichia coli , Macrófagos/efeitos dos fármacos , Camundongos , Óxido Nítrico Sintase/biossíntese , Óxido Nítrico Sintase Tipo II , Polissacarídeos/farmacologia , Biossíntese de Proteínas , RNA Mensageiro/biossíntese
14.
Chem Phys Lipids ; 65(1): 85-9, 1993 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-8348678

RESUMO

Broadband ultrasonic absorption spectra are discussed for some aqueous solutions of single-walled phospholipid bilayer vesicles. It is shown that the excess absorption found with all samples can be represented by a sum of a Debye-type relaxation term with discrete relaxation time and a Fixman-Kawasaki term. The former term reflects the kinetics of structural isomerization of the hydrocarbon chains. The values of its relaxation time (0.09-0.56 ns) agree with those for pure n-alkanes of comparable length. The latter terms seems to be due to density fluctuations in the hydrocarbon part of the double layer. Fluctuation correlation lengths between 1 and 30 A result from the analysis of the ultrasonic spectra.


Assuntos
Bicamadas Lipídicas/química , Fosfolipídeos/química , Fenômenos Químicos , Físico-Química , Isomerismo , Modelos Biológicos , Análise Espectral/métodos , Ultrassom
15.
Phys Med Biol ; 46(2): 461-71, 2001 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-11229726

RESUMO

Solid state pellets (1 mm thick) for electron spin resonance (ESR) dosimetry were made using ammonium tartrate as the radiation-sensitive substance. Their behaviour was experimentally investigated as a function of dose with 60Co gamma rays. The calibration function obtained permits measurements of absorbed dose in the 2-50 Gy range, with a combined uncertainty of +/-4%. The lowest detectable dose was about 0.5 Gy. These properties are comparable with or even better than those of ESR dosimeters made from other materials. The time stability of the ESR signal of ammonium tartrate dosimeters at different storage conditions after irradiation was studied. A rather complex behaviour was observed, which suggests that more species of free radicals are produced by radiation and that migration processes may be effective. No dependence of the response on beam quality was found for high-energy photon and electron beams produced by a linear accelerator used in radiotherapy, whereas dose was underestimated with low-energy x-rays.


Assuntos
Espectroscopia de Ressonância de Spin Eletrônica/métodos , Radiometria/métodos , Fenômenos Biofísicos , Biofísica , Elétrons/uso terapêutico , Radicais Livres/efeitos da radiação , Humanos , Microesferas , Tamanho da Partícula , Fótons/uso terapêutico , Radiometria/estatística & dados numéricos , Planejamento da Radioterapia Assistida por Computador , Tartaratos/efeitos da radiação
16.
Phys Med Biol ; 40(2): 211-20, 1995 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-7708849

RESUMO

To ensure the effectiveness of radiation-therapy treatments, both in-phantom and in-patient reliable dose measurements are required. Thermoluminescence dosimeters are used commonly for both applications. Among the various available materials, the relatively new LiF:Mg,Cu,P phosphor is a suitable candidate for quality control of in vivo dosimetry in electron-beam therapy. The response behaviour of LiF:Mg,Cu,P chips to 6-21 MeV electron beams used in radiotherapy was studied. Batch homogeneity, dose linearity, sensitivity change after use, dose and dose-rate response, energy dependence and fading characteristics were investigated. The contribution from each factor to the overall uncertainty in dose measurement was evaluated. The results of this work show that the LiF:Mg,Cu,P chips are comparable to the commonly used LiF:Mg,Ti ones, and support their use for in vivo electron-beam dosimetry to an accuracy within +/- 10%.


Assuntos
Radioterapia de Alta Energia , Dosimetria Termoluminescente , Humanos , Modelos Teóricos , Fatores de Tempo
17.
Health Phys ; 63(3): 356-9, 1992 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-1644574

RESUMO

The population exposure to those living on the island of Pantelleria, Italy, was estimated by measuring the natural gamma background. Gamma spectra of natural rocks and measurements of absorbed dose in air were taken. A correlation was found between the mean gamma exposure rate and the mean values of natural radionuclide concentrations in the investigated rocks.


Assuntos
Radiação de Fundo , Desastres , Monitoramento Ambiental , Raios gama , Fenômenos Geológicos , Geologia , Itália , Ilhas do Mediterrâneo , Monitoramento de Radiação
18.
Ann Ital Med Int ; 9(3): 167-72, 1994.
Artigo em Inglês | MEDLINE | ID: mdl-7946894

RESUMO

The complement system is an important part of non clonal or innate immunity that collaborates with acquired immunity to kill pathogens and to facilitate the clearance of immune complexes. The complement is made up of 20 distinct plasma proteins and 9 different membrane proteins. Three components, factor B, C2 and C4 (with 2 isotypes), are coded by polymorphic HLA-linked genes and are sometimes referred to as class III antigens, inherited as compact units called complotypes. The C4 genes are the most polymorphic, including a common null allele (Q0) at both the C4A and C4B loci. Other polymorphic complement factors (not linked to HLA) are C3 (2 common alleles), C6 and C7 (closely linked, with 3 and 2 alleles, respectively). A certain degree of polymorphism has also been described for complement receptors and membrane control proteins. No differences in functional activity are usually detected among different alleles. Immune-mediated diseases are associated with C4Q0, in particular: systemic lupus erythematosus and discoid-systemic lupus erythematosus, insulin-dependent diabetes mellitus, liver cirrhosis, celiac disease and IgA/IgG4 deficiency. Even if optimal HLA markers do become available, genetic counselling is usually not the ultimate goal for dealing with most of the HLA-associated common diseases, although their study could help to better delineate disease pathogenesis.


Assuntos
Proteínas do Sistema Complemento/genética , Polimorfismo Genético , Hiperplasia Suprarrenal Congênita/genética , Hiperplasia Suprarrenal Congênita/imunologia , Idoso , Idoso de 80 Anos ou mais , Alelos , Criança , Complemento C2/deficiência , Complemento C3/genética , Complemento C4/genética , Diabetes Mellitus Tipo 1/genética , Diabetes Mellitus Tipo 1/imunologia , Feminino , Ligação Genética , Marcadores Genéticos , Humanos , Deficiência de IgA/genética , Deficiência de IgG/genética , Lúpus Eritematoso Sistêmico/genética , Lúpus Eritematoso Sistêmico/imunologia , Complexo Principal de Histocompatibilidade/genética , Complexo Principal de Histocompatibilidade/imunologia , Masculino , Pessoa de Meia-Idade , Receptores de Complemento/genética
19.
Appl Radiat Isot ; 55(2): 259-65, 2001 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-11393768

RESUMO

A high-purity germanium detector has been used to measure the abundance of radium (Ra), thorium (Th) and potassium (K) in building materials used in Sicilian dwellings. The measurements were performed to evaluate which material was suitable for the construction of an enclosure, which would have a low background emission. The materials examined in this work showed concentrations of 226Ra, 232Th and 40K dramatically variable depending on the lithologies, particularly in the case of blocks, sands and aggregates commonly used in building materials in Sicily. The results are discussed and a criterion is indicated to reduce the radiation dose to humans. Since radon inlet is a major health problem, all the radiometric data and the geochemical features have been used to determine the radon exhalation, which arises from the disintegration of 226Ra in soils and walls of houses. From our experimental data it can be seen out that one of the geochemical parameters, Total Alkali (TA), may be an appropriate index to select materials of low radiological risk.


Assuntos
Materiais de Construção/efeitos adversos , Materiais de Construção/análise , Raios gama/efeitos adversos , Monitoramento de Radiação , Radioisótopos/análise , Radônio/análise , Algoritmos , Relação Dose-Resposta à Radiação , Humanos , Modelos Teóricos , Radioisótopos de Potássio/análise , Monitoramento de Radiação/instrumentação , Monitoramento de Radiação/métodos , Sicília , Tório/análise , Difração de Raios X/métodos
20.
Appl Radiat Isot ; 54(4): 701-6, 2001 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-11225708

RESUMO

Air kerma was measured in the "Vulcano Porto" area of the Vulcano Island, belonging to the Aeolian Islands, in the Mediterranean Sea. Measurements were carried out using thermoluminescence dosimeters. The relationship between observed dose values and source lithology has been assessed. Data show a seasonal variation due to weather conditions but also probably related to features of the soils, making the variation more evident.


Assuntos
Ar/análise , Radioisótopos de Potássio/análise , Monitoramento de Radiação/métodos , Tório/análise , Urânio/análise , Geografia , Itália , Ilhas do Mediterrâneo , Estações do Ano , Solo , Saúde da População Urbana , Tempo (Meteorologia)
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA