Magn Reson Med ; 81(1): 653-669, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29893997

RESUMO

PURPOSE: To evaluate the local specific absorption rate (SAR) and heating around retained cardiac leads during MRI at 64 MHz (1.5T) and 127 MHz (3T) as a function of RF coil type and imaging landmark. METHODS: Numerical models of retained cardiac leads were built from CT and X-ray images of 6 patients with retained cardiac leads. Electromagnetic simulations and bio-heat modeling were performed with MRI RF body and head coils tuned to 64 MHz and 127 MHz and positioned at 9 different imaging landmarks covering an area from the head to the lower limbs. RESULTS: For all patients and at both 1.5T and 3T, local transmit head coils produced negligible temperature rise ( Δ T < 0.1 ° C ) for ‖ ‖ B 1 + ‖ ‖ ≤ 3 µ T . For body imaging with quadrature-driven coils at 1.5T, Δ T during a 10-min scan remained < 3°C at all imaging landmarks for ‖ ‖ B 1 + ‖ ‖ ≤ 3 µ T and <6°C for ‖ ‖ B 1 + ‖ ‖ ≤ 4 µ T . For body imaging at 3T, Δ T during a 10-min scan remained < 6°C at all imaging landmarks for ‖ ‖ B 1 + ‖ ‖ ≤ 2 µ T . For shorter pulse sequences up to 2 min, Δ T remained < 6°C for ‖ ‖ B 1 + ‖ ‖ ≤ 3 µ T . CONCLUSION: For the models based on 6 patients studied, simulations suggest that MRI could be performed safely using a local head coil at both 1.5T and 3T, and with a body coil at 1.5T with pulses that produced ‖ ‖ B 1 + ‖ ‖ ≤ 4 µ T . MRI at 3T could be performed safely in these patients using pulses with ‖ ‖ B 1 + ‖ ‖ ≤ 2 µ T .


Assuntos
Desfibriladores Implantáveis/efeitos adversos , Remoção de Dispositivo , Corpos Estranhos , Insuficiência Cardíaca/cirurgia , Coração/diagnóstico por imagem , Imageamento por Ressonância Magnética , Ondas de Rádio , Adulto , Algoritmos , Simulação por Computador , Feminino , Análise de Elementos Finitos , Frequência Cardíaca , Transplante de Coração , Temperatura Alta , Humanos , Processamento de Imagem Assistida por Computador , Imageamento Tridimensional , Perna (Membro)/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Marca-Passo Artificial/efeitos adversos , Segurança do Paciente , Complicações Pós-Operatórias/cirurgia , Próteses e Implantes , Reprodutibilidade dos Testes , Estudos Retrospectivos , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA