1.
J Invasive Cardiol ; 35(3): E128-E135, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36645333

RESUMO

BACKGROUND: Severe coronary artery calcification (CAC) remains challenging during percutaneous coronary intervention (PCI) and often requires 1 or more advanced calcium modification tools. OBJECTIVES: We describe the combination use of rotational (RA) or orbital atherectomy (OA), with intravascular lithotripsy (IVL), termed rotatripsy and orbital-tripsy, respectively, for modifying CAC prior to stent implantation during PCI. METHODS: We performed a retrospective analysis of patients treated with rotatripsy or orbital-tripsy at our center between July 2019 and March 2022. The primary efficacy endpoint was procedural success (successful stent implantation, <30% residual stenosis visually, Thrombolysis in Myocardial Infarction 3 flow; absence of types C to F dissection/perforation or loss of side branch ≥2.0mm visually) without in-hospital major adverse cardiovascular event (MACE, defined as cardiovascular death, myocardial infarction [MI], target-vessel revascularization). RESULTS: A total of 25 patients (14 rotatripsy and 11 orbital-tripsy) were included in our study. The mean age was 72.2 ± 7.6 years and 76% were men. PCI was guided by intravascular imaging in 24 patients (96%). All cases were treated with either RA or OA before utilization of IVL. Procedural success was achieved in 22 cases (88%) with 1 sidebranch loss without periprocedural MI (4%) and 2 in-patient deaths (8%) unrelated to the procedure (1 intracerebral hemorrhage and 1 cardiac arrest). CONCLUSION: We describe efficacious use of both rotatripsy and orbital-tripsy to modify severe CAC during PCI in a real-world setting. Intravascular imaging can guide appropriate use of these devices to complement each other to modify severe CAC to achieve optimal outcomes.


Assuntos
Aterectomia Coronária , Doença da Artéria Coronariana , Litotripsia , Infarto do Miocárdio , Intervenção Coronária Percutânea , Calcificação Vascular , Masculino , Humanos , Pessoa de Meia-Idade , Idoso , Feminino , Intervenção Coronária Percutânea/métodos , Aterectomia Coronária/métodos , Cálcio , Estudos Retrospectivos , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/cirurgia , Resultado do Tratamento , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/cirurgia , Infarto do Miocárdio/etiologia , Aterectomia , Calcificação Vascular/diagnóstico , Calcificação Vascular/cirurgia , Angiografia Coronária/métodos
2.
J Clin Med ; 10(10)2021 May 17.
Artigo em Inglês | MEDLINE | ID: mdl-34067605

RESUMO

Left ventricular hypertrophy (LVH) caused by cardiac variant Fabry disease (FD) is typically late-onset and may mimic LVH caused by abnormal loading conditions. We aimed to determine the prevalence of FD in a non-selective patient population of everyday practice presenting with LVH, including those with hypertension and valve disease. We measured plasma alpha-galactosidase A activity using dried blood spot tests in 499 (age = 66 ± 13 years; 336 men) Hong Kong Chinese patients with LVH defined as maximal LV septal/posterior wall thickness ≥13 mm on echocardiography. Patients with low enzyme activity underwent mutation analysis of the GLA gene. Eight (age = 53-74 years; all men) unrelated patients (1.6%) had low plasma alpha-galactosidase A activity (0.57 ± 0.27 µmol/L wb/hr) and all were confirmed to have the GLA IVS4 + 919G > A mutation. FD patients presented with heart failure (n = 5), heart block (n = 2), ventricular tachycardia (n = 1), chest pain (n = 3), and/or murmur (n = 1). Uncontrolled hypertension (n = 4) and/or severe mitral/aortic valve pathology (n = 2) were frequent. Ethnic subgroups included Teochew (n = 5), Canton (n = 2), and Wenzhou (n = 1). Endomyocardial biopsy (n = 6) revealed hypertrophic myocytes with vacuolization and dense lamellar bodies. Late-onset IVS4 + 919G > A FD is prevalent among Chinese LVH patients, and should be considered as a cause of LVH in adult patients even when hypertension and/or valve pathology are present.

3.
J Invasive Cardiol ; 32(7): E190, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32610273

RESUMO

Venography alone may underestimate the extent of common iliac vein compression in May-Thurner syndrome. Peripheral intravascular ultrasound is mandatory to better assess common iliac vein compression.


Assuntos
Síndrome de May-Thurner , Rabdomiólise , Trombose Venosa , Humanos , Veia Ilíaca/diagnóstico por imagem , Síndrome de May-Thurner/complicações , Síndrome de May-Thurner/diagnóstico , Rabdomiólise/diagnóstico , Rabdomiólise/etiologia , Veia Cava Inferior , Trombose Venosa/etiologia
6.
Clin Med (Lond) ; 20(1): 107-109, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31941743

RESUMO

Ion-exchange resins, sodium or calcium polystyrene sulfonate, are commonly used medications for management of hyperkalaemia. However, the drug can be associated with serious bowel injury. We report a case of a renal transplant recipient who developed duodenal ulcer perforation secondary to the use of calcium polystyrene sulfonate. Characteristic eosinophilic non-polarisable rhomboid shaped crystals were evident in the affected area of ulceration on histologic examination in addition to features of cytomegalovirus inclusions. We also hypothesised that gastroparesis secondary to autonomic dysfunction could have led to prolonged luminal contact time with polystyrene, further predisposing to bowel injury.


Assuntos
Úlcera Duodenal , Hiperpotassemia , Úlcera Duodenal/induzido quimicamente , Humanos , Hiperpotassemia/induzido quimicamente , Poliestirenos/efeitos adversos , Sódio
7.
PLoS One ; 15(9): e0239675, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32987398

RESUMO

Fabry Disease (FD) is a systemic disorder that can result in cardiovascular, renal, and neurovascular disease leading to reduced life expectancy. FD should be considered in the differential of all patients with unexplained left ventricular hypertrophy (LVH). We therefore performed a prospective screening study in Edmonton and Hong Kong using Dried Blood Spot (DBS) testing on patients with undiagnosed LVH. Participants found to have unexplained LVH on echocardiography were invited to participate and subsequently subjected to DBS testing. DBS testing was used to measure α-galactosidase (α-GAL) enzyme activity and for mutation analysis of the α-galactosidase (GLA) gene, both of which are required to make a diagnosis of FD. DBS testing was performed as a screening tool on patients (n = 266) in Edmonton and Hong Kong, allowing for detection of five patients with FD (2% prevalence of FD) and one patient with hydroxychloroquine-induced phenocopy. Left ventricular mass index (LVMI) by GLA genotype showed a higher LVMI in patients with IVS4 + 919G > A mutations compared to those without the mutation. Two patients were initiated on ERT and hydroxychloroquine was discontinued in the patient with a phenocopy of FD. Overall, we detected FD in 2% of our screening cohort using DBS testing as an effective and easy to administer screening tool in patients with unexplained LVH. Utilizing DBS testing to screen for FD in patients with otherwise undiagnosed LVH is clinically important due to the availability of effective therapies and the value of cascade screening in extended families.


Assuntos
Doença de Fabry/diagnóstico , Doença de Fabry/enzimologia , Hipertrofia Ventricular Esquerda/diagnóstico , Hipertrofia Ventricular Esquerda/enzimologia , Programas de Rastreamento/métodos , alfa-Galactosidase/genética , Adulto , Idoso , Idoso de 80 Anos ou mais , Análise Mutacional de DNA , Diagnóstico Diferencial , Teste em Amostras de Sangue Seco , Ecocardiografia , Doença de Fabry/epidemiologia , Feminino , Genótipo , Hong Kong/epidemiologia , Humanos , Hipertrofia Ventricular Esquerda/epidemiologia , Masculino , Pessoa de Meia-Idade , Mutação , Fenótipo , Estudos Prospectivos
10.
J Invasive Cardiol ; 30(7): E57-E58, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29958179
11.
JACC Clin Electrophysiol ; 4(9): 1214-1223, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-30236396

RESUMO

OBJECTIVES: This study aimed to examine the relationship between chronic coronary artery total occlusion (CTO) status and the occurrence of ventricular tachycardia (VT)/ventricular fibrillation (VF) or appropriate implantable cardioverter-defibrillator (ICD) therapy. BACKGROUND: CTO is a significant problem in patients with ischemic heart disease. However, the extent to which it predisposes affected individuals to VT/VF and whether these arrhythmic events could be prevented by revascularization are unclear. Therefore, a systematic review and meta-analysis were conducted to examine the relationship between CTO status and the occurrence of VT/VF or appropriate ICD therapy. METHODS: PubMed and Embase databases were searched until November 16, 2017, identifying 137 studies. RESULTS: Seventeen studies involving 54,594 subjects (mean age, 61 ± 21 years of age, 81% male) with a mean follow-up of 43 ± 31 months were included. The presence of CTO was associated with higher risk of VT/VF or appropriate ICD therapy (adjusted hazard ratio [aHR]: 1.99; 95% confidence interval (CI): 1.53 to 2.59; p < 0.0001, I2 = 3%) but not in cardiac mortality (aHR: 2.59; 95% CI: 0.64 to 10.59; p = 0.18, I2 = 86%) or in all-cause mortality (aHR: 1.70; 95% CI: 0.84 to 3.46; p = 0.14; I2 = 64%). Compared to patients with non-infarct-related CTOs, those with infarct-related CTOs have a higher risk of VT/VF or appropriate ICD therapy (aHR: 2.47; 95% CI: 1.76 to 3.46; p < 0.0001; I2 = 14%), cardiac mortality (aHR: 2.73; 95% CI: 1.02 to 7.30; p < 0.05; I2 = 79%) and higher all-cause mortality (aHR: 1.69; 95% CI: 1.19 to 2.40; p < 0.01; I2 = 40%). Nonrevascularization of CTOs tended to be associated with an increased risk of all-cause mortality compared to successful revascularization (unadjusted HR: 1.52; 95% CI: 0.96 to 2.43; p = 0.08; I2 = 76). CONCLUSIONS: CTOs, especially infarct-related, are associated with high risk of VT/VF or appropriate ICD therapy and mortality. ICD implantation could be beneficial. However, it is not clear that revascularization has an impact on the outcome of patients with CTOs.


Assuntos
Oclusão Coronária , Taquicardia Ventricular , Fibrilação Ventricular , Adulto , Idoso , Idoso de 80 Anos ou mais , Oclusão Coronária/complicações , Oclusão Coronária/epidemiologia , Oclusão Coronária/mortalidade , Desfibriladores Implantáveis , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio , Taquicardia Ventricular/complicações , Taquicardia Ventricular/epidemiologia , Taquicardia Ventricular/mortalidade , Fibrilação Ventricular/complicações , Fibrilação Ventricular/epidemiologia , Fibrilação Ventricular/mortalidade
12.
J Am Soc Echocardiogr ; 29(10): 938-945, 2016 10.
Artigo em Inglês | MEDLINE | ID: mdl-27545445

RESUMO

BACKGROUND: Accurate localization of mitral valve prolapse (MVP) is crucial for surgical planning. Despite improved visualization of the mitral valve by three-dimensional transesophageal echocardiography, image interpretation remains expertise dependent. Manual construction of mitral valve topographic maps improves diagnostic accuracy but is time-consuming and requires substantial manual input. A novel computer-learning technique called Anatomical Intelligence in ultrasound (AIUS) semiautomatically tracks the annulus and leaflet anatomy for parametric analysis. The aims of this study were to examine whether AIUS could improve accuracy and efficiency in localizing MVP among operators with different levels of experience. METHODS: Two experts and four intermediate-level echocardiographers (nonexperts) retrospectively performed analysis of three-dimensional transesophageal echocardiographic images to generate topographic mitral valve models in 90 patients with degenerative MVP. All echocardiographers performed both AIUS and manual segmentation in sequential weekly sessions. The results were compared with surgical findings. RESULTS: Manual segmentation by nonexperts had significantly lower sensitivity (60% vs 90%, P < .001), specificity (91% vs 97%, P = .001), and accuracy (83% vs 95%, P < .001) compared with experts. AIUS significantly improved the accuracy of nonexperts (from 83% to 89%, P = .003), particularly for lesions involving the A3 (from 81% to 94%, P = .006) and P1 (from 78% to 88%, P = .001) segments, presumably related to anatomic variants of the annulus that made tracking more challenging. AIUS required significantly less time for image analysis by both experts (1.9 ± 0.7 vs 9.9 ± 3.5 min, P < .0001) and nonexperts (5.0 ± 0.5 vs 13 ± 1.5 min, P < .0001), especially for complex lesions. CONCLUSIONS: Anatomic assessment of mitral valve pathology by three-dimensional transesophageal echocardiography is experience dependent. A semiautomated algorithm using AIUS improves accuracy and efficiency in localizing MVP by less experienced operators.


Assuntos
Ecocardiografia Tridimensional/métodos , Interpretação de Imagem Assistida por Computador/métodos , Aprendizado de Máquina , Prolapso da Valva Mitral/diagnóstico por imagem , Prolapso da Valva Mitral/patologia , Reconhecimento Automatizado de Padrão/métodos , Algoritmos , Feminino , Humanos , Aumento da Imagem/métodos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
14.
Int J Cardiol ; 199: 232-8, 2015 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-26209825

RESUMO

BACKGROUND: Quantitative analysis of mitral valve morphology with three-dimensional (3D) transesophageal echocardiography (TEE) provides anatomic information that can assist clinical decision-making. However, routine use of mitral valve quantification has been hindered by tedious workflow and high operator-dependence. The purpose of this paper was to evaluate the feasibility, accuracy and efficiency of a novel computer-learning algorithm using anatomical intelligence in ultrasound (AIUS) to automatically detect and quantitatively assess the mitral valve anatomy. METHODS: A novice operator used AIUS to quantitatively assess mitral valve anatomy on the 3D TEE images of 55 patients (33 with mitral valve prolapse, 11 with functional mitral regurgitation, and 11 normal valves). The results were compared to that of manual mitral valve quantification by an experienced 3D echocardiographer and, in the 24 patients who underwent mitral valve repair, the surgical findings. Time consumption and reproducibility of AIUS were compared to the manual method. RESULTS: AIUS mitral valve quantification was feasible in 52 patients (95%). There were excellent agreements between AIUS and expert manual quantification for all mitral valve anatomic parameters (r=0.85-0.99, p<0.05). AIUS accurately classified surgically defined location of prolapse in 139 of 144 segments analyzed (97%). AIUS improved the intra- [intraclass-correlation coefficient (ICC)=0.91-0.99] and inter-observer (ICC=0.86-0.98) variability of novice users, surpassing the manual approach (intra-observer ICC=0.32-0.95; inter-observer ICC=0.45-0.93), yet requiring significantly less time (144±24s vs. 770±89s, p<0.0001). CONCLUSION: Anatomic intelligence in 3D TEE image can provide accurate, reproducible, and rapid quantification of the mitral valve anatomy.


Assuntos
Algoritmos , Ecocardiografia Tridimensional/métodos , Ecocardiografia Transesofagiana/métodos , Insuficiência da Valva Mitral/diagnóstico por imagem , Prolapso da Valva Mitral/diagnóstico por imagem , Valva Mitral/diagnóstico por imagem , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes