Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
1.
Cardiol Young ; 26(7): 1445-7, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27323215

RESUMO

Cardiac rhythm monitoring has been facilitated by the use of implantable loop recorders. New models of these devices are 87% smaller than before allowing for easier implantation and use in the paediatric population. Recommendations are for closure with adhesive. We report a device extrusion in a 6-year-old patient. Based on this, our practice has changed to include subcutaneous sutures this complication.


Assuntos
Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/terapia , Desfibriladores Implantáveis/efeitos adversos , Desenho de Equipamento/normas , Falha de Prótese , Criança , Eletrocardiografia , Humanos , Masculino
2.
J Interv Card Electrophysiol ; 48(3): 369-374, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28091832

RESUMO

PURPOSE: The atrial transseptal procedure is used in catheter ablation of left-sided arrhythmias. Studies in adult patients have shown the SafeSept™ transseptal guidewire (SSTG) to be effective in atrial transseptal procedures. We analyzed our 5-year experience with SSTG use in pediatric and congenital heart disease patients undergoing catheter ablation. METHODS: This is a single-center retrospective analysis of patients undergoing catheter ablation from 2009 to 2014. We identified all procedures where SSTG was used for atrial transseptal or trans-baffle access. Success of transseptal access and complications were recorded and compared to the standard transseptal approach without the SSTG. RESULTS: One hundred twenty-seven patients underwent 132 attempted atrial transseptal or trans-baffle procedures using SSTG. Median age was 14 (1.2-38) years. Arrhythmia substrates included AV reentrant tachycardia (90.2%), atrial tachycardia (4.5%), ventricular tachycardia (2.3%), and AV nodal reentrant tachycardia (2.3%). Transseptal or trans-baffle access was successful in 96.2% of the SSTG cases compared to 98.9% in the standard transseptal group without SSTG (p = NS). The youngest patient with successful atrial transseptal procedure using SSTG was 4 years old. SSTG was used to successfully cross a surgically created atrial baffle in a patient who had undergone the Mustard procedure. There was one major complication in both groups, 0.8% in the SSTG group compared to the standard transseptal group without SSTG, 1.1% (p = NS). The major complication in the SSTG group occurred when the SSTG crossed the aorta into the coronary artery system and mimicked placement in the left atrial appendage, with subsequent placement of a transseptal sheath into the aorta, requiring sternotomy and surgical intervention. CONCLUSIONS: SSTG is effective for use in atrial transseptal and surgical trans-baffle access in pediatric and congenital heart disease patients. Placement of the SSTG into the pulmonary vein is necessary to avoid major complications, and if not achieved requires additional methods to determine appropriate left atrial placement.


Assuntos
Septo Interatrial/diagnóstico por imagem , Septo Interatrial/cirurgia , Mapeamento Potencial de Superfície Corporal/instrumentação , Ablação por Cateter/instrumentação , Cardiopatias Congênitas/epidemiologia , Cardiopatias Congênitas/cirurgia , Complicações Pós-Operatórias/epidemiologia , Adolescente , Adulto , Criança , Pré-Escolar , Desenho de Equipamento , Análise de Falha de Equipamento , Feminino , Marcadores Fiduciais , Cardiopatias Congênitas/diagnóstico , Humanos , Lactente , Masculino , Ohio/epidemiologia , Complicações Pós-Operatórias/prevenção & controle , Prevalência , Estudos Retrospectivos , Fatores de Risco , Cirurgia Assistida por Computador/instrumentação , Resultado do Tratamento , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA