Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 136
Filtrar
1.
Entropy (Basel) ; 26(2)2024 Feb 08.
Artigo em Inglês | MEDLINE | ID: mdl-38392403

RESUMO

Continuous adaptations of the movement system to changing environments or task demands rely on superposed fractal processes exhibiting power laws, that is, multifractality. The estimators of the multifractal spectrum potentially reflect the adaptive use of perception, cognition, and action. To observe time-specific behavior in multifractal dynamics, a multiscale multifractal analysis based on DFA (MFMS-DFA) has been recently proposed and applied to cardiovascular dynamics. Here we aimed at evaluating whether MFMS-DFA allows identifying multiscale structures in the dynamics of human movements. Thirty-six (12 females) participants pedaled freely, after a metronomic initiation of the cadence at 60 rpm, against a light workload for 10 min: in reference to cycling (C), cycling while playing "Tetris" on a computer, alone (CT) or collaboratively (CTC) with another pedaling participant. Pedal revolution periods (PRP) series were examined with MFMS-DFA and compared to linearized surrogates, which attested to a presence of multifractality at almost all scales. A marked alteration in multifractality when playing Tetris was evidenced at two scales, τ ≈ 16 and τ ≈ 64 s, yet less marked at τ ≈ 16 s when playing collaboratively. Playing Tetris in collaboration attenuated these alterations, especially in the best Tetris players. This observation suggests the high sensitivity to cognitive demand of MFMS-DFA estimators, extending to the assessment of skill/demand interplay from individual behavior. So, by identifying scale-dependent multifractal structures in movement dynamics, MFMS-DFA has obvious potential for examining brain-movement coordinative structures, likely with sufficient sensitivity to find echo in diagnosing disorders and monitoring the progress of diseases that affect cognition and movement control.

2.
Entropy (Basel) ; 26(7)2024 Jul 07.
Artigo em Inglês | MEDLINE | ID: mdl-39056940

RESUMO

A stroke represents a significant medical condition characterized by the sudden interruption of blood flow to the brain, leading to cellular damage or death. The impact of stroke on individuals can vary from mild impairments to severe disability. Treatment for stroke often focuses on gait rehabilitation. Notably, assessing muscle activation and kinematics patterns using electromyography (EMG) and stereophotogrammetry, respectively, during walking can provide information regarding pathological gait conditions. The concurrent measurement of EMG and kinematics can help in understanding disfunction in the contribution of specific muscles to different phases of gait. To this aim, complexity metrics (e.g., sample entropy; approximate entropy; spectral entropy) applied to EMG and kinematics have been demonstrated to be effective in identifying abnormal conditions. Moreover, the conditional entropy between EMG and kinematics can identify the relationship between gait data and muscle activation patterns. This study aims to utilize several machine learning classifiers to distinguish individuals with stroke from healthy controls based on kinematics and EMG complexity measures. The cubic support vector machine applied to EMG metrics delivered the best classification results reaching 99.85% of accuracy. This method could assist clinicians in monitoring the recovery of motor impairments for stroke patients.

3.
Entropy (Basel) ; 25(2)2023 Feb 02.
Artigo em Inglês | MEDLINE | ID: mdl-36832650

RESUMO

Distribution Entropy (DistEn) has been introduced as an alternative to Sample Entropy (SampEn) to assess the heart rate variability (HRV) on much shorter series without the arbitrary definition of distance thresholds. However, DistEn, considered a measure of cardiovascular complexity, differs substantially from SampEn or Fuzzy Entropy (FuzzyEn), both measures of HRV randomness. This work aims to compare DistEn, SampEn, and FuzzyEn analyzing postural changes (expected to modify the HRV randomness through a sympatho/vagal shift without affecting the cardiovascular complexity) and low-level spinal cord injuries (SCI, whose impaired integrative regulation may alter the system complexity without affecting the HRV spectrum). We recorded RR intervals in able-bodied (AB) and SCI participants in supine and sitting postures, evaluating DistEn, SampEn, and FuzzyEn over 512 beats. The significance of "case" (AB vs. SCI) and "posture" (supine vs. sitting) was assessed by longitudinal analysis. Multiscale DistEn (mDE), SampEn (mSE), and FuzzyEn (mFE) compared postures and cases at each scale between 2 and 20 beats. Unlike SampEn and FuzzyEn, DistEn is affected by the spinal lesion but not by the postural sympatho/vagal shift. The multiscale approach shows differences between AB and SCI sitting participants at the largest mFE scales and between postures in AB participants at the shortest mSE scales. Thus, our results support the hypothesis that DistEn measures cardiovascular complexity while SampEn/FuzzyEn measure HRV randomness, highlighting that together these methods integrate the information each of them provides.

4.
Sensors (Basel) ; 22(8)2022 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-35458875

RESUMO

The interest in photoplethysmography (PPG) for sleep monitoring is increasing because PPG may allow assessing heart rate variability (HRV), which is particularly important in breathing disorders. Thus, we aimed to evaluate how PPG wearable systems measure HRV during sleep at high altitudes, where hypobaric hypoxia induces respiratory disturbances. We considered PPG and electrocardiographic recordings in 21 volunteers sleeping at 4554 m a.s.l. (as a model of sleep breathing disorder), and five alpine guides sleeping at sea level, 6000 m and 6800 m a.s.l. Power spectra, multiscale entropy, and self-similarity were calculated for PPG tachograms and electrocardiography R-R intervals (RRI). Results demonstrated that wearable PPG devices provide HRV measures even at extremely high altitudes. However, the comparison between PPG tachograms and RRI showed discrepancies in the faster spectral components and at the shorter scales of self-similarity and entropy. Furthermore, the changes in sleep HRV from sea level to extremely high altitudes quantified by RRI and PPG tachograms in the five alpine guides tended to be different at the faster frequencies and shorter scales. Discrepancies may be explained by modulations of pulse wave velocity and should be considered to interpret correctly autonomic alterations during sleep from HRV analysis.


Assuntos
Fotopletismografia , Dispositivos Eletrônicos Vestíveis , Altitude , Eletrocardiografia/métodos , Frequência Cardíaca/fisiologia , Humanos , Fotopletismografia/métodos , Polissonografia , Análise de Onda de Pulso , Sono
5.
Philos Trans A Math Phys Eng Sci ; 379(2212): 20200254, 2021 Dec 13.
Artigo em Inglês | MEDLINE | ID: mdl-34689623

RESUMO

Recent advancements in detrended fluctuation analysis (DFA) allow evaluating multifractal coefficients scale-by-scale, a promising approach for assessing the complexity of biomedical signals. The multifractality degree is typically quantified by the singularity spectrum width (WSS), a method that is critically unstable in multiscale applications. Thus, we aim to propose a robust multiscale index of multifractality, compare it with WSS and illustrate its performance on real biosignals. The proposed index is the cumulative function of squared increments between consecutive DFA coefficients at each scale n: αCF(n). We compared it with WSS calculated scale-by-scale considering monofractal/monoscale, monofractal/multiscale, multifractal/monoscale and multifractal/multiscale random processes. The two indices provided qualitatively similar descriptions of multifractality, but αCF(n) differentiated better the multifractal components from artefacts due to crossovers or detrending overfitting. Applied on 24 h heart rate recordings of 14 participants, the singularity spectrum failed to always satisfy the concavity requirement for providing meaningful WSS, while αCF(n) demonstrated a statistically significant heart rate multifractality at night in the scale ranges 16-100 and 256-680 s. Furthermore, αCF(n) did not reject the hypothesis of monofractality at daytime, coherently with previous reports of lower nonlinearity and monoscale multifractality during the day. Thus, αCF(n) appears a robust index of multiscale multifractality that is useful for quantifying complexity alterations of physiological series. This article is part of the theme issue 'Advanced computation in cardiovascular physiology: new challenges and opportunities'.


Assuntos
Fractais , Frequência Cardíaca , Humanos
6.
Entropy (Basel) ; 22(9)2020 Sep 09.
Artigo em Inglês | MEDLINE | ID: mdl-33286774

RESUMO

The idea that most physiological systems are complex has become increasingly popular in recent decades [...].

7.
Entropy (Basel) ; 22(4)2020 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-33286236

RESUMO

Recently, a multifractal-multiscale approach to detrended fluctuation analysis (DFA) was proposed to evaluate the cardiovascular fractal dynamics providing a surface of self-similarity coefficients α(q,τ), function of the scale τ, and moment order q. We hypothesize that this versatile DFA approach may reflect the cardiocirculatory adaptations in complexity and nonlinearity occurring during the day/night cycle. Our aim is, therefore, to quantify how α(q, τ) surfaces of cardiovascular series differ between daytime and night-time. We estimated α(q,τ) with -5 ≤ q ≤ 5 and 8 ≤ τ ≤ 2048 s for heart rate and blood pressure beat-to-beat series over periods of few hours during daytime wake and night-time sleep in 14 healthy participants. From the α(q,τ) surfaces, we estimated short-term (<16 s) and long-term (from 16 to 512 s) multifractal coefficients. Generating phase-shuffled surrogate series, we evaluated short-term and long-term indices of nonlinearity for each q. We found a long-term night/day modulation of α(q,τ) between 128 and 256 s affecting heart rate and blood pressure similarly, and multifractal short-term modulations at q < 0 for the heart rate and at q > 0 for the blood pressure. Consistent nonlinearity appeared at the shorter scales at night excluding q = 2. Long-term circadian modulations of the heart rate DFA were previously associated with the cardiac vulnerability period and our results may improve the risk stratification indicating the more relevant α(q,τ) area reflecting this rhythm. Furthermore, nonlinear components in the nocturnal α(q,τ) at q ≠ 2 suggest that DFA may effectively integrate the linear spectral information with complexity-domain information, possibly improving the monitoring of cardiac interventions and protocols of rehabilitation medicine.

8.
Entropy (Basel) ; 22(5)2020 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-33286301

RESUMO

The surface electromyography (sEMG) records the electrical activity of muscle fibers during contraction: one of its uses is to assess changes taking place within muscles in the course of a fatiguing contraction to provide insights into our understanding of muscle fatigue in training protocols and rehabilitation medicine. Until recently, these myoelectric manifestations of muscle fatigue (MMF) have been assessed essentially by linear sEMG analyses. However, sEMG shows a complex behavior, due to many concurrent factors. Therefore, in the last years, complexity-based methods have been tentatively applied to the sEMG signal to better individuate the MMF onset during sustained contractions. In this review, after describing concisely the traditional linear methods employed to assess MMF we present the complexity methods used for sEMG analysis based on an extensive literature search. We show that some of these indices, like those derived from recurrence plots, from entropy or fractal analysis, can detect MMF efficiently. However, we also show that more work remains to be done to compare the complexity indices in terms of reliability and sensibility; to optimize the choice of embedding dimension, time delay and threshold distance in reconstructing the phase space; and to elucidate the relationship between complexity estimators and the physiologic phenomena underlying the onset of MMF in exercising muscles.

9.
Entropy (Basel) ; 21(6)2019 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-33267264

RESUMO

Multiscale entropy (MSE) provides information-domain measures of the systems' complexity. The increasing interest in MSE of the cardiovascular system lies in the possibility of detecting interactions with other regulatory systems, as higher neural networks. However, most of the MSE studies considered the heart-rate (HR) series only and a limited number of scales: actually, an integrated approach investigating HR and blood-pressure (BP) entropies and cross-entropy over the range of scales of traditional spectral analyses is missing. Therefore, we aim to highlight influences of higher brain centers and of the autonomic control on multiscale entropy and cross-entropy of HR and BP over a broad range of scales, by comparing different behavioral states over 24 h and by evaluating the influence of hypertension, which reduces the autonomic control of BP. From 24-h BP recordings in eight normotensive and eight hypertensive participants, we selected subperiods during daytime activities and nighttime sleep. In each subperiod, we derived a series of 16,384 consecutive beats for systolic BP (SBP), diastolic BP (DBP), and pulse interval (PI). We applied a modified MSE method to obtain robust estimates up to time scales of 334 s, covering the traditional frequency bands of spectral analysis, for three embedding dimensions and compared groups (rank-sum test) and conditions (signed-rank test) at each scale. Results demonstrated night-and-day differences at scales associable with modulations in vagal activity, in respiratory mechanics, and in local vascular regulation, and reduced SBP-PI cross-entropy in hypertension, possibly representing a loss of complexity due to an impaired baroreflex sensitivity.

10.
J Electrocardiol ; 51(6): 967-972, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30497757

RESUMO

BACKGROUND: An abnormal frontal QRS-T angle (fQRSTa) is associated with increased risk of death in primary and secondary cardiovascular prevention. The aim of this study was to evaluate the fQRSTa prognostic role in patients undergoing myocardial revascularization and/or cardiac valve surgery. METHODS: We enrolled and prospectively followed for 48 ±â€¯26 months 939 subjects with available QRS and T axis data; mean age was 68 ±â€¯12 years, 449 patients (48%) underwent myocardial revascularization, 333 (35%) cardiac valve surgery, 94 (10%) valve plus bypass graft surgery and 63 (7%) cardiac surgery for other cardiovascular (CV) diseases. The ECG variables were collected at the end of the cardiac rehabilitation program and fQRSTa was considered normal if <60°, abnormal if >120°, borderline otherwise. Endpoints were overall and CV mortality. RESULTS: The fQRSTa was normal in 333 patients (36%), borderline in 285 (30%) and abnormal in 321 (34%). Overall (p = 0.012) and cardiovascular (p = 0.007) mortality were significantly higher in patients with abnormal fQRSTa even after adjusting separately for gender, PR-, QTc- intervals, presence of right or left bundle branch block and left atrial volume index. The predictive value was confirmed in patients with stable coronary artery disease (SCAD), not in patients with acute coronary syndrome or valve disease. SCAD patients with abnormal both fQRSTa and QRS axis had higher risk of overall (hazard ratio = 2.9, p < 0.0001) and CV (hazard ratio = 4.4, p < 0.0001) mortality compared with SCAD patients with normal fQRSTa, even after multivariate adjustment for age, gender, ECG intervals, left-ventricle ejection fraction and mass index. CONCLUSIONS: In SCAD patients undergoing myocardial revascularization, abnormal fQRSTa is independent predictor of overall and CV mortality.


Assuntos
Doença da Artéria Coronariana/fisiopatologia , Doença da Artéria Coronariana/cirurgia , Eletrocardiografia , Doenças das Valvas Cardíacas/fisiopatologia , Doenças das Valvas Cardíacas/cirurgia , Revascularização Miocárdica , Idoso , Doença da Artéria Coronariana/mortalidade , Ecocardiografia , Feminino , Doenças das Valvas Cardíacas/mortalidade , Humanos , Itália , Masculino , Valor Preditivo dos Testes , Prognóstico , Estudos Prospectivos , Sistema de Registros , Medição de Risco , Fatores de Risco , Resultado do Tratamento
11.
Cardiovasc Ultrasound ; 14(1): 35, 2016 Aug 23.
Artigo em Inglês | MEDLINE | ID: mdl-27552988

RESUMO

BACKGROUND: Previous studies showed that left atrial enlargement is an independent marker of adverse outcomes in both primary and secondary cardiovascular prevention. However, no data are available on long-term outcomes in patients undergoing valve surgery and/or coronary artery by-pass graft (CABG) surgery. Aim of the study was to evaluate long-term prognostic role of left atrial volume index (LAVi) after cardiac surgery, using the cutoff values recently proposed by the European Association of Cardiovascular Imaging and American Society of Echocardiography. METHODS: We created a retrospective registry of 1703 consecutive patients who underwent cardiovascular rehabilitation program after cardiac surgery, including CABG, valve surgery and valve + CABG surgery. LAVi was calculated as ratio of left atrium volume to body surface area, in ml/m(2) at discharge; 563 patients with available LAVi data were included in the study. RESULTS: In the whole population LAVi was 36 ± 14 ml/m(2) (mean ± SD) and the follow-up time was 5 ± 1.5 years. Increased LAVi (>34 ml/m(2)) predicted major adverse cardiovascular and cerebrovascular events (MACCEs) (HR = 2.1; CI95 %: 1.4-3.1; p < 0.001) and cardiovascular mortality (HR = 2.2; CI95 %: 1.0-4.5; p = 0.032). An increased LAVi remained MACCEs predictor after adjustement for age, gender, diabetes, atrial fibrillation at discharge, echocardiographic E/A ratio and left ventricular ejection fraction (HR = 1.8; CI95 %: 1.0-3.0; p = 0.036). When the study population was split according to increasing LAVi values, left atrium enlargement resulted a predictor of progressively worse adverse outcome. CONCLUSIONS: LAVi is a predictor of long-term adverse cardiovascular outcome after cardiac surgery, even after correction for main clinical and echocardiographic variables. The recently recommended LAVi severity cutoffs appear adequate to effectively stratify outcome in patients undergoing rehabilitation after cardiac surgery.


Assuntos
Reabilitação Cardíaca/métodos , Procedimentos Cirúrgicos Cardíacos , Doenças Cardiovasculares/fisiopatologia , Átrios do Coração/fisiopatologia , Idoso , Função do Átrio Esquerdo , Doenças Cardiovasculares/cirurgia , Ecocardiografia , Feminino , Seguimentos , Átrios do Coração/diagnóstico por imagem , Humanos , Masculino , Prognóstico , Estudos Retrospectivos , Fatores de Risco
13.
Sensors (Basel) ; 16(5)2016 May 11.
Artigo em Inglês | MEDLINE | ID: mdl-27187389

RESUMO

Bioelectrical Impedance Spectroscopy (BIS) allows assessing the composition of body districts noninvasively and quickly, potentially providing important physiological/clinical information. However, neither portable commercial instruments nor more advanced wearable prototypes simultaneously satisfy the demanding needs of unobtrusively tracking body fluid shifts in different segments simultaneously, over a broad frequency range, for long periods and with high measurements rate. These needs are often required to evaluate exercise tests in sports or rehabilitation medicine, or to assess gravitational stresses in aerospace medicine. Therefore, the aim of this work is to present a new wearable prototype for monitoring multi-segment and multi-frequency BIS unobtrusively over long periods. Our prototype guarantees low weight, small size and low power consumption. An analog board with current-injecting and voltage-sensing electrodes across three body segments interfaces a digital board that generates square-wave current stimuli and computes impedance at 10 frequencies from 1 to 796 kHz. To evaluate the information derivable from our device, we monitored the BIS of three body segments in a volunteer before, during and after physical exercise and postural shift. We show that it can describe the dynamics of exercise-induced changes and the effect of a sit-to-stand maneuver in active and inactive muscular districts separately and simultaneously.


Assuntos
Líquidos Corporais , Impedância Elétrica , Exercício Físico , Composição Corporal , Deslocamentos de Líquidos Corporais , Humanos
14.
Plant Cell Environ ; 38(9): 1866-80, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25210866

RESUMO

Maize (Zea mays ssp. mays L.) is highly susceptible to drought stress. This work focused on whole-plant physiological mechanisms by which a biotechnology-derived maize event expressing bacterial cold shock protein B (CspB), MON 87460, increased grain yield under drought. Plants of MON 87460 and a conventional control (hereafter 'control') were tested in the field under well-watered (WW) and water-limited (WL) treatments imposed during mid-vegetative to mid-reproductive stages during 2009-2011. Across years, average grain yield increased by 6% in MON 87460 compared with control under WL conditions. This was associated with higher soil water content at 0.5 m depth during the treatment phase, increased ear growth, decreased leaf area, leaf dry weight and sap flow rate during silking, increased kernel number and harvest index in MON 87460 than the control. No consistent differences were observed under WW conditions. This indicates that MON 87460 acclimated better under WL conditions than the control by lowering leaf growth which decreased water use during silking, thereby eliciting lower stress under WL conditions. These physiological responses in MON 87460 under WL conditions resulted in increased ear growth during silking, which subsequently increased the kernel number, harvest index and grain yield compared to the control.


Assuntos
Biotecnologia/métodos , Secas , Zea mays/fisiologia , Proteínas de Bactérias/genética , Grão Comestível , Folhas de Planta/fisiologia , Plantas Geneticamente Modificadas/fisiologia , Solo/química
15.
Eur J Appl Physiol ; 115(4): 825-35, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25471271

RESUMO

PURPOSE: Endurance exercise is associated with high cardiac vagal tone, but how the cardiac autonomic control correlates with shorter anaerobic performances is unknown. Therefore, the aim of this study was to evaluate how autonomic modulations of heart rate (HR) variability (V) correlate with performances of short- (<1 min) and very short (<30 s) duration in elite athletes. METHOD: Thirteen male swimmers, national-level crawl specialists in short (100-m) and very short (50-m) distances, were enrolled. HR was recorded during 15-min supine rest: (1) in the morning after wake up, (2) in the afternoon before sprint-oriented training sessions, (3) few minutes after training (first recovery phase after swimming cooldown). Heart rate variability (HRV) vagal and sympatho/vagal indices were calculated in time, frequency and complexity domains. Correlations of best seasonal times on 100- or 50-m distances with HRV indices and the velocity at blood lactate accumulation onset (V OBLA) were calculated. RESULTS AND CONCLUSION: Vagal indices were highest in the morning where they positively correlated with very short-distance times (higher the index, worse is the 50-m performance). Sympatho/vagal indices were highest after training where they negatively correlated with short-distance times (higher the index, better is the 100-m performance). V OBLA did not correlate with the performances. Therefore, autonomic HRV indices and not V OBLA predict short and very short, most anaerobic, performances. Results also suggest that a strong cardiac vagal control has no effect on short performances and is even detrimental to very short performances, and that the capacity to powerfully increase the sympathetic tone during exercise may improve short, but not very short performances.


Assuntos
Desempenho Atlético , Frequência Cardíaca , Natação/fisiologia , Nervo Vago/fisiologia , Adulto , Atletas , Humanos , Masculino , Resistência Física
16.
PLoS One ; 19(8): e0305267, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39172942

RESUMO

Little is known about the effect of using an attentional focus instruction on motor performance in people with intellectual disabilities. Therefore, this study explored the effects of different attentional focus instructions on gross motor skill performances in individuals with Down syndrome. Seven community-dwelling participants (age 25.2±3.2 yrs, height 1.70±0.04 m, body mass 72.0±6.3 kg) voluntarily participated in the study. Motor performance on 5-meter running (5m sprint), vertical jump (countermovement jump with arm swing, CMJ), broad jump (standing broad jump, SBJ), forward medball throw (FMBT) or overhead medball backward throw (OMBT) and rising-up from a chair (five repetition sit-to-stand, 5STS) were recorded while performing internal-focus (IF) or external-focus (EF) instructions. EF induced significantly (p<0.05) better performance than IF in CMJ (EF: 15±9 cm; IF: 11±8 cm, median ±interquartile range), SBJ (EF: 0.8±1.05 m; IF: 0.5±1.0 m), FMBT (EF: 1.5±1.4 m; IF: 1.4±1.1 m), OMBT (EF: 4.0±1.5 m; IF: 3.6±1.1 m) and 5STS (EF: 14.2±5.4; IF:15.3±7.7 s). The time over the 5m sprint tended to be shorter with EF (4.0±2.0 s) than IF (5.05±3.3 s) but the difference did not reach the statistical significance (p = 0.29). Physical trainers and school teachers should be encouraged to manage different types of attentional focus instructions to improve cognitive and gross motor performances in persons with Down syndrome.


Assuntos
Atenção , Estudos Cross-Over , Síndrome de Down , Destreza Motora , Humanos , Síndrome de Down/fisiopatologia , Síndrome de Down/psicologia , Adulto , Masculino , Atenção/fisiologia , Feminino , Destreza Motora/fisiologia , Adulto Jovem
17.
J Clin Med ; 13(14)2024 Jul 16.
Artigo em Inglês | MEDLINE | ID: mdl-39064202

RESUMO

Background: Multisystem Inflammatory Syndrome in Children (MIS-C) has emerged as a severe pediatric complication during the SARS-CoV-2 pandemic, with potential long-term cardiovascular repercussions. We hypothesized that heart rate and blood pressure control at rest and during postural maneuvers in MIS-C patients, months after the remission of the inflammatory syndrome, may reveal long-term autonomic dysfunctions. Methods: We assessed 17 MIS-C patients (13 males; 11.9 ± 2.6 years, m ± SD) 9 months after acute infection and 18 age- (12.5 ± 2.1 years) and sex- (13 males) matched controls. Heart rate and blood pressure variability, baroreflex function, and hemodynamic parameters were analyzed in supine and standing postures. Results: MIS-C patients exhibited reduced heart rate variability, particularly in parasympathetic parameters during standing (pNN50+: 6.1 ± 6.4% in controls, 2.5 ± 3.9% in MIS-C; RMSSD: 34 ± 19 ms in controls, 21 ± 14 ms in MIS-C, p < 0.05), with no interaction between case and posture. Blood pressure variability and baroreflex sensitivity did not differ between groups except for the high-frequency power in systolic blood pressure (3.3 ± 1.2 mmHg2 in controls, 1.8 ± 1.2 mmHg2 in MIS-C, p < 0.05). The MIS-C group also showed lower diastolic pressure-time indices (DPTI) and systolic pressure-time indices (SPTI), particularly in standing (DPTI: 36.2 ± 9.4 mmHg·s in controls, 29.4 ± 6.2 mmHg·s in MIS-C; SPTI: 26.5 ± 4.3 mmHg·s in controls, 23.9 ± 2.4 mmHg·s in MIS-C, p < 0.05). Conclusions: Altered cardiovascular autonomic control may persist in MIS-C patients with, however, compensatory mechanisms that may help maintain cardiovascular homeostasis during light autonomic challenges, such as postural maneuvers. These results highlight the importance of assessing long-term cardiovascular autonomic control in children with MIS-C to possibly identify residual cardiovascular risks and inform targeted interventions and rehabilitation protocols.

18.
J Sleep Res ; 22(3): 322-30, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23294420

RESUMO

High-altitude exposure is characterized by the appearance of periodic breathing during sleep. Only limited evidence is available, however, on the presence of gender-related differences in this breathing pattern. In 37 healthy subjects, 23 male and 14 female, we performed nocturnal cardio-respiratory monitoring in the following conditions: (1) sea level; (2) first/second night at an altitude of 3400 m; (3) first/second night at an altitude of 5400 m and after a 10 day sojourn at 5400 m. At sea level, a normal breathing pattern was observed in all subjects throughout the night. At 3400 m the apnea-hypopnea index was 40.3 ± 33.0 in males (central apneas 77.6%, central hypopneas 22.4%) and 2.4 ± 2.8 in females (central apneas 58.2%, central hypopneas 41.8%; P < 0.01). During the first recording at 5400 m, the apnea-hypopnea index was 87.5 ± 35.7 in males (central apneas 60.0%, central hypopneas 40.0%) and 41.1 ± 44.0 in females (central apneas 73.2%, central hypopneas 26.8%; P < 0.01), again with a higher frequency of central events in males as seen at lower altitude. Similar results were observed after 10 days. With increasing altitude, there was also a progressive reduction in respiratory cycle length during central apneas in males (26.9 ± 3.4 s at 3400 m and 22.6 ± 3.7 s at 5400 m). Females, who displayed a significant number of central apneas only at the highest reached altitude, were characterized by longer cycle length than males at similar altitude (30.1 ± 5.8 s at 5400 m). In conclusion, at high altitude, nocturnal periodic breathing affects males more than females. Females started to present a significant number of central sleep apneas only at the highest reached altitude. After 10 days at 5400 m gender differences in the apnea-hypopnea index similar to those observed after acute exposure were still observed, accompanied by differences in respiratory cycle length.


Assuntos
Hipóxia/complicações , Monitorização Ambulatorial/instrumentação , Apneia do Sono Tipo Central/fisiopatologia , Sono/fisiologia , Actigrafia , Adulto , Altitude , Doença da Altitude/tratamento farmacológico , Doença da Altitude/etiologia , Doença da Altitude/fisiopatologia , Bloqueadores do Receptor Tipo 1 de Angiotensina II/administração & dosagem , Bloqueadores do Receptor Tipo 1 de Angiotensina II/farmacologia , Pressão Atmosférica , Benzimidazóis/administração & dosagem , Benzimidazóis/farmacologia , Benzoatos/administração & dosagem , Benzoatos/farmacologia , Monitorização Ambulatorial da Pressão Arterial/instrumentação , Método Duplo-Cego , Feminino , Frequência Cardíaca/fisiologia , Humanos , Hipóxia/etiologia , Masculino , Pessoa de Meia-Idade , Monitorização Ambulatorial/normas , Oxigênio/sangue , Placebos , Taxa Respiratória/fisiologia , Índice de Gravidade de Doença , Fatores Sexuais , Apneia do Sono Tipo Central/tratamento farmacológico , Apneia do Sono Tipo Central/etiologia , Telmisartan , Fatores de Tempo
19.
Europace ; 15(4): 607-12, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23258818

RESUMO

AIMS: We developed a textile-based wearable system, named MagIC, for the unobtrusive monitoring of one electrocardiogram (ECG) lead, respiratory frequency and motion. In the present study, we investigated the ability of this system to monitor cardiac rhythm and arrhythmic events in cardiac patients. METHODS AND RESULTS: The study was carried out by comparing ECG tracings simultaneously recorded by MagIC and traditional ECG devices (Trad-ECG) in 40 cardiac patients at rest and during physical exercise. Data were manually scored by two cardiologists. At rest the artefact rates observed with MagIC and Trad-ECG were virtually identical (1.4% of the registered signal); while during physical exercise the artefact rate observed with MagIC was much lower than with Trad-ECG (4.07 vs. 17.31%). Recordings from MagIC allowed a correct identification of the type of rhythm in the vast majority of patients (92.5%) and an estimation of PQ interval and QRS duration similar to Trad-ECG (<0.016 s). MagIC displayed a good performance in detecting arrhythmias, with only 14 misclassified events out of 3618, and both specificity and sensitivity being above 99%. No practical difference was observed in the estimation of the beat-by-beat RR interval by the two methods. CONCLUSION: This study indicates that in static condition MagIC has a capability of monitoring cardiac rhythm and arrhythmic events which is comparable with what obtainable by a traditional one-lead ECG recorder. During movement MagIC provides an ECG signal of better quality.


Assuntos
Arritmias Cardíacas/diagnóstico , Vestuário , Eletrocardiografia Ambulatorial/instrumentação , Telemetria/instrumentação , Têxteis , Transdutores , Adulto , Idoso , Idoso de 80 Anos ou mais , Arritmias Cardíacas/fisiopatologia , Artefatos , Desenho de Equipamento , Teste de Esforço , Humanos , Masculino , Pessoa de Meia-Idade , Satisfação do Paciente , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Taxa Respiratória , Processamento de Sinais Assistido por Computador
20.
Sci Rep ; 13(1): 2220, 2023 02 08.
Artigo em Inglês | MEDLINE | ID: mdl-36755066

RESUMO

Little is known on the effects of respiratory patterns on baroreflex function in heart failure (HF). Patients with HF (n = 30, age 61.6 ± 10 years, mean ± SD) and healthy controls (CNT, n = 10, age 58.9 ± 5.6 years) having their R-R interval (RRI, EKG), systolic arterial blood pressure (SBP, Finapres) and respiratory signal (RSP, Respitrace) monitored, were subjected to three recording sessions: free-breathing, fast- (≥ 12 bpm) and slow- (6 bpm) paced breathing. Baroreflex sensitivity (BRS) and power spectra of RRI, SBP, and RSP signals were calculated. During free-breathing, compared to CNT, HF patients showed a significantly greater modulation of respiratory volumes in the very-low-frequency (< 0.04 Hz) range and their BRS was not significantly different from that of CNT. During fast-paced breathing, when very-low-frequency modulations of respiration were reduced, BRS of HF patients was significantly lower than that of CNT and lower than during free breathing. During slow-paced breathing, BRS became again significantly higher than during fast breathing. In conclusion: (1) in free-breathing HF patients is present a greater modulation of respiratory volumes in the very-low-frequency range; (2) in HF patients modulation of respiration in the very-low and low frequency (around 0.1 Hz) ranges contributes to preserve baroreflex-mediated control of heart rate.


Assuntos
Barorreflexo , Insuficiência Cardíaca , Humanos , Pessoa de Meia-Idade , Idoso , Barorreflexo/fisiologia , Pressão Sanguínea/fisiologia , Respiração , Taxa Respiratória/fisiologia , Frequência Cardíaca/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA