Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 74
Filtrar
1.
Mass Spectrom Rev ; 42(3): 984-1007, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-34558100

RESUMO

Amylin (islet amyloid polypeptide [IAPP]) is a neuroendocrine hormone synthesized with insulin in the beta cells of pancreatic islets. The two hormones act in different ways: in fact insulin triggers glucose uptake in muscle and liver cells, removing glucose from the bloodstream and making it available for energy use and storage, while amylin regulates glucose homeostasis. Aside these positive physiological aspects, human amyloid polypeptide (hIAPP) readily forms amyloid in vitro. Amyloids are aggregates of proteins and in the human body amyloids are considered responsible of the development of various diseases. These aspects have been widely described and discussed in literature and to give a view of the highly complexity of this biochemical behavior the different physical, chemical, biological and medical aspects are shortly described in this review. It is strongly affected by the presence on metal ions, responsible for or inhibiting the formation of fibrils. Mass spectrometry resulted (and still results) to be a particularly powerful tool to obtain valid and effective experimental data to describe the hIAPP behavior. Aside classical approaches devoted to investigation on metal ion-hIAPP structures, which reflects on the identification of metal-protein interaction site(s) and of possible metal-induced conformational changes of the protein, interesting results have been obtained by ion mobility mass spectrometry, giving, on the basis of collisional cross-section data, information on both the oligomerization processes and the conformation changes. Laser ablation electrospray ionization-ion mobility spectrometry-mass spectrometry (LAESI-IMS-MS), allowed to obtain information on the binding stoichiometry, complex dissociation constant, and the oxidation state of the copper for the amylin-copper interaction. Alternatively to inorganic ions, small organic molecules have been tested by ESI-IMS-MS as inhibitor of amyloid assembly. Also in this case the obtained data demonstrate the validity of the ESI-IMS-MS approach as a high-throughput screen for inhibitors of amyloid assembly, providing valid information concerning the identity of the interacting species, the nature of binding and the effect of the ligand on protein aggregation. Effects of Cu2+ and Zn2+ ions in the degradation of human and murine IAPP by insulin-degrading enzyme were studied by liquid chromatography/mass spectrometry (LC/MS). The literature data show that mass spectrometry is a highly valid and effective tool in the study of the amylin behavior, so to individuate medical strategies to avoid the undesired formation of amyloids in in vivo conditions.


Assuntos
Insulinas , Polipeptídeo Amiloide das Ilhotas Pancreáticas , Camundongos , Humanos , Animais , Polipeptídeo Amiloide das Ilhotas Pancreáticas/química , Polipeptídeo Amiloide das Ilhotas Pancreáticas/metabolismo , Cobre/química , Cobre/metabolismo , Espectrometria de Massas por Ionização por Electrospray , Amiloide/química , Amiloide/metabolismo , Glucose
2.
Hepatology ; 77(5): 1630-1638, 2023 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-36125403

RESUMO

BACKGROUND AND AIMS: Acute kidney injury (AKI) commonly occurs in patients with decompensated cirrhosis. Urinary neutrophil gelatinase-associated lipocalin (uNGAL) could help discriminate between different etiologies of AKI. The aim of this study was to investigate the use of uNGAL in (1) the differential diagnosis of AKI, (2) predicting the response to terlipressin and albumin in patients with hepatorenal syndrome-AKI (HRS-AKI), and (3) predicting in-hospital mortality in patients with AKI. APPROACH AND RESULTS: One hundred sixty-two consecutive patients with cirrhosis and AKI were included from 2015 to 2020 and followed until transplant, death, or 90 days. Standard urinary markers and uNGAL were measured. Data on treatment, type, and resolution of AKI were collected. Thirty-five patients (21.6%) had prerenal AKI, 64 (39.5%) HRS-AKI, 27 (16.7%) acute tubular necrosis-AKI (ATN-AKI), and 36 (22.2%) a mixed form of AKI. Mean values of uNGAL were significantly higher in ATN-AKI than in other types of AKI (1162 ng/ml [95% CI 423-2105 ng/ml] vs. 109 ng/ml [95% CI 52-192 ng/ml]; p  < 0.001). uNGAL showed a high discrimination ability in predicting ATN-AKI (area under the receiver operating characteristic curve, 0.854; 95% CI 0.767-0.941; p  < 0.001). The best-performing threshold was found to be 220 ng/ml (sensitivity, 89%; specificity, 78%). The same threshold was independently associated with a higher risk of nonresponse (adjusted OR [aOR], 6.17; 95% CI 1.41-27.03; p  = 0.016). In multivariable analysis (adjusted for age, Model for End-Stage Liver Disease, acute-on-chronic liver failure, leukocytes, and type of AKI), uNGAL was an independent predictor of in-hospital mortality (aOR, 1.74; 95% CI 1.26-2.38; p  = 0.001). CONCLUSIONS: uNGAL is an adequate biomarker for making a differential diagnosis of AKI in cirrhosis and predicting the response to terlipressin and albumin in patients with HRS-AKI. In addition, it is an independent predictor of in-hospital mortality.


Assuntos
Injúria Renal Aguda , Doença Hepática Terminal , Humanos , Lipocalina-2 , Prognóstico , Doença Hepática Terminal/complicações , Terlipressina , Proteínas de Fase Aguda , Lipocalinas , Proteínas Proto-Oncogênicas , Índice de Gravidade de Doença , Cirrose Hepática/complicações , Cirrose Hepática/diagnóstico , Injúria Renal Aguda/diagnóstico , Injúria Renal Aguda/etiologia , Biomarcadores
3.
Clin Chem Lab Med ; 62(3): 572-577, 2024 Feb 26.
Artigo em Inglês | MEDLINE | ID: mdl-37787733

RESUMO

OBJECTIVES: In this study, we describe the analytical and clinical performances of the SNIBE Maglumi SARS-CoV-2 antigen fully-automated chemiluminescent immunoassay (MAG-CLIA) on salivary samples. METHODS: Limit of detection (LOD), linearity and precision were tested for values close to or below the declared LOD. Clinical performance of MAG-CLIA was evaluated on leftover salivary samples from the healthcare workers (HCW) surveillance program, at the University-Hospital of Padova. Salivary samples were analyzed by Lumipulse G SARS-CoV-2 Ag, and in case where the values exceeded 0.41 ng/L, further testing was conducted using TaqPathTM COVID-19 RT-PCR (Applied Biosystems, Thermo Fisher Scientific). RESULTS: The estimated MAG-CLIA LOD was 3 ng/L, with repeatability of 7.5 %. Good linearity was demonstrated by diluting two samples at 52.7 ng/L and 211.4 ng/L. Of the 228 HCW samples, 59/228 (25.9 %) were positive, 169/228 (74.1 %) were negative. MAG-CLIA SARS-CoV-2 sAg median level (and interquartile range [IQR]) was 5.03 ng/L (<0.001-35.8 ng/L) for positive and <0.001 ng/L (<0.001 ng/L) for negative samples. MAG-CLIA AUC was 0.795 (95 % CI: 0.720-0.871). Using the best cut-off, 3.5 ng/L, sensitivity and specificity were 57.1 % (95 % CI: 42.2-71.2 %) and 97.0 % (95 % CI: 93.2-99.0 %), respectively. The agreement with the molecular assay was 88.1 % (Cohen's kappa 0.606 [SE=0.066, p<0.001]). CONCLUSIONS: The analytical performances of MAG-CLIA are satisfactory, also when values below LOD were tested. In saliva samples, although specificity was elevated, clinical performance was not comparable with that on nasopharyngeal swabs (NPS).


Assuntos
COVID-19 , Humanos , COVID-19/diagnóstico , SARS-CoV-2 , Testes Imunológicos , Antígenos Virais , Bioensaio , Sensibilidade e Especificidade
4.
Clin Chem Lab Med ; 61(9): 1652-1660, 2023 08 28.
Artigo em Inglês | MEDLINE | ID: mdl-36957995

RESUMO

OBJECTIVES: The SARS-CoV-2 immune response is mediated by both humoral and cellular immunity. In this study, SARS-CoV-2 specific cellular immunity was tested by a novel direct real-time PCR (dRT-PCR) assay, targeting mRNA of CXCL10, and compared with respect to an ELISA measuring interferon gamma (IFN-γ) release. METHODS: Whole blood (Li-He) and serum samples were collected from 92 healthcare workers (HCW), with three doses of homologous (Pfizer/BioNTech, n=74) or heterologous (Pfizer/BioNTech and Vaxzevria or Moderna, n=18) vaccinations. Li-He samples were incubated with SCV2 PANEL-1-T-ACTIVATION (Hyris srl, Lodi, Italy), or CoV-2 IGRA TUBE ELISA (Euroimmune, Lubeck, Germany). CXCL10 mRNA expression was analyzed by bCube/bApp (Hyris), while IFN-γ was evaluated by quant-T-Cell SARS-CoV-2 ELISA (Euroimmune). Anti-SARS-CoV-2 S-RBD IgG levels were measured in sera using a CLIA assay (Snibe, Shenzen, China). RESULTS: Imprecision of dRT-PCR assay was found to be satisfactory, and the two methods for measuring T cell immunity to SARS-CoV-2 peptides agreed in 82/87 (94.2%) of results. At qualitative dRT-PCR analyses, 81 subjects (93.2%) resulted as reactive to SARS-CoV-2 peptides, 3 (3.4%) were borderline and 3 were negative (3.4%). At univariate and multivariate analyses of quantitative dRT-PCR mRNA of CXCL10 and IFN-γ release results showed no difference between HCW with previous infection, homologous/heterologous vaccination, or demographical features. Anti-SARS-CoV-2 S-RBD IgG was associated with the previous infection and the time between the last vaccination or positivity. CONCLUSIONS: Direct RT-PCR appeared accurate for determining the presence or absence of immunoreactivity of SARS-CoV-2 specific T cells, especially when rapid analyses are required, such as for organ transplantation.


Assuntos
COVID-19 , Linfócitos T , Humanos , Vacinas contra COVID-19 , Reação em Cadeia da Polimerase em Tempo Real , COVID-19/diagnóstico , COVID-19/prevenção & controle , SARS-CoV-2 , Vacinação , Lítio , Imunoglobulina G , Anticorpos Antivirais , Teste para COVID-19
5.
Clin Chem Lab Med ; 61(2): 311-315, 2023 01 27.
Artigo em Inglês | MEDLINE | ID: mdl-36282964

RESUMO

OBEJCTIVES: Serosurveys can be used to monitor COVID-19 seroprevalence and conduct surveillance. Dried blood spot (DBS), used increasingly as a valuable sample to assay severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) antibodies (Ab), has several advantages, particularly in infants, due to the limited amount of blood required and its utility in testing a large number of samples in a limited time-frame. We evaluated SARS-CoV-2 IgG Ab prevalence in newborn DBS in the Trentino region of Italy, during the time period January 2020 - December 2021. METHODS: Anti-SARS-CoV-2 IgG levels were determined in DBS by means of Anti-SARS-CoV-2 QuantiVac IgG ELISA assay (Euroimmun, Lubeck, Germany). RESULTS: Analyses included 2,400 DBS from newborns (54% M, 46% F), samples being collected 2-3 days after birth. The first DBS that tested positive for anti-SARS-CoV-2 IgG antibodies was found in March 2020 and, up to May 2020, only 4 positive results were detected overall. Starting from June 2020, the positivity thresholds increased according to the epidemiological waves of the COVID-19 pandemic in Italy, with a robust increment in the winters of 2020 and 2021. The percentage of positive DBS rose from 0 to 6% to 10-47%, in 2020 and 2021, respectively. CONCLUSIONS: This study demonstrates DBS is a suitable tool for both epidemiological purposes and surveillance in the SARS-CoV-2 pandemic, particularly in newborns and pregnant women, saving blood waste and sparing patients any discomfort.


Assuntos
COVID-19 , Pandemias , Gravidez , Humanos , Recém-Nascido , Feminino , Estudos Soroepidemiológicos , SARS-CoV-2 , COVID-19/diagnóstico , COVID-19/epidemiologia , Anticorpos Antivirais , Imunoglobulina G
6.
Clin Chem Lab Med ; 61(2): 323-331, 2023 01 27.
Artigo em Inglês | MEDLINE | ID: mdl-36282616

RESUMO

OBJECTIVES: The rapid, accurate and safe detection of SARS-CoV-2 is the key to improving surveillance and infection containment. The aim of the present study was to ascertain whether, after heat/chemical inactivation, SARS-CoV-2 N antigen chemiluminescence (CLEIA) assay in saliva remains a valid alternative to molecular testing. METHODS: In 2022, 139 COVID-19 inpatients and 467 healthcare workers were enrolled. In 606 self-collected saliva samples (Salivette), SARS-CoV-2 was detected by molecular (TaqPath rRT-PCR) and chemiluminescent Ag assays (Lumipulse G). The effect of sample pre-treatment (extraction solution-ES or heating) on antigen recovery was verified. RESULTS: Salivary SARS-CoV-2 antigen assay was highly accurate (AUC=0.959, 95% CI: 0.943-0.974), with 90% sensitivity and 92% specificity. Of the 254 antigen positive samples, 29 were false positives. We demonstrated that heterophilic antibodies could be a cause of false positive results. A significant antigen concentration decrease was observed after ES treatment (p=0.0026), with misclassification of 43 samples. Heat had a minimal impact, after treatment the correct classification of cases was maintained. CONCLUSIONS: CLEIA SARS-CoV-2 salivary antigen provides accurate, timely and high-throughput results that remain accurate also after heat inactivation, thus ensuring a safer work environment. This supports the use of salivary antigen detection by CLEIA in surveillance programs.


Assuntos
COVID-19 , SARS-CoV-2 , Humanos , COVID-19/diagnóstico , Teste para COVID-19 , Saliva , Sensibilidade e Especificidade
7.
Clin Chem Lab Med ; 61(10): 1802-1807, 2023 09 26.
Artigo em Inglês | MEDLINE | ID: mdl-37114858

RESUMO

OBJECTIVES: Antibodies against glutamic acid decarboxylase isoform 65 (GAD-Ab) have been found in different severe neurological conditions associated with altered synthesis of γ-aminobutyric acid (GABA). Serum GAD-Ab can be found in up to 90 % of patients with type 1 diabetes mellitus (T1DM), mostly at relatively low concentrations, while high concentrations of GAD-ab are thought to be more frequently associate to a neurological condition, with levels 100-folds higher than those found in T1DM. Although CSF testing is recommended when suspecting a GAD-associated neurological syndrome, no commercial immunoassay is validated for this use and no cut-off is internationally recognized to support the diagnosis. METHODS: In this study we validated CSF testing of GAD-Ab on an automated chemiluminescence (CLIA) immunoassay that had previously shown good agreement with ELISA on serum. RESULTS: We tested 43 CSF from patients with typical GAD-associated neurological disorders and patients with other neurological conditions, identifying a clinical cut-off of 18 kIU/L that discriminated GAD-disease with an area under the curve (AUC) of 0.921. CLIA showed good analytical performances on repeatability and recovery tests in CSF and confirmed an excellent agreement with ELISA. CONCLUSIONS: GAD-Ab associated neurological disorders are rare but CSF testing for GAD-Ab is a common request for neurologists when suspecting an insidious autoimmune central nervous system disease. CLIA platforms are expected to be increasingly adopted in clinical laboratories due to their flexibility and reliability, therefore studies on decisional levels should be implemented for improving the interpretation and utilization of laboratory data.


Assuntos
Diabetes Mellitus Tipo 1 , Doenças do Sistema Nervoso , Humanos , Autoanticorpos , Síndrome , Diabetes Mellitus Tipo 1/diagnóstico , Luminescência , Reprodutibilidade dos Testes , Doenças do Sistema Nervoso/diagnóstico , Glutamato Descarboxilase
8.
BMC Med ; 20(1): 96, 2022 02 23.
Artigo em Inglês | MEDLINE | ID: mdl-35197073

RESUMO

BACKGROUND: The active surveillance of students is proposed as an effective strategy to contain SARS-CoV-2 spread and prevent schools' closure. Saliva for molecular testing is as sensitive as naso-pharyngeal swab (NPS), self-collected and well accepted by participants. This prospective study aimed to verify whether the active surveillance of the Padua University employees by molecular testing of self-collected saliva is an effective and affordable strategy for limiting SARS-CoV-2 spread. METHODS: A surveillance program based on self-collection of saliva every 2 weeks (October 2020-June 2021) was conducted. Among 8183 employees of the Padua University, a total of 6284 subjects voluntarily took part in the program. Eight collection points guaranteed the daily distribution and collection of barcoded salivary collection devices, which were delivered to the laboratory by a transport service for molecular testing. Quarantine of positive cases and contact tracing were promptly activated. RESULTS: Among 6284 subjects, 206 individuals were SARS-CoV-2 positive (99 by salivary testing; 107 by NPS performed for contact tracing or symptoms). The cumulative SARS-CoV-2 incidence in this cohort was 3.1%, significantly lower than that of employees not in surveillance (8.0%), in Padua (7.1%) and in the Veneto region (7.2%). Employees with positive saliva results were asymptomatic or had mild symptoms. The levels of serum antibodies after 3 months from the infection were correlated with age and Ct values, being higher in older subjects with greater viral loads. CONCLUSIONS: Salivary-based surveillance with contact tracing effectively allowed to limit SARS-CoV-2 contagion, also in a population with a high incidence.


Assuntos
COVID-19 , SARS-CoV-2 , Idoso , Humanos , Pandemias , Estudos Prospectivos , Saliva
9.
Clin Endocrinol (Oxf) ; 97(3): 331-338, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-34724236

RESUMO

OBJECTIVE: Alemtuzumab-induced autoimmune thyroid events (AIATEs) are the most common adverse effects observed in relapsing-remitting multiple sclerosis (RRMS) patients. This study aims to explore the clinical and biochemical characteristics of such AIATEs, and to examine the risk factors for their occurrence, particularly for the worst clinical phenotype of fluctuating Graves' disease (GD). DESIGN, PATIENTS, MEASUREMENTS: We retrospectively analysed a real-life single-centre consecutive series of 57 RRMS patients treated with alemtuzumab whose clinical and biochemical parameters were collected before starting the treatment and then monthly during their follow-up. RESULTS: AIATEs developed in 39% of patients a mean 17 months ± 11 after the first cycle of alemtuzumab. The most common AIATEs were GD (64%), followed by Hashimoto's thyroiditis with hypothyroidism (23%), TSH-receptor-antibody (TRAb)-positive hypothyroidism (9%), and silent thyroiditis (4%). GD showed a fluctuating course in 57% of cases. Baseline positivity for anti-thyroperoxidase antibodies, and higher absolute titers of anti-thyroglobulin and anti-thyroperoxidase antibodies correlated significantly with the risk of developing AIATEs, but TRAb positivity did not. Higher TRAb titers at the time of GD being diagnosed correlated strongly with a greater risk of the fluctuating GD phenotype. On ROC curve analysis, we found that a cut-off of 7.3 IU/L could be used to predict the risk of developing a fluctuating GD, with a positive predictive value of 100%. CONCLUSIONS: TRAb levels measured with commercial automatic methods at the time of a patient being diagnosed with alemtuzumab-induced GD emerged as a novel biomarker for predicting a fluctuating disease phenotype, with an influence on subsequent therapeutic decisions and patients' follow-up.


Assuntos
Doença de Graves , Hipotireoidismo , Esclerose Múltipla Recidivante-Remitente , Esclerose Múltipla , Tireoidite , Alemtuzumab/efeitos adversos , Doença de Graves/diagnóstico , Humanos , Hipotireoidismo/induzido quimicamente , Esclerose Múltipla/induzido quimicamente , Esclerose Múltipla/tratamento farmacológico , Esclerose Múltipla Recidivante-Remitente/induzido quimicamente , Esclerose Múltipla Recidivante-Remitente/tratamento farmacológico , Estudos Retrospectivos
10.
Clin Chem Lab Med ; 60(5): 766-770, 2022 04 26.
Artigo em Inglês | MEDLINE | ID: mdl-35041302

RESUMO

OBJECTIVES: The reliable identification of individuals with SARS-CoV-2 infection is the cornerstone for containing viral spread. Rapid molecular point-of-care testing (POCT) of saliva might reduce analysis time, thus increasing the efficacy of contact tracing. In this study, a new POCT RT-PCR assay for the detection of SARS-CoV-2 RNA in saliva was evaluated and compared with an already validated CE-IVD method. METHODS: An evaluation was made of 160 left-over salivary samples (27 frozen, kept at -80 °C and 133 fresh), collected using Salivette (Sarstedt, Germany). Samples were analyzed by TaqPath COVID-19 CE-IVD RT-PCR kit, QuantStudio5 Real-Time (Applied Biosystems, USA) (TaqPath) and bKIT Virus Finder COVID-19 Saliva (Hyris Global Diagnostics, Italy). Performances of three- and fivefold pooling strategies were also evaluated. Blood assay interference in saliva was also tested with Hyris. RESULTS: On using TaqPath, SARS-CoV-2 positivity was detected in 35 samples. Another 10 positive samples were artificially-generated by blind mixing of positive with negative samples. Hyris positive and negative percentages of agreement were 97.6 (95% CI: 87.2-99.9%) and 100 (95% CI: 97.0-100%), respectively. Seventeen positive pools, evaluated for threefold strategy, were all correctly determined by both systems. For the 5-pool strategy, 94.7% (18/19) of samples resulted positive with the Hyris system, and 100% with TaqPath. The presence of 1% of blood (v/v) in saliva did not interfere with the accuracy of Hyris assay. CONCLUSIONS: The sensitivity and specificity of the bKIT Virus Finder COVID-19 Saliva were optimal with respect to TaqPath. In view of the safe and straightforward pre-analytical procedure involved, and the small size of the Hyris bCube, the Hyris system can be used for POCT.


Assuntos
COVID-19 , SARS-CoV-2 , COVID-19/diagnóstico , Humanos , Testes Imediatos , RNA Viral/análise , RNA Viral/genética , SARS-CoV-2/genética , Saliva/química , Sensibilidade e Especificidade
11.
Clin Chem Lab Med ; 60(7): 1110-1115, 2022 06 27.
Artigo em Inglês | MEDLINE | ID: mdl-35473824

RESUMO

OBJECTIVES: The waning of humoral immunity after COVID-19 vaccine booster (third dose) has not yet been fully evaluated. This study updates data on anti-SARS-CoV-2 spike protein receptor binding domain (S-RBD) binding antibodies (bAb) and neutralizing antibodies (NAb) levels in individuals with homologous vaccination 3-4 months after receiving the booster dose. METHODS: Fifty-five healthcare workers (HCW) from Padova University-Hospital were asked to collect serum samples for determining antibodies (Ab) at 12 (t12) and 28 (t28) days, at 6 months (t6m) after their first Comirnaty/BNT162b2 inoculation, and 3-4 months after receiving the 3rd homologous booster dose. HCW were monitored weekly for SARS-CoV-2 infection. Ab titers were measured by two chemiluminescent immunoassays, one targeting the S-RBD immunoglobulin G (IgG), and one surrogate viral neutralization test (sVNT), measuring NAb. RESULTS: Twenty of the HCW had natural COVID-19 infection (COVID+) at different times, before either the first or the second vaccination. Median S-RBD IgG and NAb levels and their interquartile ranges 3-4 months after the 3rd dose were 1,076 (529-3,409) kBAU/L and 15.8 (11.3-38.3) mg/L, respectively, for COVID-, and 1,373 (700-1,373) kBAU/L and 21 (12.8-53.9) mg/L, respectively, for COVID+. At multivariate regression analyses, with age and gender included as covariates, S-RBD IgG bAb and sVNT NAb levels were closely associated with the time interval between serological determination and the 3rd vaccine dose (log10 ßcoeff=-0.013, p=0.012 and log10 ßcoeff=-0.010, p=0.025) for COVID+, whereas no such association was found in COVID- individuals. CONCLUSIONS: The third booster dose increases anti-SARS-CoV-2 Ab levels, elevated levels persisting for up to 3-4 months. Waning of Ab levels appears to be less pronounced for COVID+ individuals.


Assuntos
COVID-19 , SARS-CoV-2 , Anticorpos Neutralizantes , Anticorpos Antivirais , Vacina BNT162 , Vacinas contra COVID-19 , Estudos de Coortes , Pessoal de Saúde , Humanos , Imunização Secundária , Imunoglobulina G
12.
Clin Chem Lab Med ; 60(3): 456-463, 2022 02 23.
Artigo em Inglês | MEDLINE | ID: mdl-34911170

RESUMO

OBJECTIVES: mRNA vaccines, including Comirnaty (BNT162b2 mRNA, BioNTech-Pfizer), elicit high IgG and neutralizing antibody (NAb) responses after the second dose, but the progressive decrease in serum antibodies against SARS-CoV-2 following vaccination have raised questions concerning long-term immunity, decreased antibody levels being associated with breakthrough infections after vaccination, prompting the consideration of booster doses. METHODS: A total number of 189 Padua University-Hospital healthcare workers (HCW) who had received a second vaccine dose were asked to collect serum samples for determining Ab at 12 (t12) and 28 (t28) days, and 6 months (t6m) after their first Comirnaty/BNT162b2 inoculation. Ab titers were measured with plaque reduction neutralization test (PRNT), and three chemiluminescent immunoassays, targeting the receptor binding domain (RBD), the trimeric Spike protein (trimeric-S), and surrogate viral neutralization tests (sVNT). RESULTS: The median percentages (interquartile range) for decrease in antibodies values 6 months after the first dose were 86.8% (67.1-92.8%) for S-RBD IgG, 82% (58.6-89.3%) for trimeric-S, 70.4% (34.5-86.4%) for VNT-Nab, 75% (50-87.5%) for PRNT50 and 75% (50-93.7%) for PRNT90. At 6 months, neither PRNT titers nor VNT-Nab and S-RBD IgG bAb levels correlated with age (p=0.078) or gender (p=0.938), while they were correlated with previous infection (p<0.001). CONCLUSIONS: After 6 months, a method-independent reduction of around 90% in anti-SARS-CoV-2 antibodies was detected, while no significant differences were found between values of males and females aged between 24 and 65 years without compromised health status. Further efforts to improve analytical harmonization and standardization are needed.


Assuntos
Anticorpos Neutralizantes/sangue , Anticorpos Antivirais/sangue , Vacinas contra COVID-19/imunologia , COVID-19 , SARS-CoV-2 , Adulto , Idoso , Vacina BNT162 , COVID-19/prevenção & controle , Feminino , Humanos , Imunoensaio , Imunoglobulina G/sangue , Cinética , Masculino , Pessoa de Meia-Idade , Vacinação , Adulto Jovem
13.
Clin Chem Lab Med ; 59(8): 1444-1452, 2021 07 27.
Artigo em Inglês | MEDLINE | ID: mdl-33855843

RESUMO

OBJECTIVES: SARS-CoV-2 serology presents an important role in several aspects of COVID-19 pandemic. Immunoassays performances have to be accurately evaluated and correlated with neutralizing antibodies. We investigated the analytical and clinical performances of a SARS-CoV-2 RBD IgG assay, automated on a high throughput platform, and the correlation of the antibodies (Ab) levels with the plaque reduction neutralization (PRNT50) Ab titers. METHODS: A series of 546 samples were evaluated by SARS-CoV-2 RBD IgG assay (Snibe diagnostics), including 171 negative and 168 positive SARS-CoV-2 subjects and a further group of 207 subjects of the COVID-19 family clusters follow-up cohort. RESULTS: Assay imprecision ranged from 3.98 to 12.18% being satisfactory at low and medium levels; linearity was excellent in all the measurement range. Considering specimens collected after 14 days post symptoms onset, overall sensitivity and specificity were 99.0 and 92.5%, respectively. A total of 281 leftover samples results of the PRNT50 test were available. An elevated correlation was obtained between the SARS-CoV-2 RBD IgG assay and the PRNT50 titer at univariate (ρ=0.689) and multivariate (ρ=0.712) analyses. CONCLUSIONS: SARS-CoV-2 S-RBD IgG assay shows satisfactory analytical and clinical performances, and a strong correlation with sera neutralizing activity.


Assuntos
Anticorpos Neutralizantes/imunologia , Imunoglobulina G/imunologia , Testes de Neutralização/métodos , SARS-CoV-2/metabolismo , Glicoproteína da Espícula de Coronavírus/imunologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Anticorpos Neutralizantes/sangue , Anticorpos Antivirais/sangue , COVID-19/patologia , COVID-19/virologia , Criança , Feminino , Humanos , Imunoensaio/métodos , Imunoglobulina G/sangue , Masculino , Pessoa de Meia-Idade , Subunidades Proteicas/imunologia , SARS-CoV-2/isolamento & purificação , Índice de Gravidade de Doença , Adulto Jovem
14.
Clin Chem Lab Med ; 58(7): 1081-1088, 2020 06 25.
Artigo em Inglês | MEDLINE | ID: mdl-32301749

RESUMO

Background Coronavirus disease 2019, abbreviated to COVID-19, represents an emerging health threat worldwide as, after initial reports in China, it has continued to spread rapidly. The clinical spectrum of the disease varies from mild to severe acute respiratory distress syndrome (ARDS). Moreover, many patients can be asymptomatic, thus increasing the uncertainty of the diagnostic work-up. Laboratory tests play a pivotal role in the diagnosis and management of COVID-19, the current gold standard being real-time reverse transcription polymerase chain reaction (rRT-PCR) on respiratory tract specimens. However, the diagnostic accuracy of rRT-PCR depends on many pre-analytical and analytical variables. The measurement of specific COVID-19 antibodies (both IgG and IgM) should serve as an additional, non-invasive tool for disease detection and management. Methods The imprecision of the MAGLUMI™ 2000 Plus 2019-nCov IgM and IgG assays (Snibe, Shenzhen, China) was assessed by adopting the Clinical and Laboratory Standards Institute (CLSI) EP15-A3 protocol. Linearity of dilution and recovery was evaluated by means of mixes of high-level pools and low-level pools of serum samples. Immunoglobulin time kinetics were evaluated using a series of serum samples, repeatedly collected from COVID-19-positive patients at different times, from <5 days up to 26-30 days. Results Findings at the analytical validation of the assay carried out according to the CLSI EP15-A3 guideline demonstrated that imprecision and repeatability were acceptable (repeatability was <4% and <6% for IgM and IgG, respectively, whilst intermediate imprecision was <6%). In addition, results of dilution and recovery studies were satisfactory. The kinetics of COVID-19 antibodies confirmed previously reported findings, showing a rapid increase of both IgM and IgG after 6-7 days from the symptom onset. IgG had 100% sensitivity on day 12, whilst 88% was the higher positive rate achieved for IgM after the same time interval. Conclusions The findings of this study demonstrate the validity of the MAGLUMI 2000 Plus CLIA assay for the measurement of specific IgM and IgG in sera of COVID-19 patients, and for obtaining valuable data on the kinetics of both (IgM and IgG) COVID-19 antibodies. These data represent a pre-requisite for the appropriate utilization of specific antibodies for the diagnosis and management of COVID-19 patients.


Assuntos
Betacoronavirus/imunologia , Infecções por Coronavirus/imunologia , Técnicas Imunoenzimáticas/métodos , Pneumonia Viral/imunologia , Anticorpos Antivirais/sangue , COVID-19 , China , Técnicas de Laboratório Clínico/métodos , Humanos , Imunoglobulina G/sangue , Imunoglobulina G/imunologia , Imunoglobulina M/sangue , Imunoglobulina M/imunologia , Cinética , Medições Luminescentes/métodos , Pandemias , Reação em Cadeia da Polimerase em Tempo Real , SARS-CoV-2
15.
Scand J Clin Lab Invest ; 79(5): 293-297, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31070491

RESUMO

Background: The association between glycated albumin (GA) and glycaemic status has not been fully described in patients with advanced chronic kidney disease (CKD) in relation to anaemia. The aim of this study was to evaluate the relationship between GA and fasting plasma glucose (FPG) and HbA1c in patients with advanced CKD and to evaluate the influence of anaemia in such relationship. Materials and methods: Patients with CKD stage 4 or 5 were included in the study. eGFR was calculated by the CKD-EPI creatinine equation. Plasma GA was measured by an enzymatic method. Results: Eighty-one patients were included in the study, 46 (57%) were males; the mean age was 67 ± 14 years. HbA1c was correlated with Hb (r = 0.39; p = .0003), and no significant correlation was detected between plasma GA and serum albumin (p = .82). A significant association between FPG and GA (r2 = 0.41; p < .0001), and between FPG and HbA1c (r2 = 0.42; p < .0001) was detected in the whole study population. Patients with moderate/severe anaemia had lower HbA1c than patients with no anaemia, while both FPG and GA were comparable between the two groups. Multivariate regression analysis showed that GA was a significant predictor of FPG in patients with moderate/severe anaemia while HbA1c did not (r2 = 0.55; p < .0001 for the model). Conclusions: GA, alone or in combination with other biomarkers, can be considered for the evaluation of glycaemic status in patients with advanced CKD and severe anaemia.


Assuntos
Anemia/sangue , Insuficiência Renal Crônica/sangue , Albumina Sérica/metabolismo , Idoso , Anemia/complicações , Biomarcadores/sangue , Glicemia/análise , Jejum/sangue , Feminino , Hemoglobinas Glicadas/análise , Produtos Finais de Glicação Avançada , Humanos , Masculino , Análise de Regressão , Insuficiência Renal Crônica/complicações , Albumina Sérica Glicada
18.
Clin Chem Lab Med ; 56(1): 120-125, 2017 Nov 27.
Artigo em Inglês | MEDLINE | ID: mdl-28586301

RESUMO

BACKGROUND: Glycated Albumin (GA) has been proposed as a short-term indicator of glycemic homeostasis. The aim of this study is to describe the distribution of GA in a large sample of blood donors from Italy to evaluate whether demographic features, namely age and sex, could influence GA levels and define specific reference limits. METHODS: The study included 1334 Italian blood donors. GA was measured using an enzymatic method (quantILab Glycated Albumin, IL Werfen, Germany). The upper reference limit (URL) was calculated using the non-parametric percentile method. RESULTS: A modest, although significant, increase of GA was observed in relation to age (p<0.001), especially in males, where the differences were more pronounced (p<0.001 in males, p=0.003 in females). Slight differences were documented based on sex (12% [11.3-12.8] in males; 12.2% [11.4-13.1] in females; p=0.01). After excluding individuals with fasting plasma glucose ≥7 mmol/L, the calculated GA URL was 14.5% (95% CI: 14.3-14.7). Subjects with GA>14.5% presented a mean age of 48.4±12.2 years, 66.7% were males and the mean glucose was 6.88±2.5 mmol/L. CONCLUSIONS: GA in Caucasians shows a similar increasing trend at older ages documented in other ethnicities. The definition of the URL in this population could be useful for both clinical studies, which will clarify the role of GA for diagnosing and monitoring diabetes, and will encourage the introduction of GA in clinical practice.


Assuntos
Doadores de Sangue , Albumina Sérica/análise , Adolescente , Adulto , Idoso , Ensaios Enzimáticos/normas , Feminino , Produtos Finais de Glicação Avançada , Humanos , Itália , Masculino , Pessoa de Meia-Idade , Valores de Referência , Adulto Jovem , Albumina Sérica Glicada
19.
Acta Derm Venereol ; 97(7): 782-787, 2017 Jul 06.
Artigo em Inglês | MEDLINE | ID: mdl-28358411

RESUMO

Psoriasis is frequently associated with metabolic comorbidities. Advanced glycation end products (AGEs) are highly oxidant, biologically active compounds that accumulate in tissues in association with hyperglycaemia, hyperlipidaemia and oxidative stress. This is a cross-sectional case-control study involving 80 patients with mild/severe psoriasis and 80 controls matched for age, sex and body mass index (40 with severe eczema, 40 healthy individuals). Patients and healthy individuals with a smoking habit, diabetes, dyslipidaemia, hypercholesterolaemia, hypertension or who were under systemic treatment were excluded from the study. Skin AGEs were measured in normal-appearing skin by a standard fluorescence technique, and blood AGEs (total AGEs, pentosidine and AGEs receptor) by enzyme-linked immunosorbent assay. Levels of cutaneous AGEs (p < 0.04), serum AGEs (p < 0.03) and pentosidine (p <0.05) were higher in patients with severe psoriasis. Cutaneous AGEs correlated well with serum AGEs (r = 0.93, p < 0.0001) and with Psoriasis Area and Severity Index score (r = 0.91, p < 0.0001). Receptor levels were lower (p < 0.001) in severe psoriasis, and inversely correlated with disease severity (r = -0.71, p < 0.0002). Patients with severe psoriasis have accumulation of skin and serum AGEs, independent of associated metabolic disorders.


Assuntos
Produtos Finais de Glicação Avançada/sangue , Psoríase/metabolismo , Pele/química , Adulto , Biomarcadores/sangue , Estudos de Casos e Controles , Estudos Transversais , Ensaio de Imunoadsorção Enzimática , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Psoríase/sangue , Psoríase/diagnóstico , Índice de Gravidade de Doença , Pele/patologia , Espectrometria de Fluorescência , Regulação para Cima
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA