Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Tipo de documento
País/Região como assunto
Intervalo de ano de publicação
1.
Prague Med Rep ; 116(2): 139-54, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26093668

RESUMO

The Demirjian methods to determine dental age are based on analysis of orthopantograms. The dental age estimation is based on establishing the tooth development stages. The purpose of this study was to assess the accuracy of estimation of dental age by Demirjian in the use of all of his four methods. 505 Czech healthy boys and girls aged 3 to 18 years were examined radiographically at the Department of Stomatology, Second Faculty of Medicine, Charles University in Prague. It was mentioned the factors of underlying diseases influence the accuracy of the dental age estimation. For statistical evaluation, descriptive statistics was used to compare deviations of the mean values of chronological and dental age in each age group. The resulting difference between dental age and chronological age is not significant in both genders only when using both Demirjian 7-teeth methods of 1973 and 1976. Therefore these may be most appropriately used for forensic age estimation. There are shown standard deviation differences in different countries. Demirjian's original 7-teeth method from 1973 and Demirjian's revised 4-teeth method from 1976 appear to be the best methods for calculating the dental age of healthy Czech children of both genders.


Assuntos
Determinação da Idade pelos Dentes/métodos , Radiografia Panorâmica , Adolescente , Criança , Pré-Escolar , República Tcheca , Feminino , Humanos , Masculino
2.
Diagnostics (Basel) ; 13(16)2023 Aug 10.
Artigo em Inglês | MEDLINE | ID: mdl-37627901

RESUMO

Malignant transformation of oral lichen planus (OLP) into oral squamous cell carcinoma is considered as one of the most serious complications of OLP. For the early detection of oral cancer in OLP follow-up, accurate localization of the OLP center is still difficult but often required for confirmatory biopsy with histopathological examination. Optical coherence tomography (OCT) offers the potential for more reliable biopsy sampling in the oral cavity as it is capable of non-invasively imaging the degenerated oral layer structure. In this case-series study with 15 patients, features of clinically classified forms of OLP in OCT cross-sections were registered and correlated with available histologic sections. Besides patients with reticular, atrophic, erosive and plaque-like OLP, two patients with leukoplakia were included for differentiation. The results show that OCT yields information about the epithelial surface, thickness and reflectivity, as well as the identifiability of the basement membrane and the vessel network, which could be used to complement the visual clinical appearance of OLP variants and allow a more accurate localization of the OLP center. This forms the basis for further studies on OCT-assisted non-invasive clinical classification of OLP, with the aim of enabling decision support for biopsy sampling in the future.

3.
Oral Maxillofac Surg ; 2022 Nov 04.
Artigo em Inglês | MEDLINE | ID: mdl-36331629

RESUMO

PURPOSE: Following the introduction of the Regulation (EU) 2017/745 by the European Parliament, any bioactive substance or surgical implant introduced into the human body must be documented. The regulation requires any implant to be traced back to the manufacturer. Lot numbers need to be available for every single medical implant. Also, the manufacturer is required by law to provide implants individually packaged and sterilized. Previously, model tray systems (MOS tray) were used for osteosynthesis in oral and maxillofacial surgery, in which the individual implants could not be registered separately. The new regulation made it impossible to use such processes during surgery anymore and a need for a change in the medical practice surged. We examined a possible solution for the new legislation. The aim of this prospective cohort study is to analyze the MOS tray systems to osteosynthesis materials prepackaged in sets. We record and evaluate parameters such as surgical time and documentation time. We perform a short cost analysis of our clinic. The primary aim is to determine how much time is gained or lost by the mandatory increased patient safety. The secondary aim is to describe change in costs. METHODS: Patients that underwent standard surgical procedures in the clinic of oral and maxillofacial surgery of the faculty hospital Carl Gustav Carus in Dresden were included. We chose open reduction and internal fixation (ORIF) of anterior mandibular corpus fractures as well as mandibular advancement by means of bilateral sagittal split osteotomies (BSSO) as standardized procedures. Both of these procedures require two osteosynthesis plates and at least four screws for each plate. MOS trays were compared to prepackaged sterilized sets. The sets include a drill bit, two plates, and eight 5-mm screws. A total number of 40 patients were examined. We allocated 20 patients to the ORIF group and the other 20 patients to the BSSO group. Each group was evenly subdivided into a MOS tray group and a prepackaged group. Parameters such as the incision-suture time (IST) as well as the documentation time (DT) by the operating room (OR) staff to complete documentation for the implants are the main focus of investigation. RESULTS: For open reduction, the incision-suture time was significantly different in favor of the MOS tray (p < 0.05). There was no difference in the BSSO groups. However, we observed a significantly different (p < 0.01) documentation time advantage for the prepackaged sets in both the ORIF and BSSO groups. On top of that, we find that by using the prepackaged kits, we are able to reduce sterilization costs by €11.53 per size-reduced container. Also, there is also a total cut of costs of €38.90 and €43.70, respectively, per standardized procedure for implant material. CONCLUSIONS: By law, a change in the method of approaching surgery is necessary. For standardized procedures, the right choice of implants can lead to a reduction of documentation time and costs for implant material, sterilization, as well as utilizing less instruments. This in turn leads to lower costs for perioperative processing as well as provision of state-of-the-art implant quality implementing higher patient security.

4.
IEEE Trans Biomed Eng ; 69(7): 2276-2282, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-34995178

RESUMO

This study presents a highly miniaturized, handheld probe developed for rapid assessment of soft tissue using optical coherencetomography (OCT). OCT is a non-invasive optical technology capable of visualizing the sub-surface structural changes that occur in soft tissue disease such as oral lichen planus. However, usage of OCT in the oral cavity has been limited, as the requirements for high-quality optical scanning have often resulted in probes that are heavy, unwieldy and clinically impractical. In this paper, we present a novel probe that combines an all-fiber optical design with a light-weight magnetic scanning mechanism to provide easy access to the oral cavity. The resulting probe is approximately the size of a pen (10 mm × 140 mm) and weighs only 10 grams. To demonstrate the feasibility and high image quality achieved with the probe, imaging was performed on the buccal mucosa and alveolar mucosa during routine clinical assessment of six patients diagnosed with oral lichen planus. Results show the loss of normal tissue structure within the lesion, and contrast this with the clear delineation of tissue layers in adjacent inconspicuous regions. The results also demonstrate the ability of the probe to acquire a three-dimensional data volume by manually sweeping across the surface of the mucosa. The findings of this study show the feasibility of using a small, lightweight probe to identify pathological features in oral soft tissue.


Assuntos
Líquen Plano Bucal , Tomografia de Coerência Óptica , Desenho de Equipamento , Tecnologia de Fibra Óptica , Humanos , Tomografia de Coerência Óptica/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA