Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 246
Filtrar
1.
Nano Lett ; 24(17): 5292-5300, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38648075

RESUMO

Understanding the structure-property relationship of lithium-ion conducting solid oxide electrolytes is essential to accelerate their development and commercialization. However, the structural complexity of nonideal materials increases the difficulty of study. Here, we develop an algorithmic framework to understand the effect of microstructure on the properties by linking the microscopic morphology images to their ionic conductivities. We adopt garnet and perovskite polycrystalline oxides as examples and quantify the microscopic morphologies via extracting determined physical parameters from the images. It directly visualizes the effect of physical parameters on their corresponding ionic conductivities. As a result, we can determine the microstructural features of a Li-ion conductor with high ionic conductivity, which can guide the synthesis of highly conductive solid electrolytes. Our work provides a novel approach to understanding the microstructure-property relationship for solid-state ionic materials, showing the potential to extend to other structural/functional ceramics with various physical properties in other fields.

2.
Artigo em Inglês | MEDLINE | ID: mdl-38750671

RESUMO

BACKGROUND: Management of atrial fibrillation (AF) in very severe obese patients is challenging. Cryoballoon ablation (CBA) represents an effective rhythm control strategy. However, data in this patient group were limited. METHODS: Highly symptomatic AF patients with body mass index (BMI) ≥ 40 kg/m2 who had failed antiarrhythmic drug therapy and electrocardioversion and failure to achieve targeted body-weight-reduction underwent CBA. RESULTS: Data of 72 very severe obese AF patients (Group A) and 129 AF patients with normal BMI (Group B, BMI < 25 kg/m2) were consecutively collected. Group A had significantly younger age (60.6 ± 10.4 vs. 69.2 ± 11.2 years), higher BMI (44.3 ± 4.3 vs. 22.5 ± 1.6 kg/m2). Procedural pulmonary vein isolation (PVI) was successful in all patients (2 touch-up ablation in Group A). Compared to Group B, Group A had similar procedural (61.3 ± 22.6 vs. 57.5 ± 19 min), similar fluoroscopy time (10.1 ± 5.5 vs. 9.2 ± 4.8 min) but significantly higher radiation dose (2852 ± 2095 vs. 884 ± 732 µGym2). We observed similar rates of real-time-isolation (78.6% vs. 78.5%), single-shot-isolation (86.5% vs. 88.8%), but significantly longer time-to-sustained-isolation (53.5 ± 33 vs. 43.2 ± 25 s). There was significantly higher rate of puncture-site-complication (6.9% vs. 1.6%) in Group A. One-year clinical success in paroxysmal AF was (Group A: 69.4% vs. Group B: 80.2%; p < .001), in persistent AF was (Group A: 58.1% vs. Group B: 62.8%; p = .889). In Re-Do procedures Group A had a numerically lower PVI durability (75.0% vs. 83.6%, p = .089). CONCLUSION: For very severe obese AF patients, CBA appears feasible, leads to relatively good clinical outcome.

3.
Cardiovasc Diabetol ; 23(1): 78, 2024 02 24.
Artigo em Inglês | MEDLINE | ID: mdl-38402177

RESUMO

OBJECTIVE: We aimed to assess the effect of SGLT2i on arrhythmias by conducting a meta-analysis using data from randomized controlled trials(RCTs). BACKGROUND: Sodium-glucose co-transporter 2 inhibitors (SGLT2i) have shown cardioprotective effects via multiple mechanisms that may also contribute to decrease arrhythmias risk. METHODS: We searched in databases (PubMed, Embase, Cochrane Library, and clinicaltrials.gov) up to April 2023. RCTs comparing SGLT2i with placebo were included. The effects of SGLT2i on atrial fibrillation(AF), atrial flutter(AFL), composite AF/AFL, ventricular fibrillation(VF), ventricular tachycardia(VT), ventricular extrasystoles(VES), sudden cardiac death(SCD) and composite VF/VT/SCD were evaluated. RESULTS: 33 placebo-controlled RCTs were included, comprising 88,098 patients (48,585 in SGLT2i vs. 39,513 in placebo). The mean age was 64.9 ± 9.4 years, 63.0% were male. The mean follow-up was 1.4 ± 1.1 years. The pooled-results showed that SGLT2i was associated with a significantly lower risk of AF [risk ratio(RR): 0.88, 95% confidence interval(CI) 0.78-1.00, P = 0.04] and composite AF/AFL (RR: 0.86, 95%CI 0.77-0.96, P = 0.01). This favorable effect appeared to be substantially pronounced in patients with HFrEF, male gender, dapagliflozin, and > 1 year follow-up. For SCD, only in heart failure patients, SGLT2i were found to be associated with a borderline lower risk of SCD (RR: 0.67, P = 0.05). No significant effects of SGLT2i on other ventricular arrhythmic outcomes were found. CONCLUSIONS: SGLT2i lowers the risks of AF and AF/AFL, and this favorable effect appeared to be particularly pronounced in patients with HFrEF, male gender, dapagliflozin, and longer follow-up (> 1 year). SGLT2i lowers the risk of SCD only in heart failure patients.


Assuntos
Fibrilação Atrial , Compostos Benzidrílicos , Glucosídeos , Insuficiência Cardíaca , Inibidores do Transportador 2 de Sódio-Glicose , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Feminino , Inibidores do Transportador 2 de Sódio-Glicose/efeitos adversos , Volume Sistólico , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Fibrilação Ventricular
4.
Nano Lett ; 23(3): 887-894, 2023 Feb 08.
Artigo em Inglês | MEDLINE | ID: mdl-36648987

RESUMO

The microstructure of the Li7La3Zr2O12 (LLZO) garnet solid electrolyte is critical for its performance in all-solid-state lithium-ion battery. During conventional high-temperature sintering, second phases are generated at the grain boundaries due to the reaction between sintering aids and LLZO, which have an enormous effect on the performances of LLZO. However, a detailed structure study of the second phases and their impact on physical properties is lacking. Here, crystal structures of the second phases in LLZO pellets are studied in detail by transmission electron microscopy. Three different crystal structures of Li-Al-O second phases, γ-LiAlO2, α-Li5AlO4, and ß-Li5AlO4 were identified, and atomic-scale lattice information was obtained by applying low-dose high-resolution imaging for these electron-beam-sensitive second phases. On this basis, the structure-property relationship of these structures was explored. It was found that sintering aids with a higher Li/Al ratio are beneficial to form Li-rich second phases, which result in more highly ionic conductive LLZO.

5.
J Sci Food Agric ; 104(5): 3069-3079, 2024 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-38072654

RESUMO

BACKGROUND: ε-polylysine hydrochloride (ε-PLH) is a naturally occurring antimicrobial peptide extensively utilized in the food and medical industries. However, its impact on animal husbandry remains to be further explored. Therefore, the present study aimed to determine the effect of ε-PLH on laying hens' health and laying performance. RESULTS: Dietary supplementation with ε-PLH to the diet significantly increased average egg weight during weeks 1-8. Meanwhile, compared with the control group, supplementation with ε-PLH decreased the feed egg ratio during weeks 9-12 and egg breakage rate during weeks 9-16 ,whereas it increased eggshell strength during weeks 1-4 and 13-16 . The ε-PLH 0.05% group increased yolk percentage during weeks 5-8 and yolk color during weeks 1-4 . Furthermore, ε-PLH supplementation significantly increased the concentrations of total protein, albumin, globulin and reproductive hormones estradiol, as well as decreased interleukin-1 beta and malondialdehyde in the serum. Compared with the control group, supplementation with 0.05% ε-PLH significantly increased the relative abundance of Cyanobacteria and Gastranaerophilales and decreased the abundance of Desulfovibrio and Streptococcus in the cecum microbiota. In addition, ε-PLH 0.1% supplementation also increased acetic acid content in the cecum. CONCLUSION: Dietary supplementation with ε-PLH has a positive impact on both productive performance and egg quality in laying hens. Furthermore, ε-PLH can also relieve inflammation by promoting the immunity and reducing oxidative damage during egg production. ε-PLH has been shown to improve intestinal morphology, gut microbial diversity and intestinal health. © 2023 Society of Chemical Industry.


Assuntos
Microbioma Gastrointestinal , Animais , Feminino , Polilisina/farmacologia , Galinhas/microbiologia , Suplementos Nutricionais/análise , Dieta/veterinária , Ácidos Graxos Voláteis , Ração Animal/análise
6.
J Transl Med ; 21(1): 43, 2023 01 23.
Artigo em Inglês | MEDLINE | ID: mdl-36691046

RESUMO

BACKGROUND: Intrahepatic cholangiocarcinoma (ICC) is a malignant disease characterized by onset occult, rapid progression, high relapse rate, and high mortality. However, data on how the tumor microenvironment (TME) regulates ICC metastasis at the transcriptomic level remains unclear. This study aimed to explore the mechanisms and interactions between hepatocytes and ICC cells. METHODS: We analyzed the interplay between ICC and liver microenvironment through cytokine antibody array analysis. Then we investigated the role of N6-methyladenosine (m6A) modification and the downstream target in vitro, in vivo experiments, and in clinical specimens. RESULTS: Our study demonstrated that cytokine CCL3, which is secreted by hepatocytes, promotes tumor metastasis by regulating m6A modification via vir-like m6A methyltransferase associated (VIRMA) in ICC cells. Moreover, immunohistochemical analyses showed that VIRMA correlated with poor outcomes in ICC patients. Finally, we confirmed both in vitro and in vivo that CCL3 could activate VIRMA and its critical downstream target SIRT1, which fuels tumor metastasis in ICC. CONCLUSIONS: In conclusion, our results enhanced our understanding of the interaction between hepatocytes and ICC cells, and revealed the molecular mechanism of the CCL3/VIRMA/SIRT1 pathway via m6A-mediated regulation in ICC metastasis. These studies highlight potential targets for the diagnosis, treatment, and prognosis of ICC.


Assuntos
Neoplasias dos Ductos Biliares , Colangiocarcinoma , Humanos , Sirtuína 1 , Recidiva Local de Neoplasia , Colangiocarcinoma/metabolismo , Prognóstico , Ductos Biliares Intra-Hepáticos/metabolismo , Neoplasias dos Ductos Biliares/metabolismo , Hepatócitos/patologia , Citocinas , Linhagem Celular Tumoral , Microambiente Tumoral
7.
J Cardiovasc Electrophysiol ; 34(12): 2599-2606, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37968834

RESUMO

Radiofrequency (RF) ablation of intramural ventricular arrhythmias (VAs) may require advanced ablation techniques to achieve effective energy transfer to the targeted tissue. As an alternative to standard RF ablation, catheter ablation can also be conducted in bipolar configuration when two ablation catheters participate in the RF circuit. This strategy has proved to result in deeper lesion formation and may be effective for eliminating arrhythmias that have been refractory to standard ablation. In this article, we provide a step-by-step guide on when and how to perform bipolar ablation of VAs.


Assuntos
Técnicas de Ablação , Ablação por Cateter , Taquicardia Ventricular , Humanos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirurgia , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos
8.
J Cardiovasc Electrophysiol ; 34(1): 117-125, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36403284

RESUMO

INTRODUCTION: Intramural or epicardial locations of the arrhythmogenic substrate are regarded as one of the main reasons for radiofrequency (RF) catheter ablation failure. This study aims to conduct a comprehensive analysis of various factors including baseline impedance, irrigant and electrode configuration at similar ablation index (AI) value. METHODS: In 12 ex vivo swine hearts, RF ablation was performed at a target AI value of 500 and a multistep impedance load (100-180 Ω) in 4 settings: (1) conventional unipolar configuration with an irrigant of normal saline (NS); (2) conventional unipolar configuration with an irrigant of half normal saline (HNS); (3) bipolar configuration with an irrigant of NS; (4) sequential unipolar configuration with an irrigant of NS. The relationships between lesion dimensions and above factors were examined. RESULTS: Baseline impedance had a strong negative linear correlation with lesion dimensions at a certain AI. The correlation coefficient between baseline impedance and depth, width, and volume were R = -0.890, R = -0.755 and R = -0.813, respectively (p < .01). There were 10 (total: 10/100, 10%; bipolar: 10/25, 40%) transmural lesions during the whole procedure. Bipolar ablation resulted in significantly deeper lesion than other electrode configurations. Other comparisons in our experiment did not achieve statistical significance. CONCLUSION: There is a strong negative linear correlation between baseline impedance and lesion dimensions at a certain AI value. Baseline impedance has an influence on the overall lesion dimensions among irrigated fluid and ablation configurations. Over a threshold impedance of 150 Ω, the predictive accuracy of AI can be compromised.


Assuntos
Ablação por Cateter , Solução Salina , Suínos , Animais , Impedância Elétrica , Coração , Eletrodos , Arritmias Cardíacas , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos
9.
J Cardiovasc Electrophysiol ; 34(12): 2425-2433, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37767744

RESUMO

INTRODUCTION: Pulsed field ablation (PFA) is a new ablation technology for atrial fibrillation (AF). Data regarding early recurrences of atrial tachyarrhythmia (ERAT) after PFA-pulmonary vein isolation (PVI) are sparse. METHODS: Consecutive patients with symptomatic AF were enrolled to undergo PFA-PVI. A dedicated catheter delivering bipolar energy (1.9-2.0 kV) was used. Late recurrence (LR) was defined as documented AF/atrial tachycardia (AT) lasting more than 30 s after a 90-day blanking period. RESULTS: Two hundred and thirty-one patients (42% female, age 69 ± 12, 55% paroxysmal AF [PAF]) were included in this analysis. Median follow-up time was 367 days (interquartile range: 253-400). Forty-six patients (21%) experienced ERAT after a median of 23 days (46% in PAF and 54% in persistent AF [persAF]). Kaplan-Meier estimated freedom of AF/AT was 74.2% at 1 year, 81.8% for PAF, and 64.8% for persAF (p = .0079). Of patients experiencing ERAT, an LR was observed in 54%. There was no significant difference of LR between those who presented with very early ERAT (0-45 days) and those with ERAT (46-90 days) (p = .57). In multivariate analysis, ERAT (hazard ratio [HR]: 3.370; 95% confidence interval [95% CI]: 1.851-6.136; p < .001) and female sex (HR: 2.048; 95% CI: 1.114-3.768; p = .021) were the only independent predictors for LR. CONCLUSIONS: ERAT could be recorded in 21% of patients after PFA-PVI and was an independent predictor for LR. We found no difference in the rate of LRs among patients experiencing ERAT before or after 45 days.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Taquicardia Supraventricular , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Masculino , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Resultado do Tratamento , Fatores de Tempo , Recidiva , Átrios do Coração , Ablação por Cateter/efeitos adversos , Veias Pulmonares/cirurgia
10.
Pharmacol Res ; 187: 106555, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36403721

RESUMO

BACKGROUND: Perineural invasion (PNI) has a high incidence and poor prognosis in pancreatic ductal adenocarcinoma (PDAC). Our study aimed to identify the underlying molecular mechanism of PNI and propose effective intervention strategies. METHODS: To observe PNI in vitro and in vivo, a Matrigel/ dorsal root ganglia (DRG) model and a murine sciatic nerve invasion model were respectively used. Magnetic resonance (MR) imaging and positron emission tomography/computed tomography (PET-CT) imaging were also used to evaluate tumor growth. Publicly available datasets and PDAC tissues were used to verify how the nerve cells regulate PDAC cells' PNI. RESULTS: Our results showed that glutamate from nerve cells could cause calcium influx in PDAC cells via the N-methyl-d-aspartate receptor (NMDAR), subsequently activating the downstream Ca2+ dependent protein kinase CaMKII/ERK-MAPK pathway and promoting the mRNA transcription of gene METTL3. Next, METTL3 upregulates the expression of hexokinase 2 (HK2) through N6-methyladenosine (m6A) modification in mRNA, enhances the PDAC cells' glycolysis, and promotes PNI. Furthermore, the IONPs-PEG-scFvCD44v6-scAbNMDAR2B nanoparticles dual targeting CD44 variant isoform 6 (CD44v6) and t NMDAR subunit 2B (NMDAR2B) on PDAC cells were synthesized and verified showing a satisfactory blocking effect on PNI. CONCLUSIONS: Here, we firstly provided evidence that glutamate from the nerve cells could upregulate the expression of HK2 through mRNA m6A modification via NMDAR2B and downstream Ca2+ dependent CaMKII/ERK-MAPK pathway, enhance the glycolysis in PDAC cells, and ultimately promote PNI. In addition, the dual targeting nanoparticles we synthesized were verified to block PNI effectively in PDAC.


Assuntos
Carcinoma Ductal Pancreático , Neoplasias Pancreáticas , Camundongos , Animais , Ácido Glutâmico , Hexoquinase , Proteína Quinase Tipo 2 Dependente de Cálcio-Calmodulina , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Invasividade Neoplásica , Neoplasias Pancreáticas/metabolismo , Carcinoma Ductal Pancreático/genética , Carcinoma Ductal Pancreático/metabolismo , Neurônios/metabolismo , Linhagem Celular Tumoral , Neoplasias Pancreáticas
11.
Europace ; 25(2): 433-440, 2023 02 16.
Artigo em Inglês | MEDLINE | ID: mdl-36427201

RESUMO

AIMS: Pulsed-field ablation (PFA) can offer a novel perspective for atrial fibrillation (AF) ablation. We aimed to characterize the incidence of pulmonary vein (PV) reconnection, types of recurrent atrial tachyarrhythmia (ATa) and lesion quality after PFA-guided PV isolation (PVI). METHODS AND RESULTS: Patients undergoing second ablation for recurrent ATa following the initial PVI using the pentaspline PFA catheter were investigated. The rate of PV reconnection, the features of recurrent ATa, and the amount of isolated posterior wall (PW) surface area (ISAPW%) (ratio of the isolated- to total surface area on PW) were analyzed. RESULTS: Among 360 patients treated with PFA, 25 patients (paroxysmal AF, n = 19) with 99 PVs underwent a second procedure 6.1 ± 4.0 months after the initial procedure. The rate of PV reconnection was 9.1% (9 PVs). Patients presented with atrial tachycardia (AT) (n = 16), AF (n = 8) and typical atrial flutter (n = 1). The mechanism of all but one AT was macro-reentry. The critical isthmus was found to be linked to the initial lesion set at the left atrial (LA) PW in eight patients and linked to pre-existing substrate at the LA anterior wall in four patients. One AT had a focal origin at the septum. In three patients, AT were unmappable. Mean ISAPW% was 72.7 ± 19.0%. CONCLUSION: We revealed a remarkable low reconnection rate with a large antral lesion at the PW after pentaspline PFA catheter-guided PVI. However, macro-reentrant AT with a critical isthmus at the LAPW linked to the PVI lesion set was commonly observed.


Assuntos
Fibrilação Atrial , Flutter Atrial , Ablação por Cateter , Veias Pulmonares , Taquicardia Supraventricular , Humanos , Veias Pulmonares/cirurgia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/etiologia , Átrios do Coração , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Recidiva , Resultado do Tratamento
12.
Europace ; 25(5)2023 05 19.
Artigo em Inglês | MEDLINE | ID: mdl-37116126

RESUMO

AIMS: A novel irrigated radiofrequency (RF) balloon (RFB) for pulmonary vein (PV) isolation (PVI) was released in selected centres. We pooled the procedural data on efficacy and safety of RFB-PVI from two high volume German centres. METHODS AND RESULTS: Consecutive patients with RFB procedures were enrolled. A 3D electroanatomical left atrial map guided the RFB navigation. Every RF delivery lasted 60 s, and duration was automatically reduced to 20 s for electrodes facing the posterior wall. Procedural data and post-procedural endoscopy data (<48 h) were analysed. Data from 140 patients were collected (57% male, 67 ± 11 years, 57% paroxysmal atrial fibrillation). There were 547 PVs identified, and 99.1% could be isolated using solely the RFB. Single-shot PVI was recorded in 330/547 (60%) PVs. Median time to isolation during the first application was 10 s (IQR 8-13). A total of 2.1 ± 1.8 applications per PV were delivered, with the left superior PV requiring more application compared to other PVs. Median procedure and fluoroscopy time were 77 min (61-99) and 13 min (10-17), respectively. Major safety events were recorded only in the first 25 cases at each centre and included 1/140(0.7%) cardiac tamponade, 1/140(0.7%) phrenic nerve palsy, and 2/140 strokes (1.4%). An oesophageal temperature rise was recorded in 81/547 (15%) PVs, and endoscopy detected oesophageal lesions in 7/85 (8%) patients undergoing endoscopy. CONCLUSION: The RFB showed a high efficacy allowing for fast PVI procedures, and 60% of PVs could be isolated at the first application. Most safety events were recorded during the learning phase. An oesophageal temperature monitoring is suggested: oesophageal lesions were detected in 8% of patients.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Masculino , Feminino , Resultado do Tratamento , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/etiologia , Átrios do Coração , Veias Pulmonares/cirurgia
13.
Pacing Clin Electrophysiol ; 46(5): 414-418, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36424836

RESUMO

Pulsed field ablation (PFA) using high-voltage electrical energy is a novel and powerful ablation modality. However, PFA as a first-line rhythm control in atrial fibrillation (AF) has been rarely described; whether PFA interacts with the pacemaker (PM) has been seldom reported. We reported PFA of AF in a patient with PM who needed effective rhythm control. Pulmonary vein isolation (PVI) was successfully performed without complication, and the procedure was extremely fast (skin-to-skin 25 min.) with short fluoroscopic time (3.9 min). PFA had no influence on the PM function. Six months' follow-up showed good clinical outcome and significantly decreased AF burden.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Resultado do Tratamento , Ablação por Cateter/métodos , Veias Pulmonares/cirurgia , Recidiva
14.
J Cardiovasc Electrophysiol ; 33(7): 1371-1379, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35488736

RESUMO

BACKGROUND: The iCLAS ultra-low temperature cryoablation (ULTC) system has recently been brought to the market. A combination of a newly exploited cryogen and interchangeable stylet enables flexible and continuous lesion creation in atrial fibrillation (AF) ablation. The use of an esophageal warming balloon is recommended when using the system to reduce the potential for collateral esophageal injury. OBJECTIVE: To describe the initial clinical experience when using ULTC in the AF treatment without general anesthesia (GA). METHODS: Consecutive patients undergoing AF ablation using ULTC under deep sedation without GA were enrolled. We assessed the procedural data focusing on "single-shot isolation" defined as successful pulmonary vein (PV) isolation after the first application. Esophagogastroduodenoscopy was systematically performed the day after ablation. RESULTS: A total of 27 AF patients (67% paroxysmal AF) were analyzed. Onehundred four out of 106 PVs (98.1%) were isolated solely using ULTC. The mean procedure time was 79 ± 30 min. The mean number of applications per PV was 2.6 ± 1.0. Single-shot isolation was achieved in 57 PVs (54%) varying across PVs from left superior to inferior PVs (40%-64%). The single procedure 6-month recurrence-free rate was 84%. No major complication (cerebrovascular event, pericardial effusion/tamponade, esophageal damage on esophagogastroduodenoscopy) occurred. A single transient phrenic nerve palsy occurred during the right superior PV ablation, which had recovered by the 3-month follow-up appointment. CONCLUSIONS: AF ablation using the novel ULTC system seemed feasible without GA and enabled a >50% single-shot isolation rate. The promising safety profile has to be confirmed in large-scale studies.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Catéteres , Criocirurgia/efeitos adversos , Criocirurgia/métodos , Humanos , Veias Pulmonares/cirurgia , Temperatura , Resultado do Tratamento
15.
J Cardiovasc Electrophysiol ; 33(6): 1106-1115, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35355367

RESUMO

INTRODUCTION: Ablation of atrial fibrillation in the context of obesity can be challenging. We sought to evaluate the role of cryoballoon pulmonary vein isolation (CB-PVI) in obese patients with symptomatic atrial fibrillation (AF). METHODS: Patients with a BMI ≥ 25 kg/m2 and symptomatic AF who underwent CB-PVI were retrospectively enrolled. Three groups were defined (G1: BMI of 25-29 kg/m2 ; G2: BMI of 30-34 kg/m2 ; G3: BMI ≥ 35 kg/m2 ). RESULTS: 600 patients were included (59% male; 66 ± 11 years old); 337, 149, and 114 were assigned to G1, G2, and G3, respectively. Acute procedural success was recorded in 99.7% of patients. Procedural and fluoroscopy time were comparable but the radiation dose was significantly higher in G3. Procedural complications were 3% in G1, 5.4% in G2, and 8.8% in G3 (p = .01). The overall freedom from AF after 1-year was 77%. G3 had a significantly worse 1-year success rate compared to G1 and G2 (G3: 66.5% vs. G1: 78.4%; p = .015 and vs. G2: 82.5%; p = .008) with reduced 1-year success in paroxysmal AF (G1: 84.0%; G2: 86.3%; and G3: 69.6%) but not in persistent AF (G1: 68.7%; G2: 77.4%; and G3: 62.1%). G3 showed similar success rates irrespective of AF form (PAF: 69.6% vs. persAF 62.1%; p = .501). CONCLUSION: Cryoballoon ablation in obese patients can be effective with an acceptable safety profile, 77% of patients were in stable SR at 1 year. Severe obese patients (BMI ≥ 35) showed reduced procedural safety and 1-year success rate. In association with life style modification, CB ablation may represent a strategy to enhance rhythm control in the context of obesity.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Idoso , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Índice de Massa Corporal , Ablação por Cateter/efeitos adversos , Criocirurgia/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Obesidade/complicações , Obesidade/diagnóstico , Veias Pulmonares/cirurgia , Recidiva , Estudos Retrospectivos , Resultado do Tratamento
16.
Europace ; 24(4): 538-551, 2022 04 05.
Artigo em Inglês | MEDLINE | ID: mdl-34967892

RESUMO

Worldwide, ∼4 million people die from sudden cardiac death every year caused in more than half of the cases by ischaemic cardiomyopathy (ICM). Prevention of sudden cardiac death after myocardial infarction by implantation of a cardioverter-defibrillator (ICD) is the most common, even though not curative, therapy to date. Optimized ICD programming should be strived for in order to decrease the incidence of ICD interventions. Catheter ablation reduces the recurrence of ventricular tachycardias (VTs) and is an important adjunct to sole ICD-based treatment or pharmacological antiarrhythmic therapy in patients with ICM, as conclusively demonstrated by seven randomized controlled trials (RCTs) in the last two decades. However, none of the conducted trials was powered to reveal a survival benefit for ablated patients as compared to controls. Whereas thorough consideration of an early approach is necessary following two recent RCTs (PAUSE-SCD, BERLIN VT), catheter ablation is particularly recommended in patients with recurrent VT after ICD therapy. In this context, novel, pathophysiologically driven ablation strategies referring to deep morphological and functional substrate phenotyping based on high-resolution mapping and three-dimensional visualization of scars appear promising. Emerging concepts like sympathetic cardiac denervation as well as radioablation might expand the therapeutical armamentarium especially in patients with therapy-refractory VT. Randomized controlled trials are warranted and on the way to investigate how these translate into improved patient outcome. This review summarizes therapeutic strategies currently available for the prevention of VT recurrences, the optimal timing of applicability, and highlights future perspectives after a PAUSE in BERLIN.


Assuntos
Cardiomiopatias , Ablação por Cateter , Desfibriladores Implantáveis , Taquicardia Ventricular , Arritmias Cardíacas/terapia , Cardiomiopatias/cirurgia , Cardiomiopatias/terapia , Ablação por Cateter/efeitos adversos , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis/efeitos adversos , Cardioversão Elétrica/efeitos adversos , Humanos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/prevenção & controle , Resultado do Tratamento
17.
Pacing Clin Electrophysiol ; 45(12): 1383-1384, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-35821363

RESUMO

An 89-year-old woman underwent left atrial appendage (LAA) closure (LAAC) in our hospital because of recurrent gastrointestinal bleedings. The first transesophageal echocardiography (TEE) follow-up at six weeks revealed a complete sealing of the LAA and no device related thrombus. In a TEE follow-up at one year after the LAA closure, a large device related thrombus (6 × 3 cm) was found. Treated with oral anticoagulation (apixaban) the thrombus showed a partial resolution one year later.


Assuntos
Apêndice Atrial , Trombose , Idoso de 80 Anos ou mais , Humanos , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia
18.
Nano Lett ; 21(12): 5285-5292, 2021 Jun 23.
Artigo em Inglês | MEDLINE | ID: mdl-34076444

RESUMO

Lithium-sulfur batteries have ultrahigh theoretical energy densities, which makes them one of the most promising next-generation energy storage systems. However, it is still difficult to achieve large-scale commercialization because of the severe lithium polysulfide (LiPS) shuttle effect and low sulfur loading. Here, we report a flexible lithium-sulfur battery of a high sulfur loading with the assistance of NiCo2O4 nanofiber array grown carbon cloth. The NiCo2O4 nanofibers are ideal electrocatalysts for accelerating LiPS conversion kinetics through strong chemical interactions. Therefore, the composite cathode delivers a high specific capacity of 1280 mAh g-1 at 0.2 C with a sulfur loading of 3.5 mg cm-2, and it can maintain a high specific capacity of 660 mAh g-1 after 200 cycles, showing a good cycle stability. The "layer-by-layer" stacking strategy enables the Li-S battery with a high S loading of ∼9.0 mg cm-2 to deliver a high areal capacity of 8.9 mAh cm-2.

19.
Nano Lett ; 21(19): 8370-8377, 2021 Oct 13.
Artigo em Inglês | MEDLINE | ID: mdl-34543029

RESUMO

Lithium-rich layered oxides have received great attention due to their high energy density as cathode material. However, the progressive structural transformation from layered to spinel phase triggered by transition-metal migration and the irreversible release of lattice oxygen leads to voltage fade and capacity decay. Here, we report a Fe, Cl codoped and Co-free Li-rich layered cathode with significantly improved structural stability. It is revealed that the Fe and Cl codoping can facilitate the Li-ion diffusion and improve the rate performance of the materials. Moreover, the calculations show that the structural stability is enhanced by Fe and Cl codoping. As a result, the Fe and Cl codopant reduces the irreversible release of lattice oxygen, mitigates voltage fade, and improves the first-cycle Coulombic efficiency. This work provides a low-cost, environmentally friendly, practical strategy for high-performance cathode materials.

20.
J Cardiovasc Electrophysiol ; 32(3): 616-624, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33484215

RESUMO

BACKGROUND: Radiofrequency (RF) high-power ablation appears to be a novel concept in treating atrial fibrillation (AF). The ablation-index (AI) has been linked with the durability of pulmonary vein isolation (PVI). To report the midterm clinical results of a new ablation strategy using AI-guided high-power (50 W) ablation (AI-HP). METHODS AND RESULTS: Symptomatic AF patients were included and underwent wide-area circumferential PVI. Contact-force catheters were used, RF power was set to 50 W targeting AI values (550/400 for anterior/posterior) and interlesion distance 6 mm. Luminal esophageal temperature (LET) was monitored during the procedure; patients with LET ≥39°C underwent post-ablation esophageal-endoscopy. Seventy-two-hour-Holter ECGs were scheduled during follow-up. Procedural PVI was achieved in all (N = 122; mean age, 68.2 years; male, 71.3%) patients, rate of first-pass PVI was 96.7% per patient. Procedural mean RF time was 11.5 min, and mean RF time during posterior wall segment was 3.1 min. Per RF-lesion, the mean contact force, RF duration, AI, and impedance-drop at anterior/posterior wall were 26 ± 14 g/23 ± 12 g, 16.2 ± 7.5 s/8.8 ± 3.6 s, 552 ± 53/438 ± 47, and 13 ± 6 Ω/9 ± 5 Ω, respectively. Mean PVI procedural-time, 55.8 min; mean procedural fluoroscopic time, 5.6 min. Three (2.5%) patients had asymptomatic endoscopic small erosion/erythema esophageal lesions, no serious adverse events were observed. During a 15-month follow-up, overall single-procedure freedom from clinical recurrence of AF/atrial tachycardia (AT) off antiarrhythmic drug after blanking period was 85.2% (89.4% for paroxysmal AF, 80.4% for persistent AF). CONCLUSION: The AI-HP (50 W) appears as an efficient ablation technique in treating AF and leads to a high single-procedure arrhythmia-free survival at 15 months.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Idoso , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Seguimentos , Humanos , Masculino , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Recidiva , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA