1.
J Environ Monit ; 14(2): 429-39, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22027817

RESUMO

During periods of two weeks in February and June 2010 the performance of portable air treatment units (PATUs) was evaluated in a primary school classroom using indicators of indoor air quality. Air samples were collected in an undisturbed setting on weekend days and in an occupied setting during teaching hours. In the first week PATUs were turned off and in the second week they were turned on. On weekend days PATUs reduced indoor levels of PM-10 by 87% in February and by 70% in June compared to weekend days when PATUs were turned off. On schooldays, indoor PM-10 was increased by 6% in February and reduced by 42% in June. For PM-2.5 reductions on weekend days were 89% in February and 80% in June. On school days PM-2.5 was increased by 15% in February and reduced by 83% in June. Turning on the PATUs reduced total VOC by 80% on weekend days and by 57% on school days (but not in June). No influence on formaldehyde, NO(2), O(3) and molds was observed. PATUs appeared to be less effective in removal of air pollutants when used in an occupied classroom compared to an unoccupied setting. Our study suggests that such devices should be tested in real-life settings to evaluate their influence on indoor air quality.


Assuntos
Poluentes Atmosféricos/análise , Poluição do Ar em Ambientes Fechados/análise , Filtração/instrumentação , Exposição por Inalação/análise , Microbiologia do Ar/normas , Poluentes Atmosféricos/normas , Poluição do Ar em Ambientes Fechados/prevenção & controle , Poluição do Ar em Ambientes Fechados/estatística & dados numéricos , Criança , Monitoramento Ambiental , Formaldeído/análise , Formaldeído/normas , Fungos , Nível de Saúde , Humanos , Exposição por Inalação/estatística & dados numéricos , Dióxido de Nitrogênio/análise , Dióxido de Nitrogênio/normas , Ozônio/análise , Ozônio/normas , Tamanho da Partícula , Material Particulado/análise , Material Particulado/normas , Instituições Acadêmicas , Compostos Orgânicos Voláteis/análise , Compostos Orgânicos Voláteis/normas
2.
J Occup Med Toxicol ; 12: 33, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29234454

RESUMO

BACKGROUND: In most reported cases of lung trauma with water proofing products, volatile organic compounds (VOC) have a prominent role. Here we report on a case involving ten workers exposed to a sprayed product containing nanoparticles in a water solution with only a few percent VOC. CASE PRESENTATION: Ten workers suffered from respiratory symptoms following spray impregnation of hardwood furniture using a waterproofing product that contained positively charged fluorinated acrylate copolymer solid cores with a median diameter of 70 nm (1.3 w%) in aqueous suspension with 3.3 w% VOC and 0.3 w% quaternary ammonium. The worker who applied one liter of the product in a wood workshop, using an air mix spray gun, did not report any health complaints. Another worker, who entered the workshop 3 h later and had rolled and smoked two cigarettes, was hospitalized with severe chemical pneumonitis. A chest X-ray (CXR) showed bilateral infiltrative impairment in the lower lobe regions. On the next day a second CXR showed increased patchiness marking in all fields. A high-resolution Computer Tomography (CT)-scan demonstrated extensive bilateral areas of ground-glass opacities predominantly in the lower regions of the upper lobes, the right middle lobe and the apical regions of the lower lobes, compatible with severe chemical pneumonitis. On the following morning, nine workers in an adjacent workplace in the same building, experienced dry cough, chest tightness and substernal pain upon physical exercise. Reconstruction of the spray application in a climate chamber confirmed trimethyl silanol, glycol ethers and fluoroalkenes in the gas phase. Immediately after the spray application, aerosols were observed at a maximum concentration of 6.3 × 104 cm-3. Mass concentrations were 0.095 and 10 mg/m3 in the size ranges 5.6-560 nm and 0.22-30 µm, respectively, decreasing to less than 10 µg/m3 in both size ranges after 15 h. CONCLUSION: The hospitalized worker had smoked cigarettes contaminated with fluoropolymers which is a plausible explanation for the lung trauma. Respiratory symptoms in the nine workers may be caused by inhalation of particles that became airborne by resuspension from surfaces when workers entered the adjacent workplace the next day. A contribution from VOC appears less likely because measurements and modelling showed that concentrations in the mg/m3 range could have occurred only if the building was assumed to be completely airtight.