RESUMO
PURPOSE: To develop and validate a highly efficient motion compensated free-breathing isotropic resolution 3D whole-heart joint T1/T2 mapping sequence with anatomical water/fat imaging at 0.55 T. METHODS: The proposed sequence takes advantage of shorter T1 at 0.55 T to acquire three interleaved water/fat volumes with inversion-recovery preparation, no preparation, and T2 preparation, respectively. Image navigators were used to facilitate nonrigid motion-compensated image reconstruction. T1 and T2 maps were jointly calculated by a dictionary matching method. Validations were performed with simulation, phantom, and in vivo experiments on 10 healthy volunteers and 1 patient. The performance of the proposed sequence was compared with conventional 2D mapping sequences including modified Look-Locker inversion recovery and T2-prepared balanced steady-SSFP sequence. RESULTS: The proposed sequence has a good T1 and T2 encoding sensitivity in simulation, and excellent agreement with spin-echo reference T1 and T2 values was observed in a standardized T1/T2 phantom (R2 = 0.99). In vivo experiments provided good-quality co-registered 3D whole-heart T1 and T2 maps with 2-mm isotropic resolution in a short scan time of about 7 min. For healthy volunteers, left-ventricle T1 mean and SD measured by the proposed sequence were both comparable with those of modified Look-Locker inversion recovery (640 ± 35 vs. 630 ± 25 ms [p = 0.44] and 49.9 ± 9.3 vs. 54.4 ± 20.5 ms [p = 0.42]), whereas left-ventricle T2 mean and SD measured by the proposed sequence were both slightly lower than those of T2-prepared balanced SSFP (53.8 ± 5.5 vs. 58.6 ± 3.3 ms [p < 0.01] and 5.2 ± 0.9 vs. 6.1 ± 0.8 ms [p = 0.03]). Myocardial T1 and T2 in the patient measured by the proposed sequence were in good agreement with conventional 2D sequences and late gadolinium enhancement. CONCLUSION: The proposed sequence simultaneously acquires 3D whole-heart T1 and T2 mapping with anatomical water/fat imaging at 0.55 T in a fast and efficient 7-min scan. Further investigation in patients with cardiovascular disease is now warranted.
Assuntos
Tecido Adiposo , Imageamento Tridimensional , Imagens de Fantasmas , Humanos , Imageamento Tridimensional/métodos , Masculino , Tecido Adiposo/diagnóstico por imagem , Adulto , Coração/diagnóstico por imagem , Reprodutibilidade dos Testes , Algoritmos , Feminino , Imageamento por Ressonância Magnética/métodos , Respiração , Água Corporal/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Processamento de Imagem Assistida por Computador/métodos , Voluntários SaudáveisRESUMO
PURPOSE: To develop a framework for simultaneous three-dimensional (3D) mapping of T 1 $$ {\mathrm{T}}_1 $$ , T 2 $$ {\mathrm{T}}_2 $$ , and fat signal fraction in the liver at 0.55 T. METHODS: The proposed sequence acquires four interleaved 3D volumes with a two-echo Dixon readout. T 1 $$ {\mathrm{T}}_1 $$ and T 2 $$ {\mathrm{T}}_2 $$ are encoded into each volume via preparation modules, and dictionary matching allows simultaneous estimation of T 1 $$ {\mathrm{T}}_1 $$ , T 2 $$ {\mathrm{T}}_2 $$ , and M 0 $$ {M}_0 $$ for water and fat separately. 2D image navigators permit respiratory binning, and motion fields from nonrigid registration between bins are used in a nonrigid respiratory-motion-corrected reconstruction, enabling 100% scan efficiency from a free-breathing acquisition. The integrated nature of the framework ensures the resulting maps are always co-registered. RESULTS: T 1 $$ {\mathrm{T}}_1 $$ , T 2 $$ {\mathrm{T}}_2 $$ , and fat-signal-fraction measurements in phantoms correlated strongly (adjusted r 2 > 0 . 98 $$ {r}^2>0.98 $$ ) with reference measurements. Mean liver tissue parameter values in 10 healthy volunteers were 427 ± 22 $$ 427\pm 22 $$ , 47 . 7 ± 3 . 3 ms $$ 47.7\pm 3.3\;\mathrm{ms} $$ , and 7 ± 2 % $$ 7\pm 2\% $$ for T 1 $$ {\mathrm{T}}_1 $$ , T 2 $$ {\mathrm{T}}_2 $$ , and fat signal fraction, giving biases of 71 $$ 71 $$ , - 30 . 0 ms $$ -30.0\;\mathrm{ms} $$ , and - 5 $$ -5 $$ percentage points, respectively, when compared to conventional methods. CONCLUSION: A novel sequence for comprehensive characterization of liver tissue at 0.55 T was developed. The sequence provides co-registered 3D T 1 $$ {\mathrm{T}}_1 $$ , T 2 $$ {\mathrm{T}}_2 $$ , and fat-signal-fraction maps with full coverage of the liver, from a single nine-and-a-half-minute free-breathing scan. Further development is needed to achieve accurate proton-density fat fraction (PDFF) estimation in vivo.
Assuntos
Tecido Adiposo , Algoritmos , Imageamento Tridimensional , Fígado , Imageamento por Ressonância Magnética , Humanos , Fígado/diagnóstico por imagem , Imageamento Tridimensional/métodos , Tecido Adiposo/diagnóstico por imagem , Imageamento por Ressonância Magnética/economia , Imageamento por Ressonância Magnética/métodos , Movimento (Física) , Imagens de Fantasmas , Respiração , Reprodutibilidade dos Testes , Processamento de Imagem Assistida por Computador/métodos , Masculino , Adulto , Interpretação de Imagem Assistida por Computador/métodosRESUMO
PURPOSE: To develop and evaluate a highly efficient free-breathing and contrast-agent-free three-dimensional (3D) whole-heart Cardiac Magnetic Resonance Angiography (CMRA) sequence at 0.55T. METHODS: Free-breathing whole-heart CMRA has been previously proposed at 1.5 and 3T. Direct application of this sequence to 0.55T is not possible due to changes in the magnetic properties of the tissues. To enable free-breathing CMRA at 0.55T, pulse sequence design and acquisition parameters of a previously proposed whole-heart CMRA framework are optimized via Bloch simulations. Image navigators (iNAVs) are used to enable nonrigid respiratory motion-correction and 100% respiratory scan efficiency. Patch-based low-rank denoising is employed to accelerate the scan and account for the reduced signal-to-noise ratio at 0.55T. The proposed approach was evaluated on 11 healthy subjects. Image quality was assessed by a clinical expert (1: poor to 5: excellent) for all intrapericardiac structures. Quantitative evaluation was performed by assessing the vessel sharpness of the proximal right coronary artery (RCA). RESULTS: Optimization resulted in an imaging flip angle of 11 0 ∘ $$ 11{0}^{\circ } $$ , fat saturation flip angle of 18 0 ∘ $$ 18{0}^{\circ } $$ , and six k-space lines for iNAV encoding. The relevant cardiac structures and main coronary arteries were visible in all subjects, with excellent image quality (mean 4 . 9 / 5 . 0 $$ 4.9/5.0 $$ ) and minimal artifacts (mean 4 . 9 / 5 . 0 $$ 4.9/5.0 $$ ), with RCA vessel sharpness ( 50 . 3 % ± 9 . 8 % $$ 50.3\%\pm 9.8\% $$ ) comparable to previous studies at 1.5T. CONCLUSION: The proposed approach enables 3D whole-heart CMRA at 0.55T in a 6-min scan ( 5 . 9 ± 0 . 7 min $$ 5.9\pm 0.7\;\min $$ ), providing excellent image quality, minimal artifacts, and comparable vessel sharpness to previous 1.5T studies. Future work will include the evaluation of the proposed approach in patients with cardiovascular disease.
RESUMO
OBJECTIVE: This paper aims to demonstrate the feasibility of coupling electrical impedance tomography (EIT) with models of lung function in order to recover parameters and inform mechanical ventilation control. METHODS: A compartmental ordinary differential equation model of lung function is coupled to simulations of EIT, assuming accurate modeling and movement tracking, to generate time series values of bulk conductivity. These values are differentiated and normalized against the total air volume flux to recover regional volumes and flows. These ventilation distributions are used to recover regional resistance and elastance properties of the lung. Linear control theory is used to demonstrate how these parameters may be used to generate a patient-specific pressure mode control. RESULTS: Ventilation distributions are shown to be recoverable, with Euclidean norm errors in air flow below 9% and volume below 3%. The parameters are also shown to be recoverable, although errors are higher for resistance values than elastance. The control constructed is shown to have minimal seminorm resulting in bounded magnitudes and minimal gradients. CONCLUSION: The recovery of regional ventilation distributions and lung parameters is feasible with the use of EIT. These parameters may then be used in model based control schemes to provide patient-specific care. SIGNIFICANCE: For pulmonary-intensive-care patients mechanical ventilation is a life saving intervention, requiring careful calibration of pressure settings. Both magnitudes and gradients of pressure can contribute to ventilator induced lung injury. Retrieving regional lung parameters allows the design of patient-specific ventilator controls to reduce injury.