Ann Vasc Surg ; 99: 312-319, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37858668

RESUMO

BACKGROUND: Limb occlusion is a potentially serious consequence of endovascular abdominal aortic aneurysm (EVAR). This case-control study identifies factors that predispose to limb occlusion. METHODS: A consecutive series of patients from 2 centers undergoing EVAR over an 11-year period 2007-2017 were identified retrospectively. Patient records were interrogated allowing collations of demographics, intraoperative and perioperative data and surveillance data. The preoperative computed tomography angiogram was analyzed to determine EVAR relevant anatomical data. The primary outcome was occlusion of the iliac limb of the implanted EVAR. Raw data are presented as percentages, with comparative data analyzed using Mann-Whitney U-test and binomial logistic regression. RESULTS: A total of 787 patients (702 males; median age 78 years, range 53-94 years old) were analyzed. Fifty patients reached the primary outcome, resulting in an overall limb occlusion rate of 6.35%. Factors predictive of limb occlusion were oversizing by >10% native vessel diameter, with oversizing of >20% in 50% of those that occluded. External iliac artery landing zone (12/50 limb occlusions) 24% and postoperative kinking (5/50 limb occlusions) 10% were also more common in those that occluded. Fifty randomly selected controls with similar baseline characteristics were studied. Oversizing of the iliac endograft was found to be significantly greater in the limb occlusion group compared to the controls (P < 0.001) which remained significant on regression analysis. There was no correlation with iliac tortuosity. The Cook stent graft had a 9% limb occlusion rate across sites. Medtronic and Vascutek endografts had 2.4% and 2.5% limb occlusion rates respectively. CONCLUSIONS: Oversizing of iliac limbs by >20% could be a contributing factor to limb occlusion after EVAR and judicious oversizing should be used.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Masculino , Humanos , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Prótese Vascular , Estudos Retrospectivos , Estudos de Casos e Controles , Oclusão de Enxerto Vascular/cirurgia , Resultado do Tratamento , Stents , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Procedimentos Endovasculares/efeitos adversos , Implante de Prótese Vascular/efeitos adversos , Fatores de Risco , Desenho de Prótese
2.
Ann Vasc Surg ; 61: 278-283, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31336160

RESUMO

BACKGROUND: The aim of the study is to determine whether performing endovascular aortic aneurysm repair (EVAR) in a dedicated vascular hybrid operating room (OR) is associated with a decreased patient radiation and contrast dose compared with mobile C-arm imaging in a conventional OR. METHODS: This is a retrospective study of patients undergoing standard EVAR from 2009-2016. "Standard EVAR" was defined as the elective EVAR performed with bifurcated graft for infrarenal aneurysm with no iliac aneurysms. Patients were divided into 2 groups. Group 1 included EVARs performed in conventional theater with a mobile C-arm (January 2009 to June 2012) and group 2 EVARs performed in the dedicated vascular hybrid OR (July 2012 to December 2016). Data collected included patient demographics, aneurysm diameter, neck length, radiation dose, screening time, and contrast use of each patient. RESULTS: There were 286 patients, 78 and 208 patients in group 1 and 2, respectively. There was no difference in age (77.6 years [76.3-78.9] vs. 76.6 years [75.9-77.9], P > 0.05), body mass index (26.5 kg/m2 [25.1-28.0] vs. 27.9 kg/m2 [27.1-28.7] P > 0.05), and mean aneurysm diameter (6.48 cms [6.13-6.82] vs. 6.81 cms [6.0-7.7], P > 0.05) between groups. Patients in group 2 received approximately half the mean radiation dose (16,807 cGy cm2 [±11,078] vs. 8,233 cGy cm2 [±7,471], P < 0.001), shorter fluoroscopy time (36.02 min [±21.3] vs. 26.96 min [±19], P = 0.001), and less contrast use (114 mls [±44.2] vs. 158 mls [±63.9], P < 0.001). CONCLUSIONS: Performing EVAR in a dedicated vascular Hybrid OR may be associated with a lower patient radiation dose, shorter screening time, and less contrast use than performing EVAR in a conventional OR.


Assuntos
Aneurisma Aórtico/cirurgia , Aortografia , Implante de Prótese Vascular , Angiografia por Tomografia Computadorizada , Meios de Contraste/administração & dosagem , Procedimentos Endovasculares , Salas Cirúrgicas , Doses de Radiação , Exposição à Radiação , Radiografia Intervencionista , Idoso , Aneurisma Aórtico/diagnóstico por imagem , Aortografia/efeitos adversos , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Angiografia por Tomografia Computadorizada/efeitos adversos , Meios de Contraste/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Inglaterra , Feminino , Hospitais Gerais , Humanos , Masculino , Valor Preditivo dos Testes , Exposição à Radiação/efeitos adversos , Exposição à Radiação/prevenção & controle , Radiografia Intervencionista/efeitos adversos , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Stents , Resultado do Tratamento
3.
J Vasc Surg ; 53(5): 1265-73, 2011 May.
Artigo em Inglês | MEDLINE | ID: mdl-21215558

RESUMO

OBJECTIVE: This randomized controlled trial investigated the effects of upper- and lower-limb aerobic exercise training on disease-specific functional status and generic health-related quality of life (QOL) in patients with intermittent claudication. METHODS: The study recruited 104 patients (mean age, 68 years; range, 50-85) from the Sheffield Vascular Institute. Patients were randomly allocated to groups that received upper-limb (ULG) or lower-limb (LLG) aerobic exercise training, or to a nonexercise control group. Exercise was performed twice weekly for 24 weeks at equivalent limb-specific relative exercise intensities. Main outcome measures were scores on the Walking Impairment Questionnaire (WIQ) for disease-specific functional status, the Medical Outcomes Study Short Form version 2 (SF-36v2), and European Quality of Life Visual Analog Scale (EQ-VAS) for health-related QOL. Outcomes were assessed at baseline, and at 6, 24, 48, and 72 weeks. RESULTS: After 6 weeks, improvements in the perceived severity of claudication (P = .023) and stair climbing ability (P = .011) vs controls were observed in the ULG, and an improvement in the general health domain of the SF-36v2 vs controls was observed in the LLG (P = .010). After 24 weeks, all four WIQ domains were improved in the ULG vs controls (P ≤ .05), and three of the four WIQ domains were improved in the LLG (P < .05). After 24 to 72 weeks of follow-up, more consistent changes in generic health-related QOL domains were apparent in the ULG. CONCLUSIONS: These findings support the use of alternative, relatively pain-free forms of exercise in the clinical management of patients with intermittent claudication.


Assuntos
Terapia por Exercício , Claudicação Intermitente/terapia , Músculo Esquelético/fisiopatologia , Doença Arterial Periférica/terapia , Qualidade de Vida , Idoso , Idoso de 80 Anos ou mais , Inglaterra , Feminino , Humanos , Claudicação Intermitente/etiologia , Claudicação Intermitente/fisiopatologia , Claudicação Intermitente/psicologia , Extremidade Inferior , Masculino , Pessoa de Meia-Idade , Doença Arterial Periférica/complicações , Doença Arterial Periférica/fisiopatologia , Doença Arterial Periférica/psicologia , Recuperação de Função Fisiológica , Inquéritos e Questionários , Fatores de Tempo , Resultado do Tratamento , Extremidade Superior , Caminhada
4.
Int J Vasc Med ; 2018: 4305781, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30581625

RESUMO

Atherosclerosis is an inflammatory process resulting in local plaque deposition in the vessel wall of arteries with symptoms to various areas of vascular tree. Identification of patients with progressive advanced atherosclerotic disease is mainly based on the known characteristics of the vulnerable or recently ruptured plaque. Molecular and cellular features associated with the vulnerable plaque are considered potential diagnostic markers for plaque rupture and thrombosis. Here, protein expression levels of the metalloproteases MMP-1, MMP-9, osteopontin (OPN), and cytokines TNFα and IL-6 in tissue extracts of carotid plaques in patients after endarterectomy were estimated by Western immunoblotting, after SDS-PAGE analysis and evaluated based on the ultrasonographic plaque morphology. The gender and age effect was also examined. MMP-1, MMP-9, and IL-6 were expressed in higher levels compared to OPN and TNFa as well as in symptomatic (with type II and III carotid plaque classification) than asymptomatic (type IV) patients with differences considered statistically significant (P values <0.05). A significant positive correlation between MMP-1 and IL-6 (with Pearson correlation coefficient 0.748) is also notable. The data give further insight into the possible role of specific biomarker and enhance the need for further studies in order to clarify the proper one(s) for detection of the vulnerable plaque and help identify patients at risk for cardiovascular events.

5.
Case Rep Med ; 2009: 687982, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19721705

RESUMO

Coronary-subclavian steal syndrome results from atherosclerotic disease of the proximal subclavian artery causing reversal of flow in an internal mammary artery used as conduit for coronary artery bypass. This rare complication of cardiac revascularisation leads to recurrence of myocardial ischaemia. When feasible, subclavian angioplasty and/or stent placement can provide acceptable result for these patients. Vascular reconstruction through carotid to subclavian artery bypass has been the standard procedure of choice. Other interventions in literature include axilloaxillary bypass and subclavian carotid transposition. This case report describes the use of carotid axillary artery bypass for the treatment of coronary-subclavian steal syndrome.

6.
J Vasc Surg ; 42(6): 1122-30, 2005 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-16376202

RESUMO

OBJECTIVES: To investigate the effects of a 24-week program of upper- and lower-limb aerobic exercise training on walking performance in patients with symptomatic peripheral arterial disease (PAD) and to study the mechanisms that could influence symptomatic improvement. METHODS: After approval from the North Sheffield Local Research Ethics Committee, 104 patients (median age, 69 years; range, 50 to 85 years) with stable PAD were randomized into an upper- or lower-limb aerobic exercise training group (UL-Ex or LL-Ex), or to a nonexercise training control group. Training was performed twice weekly for 24 weeks at equivalent relative exercise intensities. An incremental arm- and leg-crank test (ACT and LCT) to maximum exercise tolerance was performed before and at 6, 12, 18, and 24 weeks of the intervention to determine peak oxygen consumption (VO(2)). Walking performance, defined as the claudicating distance (CD) and maximum walking distance (MWD) achieved before intolerable claudication pain, was assessed at the same time points by using a shuttle-walk protocol. Peak blood lactate concentration, Borg ratings of perceived exertion (RPE) and pain category ratio (CR-10) were recorded during all assessments. RESULTS: CD and MWD increased over time (P < .001) in both training groups. At 24 weeks, CD had improved by 51% and 57%, and MWD had improved by 29% and 31% (all P < .001) in the UL-Ex and LL-Ex groups, respectively. An increase in peak heart rate at MWD in the UL-Ex group (109 +/- 4 vs 115 +/- 4 beats/min; P < .01) and LL-Ex group (107 +/- 3 vs 118 +/- 3 beats/min; P = .01) was accompanied by an increase in the amount of pain experienced in both groups (P < .05), suggesting that exercising patients could tolerate a higher level of cardiovascular stress and an increased intensity of claudication pain before test termination after training. Patients assigned to exercise training also showed an increase in LCT peak VO2 at the 24-week time point in relation to baseline (P < .01) and control patients (P < .01), whereas ACT peak VO2 was only improved in the UL-Ex group (P < .05). CONCLUSIONS: Our results suggest that a combination of physiologic adaptations and improved exercise pain tolerance account for the improvement in walking performance achieved through upper-limb aerobic exercise training in patients with PAD. Furthermore, that both arm- and leg-crank training could be useful exercise training modalities for improving cardiovascular function, walking performance, and exercise pain tolerance in patients with symptomatic PAD.


Assuntos
Braço , Arteriopatias Oclusivas/reabilitação , Terapia por Exercício/métodos , Tolerância ao Exercício/fisiologia , Perna (Membro) , Idoso , Idoso de 80 Anos ou mais , Arteriopatias Oclusivas/sangue , Arteriopatias Oclusivas/fisiopatologia , Biomarcadores/sangue , Feminino , Humanos , Ácido Láctico/sangue , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento , Caminhada/fisiologia