Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Base de dados
Tipo de documento
Ano de publicação
Intervalo de ano de publicação
1.
Ann Chir Plast Esthet ; 68(3): 204-212, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36216645

RESUMO

INTRODUCTION: Percutaneous screw fixation has recently gained popularity as an alternative to conservative treatment to avoid prolonged immobilization. The placement of a screw in the central axis of the scaphoid has been shown to be biomechanically superior to its eccentricity. Still, it poses difficulties in performing percutaneous screw fixation via both palmar and dorsal approaches. OBJECTIVE: We describe a palmar percutaneous screwing of corporal fractures of the scaphoid by a simple palmar transtrapezial approach allowing an optimal centering of the screw. METHOD: We selected patients operated on by the same surgeon using the palmar transtrapezial approach between January 2015 and January 2019 based on the coding used for these fractures and the operative reports. In addition, pre- and postoperative data were collected from the patient's computer and paper records and by telephone contact with the patients. RESULTS: Thirty-three patients were included. Percutaneous screw fixation of the scaphoid was performed under locoregional anesthesia in the operating room with one arm in the supine position on the arm table. No hyper-extension of the wrist was performed. The Kirchner guidewire passed through the anterior horn of the trapezium and then into the trapezium-scaphoid joint. A screw replaced it after satisfactory centering in the axis of the scaphoid. Management took place on average within 12 days after the trauma. 75.8% were A2 fractures, according to Herbert's classification. The average operating time was 16.63minutes, and in 91% of the cases, the patient was hospitalized for one day. The variation of the scapholunate angle on the preoperative profile radiographs with the angle defined by the axis of the scaphoid screw and the lunate postoperatively was on average 2.94°. One patient presented nonunion, and four showed an undersized screw with a screw overhang requiring revision surgery. CONCLUSION: The transtrapezial approach to fixation of acute scaphoid fractures facilitates precise percutaneous screw placement in the central axis of the scaphoid. A study of long-term complications, including the degenerative impact on the scaphotrapezial joint, is needed to assess the safety of passage through the anterior horn of the trapezium.


Assuntos
Fraturas Ósseas , Osso Escafoide , Humanos , Fraturas Ósseas/cirurgia , Fixação Interna de Fraturas , Osso Escafoide/lesões , Osso Escafoide/cirurgia , Estudos Retrospectivos , Parafusos Ósseos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA