RESUMO
Uterosacral ligaments (USLs) provide structural support to the female pelvic floor, and a loss of USL structural integrity or biomechanical function may induce pelvic organ prolapse (POP). Alterations in extracellular matrix composition and organization dictate USL mechanical function. Changes in USL microstructure and corresponding mechanical properties, however, are not fully understood, nor is it understood how microstructure and mechanics change with onset and progression of POP. This is due, in part, as USL properties are primarily characterized along a single direction (uniaxial test), whereas the USL is loaded in multiple directions simultaneously within the body. Biaxial testing permits the acquisition of biomechanical data from two axes simultaneously, and thus simulates a more physiologic assessment compared to the traditional uniaxial testing. Therefore, the objective of this study was to quantify the biaxial biomechanical properties and histological composition of the USL in post-menopausal women with and without POP at various stages. Potential correlations between tissue microstructural composition and mechanical function were also examined. Tangential modulus was lower and peak stretch higher in POP III/IV compared to non-POP and POP I/II in the main in vivo loading direction; however, no significant differences in mechanical properties were observed in the perpendicular loading direction. Collagen content positively correlated to tangential modulus in the main in vivo loading direction (r = 0.5, p = 0.02) and negatively correlated with the peak stretch in both the main in vivo (r = -0.5, p = 0.02) and perpendicular loading directions (r = -0.3, p = 0.05). However, no statistically significant differences in USL composition were observed, which may be due to the small sample size and high variability of small sections of human tissues. These results provide first step towards understanding what microstructural and mechanical changes may occur in the USL with POP onset and progression. Such information may provide important future insights into the development of new surgical reconstruction techniques and graft materials for POP treatment.
Assuntos
Ligamentos/fisiopatologia , Prolapso de Órgão Pélvico/fisiopatologia , Pós-Menopausa , Útero/fisiopatologia , Idoso , Feminino , Humanos , Ligamentos/patologia , Pessoa de Meia-Idade , Diafragma da Pelve/patologia , Diafragma da Pelve/fisiopatologia , Prolapso de Órgão Pélvico/patologia , Útero/patologiaRESUMO
From a biomechanical perspective, female reproductive health is an understudied area of research. There is an incomplete understanding of the complex function and interaction between the cervix and uterus. This, in part, is due to the limited research into multiaxial biomechanical functions and geometry of these organs. Knowledge of the biomechanical function and interaction between these organs may elucidate etiologies of conditions such as preterm birth. Therefore, the objective of this study was to quantify the multiaxial biomechanical properties of the murine cervix and uterus using a biaxial testing set-up. To accomplish this, an inflation-extension testing protocol (nâ¯=â¯15) was leveraged to quantify biaxial biomechanical properties while preserving native matrix interactions and geometry. Ultrasound imaging and histology (nâ¯=â¯10) were performed to evaluate regional geometry and microstructure, respectively. Histological analysis identified a statistically significant greater collagen content and significantly smaller smooth muscle content in the cervix as compared to the uterus. No statistically significant differences in elastic fibers were identified. Analysis of bilinear fits revealed a significantly stiffer response from the circumferentially orientated ECM fibers compared to axially orientated fibers in both organs. Bilinear fits and a two-fiber family constitutive model showed that the cervix was significantly less distensible than the uterus. We submit that the regional biaxial information reported in this study aids in establishing an appropriate reference configuration for mathematical models of the uterine-cervical complex. Thus, may aid future work to elucidate the biomechanical mechanisms leading to cervical or uterine conditions.
Assuntos
Colo do Útero/fisiologia , Animais , Fenômenos Biomecânicos , Biofísica , Colo do Útero/anatomia & histologia , Colo do Útero/diagnóstico por imagem , Colágeno , Feminino , Camundongos , Músculo Liso , Ultrassonografia , ÚteroRESUMO
The aim of the present study was to evaluate the applicability of ultrasound imaging to quantitative assessment of human meniscus in vitro. Meniscus samples (n = 26) were harvested from 13 knee joints of non-arthritic human cadavers. Subsequently, three locations (anterior, center and posterior) from each meniscus were imaged with two ultrasound transducers (frequencies 9 and 40 MHz), and quantitative ultrasound parameters were determined. Furthermore, partial-least-squares regression analysis was applied for ultrasound signal to determine the relations between ultrasound scattering and meniscus integrity. Significant correlations between measured and predicted meniscus compositions and mechanical properties were obtained (R2 = 0.38-0.69, p < 0.05). The relationship between conventional ultrasound parameters and integrity of the meniscus was weaker. To conclude, ultrasound imaging exhibited a potential for evaluation of meniscus integrity. Higher ultrasound frequency combined with multivariate analysis of ultrasound backscattering was found to be the most sensitive for evaluation of meniscus integrity.
Assuntos
Articulação do Joelho/diagnóstico por imagem , Menisco/diagnóstico por imagem , Ultrassonografia/métodos , Adulto , Idoso , Cadáver , Cartilagem Articular/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Adulto JovemRESUMO
Biomechanical properties of human meniscus have been shown to be site-specific. However, it is not known which meniscus constituents at different depths and locations contribute to biomechanical properties obtained from indentation testing. Therefore, we investigated the composition and structure of human meniscus in a site- and depth-dependent manner and their relationships with tissue site-specific biomechanical properties. Elastic and poroelastic properties were analyzed from experimental stress-relaxation and sinusoidal indentation measurements with fibril reinforced poroelastic finite element modeling. Proteoglycan (PG) and collagen contents, as well as the collagen orientation angle, were determined as a function of tissue depth using microscopic and spectroscopic methods, and they were compared with biomechanical properties. For all the measurement sites (anterior, middle and posterior) of lateral and medial menisci (n=26), PG content and collagen orientation angle increased as a function of tissue depth while the collagen content had an initial sharp increase followed by a decrease across tissue depth. The highest values (p<0.05) of elastic parameters (equilibrium and instantaneous moduli) and strain-dependent biomechanical parameters (strain-dependent fibril network modulus and permeability) were observed in the anterior horn of the medial meniscus. This location had also higher (p<0.05) PG content in the deep meniscus, higher (p<0.05) collagen content in the entire tissue depth, and lower (p<0.05) collagen orientation angle at the superficial tissue, as compared to many other locations. On the other hand, in certain comparisons (such as anterior vs. middle sites of the medial meniscus) significantly higher (p<0.05) collagen content and lower orientation angle, without any difference in the PG content, were consistent with increased meniscus modulus and/or nonlinear permeability. This study suggests that nonlinear biomechanical properties of meniscus, caused by the collagen network and fluid, may be strongly influenced by tissue osmotic swelling from the deep meniscus caused by the increased PG content, leading to increased collagen fibril tension. These nonlinear biomechanical properties are suggested to be further amplified by higher collagen content at all tissue depths and superficial collagen fibril orientation. However, these structure-function relationships are suggested to be highly site-specific.
Assuntos
Colágeno/fisiologia , Meniscos Tibiais/fisiologia , Proteoglicanas/fisiologia , Fenômenos Biomecânicos , Humanos , Relação Estrutura-AtividadeRESUMO
This study investigates the capacity of optical spectroscopy in the visible (VIS) and near-infrared (NIR) spectral ranges for estimating the biomechanical properties of human meniscus. Seventy-two samples obtained from the anterior, central, and posterior locations of the medial and lateral menisci of 12 human cadaver joints were used. The samples were subjected to mechanical indentation, then traditional biomechanical parameters (equilibrium and dynamic moduli) were calculated. In addition, strain-dependent fibril network modulus and permeability strain-dependency coefficient were determined via finite-element modeling. Subsequently, absorption spectra were acquired from each location in the VIS (400 to 750 nm) and NIR (750 to 1100 nm) spectral ranges. Partial least squares regression, combined with spectral preprocessing and transformation, was then used to investigate the relationship between the biomechanical properties and spectral response. The NIR spectral region was observed to be optimal for model development (83.0%≤R2≤90.8%). The percentage error of the models are: Eeq (7.1%), Edyn (9.6%), Eϵ (8.4%), and Mk (8.9%). Thus, we conclude that optical spectroscopy in the NIR range is a potential method for rapid and nondestructive evaluation of human meniscus functional integrity and health in real time during arthroscopic surgery.