Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Tipo de documento
Ano de publicação
Intervalo de ano de publicação
1.
J Zoo Wildl Med ; 51(1): 245-248, 2020 Mar 17.
Artigo em Inglês | MEDLINE | ID: mdl-32212572

RESUMO

Hypervitaminosis D was diagnosed in a giant anteater (Myromecophaga tridactyla) and a large hairy armadillo (Chaetophractus villosus) being fed a commercial insectivore diet. Clinical findings included weight loss, reduced appetite, vomiting, and suspected abdominal discomfort. Hypercalcemia (3.68 and 2.04 mmol/L total and ionized calcium, respectively) was detected in the anteater, and plasma 25(OH)D levels were measured and found to be 808.7 and 379.4 nmol/L for the anteater and armadillo, respectively. Dietary change resulted in a reduction of 25(OH)D levels in both animals and resolution of hypercalcemia in the giant anteater. Dietary analysis of the commercial insectivore food revealed levels of vitamin D3 higher than the data-sheet values. This case report demonstrates that hypervitaminosis D in Xenarthra can be associated with significant clinical signs.


Assuntos
25-Hidroxivitamina D 2/sangue , Distúrbios Nutricionais/veterinária , Vitamina D/sangue , Xenarthra , Animais , Tatus , Dieta/efeitos adversos , Dieta/veterinária , Hipercalcemia/diagnóstico , Hipercalcemia/etiologia , Hipercalcemia/veterinária , Masculino , Distúrbios Nutricionais/diagnóstico , Distúrbios Nutricionais/etiologia
2.
Onderstepoort J Vet Res ; 84(1): e1-e10, 2017 Nov 10.
Artigo em Inglês | MEDLINE | ID: mdl-29227129

RESUMO

Blood lactate is a predictor of mortality in critically ill humans and animals. Handheld lactate meters have the potential to be used in the field to evaluate the condition of severely injured rhinoceroses but have not been compared with laboratory-based methods. Agreement between a handheld lactate meter and a laboratory method was assessed, as was the stability of rhino blood lactate in the anticoagulant sodium fluoride/potassium oxalate (fluoride/oxalate). Blood samples were obtained from 53 white rhinos that had been immobilised for management reasons. Lactate was measured by means of a handheld meter using whole blood in heparin (WBHEP), whole blood in fluoride/oxalate (WBFO) and fluoride/oxalate plasma (PFO). Results were recorded in both blood (BL) and plasma (PL) modes and compared to an established laboratory method for measuring plasma lactate. To assess the stability of lactate over time, blood lactate in fluoride/oxalate was measured on the handheld meter at intervals for up to 91 h. Agreement was best using WBFO in PL mode, with small bias (-0.16), tight 95% limits of agreement (LOA) (-1.46, 1.14) and a Pc (95% CI) of 0.97 (0.92, 0.99). The agreement was improved for all sample types when using the PL mode compared to the blood lactate (BL) mode. Blood lactate was stable in fluoride/oxalate for 91 h, with a mean change from baseline of 0.15 (-0.178, 0.478) mmol/L (mean, 95% CI). The handheld meter was found to be suitable for field use in white rhinos but provided more reliable results with the device in PL mode. Furthermore, rhino blood lactate was found to be stable in fluoride/oxalate for as long as 3 days.


Assuntos
Criação de Animais Domésticos , Biomarcadores/sangue , Ácido Láctico/sangue , Perissodáctilos/sangue , Medicina Veterinária/instrumentação , Animais , Feminino , Hematologia/instrumentação , Masculino , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA