Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 34
Filtrar
1.
Sensors (Basel) ; 24(4)2024 Feb 08.
Artigo em Inglês | MEDLINE | ID: mdl-38400258

RESUMO

Various accelerometry protocols have been used to quantify upper extremity (UE) activity, encompassing diverse epoch lengths and thresholding methods. However, there is no consensus on the most effective approach. The aim of this study was to delineate the optimal parameters for analyzing accelerometry data to quantify UE use in individuals with unilateral cerebral palsy (CP). METHODS: A group of adults with CP (n = 15) participated in six activities of daily living, while a group of children with CP (n = 14) underwent the Assisting Hand Assessment. Both groups performed the activities while wearing ActiGraph GT9X-BT devices on each wrist, with concurrent video recording. Use ratio (UR) derived from accelerometry and video analysis and accelerometer data were compared for different epoch lengths (1, 1.5, and 2 s) and activity count (AC) thresholds (between 2 and 150). RESULTS: In adults, results are comparable across epoch lengths, with the best AC thresholds being ≥ 100. In children, results are similar across epoch lengths of 1 and 1.5 (optimal AC threshold = 50), while the optimal threshold is higher with an epoch length of 2 (AC = 75). CONCLUSIONS: The combination of epoch length and AC thresholds should be chosen carefully as both influence the validity of the quantification of UE use.


Assuntos
Paralisia Cerebral , Criança , Adulto , Humanos , Atividades Cotidianas , Extremidade Superior , Acelerometria/métodos , Punho
2.
Sensors (Basel) ; 23(13)2023 Jun 30.
Artigo em Inglês | MEDLINE | ID: mdl-37447906

RESUMO

Assistive robots are tools that people living with upper body disabilities can leverage to autonomously perform Activities of Daily Living (ADL). Unfortunately, conventional control methods still rely on low-dimensional, easy-to-implement interfaces such as joysticks that tend to be unintuitive and cumbersome to use. In contrast, vocal commands may represent a viable and intuitive alternative. This work represents an important step toward providing a viable vocal interface for people living with upper limb disabilities by proposing a novel lightweight vocal command recognition system. The proposed model leverages the MobileNet2 architecture, augmenting it with a novel approach to the self-attention mechanism, achieving a new state-of-the-art performance for Keyword Spotting (KWS) on the Google Speech Commands Dataset (GSCD). Moreover, this work presents a new dataset, referred to as the French Speech Commands Dataset (FSCD), comprising 4963 vocal command utterances. Using the GSCD as the source, we used Transfer Learning (TL) to adapt the model to this cross-language task. TL has been shown to significantly improve the model performance on the FSCD. The viability of the proposed approach is further demonstrated through real-life control of a robotic arm by four healthy participants using both the proposed vocal interface and a joystick.


Assuntos
Robótica , Tecnologia Assistiva , Percepção da Fala , Humanos , Fala , Atividades Cotidianas
3.
Sensors (Basel) ; 23(6)2023 Mar 08.
Artigo em Inglês | MEDLINE | ID: mdl-36991639

RESUMO

Electromyography (EMG) is gaining importance in many research and clinical applications, including muscle fatigue detection, control of robotic mechanisms and prostheses, clinical diagnosis of neuromuscular diseases and quantification of force. However, EMG signals can be contaminated by various types of noise, interference and artifacts, leading to potential data misinterpretation. Even assuming best practices, the acquired signal may still contain contaminants. The aim of this paper is to review methods employed to reduce the contamination of single channel EMG signals. Specifically, we focus on methods which enable a full reconstruction of the EMG signal without loss of information. This includes subtraction methods used in the time domain, denoising methods performed after the signal decomposition and hybrid approaches that combine multiple methods. Finally, this paper provides a discussion on the suitability of the individual methods based on the type of contaminant(s) present in the signal and the specific requirements of the application.


Assuntos
Algoritmos , Artefatos , Eletromiografia/métodos , Processamento de Sinais Assistido por Computador , Fadiga Muscular
4.
Sensors (Basel) ; 22(3)2022 Jan 28.
Artigo em Inglês | MEDLINE | ID: mdl-35161767

RESUMO

Adults living with cerebral palsy (CP) report bimanual and unimanual difficulties that interfere with their participation in activities of daily living (ADL). There is a lack of quantitative methods to assess the impact of these motor dysfunctions on the relative use of each arm. The objective of this study was to evaluate the concurrent and discriminative validity of accelerometry-based metrics when used to assess bimanual and unimanual functions. METHODS: A group of control subjects and hemiplegic adults living with CP performed six ADL tasks, during which they were wearing an Actigraph GT9X on each wrist and being filmed. Four bimanual and unimanual metrics were calculated from both accelerometry-based and video-based data; these metrics were then compared to one other with an intraclass correlation coefficient (ICC). Some of these metrics were previously validated in other clinical population, while others were novel. The discriminative validity was assessed through comparisons between groups and between tasks. RESULTS: The concurrent validity was considered as good to excellent (ICC = 0.61-0.97) depending on the experience of the raters. The tasks made it possible to discriminate between groups. CONCLUSION: The proposed accelerometry-based metrics are a promising tool to evaluate bimanual and unimanual functions in adults living with CP.


Assuntos
Paralisia Cerebral , Acelerometria , Atividades Cotidianas , Adulto , Braço , Benchmarking , Paralisia Cerebral/diagnóstico , Humanos , Extremidade Superior
5.
J Biomech Eng ; 142(7)2020 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-32005995

RESUMO

The International Society of Biomechanics (ISB) has proposed standardized recommendations for recording human joint motion. The Euler angles-the orientation representation currently proposed by the ISB-have two drawbacks, namely, the issue of singularities (gimbal lock) and the difficulty to obtain clinical and interpretable orientation representation for compound movements. The orientation representation of the shoulder joint with the Euler angles is particularly challenging due to its broad range of motion. This paper proposes and evaluates an alternative orientation representation for shoulder movement based on the tilt-and-torsion representation, a method that aims at providing a more clinically interpretable solution for describing joint movements compared to the standard Euler angles. Three studies were performed to compare the different orientation representation methods. The first two studies consist in simulations of arm elevation in different planes. The third study is an experiment using inertial-measurement-units with one test subject performing shoulder elevation movements in different planes. The tilt-and-torsion representation is then compared with different Euler angle conventions. The results show that Euler angles are biased or clinically uninterpretable for compound movements. Conversely, tilt-and-torsion representation does not suffer from these limitations. Although not extensive, the experiments suggest that the tilt-and-torsion representation has the potential to better represent human movements and provide more clinically interpretable results than the Euler angles.


Assuntos
Ombro , Fenômenos Biomecânicos , Movimento , Amplitude de Movimento Articular , Articulação do Ombro
6.
Sensors (Basel) ; 20(23)2020 Nov 26.
Artigo em Inglês | MEDLINE | ID: mdl-33256127

RESUMO

BACKGROUND: A popular outcome in rehabilitation studies is the activity intensity count, which is typically measured from commercially available accelerometers. However, the algorithms are not openly available, which impairs long-term follow-ups and restricts the potential to adapt the algorithms for pathological populations. The objectives of this research are to design and validate open-source algorithms for activity intensity quantification and classification. METHODS: Two versions of a quantification algorithm are proposed (fixed [FB] and modifiable bandwidth [MB]) along with two versions of a classification algorithm (discrete [DM] vs. continuous methods [CM]). The results of these algorithms were compared to those of a commercial activity intensity count solution (ActiLife) with datasets from four activities (n = 24 participants). RESULTS: The FB and MB algorithms gave similar results as ActiLife (r > 0.96). The DM algorithm is similar to a ActiLife (r ≥ 0.99). The CM algorithm differs (r ≥ 0.89) but is more precise. CONCLUSION: The combination of the FB algorithm with the DM results is a solution close to that of ActiLife. However, the MB version remains valid while being more adaptable, and the CM is more precise. This paper proposes an open-source alternative for rehabilitation that is compatible with several wearable devices and not dependent on manufacturer commercial decisions.


Assuntos
Algoritmos , Dispositivos Eletrônicos Vestíveis , Aceleração , Humanos
7.
Sensors (Basel) ; 19(8)2019 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-31010034

RESUMO

Background: Workplace adaptation is the preferred method of intervention to diminish risk factors associated with the development of work-related shoulder disorders. However, the majority of the workplace assessments performed are subjective (e.g., questionnaires). Quantitative assessments are required to support workplace adaptations. The aims of this study are to assess the concurrent validity of inertial measurement units (IMUs; MVN, Xsens) in comparison to a motion capture system (Vicon) during lifting tasks, and establish the discriminative validity of a wireless electromyography (EMG) system for the evaluation of muscle activity. Methods: Sixteen participants performed 12 simple tasks (shoulder flexion, abduction, scaption) and 16 complex lifting tasks (lifting crates of different weights at different heights). A Delsys Trigno EMG system was used to record anterior and middle deltoids' EMG activity, while the Xsens and Vicon simultaneously recorded shoulder kinematics. Results: For IMUs, correlation coefficients were high (simple task: >0.968; complex task: >0.84) and RMSEs were low (simple task: <6.72°; complex task: <11.5°). For EMG, a significant effect of weight, height and a weight x height interaction (anterior: p < 0.001; middle: p < 0.03) were observed for RMS EMG activity. Conclusions: These results suggest that wireless EMG and IMUs are valid units that can be used to measure physical demand in workplace assessments.


Assuntos
Técnicas Biossensoriais , Amplitude de Movimento Articular/fisiologia , Articulação do Ombro/fisiologia , Dispositivos Eletrônicos Vestíveis , Adulto , Fenômenos Biomecânicos , Eletromiografia , Feminino , Humanos , Masculino , Músculo Esquelético/fisiologia , Tecnologia sem Fio/tendências , Local de Trabalho
8.
Sensors (Basel) ; 20(1)2019 Dec 31.
Artigo em Inglês | MEDLINE | ID: mdl-31906122

RESUMO

Inertial measurement units have recently shown great potential for the accurate measurement of joint angle movements in replacement of motion capture systems. In the race towards long duration tracking, inertial measurement units increasingly aim to ensure portability and long battery life, allowing improved ecological studies. Their main advantage over laboratory grade equipment is their usability in a wider range of environment for greater ecological value. For accurate and useful measurements, these types of sensors require a robust orientation estimation that remains accurate over long periods of time. To this end, we developed the Allumo software for the preprocessing and calibration of the orientation estimate of triaxial accelerometers. This software has an automatic orientation calibration procedure, an automatic erroneous orientation-estimate detection and useful visualization to help process long and short measurement periods. These automatic procedures are detailed in this paper, and two case studies are presented to showcase the usefulness of the software. The Allumo software is open-source and available online.


Assuntos
Acelerometria/instrumentação , Postura/fisiologia , Software , Dispositivos Eletrônicos Vestíveis , Algoritmos , Calibragem , Atividades Humanas , Humanos , Interface Usuário-Computador
9.
Sensors (Basel) ; 19(7)2019 Mar 31.
Artigo em Inglês | MEDLINE | ID: mdl-30935116

RESUMO

Motion capture systems are recognized as the gold standard for joint angle calculation. However, studies using these systems are restricted to laboratory settings for technical reasons, which may lead to findings that are not representative of real-life context. Recently developed commercial and home-made inertial measurement sensors (M/IMU) are potentially good alternatives to the laboratory-based systems, and recent technology improvements required a synthesis of the current evidence. The aim of this systematic review was to determine the criterion validity and reliability of M/IMU for each body joint and for tasks of different levels of complexity. Five different databases were screened (Pubmed, Cinhal, Embase, Ergonomic abstract, and Compendex). Two evaluators performed independent selection, quality assessment (consensus-based standards for the selection of health measurement instruments [COSMIN] and quality appraisal tools), and data extraction. Forty-two studies were included. Reported validity varied according to task complexity (higher validity for simple tasks) and the joint evaluated (better validity for lower limb joints). More studies on reliability are needed to make stronger conclusions, as the number of studies addressing this psychometric property was limited. M/IMU should be considered as a valid tool to assess whole body range of motion, but further studies are needed to standardize technical procedures to obtain more accurate data.


Assuntos
Articulações/fisiologia , Dispositivos Eletrônicos Vestíveis , Acelerometria , Bases de Dados Factuais , Humanos , Movimento , Amplitude de Movimento Articular , Reprodutibilidade dos Testes
10.
J Rehabil Assist Technol Eng ; 11: 20556683241288226, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39372217

RESUMO

The inability to use one's hands or arms greatly restricts the ability to perform daily activities. After a developmental or acquired injury, the intensity and frequency of rehabilitation exercises are essential. To alleviate the burden on the healthcare system, robotic systems have been developed to support clinicians' interventions. However, these systems are often bulky and expensive, limiting their use to specific clinical settings and making them impractical for home use. This paper presents the development of an affordable and easy to install 2-DOF five-bar linkage robot designed to be used at home. This work aims to reduce the cost of the robot through actuation optimization, mechanical optimization and 3D printing. The architecture and links length are chosen to optimize the robot's performance in the required workspace. Using sensor feedback, impedance control algorithms and multiple types of exercise such as virtual walls guidance are implemented. Finally, a user interface was programmed to facilitate the robot's use.

11.
Front Neurol ; 15: 1425124, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39087017

RESUMO

Introduction: Children with cerebral palsy (CP) exhibit a variety of sensory impairments that can interfere with motor performance, but how these impairments persist into adulthood needs further investigation. The objective of this study was to describe the sensory impairments in adults having CP and how they relate to motor impairments. Methods: Nineteen adults having CP performed a set of robotic and clinical assessments. These assessments were targeting different sensory functions and motor functions (bilateral and unilateral tasks). Frequency of each type of impairments was determined by comparing individual results to normative data. Association between the sensory and motor impairments was assessed with Spearman correlation coefficient. Results: Impairment in stereognosis was the most frequent, affecting 57.9% of participants. Although less frequently impaired (26.3%), tactile discrimination was associated with all the motor tasks (unilateral and bilateral, either robotic or clinical). Performance in robotic motor assessments was more frequently associated with sensory impairments than with clinical assessments. Finally, sensory impairments were not more closely associated with bilateral tasks than with unilateral tasks. Discussion: Somatosensory and visuo-perceptual impairments are frequent among adults with CP, with 84.2% showing impairments in at least one sensory function. These sensory impairments show a moderate association with motor impairments.

12.
PLoS One ; 19(1): e0297283, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38252643

RESUMO

BACKGROUND: Fatigue impacts motor performance and upper limb kinematics. It is of interest to study whether it is possible to minimize the potentially detrimental effects of fatigue with prevention programs. OBJECTIVE: To determine the effect of task-specific training on upper limb kinematics and motor performance when reaching in a fatigued state. METHODS: Thirty healthy participants were recruited (Training group n = 15; Control group n = 15). Both groups took part in two evaluation sessions (Day 1 and Day 5) during which they performed a reaching task (as quickly and accurately as possible) in two conditions (rested and fatigued). During the reaching task, joint kinematics and motor performance (accuracy and speed) were evaluated. The Training group participated in three task-specific training sessions between Day 1 and Day 5; they trained once a day, for three days. The Control group did not perform any training. A three-way non-parametric ANOVA for repeated measures (Nonparametric Analysis of Longitudinal Data; NparLD) was used to assess the impact of the training (Condition [within subject]: rested, fatigued; Day [within subject]: Day 1 vs. Day 5 and Group [between subjects]: Training vs. Control). RESULTS: After the training period, the Training group significantly improved their reaching speed compared to the Control group (Day x Group p < .01; Time effect: Training group = p < .01, Control group p = .20). No between-group difference was observed with respect to accuracy. The Training group showed a reduction in contralateral trunk rotation and lateral trunk flexion in Day 2 under the fatigue condition (Group x Day p < .04; Time effect: Training group = p < .01, Control group = p < .59). CONCLUSION: After the 3-day training, participants demonstrated improved speed and reduced reliance on trunk compensations to complete the task under fatigue conditions. Task-specific training could help minimizing some effects of fatigue.


Assuntos
Mecanismos de Defesa , Fadiga , Humanos , Fenômenos Biomecânicos , Grupos Controle , Extremidade Superior
13.
Assist Technol ; 36(2): 154-163, 2024 Mar 03.
Artigo em Inglês | MEDLINE | ID: mdl-37463509

RESUMO

Assistive devices are designed to enhance individuals with disabilities' functional abilities. The rise of 3D printing technology enabled the production of individualized assistive devices (IADs). A REHAB-LAB is intended for IAD provision involving technical referents and occupational therapists. This study aimed to develop the REHAB-LAB logic model; to explore its fidelity and desirability; and to explore the characteristics of arising initiatives of IAD production. The REHAB-LAB logic model development involved stakeholders throughout the research process. A pragmatic multimethod approach followed two phases 1) logic model development and 2) exploration of its fidelity and desirability. The REHAB-LAB logic model presented the resources (equipment, space, human) required to implement IAD provision in a rehabilitation center, and the expected deliverables (activities and outputs). The REHAB-LAB logic model highlights the interdisciplinarity of IAD provision including occupational therapists, doctors, engineers, managers, and technical referents and places the users at the center of the IAD production. Results confirmed the fidelity and desirability of the REHAB-LAB logic model. The REHAB-LAB logic model can be used as a reference for future healthcare organizations wishing to implement an IAD provision. This research highlighted the interest of IAD provision based on the REHAB-LAB model involving users and transdisciplinary practices.


Assuntos
Pessoas com Deficiência , Tecnologia Assistiva , Humanos , Pessoas com Deficiência/reabilitação , Atividades Cotidianas
14.
Disabil Rehabil Assist Technol ; : 1-20, 2024 Jun 12.
Artigo em Inglês | MEDLINE | ID: mdl-38864384

RESUMO

PURPOSE: To conduct a systematic review on the impacts of using mechanical assistive devices on function, performance in activities and participation of persons with upper extremity impairments, and to synthesize the strengths and limitations of these devices. METHOD: Three independent reviewers conducted systematic searches of articles published between 2003 and 2023 in Compendex, Inspec, Embase, PubMed/Medline, IEEE Xplore, and Web of Science, as well as manual searches on the RESNA website for conference papers over the same period. The methodological quality of articles was appraised using the QualSyst tool. RESULTS: From the 34 retained studies, 28 mechanical devices were identified and classified into two categories: (1) mobile arm supports (MASs) designed to perform multiple activities, and (2) devices used to assist with a specific activity of daily living (ADL). Overall, MASs helped users to perform manual activities in elevation and/or against gravity. Specific ADL devices allowed users to perform unique activities requiring fine motor skills such as opening a medicine container. Some of these devices have advantages like portability, adaptability, low cost, and ease of use. Limitations most often reported included interference or mobility restraints. CONCLUSION: This review synthesizes the impacts of mechanical devices on the three domains of the International Classification of Functioning, Disability and Health (ICF) for individuals with upper extremity impairments. Impacts regarding function and performance in activities were more often measured than participation. Future studies should include outcomes related to participation, as taking this aspect into account might favor successful continued use of assistive devices.


Mechanical mobile arm supports can compensate for upper extremity muscle weakness and help users to perform diverse activities against gravity, including self-care, productivity and leisure activities.Mechanical assistive devices designed for specific activities of daily living (ADLs) can increase users' ability to perform activities requiring manual dexterity and fine motor skills, such as eating, handwriting, performing personal care or playing a musical instrument.Portability, adaptability, low cost, and ease of use are most often reported as strengths of specific ADL devices, while interference and mobility restrictions are aspects that still need to be reduced with respect to mechanical mobile arm supports.

15.
Artigo em Inglês | MEDLINE | ID: mdl-38083603

RESUMO

This work presents EMaGer, a new 360° 64-channel high-density electromyography (HD-EMG) bracelet combined with an original data augmentation method for improved robustness in gesture recognition. By leveraging homogeneous electrode density and powerful deep learning techniques, the sensor is capable of rotation invariance around the arm axis, thus increasing gesture recognition robustness to electrode movement and inter-session evaluation. The system is made of a 4x16 electrode array covering the full circumference of the limb, and uses a sampling frequency of 1 kHz and a 16-bit resolution. The sensor's uniform and adjustable geometry paired with an array barrel shifting data augmentation (ABSDA) technique allows a convolutional neural network to maintain a 76.98% inter-session classification accuracy for a 6 gestures dataset, from a baseline intra-session accuracy of 93.75%. High inter-session classification accuracy decreases the training burden for users of EMG control systems such as myoelectric prostheses by minimizing calibration requirements. The same methods applied with different state-of-the-art sensors are demonstrated to be less effective. Thus, this work evidences the importance of co-designing the EMG sensor system with the gesture inference algorithms to leverage synergistic properties and solve state-of-the-art challenges.Clinical relevance- This paper establishes a method that alleviates clinical manipulations in setting up and calibrating myoelectric prosthetic devices.


Assuntos
Membros Artificiais , Dispositivos Eletrônicos Vestíveis , Eletromiografia/métodos , Gestos , Extremidade Superior
16.
IEEE Trans Biomed Circuits Syst ; 17(5): 968-984, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37695958

RESUMO

In this work, we present a hardware-software solution to improve the robustness of hand gesture recognition to confounding factors in myoelectric control. The solution includes a novel, full-circumference, flexible, 64-channel high-density electromyography (HD-EMG) sensor called EMaGer. The stretchable, wearable sensor adapts to different forearm sizes while maintaining uniform electrode density around the limb. Leveraging this uniformity, we propose novel array barrel-shifting data augmentation (ABSDA) approach used with a convolutional neural network (CNN), and an anti-aliased CNN (AA-CNN), that provides shift invariance around the limb for improved classification robustness to electrode movement, forearm orientation, and inter-session variability. Signals are sampled from a 4×16 HD-EMG array of electrodes at a frequency of 1 kHz and 16-bit resolution. Using data from 12 non-amputated participants, the approach is tested in response to sensor rotation, forearm rotation, and inter-session scenarios. The proposed ABSDA-CNN method improves inter-session accuracy by 25.67% on average across users for 6 gesture classes compared to conventional CNN classification. A comparison with other devices shows that this benefit is enabled by the unique design of the EMaGer array. The AA-CNN yields improvements of up to 63.05% accuracy over non-augmented methods when tested with electrode displacements ranging from -45 ° to +45 ° around the limb. Overall, this article demonstrates the benefits of co-designing sensor systems, processing methods, and inference algorithms to leverage synergistic and interdependent properties to solve state-of-the-art problems.


Assuntos
Aprendizado Profundo , Dispositivos Eletrônicos Vestíveis , Humanos , Eletromiografia , Gestos , Algoritmos , Antebraço/fisiologia
17.
BMJ Open ; 13(3): e064054, 2023 03 15.
Artigo em Inglês | MEDLINE | ID: mdl-36921943

RESUMO

INTRODUCTION: Approximately 33% of people who contracted COVID-19 still experience symptoms 12 weeks after infection onset. This persistence of symptoms is now considered a syndrome itself called 'long COVID'. Evidence regarding long COVID and its cognitive and physical impacts is growing, but the literature is currently lacking objectively measured data to guide towards adapted healthcare trajectories. The objectives are to describe the physical and cognitive impairments experienced by individuals living with long COVID using self-reported and clinical objective measures, and to compare the evolution over time of the physical and cognitive state between adults living with long COVID (at least one physical or cognitive COVID-19 symptom for more than 12 weeks following infection; long COVID group), people who developed COVID-19 but did not experience persistent symptoms (short COVID group) and people who did not develop COVID-19 (control group). METHODS AND ANALYSIS: In this longitudinal cohort study, 120 participants will be recruited in each group. Variables will be collected through three evaluation sessions over 6 months (baseline, 3 months, 6 months). Variables include self-administered questionnaires on health-related quality of life, comorbidity, sleep, pain, anxiety, depressive symptoms, fatigue and cognitive function, as well as objective measures of cognitive (attention, memory, executive functioning) and physical (grip strength, balance, gait speed, gait endurance, VO2, frailty) functions. Activity, heart rate and sleep will be monitored with a fitness tracker watch for 7 days following evaluation sessions. Maximum-likelihood analyses of variance (ANOVAs) will be used to compare data at baseline between groups. Repeated measures ANOVAs will be used to compare the longitudinal performance variations across groups of the self-reported and clinical variables. ETHICS AND DISSEMINATION: Ethics committees of the CIUSSS de la Capitale-Nationale and CIUSSS de l'Est-de-l'Île-de-Montréal approved the project. Results will be disseminated through clinical and community platforms as well as through peer-reviewed manuscripts and international conferences. TRIAL REGISTRATION NUMBER: NCT05216536.


Assuntos
COVID-19 , Disfunção Cognitiva , Adulto , Humanos , Disfunção Cognitiva/epidemiologia , Estudos de Coortes , COVID-19/epidemiologia , Marcha , Estudos Longitudinais , Síndrome de COVID-19 Pós-Aguda , Qualidade de Vida
18.
Disabil Rehabil Assist Technol ; : 1-10, 2022 Jul 22.
Artigo em Inglês | MEDLINE | ID: mdl-35867651

RESUMO

PURPOSE: Dynamic arm supports (DAS) can assist individuals with severe upper limb disabilities who use a wheelchair to accomplish their daily activities. The objective of this case series was to assess the potential of a DAS to improve power wheelchair (PWC) control in real-life contexts and to describe the integration process. A secondary objective was to explore factors that may influence the DAS integration process. METHODS: This case series includes four participants fitted with the Kinova DAS O110. A one-year follow-up was planned for each participant with qualitative and quantitative data collection to assess DAS outcomes. Assessment methods were selected to cover the three vantages of assistive technology outcomes assessment: effectiveness, subjective well-being, and social significance. RESULTS: Among the four participants, one used the DAS to help with his wheelchair control for at least 12 months (successful integration). For him, the DAS led to significantly improved wheelchair skills and an important positive psychosocial impact. He was, however, only able to use the DAS for PWC control (no effects on other daily activities), and could not use it in some contexts because the device increased his PWC width. As for the other participants, they stopped using the DAS for different reasons, including a DAS-related adverse event. CONCLUSION: This study demonstrated that a wheelchair-bound DAS has the potential to improve PWC use, but successful integration requires specific factors. The service delivery process and the environmental accessibility are crucial for the successful integration of such a device and to avoid safety issues.IMPLICATIONS FOR REHABILITATIONNo study deeply assessed the impacts of dynamic arm support on power wheelchair control, and the associated facilitators and obstacles.A wheelchair-bound dynamic arm support has the potential to improve power wheelchair control for individuals with upper limb disabilities and to lead to positive psychosocial impacts if some conditions conductive to successful integration are met.The service delivery process and the environmental accessibility appear as crucial aspects for the successful integration of a new device, such as dynamic arm support and avoiding safety issues.

19.
Assist Technol ; 34(2): 170-177, 2022 03 04.
Artigo em Inglês | MEDLINE | ID: mdl-32105199

RESUMO

Many people living with neurological disorders, such as cerebral palsy, stroke, muscular dystrophy or dystonia, experience upper limb impairments (muscle spasticity, loss of selective motor control, muscle weakness or tremors) and are unable to eat independently. This article presents the development of a new device to assist with eating, aimed at stabilizing the movement of people who have movement disorders. The design was guided by insights gathered through focus groups, with occupational therapists and engineers, about the challenges faced by individuals who have movement disorders and difficulty in eating autonomously. The proposed assistive device prototype is designed to be fixed on a table and to support a spoon. The mechanism is designed so that the spoon maintains a position parallel to the ground for the user. Dampers and inertia allow stabilizing the user's motion. A preliminary trial with five individuals living with cerebral palsy is presented to assess the prototype's performance and to guide future iterations of the prototype. Task completion time generally decreased and movement fluidity generally improved when using the assistive device prototype. The prototype showed good potential in stabilizing the spoon for the user and improving movement fluidity.


Assuntos
Paralisia Cerebral , Transtornos dos Movimentos , Tecnologia Assistiva , Humanos , Movimento , Extremidade Superior
20.
PLoS One ; 17(4): e0266390, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35363820

RESUMO

Work-related upper extremity disorders are costly to society due to resulting medical costs, presenteeism and absenteeism. Although their aetiology is likely multifactorial, physical workplace factors are known to play an important role in their development. Promising options for preventing work-related upper extremity disorders include assistive technologies such as dynamic arm supports designed to follow the movement of the arm while compensating for its weight. The objective of this study was to assess the effects of a dynamic arm support on perceived exertion, muscle activity and movement patterns of the upper limb during repetitive manual tasks in healthy individuals. Thirty healthy right-handed individuals were allocated either a static or a dynamic task to perform with and without a dynamic arm support. During the task, surface electromyographic activity (anterior and middle deltoid, upper trapezius) and upper limb kinematics (elbow, shoulder, sternoclavicular) were measured using surface EMG and inertial sensors. Results showed that the dynamic arm support significantly reduced perceived exertion during the tasks and limited the development of muscular fatigue of the anterior and middle deltoid as demonstrated by EMG signal mean epoch amplitudes and median frequency of the EMG power spectrum. The dynamic arm support also prevented a decrease in shoulder elevation and an increase in total shoulder joint excursion during static and dynamic task, respectively. These results denote the potential benefits of dynamic arm supports in work environments. Further studies should focus on their efficacy, acceptability and implementability in work settings.


Assuntos
Braço , Fadiga Muscular , Braço/fisiologia , Fenômenos Biomecânicos , Eletromiografia/métodos , Humanos , Fadiga Muscular/fisiologia , Músculo Esquelético/fisiologia , Ombro/fisiologia , Extremidade Superior/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA