Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 40
Filtrar
1.
J Vasc Interv Radiol ; 32(3): 466-471, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33334666

RESUMO

PURPOSE: To evaluate the safety of outpatient percutaneous endovascular abdominal aortic repair (PEVAR) versus inpatient PEVAR without or with adjunct procedures. MATERIALS AND METHODS: Between January 2012 and June 2019, a cohort of 359 patients comprising 168 (46.8%) outpatients and 191 (53.2%) inpatients who had undergone PEVAR were enrolled. All the patients were asymptomatic but had indications for endovascular aortic repair, ie, fit for intravenous anesthesia and anatomically feasible with standard devices. Patient sex, age, comorbidities, smoking status, type of anesthesia, adjunct procedures, type of graft device, operative times, mortality, complications, and readmissions were analyzed. RESULTS: Median follow-up period was 16.5 months (interquartile range, 9-31 months). Except for a higher percentage of tobacco use (42.6% vs 28.8%; P = .04), dyslipidemia (39.7% vs 19.2%; P < .01), and use of local anesthesia (99.4% vs 82.2%; P < .01) in the outpatients, there was no significant difference in the type of graft and adjunct procedures used. No outpatient mortality occurred. There was no difference in the number, severity, and onset of complications (all P > .05). Outpatient unexpected same-day admission, 30-day readmission, and emergency department visit rates were 4.8%, 2.4% (P = .13), and 10% (P < .01), respectively. Operative times for outpatient PEVAR without adjunct procedures were shorter (P < .01). CONCLUSIONS: Outpatient PEVAR can be performed with a safety profile similar to that of inpatient PEVAR. The unexpected same-day admission, 30-day readmission, and emergency department visit rates were low. The outpatient PEVARs without adjunct procedures took less time.


Assuntos
Procedimentos Cirúrgicos Ambulatórios , Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular , Procedimentos Endovasculares , Pacientes Internados , Pacientes Ambulatoriais , Idoso , Idoso de 80 Anos ou mais , Procedimentos Cirúrgicos Ambulatórios/efeitos adversos , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Serviço Hospitalar de Emergência , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Admissão do Paciente , Readmissão do Paciente , Segurança do Paciente , Complicações Pós-Operatórias/terapia , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
2.
Ann Vasc Surg ; 74: 141-147, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33508462

RESUMO

PURPOSE: To evaluate the short-term outcome of totally percutaneous endovascular aortic repair (pEVAR) of ruptured abdominal aortic aneurysms (AAAs) compared with femoral cut-down endovascular aortic repair (cEVAR). MATERIALS AND METHODS: The medical records of patients with ruptured AAAs that underwent EVAR between March 2010 and April 2017 were retrospectively reviewed. Demographic information, preoperative vital signs, preoperative laboratory data, method of anesthesia, procedure duration, aneurysm morphology, brand of device used, length of hospital stay, access complications, and short-term outcomes were recorded. Univariate as well as multivariate logistic regression was used to identify predictors of 30-day mortality. RESULTS: Among 77 patients with ruptured AAAs, 17 (22.1%) received cEVAR and 60 (77.9%) received pEVAR. Significant differences in the procedure time (P = 0.004), method of anesthesia (P = 0.040), and 30-day mortality (P = 0.037) were detected between the cEVAR and pEVAR groups. Local anesthesia plus intravenous general anesthesia (odds ratio = 0.141, P = 0.018) was an independent factor associated with 30-day mortality and local anesthesia was better than general anesthesia for 24-hr mortality (P = 0.001) and 30-day mortality (P = 0.003). CONCLUSION: In patients with ruptured AAAs, pEVAR procedures took less time than cEVAR procedures, but the length of hospital stay did not differ significantly. The 30-day mortality rate was lower with pEVAR than with cEVAR. Local anesthesia may be the key factor in EVAR to improved technical and clinical success.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Ruptura Aórtica/cirurgia , Procedimentos Endovasculares/métodos , Idoso , Aneurisma da Aorta Abdominal/mortalidade , Ruptura Aórtica/mortalidade , Feminino , Artéria Femoral/cirurgia , Humanos , Tempo de Internação , Modelos Logísticos , Masculino , Duração da Cirurgia , Reoperação/estatística & dados numéricos , Estudos Retrospectivos
3.
J Surg Oncol ; 121(1): 75-84, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31273800

RESUMO

BACKGROUND: Retroperitoneal lymphangiomatosis (RL) is a rare form of primary lymphedema featuring aberrant retroperitoneal lymphatic proliferation. It causes recurrent cellulitis, repeated interventions, and poor life quality. This study aimed to investigate proper diagnositc criteria and surgical outcomes for RL with extremity lymphedema. METHODS: Between 2012 and 2018, 44 primary lower-extremity lymphedema cases received lymphoscintigraphy, magnetic resonance imaging, and single-photon electron computed tomography to detect RL. RL patients underwent vascularized lymph node transfers (VLNT) for extremity lymphedema and intra-abdominal side-to-end chylovenous bypasses (CVB) for chylous ascites. Complications, CVB patency, and quality of life were evaluated postoperatively. RESULTS: Six RL patients (mean age of 30.3 years) had chylous ascites with five had lower-extremity lymphedema. All CVBs remained patent, though one required re-anastomosis, giving a 100% patency rate. Four unilateral and one bilateral extremity lymphedema underwent six VLNTs with 100% flap survival. Patients reported improved quality of life (P = 0.023), decreased cellulitis incidence (P = 0.041), and improved mean lymphedema circumference (P = 0.043). All patients resumed a normal diet and activity. CONCLUSIONS: Evaluating primary lower-extremity lymphedema patients with MRI and SPECT could reveal a 13.6% prevalence of RL and guide treatment of refractory extremity lymphedema. Intra-abdominal CVB with VLNT effectively treated RL with chylous ascites and extremity lymphedema.


Assuntos
Linfonodos/transplante , Linfangioma/cirurgia , Neoplasias Retroperitoneais/cirurgia , Adolescente , Adulto , Feminino , Humanos , Perna (Membro)/diagnóstico por imagem , Perna (Membro)/cirurgia , Linfangioma/diagnóstico por imagem , Imageamento por Ressonância Magnética , Pessoa de Meia-Idade , Neoplasias Retroperitoneais/diagnóstico por imagem , Estudos Retrospectivos , Tomografia Computadorizada de Emissão de Fóton Único , Adulto Jovem
4.
J Vasc Interv Radiol ; 31(6): 969-976, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32414571

RESUMO

PURPOSE: To demonstrate post-treatment computed tomography (CT) findings and outcomes of endovascular aortic repair (EVAR) for mycotic aortic aneurysm (MAA). MATERIALS AND METHODS: Clinical data of patients with MAA who underwent EVAR from June 2010 to December 2017 were retrospectively reviewed. A total of 22 patients were included (19 men and 3 women). The periaortic features of the MAA regression after EVAR were graded and evaluated by follow-up CT. RESULTS: The median follow-up was 36.5 months (range, 0.5-97 months.). The cumulative survival rate at 1 month, 6 months, 1 year, and 5 years was 95.5%, 86.4%, 81.6%, and 73.4%, respectively. The early and late infection-related complication (IRC) rate was 18.2% and 13.6%, respectively. One patient died within 1 month from severe acidosis and shock. Of the other patients, the median time to stable response of the MAA was 6 months (range, 3-36 months). Fourteen patients (66.7%) showed early response of the MAA, while 7 patients (33.3%) showed delayed response. A significant association was observed between delayed response and late IRCs (P = .026). CONCLUSIONS: The post-EVAR periaortic features on follow-up CT aid in monitoring the treatment response of the MAA. Early response of the MAA was associated with a low rate of late IRCs and might aid in adjusting the antibiotic duration after the patient has achieved complete or nearly complete regression of the MAA.


Assuntos
Aneurisma Infectado/cirurgia , Aneurisma Aórtico/cirurgia , Aortografia , Angiografia por Tomografia Computadorizada , Procedimentos Endovasculares , Adulto , Idoso , Idoso de 80 Anos ou mais , Aneurisma Infectado/diagnóstico por imagem , Aneurisma Infectado/mortalidade , Antibacterianos/administração & dosagem , Aneurisma Aórtico/diagnóstico por imagem , Aneurisma Aórtico/mortalidade , Bases de Dados Factuais , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/mortalidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
5.
J Vasc Interv Radiol ; 30(4): 495-502, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30876806

RESUMO

PURPOSE: To evaluate feasibility and effectiveness using the octopus endograft technique to treat complex aortic aneurysms (CAAs). MATERIALS AND METHODS: Endovascular repair of CAAs, including thoracoabdominal aneurysms (TAAAs) and dissections involving major side branches, was performed at a single center from June 2014 to June 2017. Patients included 9 men and 2 women (mean age, 60.5 y; range, 40-89 y) were included. The octopus technique was applied using standard aortic grafts with branch stent grafts to preserve the renovisceral arteries. RESULTS: Aortic pathologies comprised 3 mycotic aneurysms, 2 chronic dissections with acute rupture, 1 progressively enlarging chronic type B dissection, 1 acutely ruptured TAAA, and 4 unruptured TAAAs. Mean procedural and fluoroscopic times were 562 min (range, 324-840 min) and 183 min (range, 73-338 min), respectively. Three patients died within 1 month. Mean duration of follow-up was 26.3 months (range, 8-42 months) for remaining patients. Technical success rate of target vessel stent placement was 89.7% (35/39). Major complication rate was 45.5% (5/11), including 3 deaths, 1 permanent paraplegia, and 1 temporary paraplegia that resolved in 2 months. All 3 mycotic aneurysms with mean duration of follow-up of 29 months (range, 8-42 months) were excluded successfully without endoleak. CONCLUSIONS: The octopus technique is feasible for treatment of CAAs requiring urgent management or with difficult anatomy without the use of available custom-made or off-the-shelf branched devices. The procedure carries substantial morbidity and mortality and requires further investigation for its long-term durability.


Assuntos
Aneurisma Aórtico/cirurgia , Implante de Prótese Vascular/métodos , Procedimentos Endovasculares/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Aneurisma Aórtico/diagnóstico por imagem , Aneurisma Aórtico/mortalidade , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Implante de Prótese Vascular/mortalidade , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Procedimentos Endovasculares/mortalidade , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Estudos Retrospectivos , Stents , Fatores de Tempo , Resultado do Tratamento
6.
Ann Vasc Surg ; 56: 355.e7-355.e9, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30500653

RESUMO

Despite recent advances in surgical techniques and endovascular devices, the management of ruptured type B aortic dissection remains challenging. Herein, we describe a patient with a history of chronic type B aortic dissection who presented to the emergency department with a massive left hemothorax and profound shock. Computed tomography demonstrated a thoracic dissecting aneurysm with false lumen rupture. He underwent emergent thoracic endovascular aortic repair and carotid-carotid crossover bypass in a hybrid operating room. Although the thoracic endovascular aortic repair resulted in suitable sealing over the primary entry tear, aortography revealed prominent retrograde flow through the distal re-entry tear into the false lumen. To depressurize the ruptured aortic segment fully, we implanted a modified candy-plug device in the false lumen and successfully occluded the retrograde flow. This case report illustrates the preliminary experience of using modified candy-plug device to rescue a critical patient with ruptured type B aortic dissection.


Assuntos
Aneurisma Aórtico/cirurgia , Dissecção Aórtica/cirurgia , Implante de Prótese Vascular/métodos , Artérias Carótidas/cirurgia , Procedimentos Endovasculares/métodos , Adulto , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/fisiopatologia , Aneurisma Aórtico/diagnóstico por imagem , Aneurisma Aórtico/fisiopatologia , Aortografia/métodos , Prótese Vascular , Implante de Prótese Vascular/instrumentação , Artérias Carótidas/fisiopatologia , Doença Crônica , Angiografia por Tomografia Computadorizada , Procedimentos Endovasculares/instrumentação , Humanos , Masculino , Desenho de Prótese , Stents , Resultado do Tratamento
7.
BMC Med Imaging ; 19(1): 68, 2019 08 16.
Artigo em Inglês | MEDLINE | ID: mdl-31420022

RESUMO

BACKGROUND: The aim of this study was to compare non-contrast-enhanced 3D phase contrast magnetic resonance angiography (3D PC-MRA) and conventional intravenous administration of contrast media, i.e., contrast-enhanced MRA (CE-MRA), to evaluate the courses of facial arteries for the preparation of vascularized submental lymph node flap (VSLN flap) transfer. METHODS: The head and neck regions of 20 patients with limb lymphedema were imaged using a 3 T MRI scanner. To improve the evaluation of facial artery courses, MRA was fused with anatomical structures generated by high-resolution T1-weighted imaging. The diagnostic and image qualities of facial arteries for VSLN flap planning were independently rated by two radiologists. Interobserver agreement was evaluated using Cohen's kappa. Differences between 3D PC-MRA and CE-MRA in terms of the diagnostic quality of facial arteries were evaluated using McNemar's test. RESULTS: Cohen's kappa indicated fair to good interobserver agreement for the diagnostic and image qualities of the bilateral facial arteries. No significant difference in terms of the diagnostic quality of the left and right facial arteries between 3D PC-MRA and CE-MRA, respectively, was identified. CONCLUSIONS: Non-contrast 3D PC-MRA is a reliable method for the evaluation of facial artery courses prior to VSLN flap transfer and could serve as an alternative to CE-MRA for patients with renal insufficiency or severe adverse reactions to contrast media.


Assuntos
Face/irrigação sanguínea , Linfonodos/irrigação sanguínea , Linfedema/diagnóstico por imagem , Angiografia por Ressonância Magnética/instrumentação , Adolescente , Adulto , Idoso , Criança , Pré-Escolar , Meios de Contraste/administração & dosagem , Face/diagnóstico por imagem , Feminino , Humanos , Linfonodos/cirurgia , Linfedema/cirurgia , Angiografia por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Período Pré-Operatório , Interpretação de Imagem Radiográfica Assistida por Computador , Retalhos Cirúrgicos , Adulto Jovem
8.
Radiology ; 289(3): 759-765, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30106341

RESUMO

Purpose To evaluate the feasibility of cutaneous and subcutaneous limb tissue elasticity measurement in participants with limb lymphedema by using acoustic radiation force impulse (ARFI) elastography. Materials and Methods From July 2015 to June 2017, ARFI elastography was performed in 64 participants with lymphedema (seven men and 57 women; age range, 23-85 years) by using a US system. Tissue stiffness quantification with shear-wave velocity (SWV) was obtained in the cutaneous and subcutaneous limb tissues. Lymphoscintigraphy was the reference standard. Results SWV was significantly higher in limbs with lymphatic obstruction than in unaffected limbs (cutaneous tissue: 2.75 m/sec vs 1.74 m/sec, respectively; subcutaneous tissue: 1.90 m/sec vs 1.35 m/sec, respectively; P < .001). SWV was significantly different among limbs without lymphatic drainage obstruction, with partial obstruction, and with total obstruction (cutaneous tissue: 1.74 m/sec vs 2.75 m/sec vs 2.77 m/sec; subcutaneous tissue: 1.35 m/sec vs 1.90 m/sec vs 1.90 m/sec, respectively; P < .001). By using a cut-off value of 2.10 m/sec and 1.43 m/sec for cutaneous and subcutaneous tissue, respectively, sensitivity was 83.1% (59 of 71) and 80.3% (57 of 71), and specificity was 86.0% (49 of 57) and 70.2% (40 of 57) for manifestation of lymphatic obstruction. The corresponding areas under the receiver operating characteristic curve were 0.91 and 0.83, respectively. Conclusion Acoustic radiation force impulse elastography showed that cutaneous and subcutaneous tissues are stiffer in lymphedematous limbs than in unaffected limbs. Acoustic radiation force impulse elastography is a feasible imaging modality for noninvasive tissue stiffness quantification in limb lymphedema. © RSNA, 2018 Online supplemental material is available for this article.


Assuntos
Técnicas de Imagem por Elasticidade/métodos , Extremidades/diagnóstico por imagem , Extremidades/fisiopatologia , Linfedema/diagnóstico por imagem , Linfedema/fisiopatologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos Transversais , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Adulto Jovem
9.
J Surg Oncol ; 118(6): 941-952, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-30261108

RESUMO

BACKGROUD: The optimal approaches for concurrent vascular lesions with limb lymphedema are not well established. The purpose of the study was to investigate the outcome of the surgical management of lymphedema with concomitant vascular lesions. METHODS: Between August 2010 and November 2015, 15 consecutive patients with extremity lymphedema and concomitant vascular lesions treated with vascularized lymph node flaps were reviewed. The patients had vascular interventions discovered during workup for lymphedema surgery. Outcomes were assessed using circumferential difference (CD) and circumferential reduction rate (CRR) at 12-month and final follow-up visits. RESULTS: Vascular lesions (n = 15) included proximal arterial occlusion ( n = 1), vascular malformation ( n = 2), and proximal venous compression/stenosis ( n = 12). Concomitant vascular lesions had an incidence of 15.8% in patients that underwent vascularized lymph node transfers (VLNTs). We had 100% VLNT survival rate and average number of episodes of cellulitis after VLNTs decreased significantly ( p < 0.05). The CRR for the below knee/elbow measurement at 12-months follow-up was significantly higher for patients that underwent vascular intervention for venous lesions before VLNT instead of concurrently or after (23.7% vs 12.2%, P = 0.23). Final mean CRR was 23.7% and 12.2% respectively. CONCLUSION: Preoperative workup of concomitant vascular lesions is important for lymphedema management. We suggest appropriate vascular intervention should be done prior to VLNT to maximize the short-term and long-term outcomes.


Assuntos
Linfedema/diagnóstico , Linfedema/cirurgia , Doenças Vasculares/diagnóstico , Doenças Vasculares/cirurgia , Adolescente , Adulto , Idoso , Feminino , Humanos , Comunicação Interdisciplinar , Perna (Membro)/irrigação sanguínea , Perna (Membro)/patologia , Perna (Membro)/cirurgia , Pessoa de Meia-Idade , Estudos Retrospectivos , Retalhos Cirúrgicos , Resultado do Tratamento , Adulto Jovem
10.
J Vasc Interv Radiol ; 28(4): 570-575, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28190708

RESUMO

PURPOSE: To evaluate outcomes and predictive factors for additional ProGlide device deployment in percutaneous endovascular aortic repair (PEVAR) with the preclose technique. MATERIALS AND METHODS: Clinical data of patients who underwent PEVAR with the preclose technique from February 2012 to January 2015 were retrospectively reviewed. A total of 268 patients (229 men, 39 women) who underwent PEVAR (thoracic endovascular aortic repair [TEVAR], n = 113; endovascular abdominal aortic repair [EVAR], n = 152; simultaneous TEVAR and EVAR, n = 3) with 418 femoral access sites were enrolled. The mean age of the patients was 69 years ± 14. Univariate and multivariate analyses were performed to identify predictive factors associated with additional ProGlide device deployment. RESULTS: Primary technical success with adequate hemostasis and two ProGlide devices was 87.6%, and 48 femoral arterial access sites (11.5%) required additional ProGlide device deployment. The secondary technical success rate was 99.0%. Four femoral access sites (1.0%) needed surgical repair. Anterior wall calcification near the arteriotomy increased the risk of additional ProGlide device deployment (adjusted odds ratio, 6.19; 95% confidence interval, 2.81-13.64; P < .001), whereas larger sheath size, common femoral artery (CFA) diameter, and depth from the skin to the arteriotomy did not. CONCLUSIONS: Additional ProGlide device deployment reduces the rate of surgical repair after primary hemostasis failure in PEVAR. Anterior CFA wall calcification is a significant predictor for additional ProGlide device deployment.


Assuntos
Aorta Abdominal/cirurgia , Aorta Torácica/cirurgia , Implante de Prótese Vascular , Procedimentos Endovasculares , Hemorragia/prevenção & controle , Técnicas Hemostáticas/instrumentação , Dispositivos de Oclusão Vascular , Idoso , Idoso de 80 Anos ou mais , Aortografia/métodos , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Distribuição de Qui-Quadrado , Angiografia por Tomografia Computadorizada , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Desenho de Equipamento , Feminino , Hemorragia/etiologia , Técnicas Hemostáticas/efeitos adversos , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Razão de Chances , Punções , Estudos Retrospectivos , Fatores de Risco , Stents , Resultado do Tratamento , Dispositivos de Acesso Vascular
12.
Eur Radiol ; 24(2): 460-8, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24081645

RESUMO

OBJECTIVES: To evaluate CT aortography at reduced tube voltage and contrast medium dose while maintaining image quality through iterative reconstruction (IR). METHODS: The Institutional Review Board approved a prospective study of 48 patients who underwent follow-up CT aortography. We performed intra-individual comparisons of arterial phase images using 120 kVp (standard tube voltage) and 80 kVp (low tube voltage). Low-tube-voltage imaging was performed on a 320-detector CT with IR following injection of 40 ml of contrast medium. We assessed aortic attenuation, aortic attenuation gradient, image noise, contrast-to-noise ratio (CNR), volume CT dose index (CTDIvol), and figure of merit (FOM) of image noise and CNR. Two readers assessed images for diagnostic quality, image noise, and artefacts. RESULTS: The low-tube-voltage protocol showed 23-31% higher mean aortic attenuation and image noise (both P < 0.01) than the standard-tube-voltage protocol, but no significant difference in the CNR and aortic attenuation gradients. The low-tube-voltage protocol showed a 48% reduction in CTDIvol and an 80% increase in FOM of CNR. Subjective diagnostic quality was similar for both protocols, but low-tube-voltage images showed greater image noise (P = 0.01). CONCLUSIONS: Application of IR to an 80-kVp CT aortography protocol allows radiation dose and contrast medium reduction without affecting image quality. KEY POINTS: • CT aortography at 80 kVp allows a significant reduction in radiation dose. • Addition of iterative reconstruction reduces image noise and improves image quality. • The injected contrast medium dose can be substantially reduced at 80 kVp. • Aortic enhancement is uniform despite a reduced volume of contrast medium.


Assuntos
Aortografia/métodos , Tomografia Computadorizada de Feixe Cônico/métodos , Meios de Contraste , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Adulto , Idoso , Meios de Contraste/administração & dosagem , Relação Dose-Resposta a Droga , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Estudos Prospectivos , Doses de Radiação
13.
Asian J Surg ; 47(6): 2623-2624, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38531735

RESUMO

TECHNIQUE: The surgical management for high-output postoperative chylothorax typically necessitates ligation of the thoracic duct (TD) above the leak site and/or sealing the leak with a clip. However, pinpointing these structures during subsequent surgeries can be challenging due to their variable course and the presence of traumatized tissues surrounding the leak area. In response to this, we have developed a novel, fluorescence-guided technique that significantly enhances intraoperative identification of the leak point and the TD. This method was applied in the case of a 52-year-old man suffering from refractory chylothorax following a previous lung cancer surgery. This study documents the surgical procedure and includes a video vignette for a comprehensive understanding. RESULTS: A bilateral inguinal lymph node injection of saline (10 mL), guided by ultrasound and containing 2.5 mg/mL indocyanine green (ICG), was administered 20 min prior to surgery. During thoracoscopic exploration, the leak point was precisely pinpointed in the right paratracheal area by transitioning from bright light to fluorescent mode. The TD was clearly identified, and upon ligation, there was no further leakage of fluorescent lymph, indicating a successful closure of the lymphatic structure. The surgery proceeded uneventfully, and the patient was able to resume oral intake on the third postoperative day. There was no evidence of recurring symptoms, leading to his discharge. CONCLUSION: The intralymphatic injection of ICG offers a rapid visualization of the TD's anatomy and can effectively pinpoint the leak point, even amidst traumatized tissues. Moreover, it provides prompt feedback on the efficacy of ligation.


Assuntos
Quilotórax , Verde de Indocianina , Complicações Pós-Operatórias , Cirurgia Torácica Vídeoassistida , Humanos , Quilotórax/cirurgia , Quilotórax/etiologia , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/cirurgia , Verde de Indocianina/administração & dosagem , Cirurgia Torácica Vídeoassistida/métodos , Fluorescência , Ligadura/métodos , Ducto Torácico/cirurgia , Neoplasias Pulmonares/cirurgia , Cirurgia Assistida por Computador/métodos
14.
Biomed Pharmacother ; 169: 115928, 2023 Dec 31.
Artigo em Inglês | MEDLINE | ID: mdl-38011788

RESUMO

Neoantigen-reactive cytotoxic T lymphocytes play a vital role in precise cancer cell elimination. In this study, we demonstrate the effectiveness of personalized neoantigen-based T cell therapy in inducing tumor regression in two patients suffering from heavily-burdened metastatic ovarian cancer. Our approach involved the development of a robust pipeline for ex vivo expansion of neoantigen-reactive T lymphocytes. Neoantigen peptides were designed and synthesized based on the somatic mutations of the tumors and their predicted HLA binding affinities. These peptides were then presented to T lymphocytes through co-culture with neoantigen-loaded dendritic cells for ex vivo expansion. Subsequent to cell therapy, both patients exhibited significant reductions in tumor marker levels and experienced substantial tumor regression. One patient achieved repeated cancer regression through infusions of T cell products generated from newly identified neoantigens. Transcriptomic analyses revealed a remarkable increase in neoantigen-reactive cytotoxic lymphocytes in the peripheral blood of the patients following cell therapy. These cytotoxic T lymphocytes expressed polyclonal T cell receptors (TCR) against neoantigens, along with abundant cytotoxic proteins and pro-inflammatory cytokines. The efficacy of neoantigen targeting was significantly associated with the immunogenicity and TCR polyclonality. Notably, the neoantigen-specific TCR clonotypes persisted in the peripheral blood after cell therapy. Our findings indicate that personalized neoantigen-based T cell therapy triggers cytotoxic lymphocytes expressing polyclonal TCR against ovarian cancer, suggesting its promising potential in cancer immunotherapy.


Assuntos
Neoplasias Ovarianas , Receptores de Antígenos de Linfócitos T , Humanos , Feminino , Linfócitos T Citotóxicos/metabolismo , Antígenos de Neoplasias , Neoplasias Ovarianas/terapia , Peptídeos
15.
Biomedicines ; 10(5)2022 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-35625773

RESUMO

At present, iodinated contrast media (ICM) are mostly non-ionic, have low osmolality, and are safe. Even if adverse drug reactions (ADRs) occur, most are chemo-toxic symptoms and require only observation or H1 antihistamines. However, rare, unpredictable, and even life-threatening hypersensitivity can still occur. The aim of this review is to summarize the issues that all relevant staff need to know about and be able to respond to. The most significant risk factor for ICM hypersensitivity is a history of ICM hypersensitivity. For high-risk populations, we must cautiously weigh the advantages and disadvantages of premedication and be aware that breakthrough reactions may still occur. The best policy for patients with a history of severe ICM hypersensitivity is to avoid the same ICM. If ICM are inevitable, skin tests, in vitro tests, and drug provocation tests may help to find a feasible alternative that is safer. The severity of the hypersensitivity is correlated with the positivity rate of these tests, so there is no need for further investigations for patients with only mild reactions. We should also keep in mind that even excipients in ICM may induce hypersensitivity. Detailed, standardized documentation is essential for correct diagnosis and the prevention of future occurrence.

16.
Sci Rep ; 12(1): 414, 2022 01 10.
Artigo em Inglês | MEDLINE | ID: mdl-35013540

RESUMO

Osteoporosis is a critical problem during aging. Ultrasound signals backscattered from bone contain information associated with microstructures. This study proposed using entropy imaging to collect the information in bone microstructures as a possible solution for ultrasound bone tissue characterization. Bone phantoms with different pounds per cubic foot (PCF) were used for ultrasound scanning by using single-element transducers of 1 (nonfocused) and 3.5 MHz (nonfocused and focused). Clinical measurements were also performed on lumbar vertebrae (L3 spinal segment) in participants with different ages (n = 34) and postmenopausal women with low or moderate-to-high risk of osteoporosis (n = 50; identified using the Osteoporosis Self-Assessment Tool for Taiwan). The signals backscattered from the bone phantoms and subjects were acquired for ultrasound entropy imaging by using sliding window processing. The independent t-test, one-way analysis of variance, Spearman correlation coefficient rs, and the receiver operating characteristic (ROC) curve were used for statistical analysis. The results indicated that ultrasound entropy imaging revealed changes in bone microstructures. Using the 3.5-MHz focused ultrasound, small-window entropy imaging (side length: one pulse length of the transducer) was found to have high performance and sensitivity in detecting variation among the PCFs (rs = - 0.83; p < 0.05). Small-window entropy imaging also performed well in discriminating young and old participants (p < 0.05) and postmenopausal women with low versus moderate-to-high osteoporosis risk (the area under the ROC curve = 0.80; cut-off value = 2.65; accuracy = 86.00%; sensitivity = 71.43%; specificity = 88.37%). Ultrasound small-window entropy imaging has great potential in bone tissue characterization and osteoporosis assessment.


Assuntos
Vértebras Lombares/diagnóstico por imagem , Osteoporose/diagnóstico por imagem , Processamento de Sinais Assistido por Computador , Ultrassonografia , Adulto , Fatores Etários , Idoso , Densidade Óssea , Entropia , Estudos de Viabilidade , Feminino , Humanos , Vértebras Lombares/fisiopatologia , Pessoa de Meia-Idade , Osteoporose/fisiopatologia , Osteoporose Pós-Menopausa/diagnóstico por imagem , Osteoporose Pós-Menopausa/fisiopatologia , Imagens de Fantasmas , Porosidade , Pós-Menopausa , Valor Preditivo dos Testes , Espalhamento de Radiação , Ultrassonografia/instrumentação
17.
Front Neurosci ; 16: 1015843, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36466181

RESUMO

The dynamic vascular responses during cortical spreading depolarization (CSD) are causally related to pathophysiological consequences in numerous neurovascular conditions, including ischemia, traumatic brain injury, cerebral hemorrhage, and migraine. Monitoring of the hemodynamic responses of cerebral penetrating vessels during CSD is motivated to understand the mechanism of CSD and related neurological disorders. Six SD rats were used, and craniotomy surgery was performed before imaging. CSDs were induced by topical KCl application. Ultrasound dynamic ultrafast Doppler was used to access hemodynamic changes, including cerebral blood volume (CBV) and flow velocity during CSD, and further analyzed those in a single penetrating arteriole or venule. The CSD-induced hemodynamic changes with typical duration and propagation speed were detected by ultrafast Doppler in the cerebral cortex ipsilateral to the induction site. The hemodynamics typically showed triphasic changes, including initial hypoperfusion and prominent hyperperfusion peak, followed by a long-period depression in CBV. Moreover, different hemodynamics between individual penetrating arterioles and venules were proposed by quantification of CBV and flow velocity. The negative correlation between the basal CBV and CSD-induced change was also reported in penetrating vessels. These results indicate specific vascular dynamics of cerebral penetrating vessels and possibly different contributions of penetrating arterioles and venules to the CSD-related pathological vascular consequences. We proposed using ultrasound dynamic ultrafast Doppler imaging to investigate CSD-induced cerebral vascular responses. With this imaging platform, it has the potential to monitor the hemodynamics of cortical penetrating vessels during brain injuries to understand the mechanism of CSD in advance.

18.
J Thorac Cardiovasc Surg ; 163(6): 2012-2021.e6, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-32773121

RESUMO

OBJECTIVE: Thoracic endovascular aortic repair (TEVAR) can be complicated by a type Ia endoleak. However, its natural history remains unclear. This report describes the natural history and midterm outcome of conservatively treated type Ia endoleaks in the proximal aorta. METHODS: Between 2007 and 2015, 395 patients underwent TEVAR at our institution. Only TEVARs landing proximally at landing zones 0, 1, and 2 were included (221/395). Type Ia endoleak's flow was classified as "fast" or "slow" based on the time needed to visualize the aneurysmal sac during arteriogram. RESULTS: The median follow-up was 4.1 years. Aortic dissection, thoracic aortic aneurysm, and traumatic aortic injury were the most common indications for TEVAR; the incidence of type Ia endoleak was not statistically different. Forty-seven patients (21.3%) had a type Ia endoleak. TEVAR landing proximally at zone 1 increased the odds of developing a type Ia endoleak (odds ratio, 2.8; 95% confidence interval, 1.3-5.9; P = .0072). The 30-day mortality and the overall survival was not influenced by the development of immediate-type Ia endoleak. In 34 (72.3%) patients, the endoleak resolved spontaneously. Ninety-four percent of these patients had a SlowE (n = 32/34). All of spontaneous resolutions occurred before the end of the first postoperative year. CONCLUSIONS: SlowE tends to resolve within 1 year after TEVAR. Initial conservative treatment seems to be a reasonable approach in patients with SlowE.


Assuntos
Implante de Prótese Vascular , Procedimentos Endovasculares , Aorta Torácica/cirurgia , Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/efeitos adversos , Endoleak/diagnóstico por imagem , Endoleak/etiologia , Endoleak/cirurgia , Procedimentos Endovasculares/efeitos adversos , Humanos , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
19.
J Int Med Res ; 50(6): 3000605221100134, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35650686

RESUMO

OBJECTIVE: May-Thurner syndrome (MTS) is an anatomic stenotic variation associated with deep vein thrombosis (DVT) of the left leg. The classical DVT treatment strategy is medical treatment without thrombus removal. This study was performed to assess the clinical outcomes of the combination of AngioJet™ rheolytic thrombectomy and stenting for treatment of MTS-related DVT. METHODS: We conducted a retrospective cohort study of patients treated for MTS-related DVT from January 2017 to June 2020 at a single institution. RESULTS: Fourteen patients (nine women) underwent AngioJet™ rheolytic thrombectomy for MTS-related DVT during the study period. The median DVT onset time was 8 days (interquartile range (IQR), 3-21 days). The median procedure time was 130 minutes (IQR, 91-189 minutes), and the median hospital stay was 7 days (IQR, 5-26 days). One patient had a residual thrombus and occluded iliac stent and underwent adjuvant catheter-directed thrombolysis for revascularization. The primary patency rate for the iliac stent was 92.9% at 12 months. CONCLUSION: Concomitant AngioJet™ rheolytic thrombectomy and stenting of MTS-induced lesions may be beneficial for patients with MTS-related DVT.


Assuntos
Síndrome de May-Thurner , Trombose Venosa , Feminino , Humanos , Síndrome de May-Thurner/complicações , Síndrome de May-Thurner/terapia , Estudos Retrospectivos , Trombectomia , Terapia Trombolítica/métodos , Resultado do Tratamento , Grau de Desobstrução Vascular , Trombose Venosa/etiologia , Trombose Venosa/cirurgia
20.
Liver Transpl ; 17(4): 373-80, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21445920

RESUMO

An accurate preoperative estimate of the graft weight is vital to avoid small-for-size syndrome in the recipient and ensure donor safety after adult living donor liver transplantation (LDLT). Here we describe a simple method for estimating the graft volume (GV) that uses the maximal right portal vein diameter (RPVD) and the maximal left portal vein diameter (LPVD). Between June 2004 and December 2009, 175 consecutive donors undergoing right hepatectomy for LDLT were retrospectively reviewed. The GV was determined with 3 estimation methods: (1) the radiological graft volume (RGV) estimated by computed tomography (CT) volumetry; (2) the computed tomography-calculated graft volume (CGV-CT), which was obtained by the multiplication of the standard liver volume (SLV) by the RGV percentage with respect to the total liver volume derived from CT; and (3) the portal vein diameter ratio-calculated graft volume (CGV-PVDR), which was obtained by the multiplication of the SLV by the portal vein diameter ratio [PVDR; ie, PVDR = RPVD(2) /(RPVD(2) + LPVD(2) )]. These values were compared to the actual graft weight (AGW), which was measured intraoperatively. The mean AGW was 633.63 ± 107.51 g, whereas the mean RGV, CGV-CT, and CGV-PVDR values were 747.83 ± 138.59, 698.21 ± 94.81, and 685.20 ± 90.88 cm(3) , respectively. All 3 estimation methods tended to overestimate the AGW (P < 0.001). The actual graft-to-recipient body weight ratio (GRWR) was 1.00% ± 0.19%, and the GRWRs calculated on the basis of the RGV, CGV-CT, and CGV-PVDR values were 1.19% ± 0.25%, 1.11% ± 0.22%, and 1.09% ± 0.21%, respectively. Overall, the CGV-PVDR values better correlated with the AGW and GRWR values according to Lin's concordance correlation coefficient and the Landis and Kock benchmark. In conclusion, the PVDR method is a simple estimation method that accurately predicts GVs and GRWRs in adult LDLT.


Assuntos
Transplante de Fígado , Fígado/anatomia & histologia , Doadores Vivos , Veia Porta/anatomia & histologia , Adulto , Peso Corporal , Feminino , Humanos , Modelos Lineares , Masculino , Tamanho do Órgão , Período Pré-Operatório
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA