1.
J Nanobiotechnology ; 22(1): 143, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38561800

RESUMO

BACKGROUND: Endoscopic submucosal dissection (ESD) is the current standard treatment for early-stage esophageal neoplasms. However, the postoperative esophageal stricture after extensive mucosal dissection remains a severe challenge with limited effective treatments available. In this study, we introduced a chitosan/gelatin (ChGel) sponge encapsulating the adipose mesenchymal stem cells (ADMSCs)-derived exosomes (ChGelMSC-Exo) for the prevention of esophageal stenosis after ESD in a porcine model. RESULTS: Pigs were randomly assigned into (1) ChGelMSC-Exo treatment group, (2) ChGelPBS group, and (3) the controls. Exosome treatments were applied immediately on the day after ESD as well as on day 7. Exosome components crucial for wound healing were investigated by liquid chromatography-tandem mass spectrometry (LC-MS/MS) and small RNA sequencing. ChGelMSC-Exo treatment significantly reduced mucosal contraction on day 21, with less fiber accumulation and inflammatory infiltration, and enhanced angiogenesis when compared with the control and ChGelPBS groups. The anti-fibrotic effects following MSC-Exo treatment were further found to be associated with the anti-inflammatory M2 polarization of the resident macrophages, especially within the M2b subset characterized by the reduced TGFß1 secretion, which sufficiently inhibited inflammation and prevented the activation of myofibroblast with less collagen production at the early stage after ESD. Moreover, the abundant expression of exosomal MFGE8 was identified to be involved in the transition of the M2b-macrophage subset through the activation of MFGE8/STAT3/Arg1 axis. CONCLUSIONS: Our study demonstrates that exosomal MFGE8 significantly promotes the polarization of the M2b-macrophage subset, consequently reducing collagen deposition. These findings suggest a promising potential for MSC-Exo therapy in preventing the development of esophageal stricture after near-circumferential ESD.


Assuntos
Ressecção Endoscópica de Mucosa , Estenose Esofágica , Exossomos , Células-Tronco Mesenquimais , Suínos , Animais , Estenose Esofágica/etiologia , Estenose Esofágica/prevenção & controle , Ressecção Endoscópica de Mucosa/métodos , Cromatografia Líquida , Espectrometria de Massas em Tandem , Colágeno
2.
VideoGIE ; 9(2): 72-74, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38357024

RESUMO

Video 1Summary of the presented case. Macroscopic images of the lesion in a white-light endoscopy and narrow-band imaging and in an underwater view followed by scenes from the resection with circular marking, submucosal injection, circumferential incision, and submucosal dissection using a multi-bend double-channel endoscope, as well as clip traction, controlled full-thickness dissection, and inspection of the defect plus closure of the defect with the clip-and-loop technique.

3.
Sci Robot ; 9(87): eadh1978, 2024 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-38381838

RESUMO

Micro/nanorobotic swarms consisting of numerous tiny building blocks show great potential in biomedical applications because of their collective active delivery ability, enhanced imaging contrast, and environment-adaptive capability. However, in vivo real-time imaging and tracking of micro/nanorobotic swarms remain a challenge, considering the limited imaging size and spatial-temporal resolution of current imaging modalities. Here, we propose a strategy that enables real-time tracking and navigation of a microswarm in stagnant and flowing blood environments by using laser speckle contrast imaging (LSCI), featuring full-field imaging, high temporal-spatial resolution, and noninvasiveness. The change in dynamic convection induced by the microswarm can be quantitatively investigated by analyzing the perfusion unit (PU) distribution, offering an alternative approach to investigate the swarm behavior and its interaction with various blood environments. Both the microswarm and surrounding environment were monitored and imaged by LSCI in real time, and the images were further analyzed for simultaneous swarm tracking and navigation in the complex vascular system. Moreover, our strategy realized real-time tracking and delivery of a microswarm in vivo, showing promising potential for LSCI-guided active delivery of microswarm in the vascular system.


Assuntos
Imagem de Contraste de Manchas a Laser , Robótica , Fluxometria por Laser-Doppler/métodos , Fluxo Sanguíneo Regional
4.
Korean J Gastroenterol ; 83(6): 217-232, 2024 Jun 25.
Artigo em Coreano | MEDLINE | ID: mdl-38918035

RESUMO

Antithrombotic agents, including antiplatelet agent and anticoagulants are widely used in Korea due to increasing incidence of cardio-cerebrovascular disease and aging population. The management of patients using antithrombotic agents during endoscopic procedures is an important clinical challenge. Clinical practice guideline regarding this issue which was developed by the Korean Society of Gastrointestinal Endoscopy was published in 2020. However, since then, new evidence has emerged for the use of dual antiplatelet therapy and direct anticoagulant management, and revised guidelines were issued in the US and Europe. Accordingly, the previous guidelines were revised, cardiologists also participated in the development group, and the recommendations went through a consensus process among international experts. This guideline presents 14 recommendations made according to the Grading of Recommendations, Assessment, Development, and Evaluation methodology, and was reviewed by multidisciplinary experts. This guideline provides useful information that can assist endoscopists in the management of patients on antithrombotic agents who require diagnostic and elective therapeutic endoscopy. It will be revised as necessary to cover changes in technology, evidence, or other aspects of clinical practice.


Assuntos
Anticoagulantes , Endoscopia Gastrointestinal , Fibrinolíticos , Inibidores da Agregação Plaquetária , Humanos , Fibrinolíticos/uso terapêutico , Inibidores da Agregação Plaquetária/uso terapêutico , Anticoagulantes/uso terapêutico , Consenso , Hemorragia Gastrointestinal
5.
Clin Endosc ; 57(2): 141-157, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38556472

RESUMO

Antithrombotic agents, including antiplatelet agents and anticoagulants, are widely used in Korea because of the increasing incidence of cardiocerebrovascular disease and the aging population. The management of patients using antithrombotic agents during endoscopic procedures is an important clinical challenge. The clinical practice guidelines for this issue, developed by the Korean Society of Gastrointestinal Endoscopy, were published in 2020. However, new evidence on the use of dual antiplatelet therapy and direct anticoagulant management has emerged, and revised guidelines have been issued in the United States and Europe. Accordingly, the previous guidelines were revised. Cardiologists were part of the group that developed the guideline, and the recommendations went through a consensus-reaching process among international experts. This guideline presents 14 recommendations made based on the Grading of Recommendations, Assessment, Development, and Evaluation methodology and was reviewed by multidisciplinary experts. These guidelines provide useful information that can assist endoscopists in the management of patients receiving antithrombotic agents who require diagnostic and elective therapeutic endoscopy. It will be revised as necessary to cover changes in technology, evidence, or other aspects of clinical practice.

6.
Sci Adv ; 10(5): eadk8970, 2024 Feb 02.
Artigo em Inglês | MEDLINE | ID: mdl-38295172

RESUMO

Micro/nanorobots provide a promising approach for intravascular therapy with high precision. However, blood vessel is a highly complex system, and performing interventional therapy in those submillimeter segments remains challenging. While micro/nanorobots can enter submillimeter segments, they may still comprise nonbiodegradable parts, posing a considerable challenge for post-use removal. Here, we developed a retrievable magnetic colloidal microswarm, composed of tPA-anchored Fe3O4@mSiO2 nanorobots (tPA-nbots), to archive tPA-mediated thrombolysis under balloon catheter-assisted magnetic actuation with x-ray fluoroscopy imaging system (CMAFIS). By deploying tPA-nbot transcatheter to the vicinity of the thrombus, the tPA-nbot microswarms were magnetically actuated to the blood clot at the submillimeter vessels with high precision. After thrombolysis, the tPA-nbots can be retrieved via the CMAFIS, as demonstrated in ex vivo organ of human placenta and in vivo carotid artery of rabbit. The proposed colloidal microswarm provides a promising robotic tool with high spatial precision for enhanced thrombolysis with low side effects.


Assuntos
Artérias , Ativador de Plasminogênio Tecidual , Animais , Humanos , Coelhos , Ativador de Plasminogênio Tecidual/uso terapêutico
7.
Sci Adv ; 9(50): eadj0883, 2023 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-38100592

RESUMO

The magnetic microrobots promise benefits in minimally invasive cell-based therapy. However, they generally suffer from an inevitable compromise between their magnetic responsiveness and biomedical functions. Herein, we report a modularized microrobot consisting of magnetic actuation (MA) and cell scaffold (CS) modules. The MA module with strong magnetism and pH-responsive deformability and the CS module with cell loading-release capabilities were fabricated by three-dimensional printing technique. Subsequently, assembly of modules was performed by designing a shaft-hole structure and customizing their relative dimensions, which enabled magnetic navigation in complex environments, while not deteriorating the cellular functionalities. On-demand disassembly at targeted lesion was then realized to facilitate CS module delivery and retrieval of the MA module. Furthermore, the feasibility of proposed system was validated in an in vivo rabbit bile duct. Therefore, this work presents a modular design-based strategy that enables uncompromised fabrication of multifunctional microrobots and stimulates their development for future cell-based therapy.


Assuntos
Terapia Baseada em Transplante de Células e Tecidos , Sistemas de Liberação de Medicamentos , Animais , Coelhos , Sistemas de Liberação de Medicamentos/métodos , Impressão Tridimensional
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA