Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Assunto principal
Tipo de documento
Ano de publicação
Intervalo de ano de publicação
1.
Med Phys ; 23(1): 53-62, 1996 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-8700033

RESUMO

A miniature, battery operated 40 kV x-ray device has been developed for the interstitial treatment of small tumors ( < 3 cm diam) in humans. X rays are emitted from the tip of a 10 cm long, 3 mm diameter probe that is stereotactically inserted into the tumor. The beam, characterized by half-value layer (HVL), spectrum analysis, and isodose contours, behaves essentially as a point isotropic source with an effective energy of 20 keV at a depth of 10 mm in water. The absolute output from the device was measured using a parallel plate ionization chamber, modified with a platinum aperture. The dose rate in water determined from these chamber measurements was found to be nominally 150 cGy/min at a distance of 10 mm for a beam current of 40 microA and voltage of 40 kV. The dose in water falls off approximately as the third power of the distance. To date, 14 patients have been treated with this device in a phase I clinical trial.


Assuntos
Radiocirurgia/instrumentação , Fenômenos Biofísicos , Biofísica , Neoplasias Encefálicas/radioterapia , Desenho de Equipamento , Humanos , Miniaturização , Controle de Qualidade , Radiometria/instrumentação , Radiocirurgia/normas , Radiocirurgia/estatística & dados numéricos , Dosagem Radioterapêutica , Padrões de Referência , Tecnologia Radiológica , Dosimetria Termoluminescente/instrumentação
2.
Med Phys ; 23(1): 45-52, 1996 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-8700032

RESUMO

A device that generates low-energy x rays at the tip of a needle-like probe was developed for stereotactic interstitial radiosurgery. Electrons from a small thermionic gun are accelerated to a final energy of up to 40 keV and directed along a 3 mm outside diameter drift tube to a thin Au target, where the beam size is approximately 0.3 mm. All high-voltage electronics are in the probe housing, connected by low-voltage cable to a battery-operated control box. X-ray output, which is nearly isotropic, consists of a bremsstrahlung spectrum and several lines between 7 and 14 keV, with characteristic radiation contributing 15% of the total energy output. To date, 14 patients with metastatic brain tumors have been treated with this device.


Assuntos
Radiocirurgia/instrumentação , Fenômenos Biofísicos , Biofísica , Eletrônica Médica , Desenho de Equipamento , Humanos , Miniaturização , Tecnologia Radiológica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA