Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de documento
Ano de publicação
Intervalo de ano de publicação
1.
Ann Rheum Dis ; 73(7): 1388-92, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24665112

RESUMO

BACKGROUND: Positron emission tomography (PET) scan is emerging as a promising imaging technique to detect large-vessel inflammation in giant cell arteritis (GCA). However, the lack of a standardised definition of arteritis based on (18)fluorodeoxyglucose (FDG) uptake is an important limitation to the use of PET scan for diagnostic purposes. OBJECTIVE: To prospectively assess the intensity and distribution of FDG uptake at different vascular territories in patients with newly diagnosed GCA compared with controls. METHODS: 32 consecutive, biopsy-proven, GCA patients treated with glucocorticoids for ≤3 days were included. The control group consisted of 20 individuals, who underwent PET/CT for cancer staging. Maximal standardised uptake value (SUVm) was calculated at four aortic segments, supraaortic branches and iliac-femoral territory. Sensitivity and specificity was calculated by receiver-operator characteristic curves (ROC) analysis. RESULTS: Mean SUVm was significantly higher in patients than in controls in all vessels explored and correlated with acute-phase reactants and serum IL-6. Mean of the SUVm at all the vascular territories had an area under the curve (AUC) of 0.830, and a cut-off of 1.89 yielded a sensitivity of 80% and a specificity of 79% for GCA diagnosis. There were no significant differences in AUC among the vascular beds examined. CONCLUSIONS: FDG uptake by large vessels has a substantial sensitivity and specificity for GCA diagnosis.


Assuntos
Artérias/diagnóstico por imagem , Arterite de Células Gigantes/diagnóstico por imagem , Proteínas de Fase Aguda/imunologia , Idoso , Idoso de 80 Anos ou mais , Aorta/diagnóstico por imagem , Área Sob a Curva , Artérias/patologia , Artéria Axilar/diagnóstico por imagem , Biópsia , Artérias Carótidas/diagnóstico por imagem , Estudos de Casos e Controles , Feminino , Artéria Femoral/diagnóstico por imagem , Fluordesoxiglucose F18 , Arterite de Células Gigantes/imunologia , Arterite de Células Gigantes/patologia , Humanos , Artéria Ilíaca/diagnóstico por imagem , Interleucina-6/imunologia , Masculino , Pessoa de Meia-Idade , Imagem Multimodal , Tomografia por Emissão de Pósitrons , Estudos Prospectivos , Curva ROC , Compostos Radiofarmacêuticos , Sensibilidade e Especificidade , Artéria Subclávia/diagnóstico por imagem , Artérias Temporais/patologia , Tomografia Computadorizada por Raios X
3.
Clin Nucl Med ; 38(11): 878-81, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24089071

RESUMO

PURPOSE: The aim of the study was to determine if pinhole collimator-acquired images can improve the detection of hyperfunctioning parathyroid glands in patients with secondary hyperparathyroidism. METHODS: Forty-two patients being treated with cinacalcet for secondary hyperparathyroidism were studied prospectively. Patients were divided into 2 groups according to their levels of parathyroid hormone (PTH), the hormone that defines response to treatment: "responders" (PTH <300 pg/mL) and "nonresponders" (PTH ≥ 300 pg/mL). Double-phase scintigraphy using 888 MBq of (99m)Tc-MIBI was used to acquire early and late parallel-hole and pinhole collimator images. Neck ultrasonography was performed on all patients to identify intrathyroid nodules. All focal uptake in any of the acquired scintigraphic images was considered positive. RESULTS: The responder group included 24 patients, whereas 18 patients were considered as nonresponders. At least 1 parathyroid gland with (99m)Tc-MIBI uptake was detected in 33 of 42 patients, with a total of 50 parathyroid glands located. We found significant differences between the detection rates of late pinhole collimator and the late parallel-hole images (74% vs 48%, P = 0.0036). This detection rate was highest with late parallel-hole images in the nonresponder group (89%). CONCLUSIONS: The late pinhole collimator acquisition showed the highest detection rate of hyperfunctioning parathyroid glands using (99m)Tc-MIBI scintigraphy in secondary hyperparathyroidism patients treated with cinacalcet.


Assuntos
Hiperparatireoidismo Secundário/diagnóstico por imagem , Cintilografia/instrumentação , Tecnécio Tc 99m Sestamibi , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Glândulas Paratireoides/diagnóstico por imagem , Ultrassonografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA