Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 111
Filtrar
1.
Circ J ; 88(4): 559-567, 2024 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-37019644

RESUMO

BACKGROUND: Studies of the influence of smaller body type on the severity of prosthesis-patient mismatch (PPM) after small-sized surgical aortic valve replacement (SAVR) are few, but the issue is particularly relevant for Asian patients.Methods and Results: 695 patients who underwent SAVR with bioprosthetic valves had their hemodynamic valve performance analyzed at 3 months, 1 year, 3 years, and 5 years after operation, and clinical outcomes were assessed. The patients were stratified into 3 valve size groups: 19/21, 23, and 25/27 mm. A smaller valve was associated with higher mean pressure gradients at the 4 time points after operation (P trend <0.05). However, the 3 valve size groups demonstrated no significant differences in the risk of clinical events. At none of the time points did patients with projected PPM show increased mean pressure gradients (P>0.05), whereas patients with measured PPM did (P<0.05). Compared with patients with projected PPM, those with measured PPM demonstrated higher rates of infective endocarditis readmission (adjusted hazard ratio [aHR] 3.31, 95% confidence interval [CI] 1.06-10.39) and a higher risk of composite outcomes (aHR 1.45, 95% CI 0.95-2.22, P=0.087). CONCLUSIONS: Relative to those receiving larger valves, patients receiving small bioprosthetic valves had poorer hemodynamic performance but did not demonstrate differences in clinical events in long-term follow-up.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Seguimentos , Estenose da Valva Aórtica/etiologia , Resultado do Tratamento , Próteses Valvulares Cardíacas/efeitos adversos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Desenho de Prótese , Hemodinâmica
2.
Circ J ; 88(4): 579-588, 2024 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-38267036

RESUMO

BACKGROUND: Mitral valve (MV) disease is the most common form of valvular heart disease. Findings that indicate women have a higher risk for unfavorable outcomes than men remain controversial. This study aimed to determine the sex-based differences in epidemiological distributions and outcomes of surgery for MV disease.Methods and Results: Overall, 18,572 patients (45.3% women) who underwent MV surgery between 2001 and 2018 were included. Outcomes included in-hospital death and all-cause mortality during follow up. Subgroup analysis was conducted across different etiologies, including infective endocarditis (IE), degenerative, ischemic, and rheumatic mitral pathology. The overall MV repair rate was lower in women than in men (20.5% vs. 30.6%). After matching, 6,362 pairs (woman : man=1 : 1) of patients were analyzed. Women had a slightly higher risk for in-hospital death than men (10.8% vs. 9.8%; odds ratio [OR]: 1.11, 95% confidence interval [CI]: 0.99-1.24; P=0.075). Women tended to have a higher incidence of de novo dialysis (9.8% vs. 8.6%; P=0.022) and longer intensive care unit stay (8 days vs. 7.1 days; P<0.001). Women with IE had poorer in-hospital outcomes than men; however, there were no sex differences in terms of all-cause mortality. CONCLUSIONS: Sex-based differences of MV intervention still persist. Although long-term outcomes were comparable between sexes, women, especially those with IE, had worse perioperative outcomes than men.


Assuntos
Endocardite Bacteriana , Endocardite , Doenças das Valvas Cardíacas , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Humanos , Feminino , Masculino , Valva Mitral/cirurgia , Mortalidade Hospitalar , Caracteres Sexuais , Implante de Prótese de Valva Cardíaca/efeitos adversos , Resultado do Tratamento , Diálise Renal , Doenças das Valvas Cardíacas/epidemiologia , Doenças das Valvas Cardíacas/cirurgia , Endocardite Bacteriana/cirurgia , Insuficiência da Valva Mitral/epidemiologia , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Mitral/etiologia , Estudos Retrospectivos
3.
Circ J ; 88(3): 309-318, 2024 Feb 22.
Artigo em Inglês | MEDLINE | ID: mdl-37648519

RESUMO

BACKGROUND: In Taiwan, infective native aortic aneurysms (INAAs) are relatively common, so the aim of present study was to demonstrate the comparative outcomes of endovascular repair for thoracic and abdominal INAAs.Methods and Results: Patients with naïve thoracic or abdominal INAAs managed with endovascular repair between 2001 and 2018 were included in this multicenter retrospective cohort. The confounding factors were adjusted with propensity score (PS). Of the 39 thoracic and 43 abdominal INAA cases, 41 (50%) presented with aneurysmal rupture, most of which were at the infrarenal abdominal (n=35, 42.7%) or descending thoracic aorta (n=25, 30.5%). Salmonella spp. was the most frequently isolated pathogen. The overall in-hospital mortality rate was 18.3%. The risks of in-hospital death and death due to rupture were significantly lower with thoracic INAAs (12.8% vs. 23.3%; PS-adjusted odds ratio (OR) 0.24, 95% confidence interval (CI) 0.06-0.96; 0.1% vs. 9.3%; PS-adjusted OR 0.11, 95% CI 0.01-0.90). During a mean follow-up of 2.5 years, the risk of all-cause death was significantly higher with thoracic INAAs (35.3% vs. 15.2%; PS-adjusted HR 6.90, 95% CI 1.69-28.19). Chronic kidney disease (CKD) was associated with death. CONCLUSIONS: Compared with thoracic INAAs, endovascular repair of abdominal INAAs was associated with a significantly higher in-hospital mortality rate. However, long-term outcomes were worse for thoracic INAAs, with CKD and infections being the most important predictor and cause of death, respectively.


Assuntos
Aneurisma Infectado , Aneurisma da Aorta Abdominal , Aneurisma da Aorta Torácica , Aneurisma Aórtico , Implante de Prótese Vascular , Procedimentos Endovasculares , Insuficiência Renal Crônica , Humanos , Estudos Retrospectivos , Mortalidade Hospitalar , Implante de Prótese Vascular/efeitos adversos , Resultado do Tratamento , Aneurisma Aórtico/complicações , Aneurisma da Aorta Torácica/cirurgia , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/complicações , Aneurisma Infectado/cirurgia , Aneurisma Infectado/complicações , Insuficiência Renal Crônica/complicações , Procedimentos Endovasculares/métodos , Fatores de Risco , Complicações Pós-Operatórias
4.
J Cardiothorac Vasc Anesth ; 38(5): 1161-1168, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38467525

RESUMO

OBJECTIVES: To estimate the association between early surgery and the risk of mortality in patients with left-sided infective endocarditis in the context of stroke. DESIGN: Retrospective cohort study. SETTING: This study was a multiinstitution study based on the Chang Gung Research Database, which contains electronic medical records from 7 hospitals in northern and southern Taiwan; these include 2 medical centers, 2 regional hospitals, and 3 district hospitals. PARTICIPANTS: Patients with active left-sided infective endocarditis who underwent valve surgery between September 2002 and December 2018. INTERVENTIONS: The authors divided patients into 2 groups, with versus without preoperative neurologic complications, had undergone early (within 7 d) or later surgery, and with brain ischemia or hemorrhage. MEASUREMENTS AND MAIN RESULTS: Three hundred ninety-two patients with a median time from diagnosis to surgery of 6 days were included. No significant differences in postoperative stroke, in-hospital mortality, or follow-up outcomes were observed between the patients with and without neurologic complications. Among the patients with preoperative neurologic complications, patients who underwent early surgery had a lower 30-day postoperative mortality rate (13.1% v 25.8%; hazard ratio, 0.21; 95% CI 0.07-0.67). In the subgroup analysis of the comparison between brain ischemia and hemorrhage groups, there was no significant between-group difference in the in-hospital outcomes or outcomes after discharge. CONCLUSIONS: Early cardiac surgery may be associated with more favorable clinical outcomes in patients with preoperative neurologic complications. Thus, preoperative neurologic complications should not delay surgical interventions.


Assuntos
Isquemia Encefálica , Endocardite Bacteriana , Endocardite , Doenças do Sistema Nervoso , Acidente Vascular Cerebral , Humanos , Estudos Retrospectivos , Endocardite Bacteriana/complicações , Endocardite Bacteriana/cirurgia , Endocardite/complicações , Endocardite/cirurgia , Acidente Vascular Cerebral/cirurgia , Acidente Vascular Cerebral/complicações , Isquemia Encefálica/complicações , Isquemia Encefálica/cirurgia , Doenças do Sistema Nervoso/epidemiologia , Doenças do Sistema Nervoso/etiologia , Hemorragia , Resultado do Tratamento
5.
Circ J ; 87(9): 1164-1172, 2023 08 25.
Artigo em Inglês | MEDLINE | ID: mdl-36823078

RESUMO

BACKGROUND: Fluoroquinolone use can be associated with an increased risk of aortic aneurysm (AA) or aortic dissection (AD). The US Food and Drug Administration recently warned against fluoroquinolone use for high-risk patients, such as those with Marfan syndrome. However, the association between fluoroquinolone use and AA/AD risk was unknown in these high-risk patients and therefore it was studied in this work.Methods and Results: Data were collected from a national database between 2000 and 2017 for 550 patients with AA/AD and any congenital aortic disease (mean age 41.5 years; 415 with Marfan syndrome). A case cross-over study was conducted to compare the risk of aortic events (AA/AD) associated with fluoroquinolone and amoxicillin use between the hazard period (from -60 days to -1 day) and a randomly selected reference period (-180 to -121 days; -240 to -181 days; and -300 to -241 days). Compared to the reference period without fluoroquinolone use, fluoroquinolone use during the hazard period was not associated with a greater risk of AA/AD (1.09% vs. 1.09%; odds ratio [OR] 1.000; 95% confidence interval [CI] 0.32-3.10), AA (OR 0.67; 95% CI 0.11-3.99), or AD (OR 1.33; 95% CI 0.30-5.96) in patients with congenital aortic disease or Marfan syndrome. This lack of association was maintained in subgroup analysis, including Marfan syndrome or not, age (≤50 vs. >50 years) and sex. CONCLUSIONS: Fluoroquinolone use was not associated with an increased risk of AA/AD in patients with congenital aortic disease, including Marfan syndrome. More evidence is required for a fluoroquinolone pharmacovigilance plan in these patients.


Assuntos
Aneurisma Aórtico , Dissecção Aórtica , Síndrome de Marfan , Adulto , Humanos , Aneurisma Aórtico/induzido quimicamente , Aneurisma Aórtico/epidemiologia , Dissecção Aórtica/induzido quimicamente , Dissecção Aórtica/epidemiologia , Estudos Cross-Over , Fluoroquinolonas/efeitos adversos , Síndrome de Marfan/complicações
6.
Circ J ; 87(5): 600-607, 2023 04 25.
Artigo em Inglês | MEDLINE | ID: mdl-36223943

RESUMO

BACKGROUND: In modern critical care, extracorporeal membrane oxygenation (ECMO) is crucial in the management of severe respiratory and cardiac failure. Nationwide studies of the relationship between hospital volume and outcomes of ECMO use are unavailable.Methods and Results: Using Taiwan's National Health Insurance Research Database, we identified 11,734 adult patients who received ECMO support in 101 hospitals between January 1, 2001, and December 31, 2017. Outcomes included in-hospital mortality, 1-year mortality, and ECMO-related complications. Cox proportional hazards model, locally estimated scatterplot smoothing, and restricted cubic spline regression were used to analyze the volume-outcome relationship. The overall in-hospital mortality rate was 65.5%, and the 1-year mortality rate was 70.6% in this database. The 101 hospitals were divided into 4 groups based on annual volume. The in-hospital and 1-year mortality rates were significantly lower in the high-volume group (annual volume >40) than in the low-volume group (annual volume <10). CONCLUSIONS: For critical care, high-volume hospitals have superior short-term and mid-term outcomes. To make the medical system equitable and reasonable, establishing a rapid and efficient nationwide referral system should be considered.


Assuntos
Oxigenação por Membrana Extracorpórea , Adulto , Humanos , Estudos de Coortes , Taiwan/epidemiologia , Hospitais com Alto Volume de Atendimentos , Mortalidade Hospitalar , Estudos Retrospectivos , Resultado do Tratamento
7.
BMC Cardiovasc Disord ; 23(1): 84, 2023 02 11.
Artigo em Inglês | MEDLINE | ID: mdl-36774460

RESUMO

BACKGROUND: Atrial fibrillation is the most common cardiac arrythmia and causes many complications. Sinus rhythm restoration could reduce late mortality of atrial fibrillation patients. The Maze procedure is the gold standard for surgical ablation of atrial fibrillation. Higher surgical volume has been documented with favorable outcomes of various cardiac procedures such as mitral valve surgery and aortic valve replacement. We aimed to determine the volume-outcome relationship (i.e., association between surgical volume and outcomes) for the concomitant Maze procedure during major cardiac surgeries. METHODS: This nationwide population-based cohort study retrieved data from the Taiwan National Health Insurance Research Database. Adult patients undergoing concomitant Maze procedures during 2010-2017 were identified; consequently, 2666 patients were classified into four subgroups based on hospital cumulative surgery volumes. In-hospital outcomes and late outcomes during follow-up were analyzed. Logistic regression and Cox proportional hazards model were used to analyze the volume-outcome relationship. RESULTS: Patients undergoing Maze procedures at lower-volume hospitals tended to be frailer and had higher comorbidity scores. Patients in the highest-volume hospitals had a lower risk of in-hospital mortality than those in the lowest-volume hospitals [adjusted odds ratio, 0.30; 95% confidence interval (CI), 0.15-0.61; P < 0.001]. Patients in the highest-volume hospitals had lower rates of late mortality than those in the lowest-volume hospitals, including all-cause mortality [adjusted hazard ratio (aHR) 0.53; 95% CI 0.40-0.68; P < 0.001] and all-cause mortality after discharge (aHR 0.60; 95% CI 0.44-0.80; P < 0.001). CONCLUSIONS: A positive hospital volume-outcome relationship for concomitant Maze procedures was demonstrated for in-hospital and late follow-up mortality. The consequence may be attributed to physician skill/experience, experienced multidisciplinary teams, and comprehensive care processes. We suggest referring patients with frailty or those requiring complicated cardiac surgeries to high-volume hospitals to improve clinical outcomes. TRIAL REGISTRATION: the institutional review board of Chang Gung Memorial Hospital approved all data usage and the study protocol (registration number: 202100151B0C502).


Assuntos
Fibrilação Atrial , Procedimentos Cirúrgicos Cardíacos , Ablação por Cateter , Adulto , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/complicações , Estudos de Coortes , Resultado do Tratamento , Modelos de Riscos Proporcionais , Ablação por Cateter/métodos
8.
Nano Lett ; 22(20): 8137-8142, 2022 Oct 26.
Artigo em Inglês | MEDLINE | ID: mdl-36200986

RESUMO

Loading quantum information deterministically onto a quantum node is an important step toward a quantum network. Here, we demonstrate that coherent-state microwave photons with an optimal temporal waveform can be efficiently loaded onto a single superconducting artificial atom in a semi-infinite one-dimensional (1D) transmission-line waveguide. Using a weak coherent state (the number of photons (N) contained in the pulse ≪1) with an exponentially rising waveform, whose time constant matches the decoherence time of the artificial atom, we demonstrate a loading efficiency of 94.2% ± 0.7% from 1D semifree space to the artificial atom. The high loading efficiency is due to time-reversal symmetry: the overlap between the incoming wave and the time-reversed emitted wave is up to 97.1% ± 0.4%. Our results open up promising applications in realizing quantum networks based on waveguide quantum electrodynamics.

9.
J Environ Manage ; 330: 117114, 2023 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-36586368

RESUMO

Forest carbon stocks and sinks (CSSs) have been widely estimated using climate classification tables and linear regression (LR) models with common independent variables (IVs) such as the average diameter at breast height (DBH) of stems and root shoot ratio. However, this approach is relatively ineffective when the explanatory power of IVs is lower than that of unobservable variables. Various environmental and anthropogenic factors affect target variables that cause the correlation between them to be chaotic. Here, we designed a knife set (KS) approach combining LR models and the wandering through random forests (WTF) algorithm and applied it in a specific case of Phyllostachys edulis (Carrière) J. Houz. (P. edulis) forests, which have an irregular relationship between their belowground carbon (BGC) stocks and average DBH. We then validated the KS approach performed by cluster computing to estimate the aboveground carbon (AGC) and BGC stocks and the total net primary production (TNPP). The estimated CSSs were compared to the benchmark of the methodology that applied Tier 1 in the Intergovernmental Panel on Climate Change (IPCC) Guidelines for National Greenhouse Gas Inventories via 10-fold cross validation, and the KS approach significantly increased precision and accuracy of estimations. Our approach provides general insights to accurately estimate forest CSSs relying on evidence-based field data, even if some target variables are divergent in specific forest types. We also pointed out the reason why current fancy models containing machine learning (ML) or deep learning algorithms are not effective in predicting the target variables of certain chaotic systems is perhaps that the total explanatory power of observable variables is less than that of the total unobservable variables. Quantifying unobservable variables into observable variables is a linchpin of future works related to chaotic system estimation.


Assuntos
Sequestro de Carbono , Carbono , Mudança Climática
10.
Analyst ; 146(23): 7345-7357, 2021 Nov 22.
Artigo em Inglês | MEDLINE | ID: mdl-34766961

RESUMO

Despite the importance of carbohydrates in biological systems, structural determination of carbohydrates remains difficult because of the large number of isomers. In this study, a new mass spectrometry method, namely logically derived sequence tandem mass spectrometry (LODES/MSn), was developed to characterize oligosaccharide structures. In this approach, sequential collision-induced dissociation (CID) of oligosaccharides is performed in an ion trap mass spectrometer to identify the linkage position, anomeric configuration, and stereoisomers of each monosaccharide in the oligosaccharides. The CID sequences are derived from carbohydrate dissociation mechanisms. LODES/MSn does not require oligosaccharide standards or the prior knowledge of the rules and principles of biosynthetic pathways; thus LODES/MSn is particularly useful for the investigation of undiscovered oligosaccharides. We demonstrated that the structure of core oligosaccharides in glycosphingolipids can be identified from more than 500 000 isomers using LODES/MSn. The same method can be applied for determining the structures of other oligosaccharides, such as N-, and O-glycans, and free oligosaccharides in milk.


Assuntos
Glicoesfingolipídeos , Espectrometria de Massas em Tandem , Isomerismo , Oligossacarídeos , Polissacarídeos
11.
Angew Chem Int Ed Engl ; 60(22): 12413-12423, 2021 05 25.
Artigo em Inglês | MEDLINE | ID: mdl-33634934

RESUMO

The stereoselectivity and yield in glycosylation reactions are paramount but unpredictable. We have developed a database of acceptor nucleophilic constants (Aka) to quantify the nucleophilicity of hydroxyl groups in glycosylation influenced by the steric, electronic and structural effects, providing a connection between experiments and computer algorithms. The subtle reactivity differences among the hydroxyl groups on various carbohydrate molecules can be defined by Aka, which is easily accessible by a simple and convenient automation system to assure high reproducibility and accuracy. A diverse range of glycosylation donors and acceptors with well-defined reactivity and promoters were organized and processed by the designed software program "GlycoComputer" for prediction of glycosylation reactions without involving sophisticated computational processing. The importance of Aka was further verified by random forest algorithm, and the applicability was tested by the synthesis of a Lewis A skeleton to show that the stereoselectivity and yield can be accurately estimated.

12.
Nat Methods ; 14(4): 388-390, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28218900

RESUMO

High-resolution optical imaging is critical to understanding brain function. We demonstrate that three-photon microscopy at 1,300-nm excitation enables functional imaging of GCaMP6s-labeled neurons beyond the depth limit of two-photon microscopy. We record spontaneous activity from up to 150 neurons in the hippocampal stratum pyramidale at ∼1-mm depth within an intact mouse brain. Our method creates opportunities for noninvasive recording of neuronal activity with high spatial and temporal resolution deep within scattering brain tissues.


Assuntos
Encéfalo/citologia , Microscopia de Fluorescência por Excitação Multifotônica/métodos , Neurônios/fisiologia , Animais , Encéfalo/fisiologia , Calmodulina/análise , Calmodulina/metabolismo , Proteínas de Fluorescência Verde/análise , Proteínas de Fluorescência Verde/genética , Proteínas de Fluorescência Verde/metabolismo , Hipocampo/citologia , Hipocampo/fisiologia , Masculino , Camundongos Endogâmicos C57BL , Camundongos Transgênicos , Proteínas Recombinantes de Fusão/análise , Proteínas Recombinantes de Fusão/metabolismo , Proteínas Recombinantes/análise , Proteínas Recombinantes/genética , Proteínas Recombinantes/metabolismo
13.
Org Biomol Chem ; 18(2): 305-315, 2020 01 02.
Artigo em Inglês | MEDLINE | ID: mdl-31845709

RESUMO

This study describes an efficient protocol for the preparation of substituted 2,4-diaryl-3-sulfonylquinolines from functionalized 2-aminobenzophenones and aromatic ß-ketosulfones by using p-toluenesulfonic acid monohydrate under microwave irradiation. In this atom-economical synthetic route, a series of pharmaceutically active 3-arylsulfonylquinolines with good functional group tolerance are prepared in good to excellent yields. Some structures are confirmed by single-crystal X-ray diffraction analysis.

14.
Environ Res ; 170: 282-292, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30599292

RESUMO

BACKGROUND: A critical adaptation strategy for reducing heat-related health risk under climate change is to establish a heat warning system with a proper threshold that requires evaluation of heat-health relationships using empirical data. OBJECTIVES: This work presents a new approach to selecting proper health-based thresholds for a heat warning system which are different from thresholds of heat-health relationship. METHODS: The proposed approach examined heat-health relationships through analyzing 15 years of health records with a modified generalized additive model (GAM), compared risk ratio increments (RRIs) of threshold candidates against a reference, assessed frequency of days above these candidates, and presented results graphically for easy communication. The candidate with the maximum RRI and proper occurring frequency is potentially the best threshold. Three heat indicators, including wet-bulb globe temperature (WBGT), temperature (T), and apparent temperature (AT), as well as three health outcomes, including all-cause mortality, heat-related hospital admissions, and heat-related emergency visits were evaluated. RESULTS: Risk ratios for all three health outcomes showed a consistent rising trend with increasing threshold candidates for all three heat indicators among different age and gender groups. WBGT had the most obvious increasing trend of RRIs with the three health outcomes. The maximum RRI was observed in heat-related emergency visits (242%), followed by heat-related hospital admissions (73%), and all-cause mortality (9%). The RRIs assessed for the three health outcomes pointed to the same thresholds, 33.0 °C, 34.0 °C, and 37.5 °C for WBGT, T, and AT, respectively. The number of days above these thresholds and for warning to be issued ranged between 0 and 7 days during 2000-2014. DISCUSSION: This study demonstrated a new approach to determining heat-warning thresholds with different heat indicators and health outcomes. The proposed approach provides a straightforward, feasible, and flexible scientific tool that assists the authorities around the world in selecting a proper threshold for a heat warning system.


Assuntos
Transtornos de Estresse por Calor , Temperatura Alta , Mudança Climática , Saúde , Humanos , Risco , Temperatura
15.
Pharmacol Res ; 114: 128-143, 2016 12.
Artigo em Inglês | MEDLINE | ID: mdl-27794498

RESUMO

In spite of the current advances and achievements in systems biology and translational medicinal research, the current strategies for cancer therapy, such as radiotherapy, targeted therapy, immunotherapy and chemotherapy remain palliative or unsatisfactory due to tumor metastasis or recurrence after surgery/therapy, drug resistance, adverse side effects, and so on. Oxidative stress (OS) plays a critical role in chronic/acute inflammation, carcinogenesis, tumor progression, and tumor invasion/metastasis which is also attributed to the dynamic and complex properties and activities in the tumor microenvironment (TME). Re-educating or reprogramming tumor-associated stromal or immune cells in the TME provides an approach for restoring immune surveillance impaired by disease in cancer patients to increase overall survival and reduce drug resistance. Herbal medicines or plant-derived natural products have historically been a major source of anti-cancer drugs. Delving into the lore of herbal medicine may uncover new leads for anti-cancer drugs. Phytomedicines have been widely documented to directly or indirectly target multiple signaling pathways and networks in cancer cells. A combination of anti-cancer drugs and polypharmacological plant-derived extracts or compounds may offer a significant advantage in sensitizing the efficacy of monotherapy and overcoming drug-induced resistance in cancer patients. This review introduces several phytochemicals and phytoextracts derived from medicinal plants or dietary vegetables that have been studied for their efficacy in preclinical cancer models. We address the underlying modes of action of induction of OS and deregulation of TME-associated stromal cells, mediators and signaling pathways, and reference the related clinical investigations that look at the single or combination use of phytochemicals and phytoextracts to sensitize anti-cancer drug effects and/or overcome drug resistance.


Assuntos
Antineoplásicos Fitogênicos/uso terapêutico , Neoplasias/tratamento farmacológico , Estresse Oxidativo/efeitos dos fármacos , Microambiente Tumoral/efeitos dos fármacos , Animais , Antineoplásicos Fitogênicos/farmacologia , Humanos , Inflamação/tratamento farmacológico , Inflamação/imunologia , Inflamação/metabolismo , Inflamação/patologia , Neoplasias/imunologia , Neoplasias/metabolismo , Neoplasias/patologia , Transdução de Sinais/efeitos dos fármacos
16.
Infect Immun ; 83(7): 2836-43, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25916992

RESUMO

To reduce the need for antibiotics in animal production, alternative approaches are needed to control infection. We hypothesized that overexpression of native defensin genes will provide food animals with enhanced resistance to bacterial infections. In this study, recombinant porcine beta-defensin 2 (PBD-2) was overexpressed in stably transfected PK-15 porcine kidney cells. PBD-2 antibacterial activities against Actinobacillus pleuropneumoniae, an important respiratory pathogen causing porcine contagious pleuropneumonia, were evaluated on agar plates. Transgenic pigs constitutively overexpressing PBD-2 were produced by a somatic cell cloning method, and their resistance to bacterial infection was evaluated by direct or cohabitation infection with A. pleuropneumoniae. Recombinant PBD-2 peptide that was overexpressed in the PK-15 cells showed antibacterial activity against A. pleuropneumoniae. PBD-2 was overexpressed in the heart, liver, spleen, lungs, kidneys, and jejunum of the transgenic pigs, which showed significantly lower bacterial loads in the lungs and reduced lung lesions after direct or cohabitation infection with A. pleuropneumoniae. The results demonstrate that transgenic overexpression of PBD-2 in pigs confers enhanced resistance against A. pleuropneumoniae infection.


Assuntos
Infecções por Actinobacillus/prevenção & controle , Actinobacillus pleuropneumoniae/imunologia , Resistência à Doença , Expressão Gênica , Doenças dos Suínos/prevenção & controle , beta-Defensinas/biossíntese , Infecções por Actinobacillus/imunologia , Animais , Animais Geneticamente Modificados , Carga Bacteriana , Linhagem Celular , Pulmão/microbiologia , Masculino , Suínos , Doenças dos Suínos/imunologia
17.
Percept Mot Skills ; 120(1): 304-22, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25650508

RESUMO

This study assessed the concurrent and construct validity of the Borg 6-20 Scale and WHEEL Scale during arm ergometry exercise stress testing in (n = 24) adolescents and adults with spina bifida. Significant, moderate, positive correlations were observed between power output and relative heart rate and power output to relative VO2peak. Further, a moderate, significant correlation between physiologic criterion variables and the rating of perceived exertion derived from the Borg Scale and the WHEEL Scale was found. Concurrent validity was supported by the following findings: (1) relative heart rate was significantly correlated with the Borg (Kendall's τ = .41) and WHEEL Scales (τ = .44), and relative VO2 was significantly correlated with the Borg (τ = .46) and WHEEL Scales (τ = .47); (2) content validity was supported by the finding that the Borg and WHEEL Scales shared significant variance (τ = .70), demonstrating internal consistency. The WHEEL Scale shows strong potential for use in this cohort subsequent to further testing and validation.


Assuntos
Ergometria/métodos , Teste de Esforço/métodos , Esforço Físico/fisiologia , Psicometria/instrumentação , Disrafismo Espinal/reabilitação , Cadeiras de Rodas/normas , Adolescente , Adulto , Idoso , Braço , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Adulto Jovem
18.
Talanta ; 275: 126107, 2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-38696901

RESUMO

In this letter, we propose a miniaturization scheme of inkjet printed ionic sensing electrodes by adding graphene into the ion-selective PVC film not only to reduce the impedance of the ionic liquid layer of the electrode but also to increase the electrode capacitance for the reduction of the response time. Based on the scheme, we present a fully inkjet-printed electrochemical ion-selective sensor comprising a working electrode and reference electrode, which are inkjet-printed Ag NPs/PEDOT:PSS-graphene/PVC-graphene and Ag/AgCl(s)/ionic liquid PVC-graphene layer structures, respectively. The printed ion-selective working electrode has been miniaturized to a size of 22,400 µm2 equivalent to a square shape of ∼150 × 150 µm2 comparable to the size of a human cell. By adding graphene to the ion selective PVC film, more than 90 % charge transfer resistance reduction can be achieved and the shunt capacitance is increased by 3.4-fold in shunt capacitance compared to the film without graphene, thereby more than 33 % reduction of the response time required to reach equilibrium. Meanwhile, these miniaturized potassium sensors using the working electrodes with/without adding graphene have been integrated with in-lab signal-processing and wireless-transmission module to yield similar results to the one measured by commercial electrochemical workstation showing a great potential for real-time monitoring in portable clinical trials. Specifically, the proposed sensor utilizing graphene-enhanced electrodes demonstrates a linearity uncertainty of 2.9 mV, which is approximately half of the uncertainty observed in the sensors lacking graphene integration.

19.
bioRxiv ; 2024 Apr 06.
Artigo em Inglês | MEDLINE | ID: mdl-38617307

RESUMO

Nonlinear optical microscopy enables non-invasive imaging in scattering samples with cellular resolution. The spinal cord connects the brain with the periphery and governs fundamental behaviors such as locomotion and somatosensation. Because of dense myelination on the dorsal surface, imaging to the spinal grey matter is challenging, even with two-photon microscopy. Here we show that three-photon excited fluorescence (3PEF) microscopy enables multicolor imaging at depths of up to ~550 µm into the mouse spinal cord, in vivo. We quantified blood flow across vessel types along the spinal vascular network. We then followed the response of neurites and microglia after occlusion of a surface venule, where we observed depth-dependent structural changes in neurites and interactions of perivascular microglia with vessel branches upstream from the clot. This work establishes that 3PEF imaging enables studies of functional dynamics and cell type interactions in the top 550 µm of the murine spinal cord, in vivo.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA