Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 48
Filtrar
1.
Magn Reson Med ; 91(5): 1803-1821, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38115695

RESUMO

PURPOSE: K trans $$ {K}^{\mathrm{trans}} $$ has often been proposed as a quantitative imaging biomarker for diagnosis, prognosis, and treatment response assessment for various tumors. None of the many software tools for K trans $$ {K}^{\mathrm{trans}} $$ quantification are standardized. The ISMRM Open Science Initiative for Perfusion Imaging-Dynamic Contrast-Enhanced (OSIPI-DCE) challenge was designed to benchmark methods to better help the efforts to standardize K trans $$ {K}^{\mathrm{trans}} $$ measurement. METHODS: A framework was created to evaluate K trans $$ {K}^{\mathrm{trans}} $$ values produced by DCE-MRI analysis pipelines to enable benchmarking. The perfusion MRI community was invited to apply their pipelines for K trans $$ {K}^{\mathrm{trans}} $$ quantification in glioblastoma from clinical and synthetic patients. Submissions were required to include the entrants' K trans $$ {K}^{\mathrm{trans}} $$ values, the applied software, and a standard operating procedure. These were evaluated using the proposed OSIP I gold $$ \mathrm{OSIP}{\mathrm{I}}_{\mathrm{gold}} $$ score defined with accuracy, repeatability, and reproducibility components. RESULTS: Across the 10 received submissions, the OSIP I gold $$ \mathrm{OSIP}{\mathrm{I}}_{\mathrm{gold}} $$ score ranged from 28% to 78% with a 59% median. The accuracy, repeatability, and reproducibility scores ranged from 0.54 to 0.92, 0.64 to 0.86, and 0.65 to 1.00, respectively (0-1 = lowest-highest). Manual arterial input function selection markedly affected the reproducibility and showed greater variability in K trans $$ {K}^{\mathrm{trans}} $$ analysis than automated methods. Furthermore, provision of a detailed standard operating procedure was critical for higher reproducibility. CONCLUSIONS: This study reports results from the OSIPI-DCE challenge and highlights the high inter-software variability within K trans $$ {K}^{\mathrm{trans}} $$ estimation, providing a framework for ongoing benchmarking against the scores presented. Through this challenge, the participating teams were ranked based on the performance of their software tools in the particular setting of this challenge. In a real-world clinical setting, many of these tools may perform differently with different benchmarking methodology.


Assuntos
Meios de Contraste , Imageamento por Ressonância Magnética , Humanos , Reprodutibilidade dos Testes , Imageamento por Ressonância Magnética/métodos , Software , Algoritmos
2.
J Magn Reson Imaging ; 59(2): 563-574, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37191075

RESUMO

BACKGROUND: Patients with polyneuropathies typically have demyelination and/or axonal degeneration in peripheral nerves. Currently, there is a lack of imaging biomarkers to track the changes in these pathologies. PURPOSE: To develop and evaluate the reliability of a multiparametric quantitative magnetic resonance imaging (qMRI) method of peripheral nerves in the leg. STUDY TYPE: Prospective. SUBJECTS: Seventeen healthy volunteers (36.2 ± 13.8 years old, 9 males) with 10 of them scanned twice for test-retest. FIELD STRENGTH/SEQUENCE: 3 T, three-dimensional gradient echo and diffusion tensor imaging. ASSESSMENT: A qMRI protocol and processing pipeline was established for quantifying the following nerve parameters that are sensitive to myelin and axonal pathologies: magnetization transfer (MT) ratio (MTR), MT saturation index (MTsat), T2 *, T1 , proton density (PD), fractional anisotropy (FA), and mean/axial/radial diffusivities (MD, AD, and RD). The qMRI protocol also measures the volume of nerve fascicles (fVOL) and the fat fraction (FF) of muscles. STATISTICAL TESTS: The intersession reproducibility and inter-rater reliability of each qMRI parameter were assessed by Bland-Altman analysis and intraclass correlation coefficient (ICC). Pairwise Pearson correlation analyses were performed to investigate the intrinsic association between qMRI parameters. Distal-to-proximal variations were evaluated by paired t-tests with Bonferroni-Holm multiple comparison corrections. P < 0.05 was considered statistically significant. RESULTS: The MTR, MTsat, T2 *, T1 , PD, FA, AD, and fVOL of the sciatic and tibial nerves, and the FF of leg muscles, had an overall good-to-excellent test-retest agreement (ICC varying from 0.78 to 0.99). All the qMRI parameters had good-to-excellent inter-rater reliability (ICC > 0.80). The data demonstrated a pattern of distal-to-proximal changes of an increased nerve MTsat and FA, and a decreased nerve T1 , PD, MD, and RD, as well as a significantly increased muscle FF. DATA CONCLUSION: The proposed multiparametric qMRI method of the peripheral nerves is highly reproducible and provided healthy control data which will be used in developing monitoring biomarkers in patients with polyneuropathies. LEVEL OF EVIDENCE: 1 TECHNICAL EFFICACY: Stage 2.


Assuntos
Imagem de Tensor de Difusão , Polineuropatias , Masculino , Humanos , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Imagem de Tensor de Difusão/métodos , Reprodutibilidade dos Testes , Estudos Prospectivos , Perna (Membro)/diagnóstico por imagem , Nervos Periféricos/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Biomarcadores
3.
J Neurol Neurosurg Psychiatry ; 94(12): 1025-1039, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-36997315

RESUMO

Distal sensory polyneuropathy (DSP) is characterised by length-dependent, sensory-predominant symptoms and signs, including potentially disabling symmetric chronic pain, tingling and poor balance. Some patients also have or develop dysautonomia or motor involvement depending on whether large myelinated or small fibres are predominantly affected. Although highly prevalent, diagnosis and management can be challenging. While classic diabetes and toxic causes are well-recognised, there are increasingly diverse associations, including with dysimmune, rheumatological and neurodegenerative conditions. Approximately half of cases are initially considered idiopathic despite thorough evaluation, but often, the causes emerge later as new symptoms develop or testing advances, for instance with genetic approaches. Improving and standardising DSP metrics, as already accomplished for motor neuropathies, would permit in-clinic longitudinal tracking of natural history and treatment responses. Standardising phenotyping could advance research and facilitate trials of potential therapies, which lag so far. This review updates on recent advances and summarises current evidence for specific treatments.


Assuntos
Polineuropatias , Humanos , Polineuropatias/diagnóstico , Polineuropatias/terapia
4.
Neuroimage ; 203: 116190, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31525497

RESUMO

Cognitive impairment (CI) is a major manifestation of multiple sclerosis (MS) and is responsible for extensively hindering patient quality of life. Cortical gray matter (cGM) damage is a significant contributor to CI, but is poorly characterized by conventional MRI let alone with quantitative MRI, such as quantitative magnetization transfer (qMT). Here we employed high-resolution qMT at 7T via the selective inversion recovery (SIR) method, which provides tissue-specific indices of tissue macromolecular content, such as the pool size ratio (PSR) and the rate of MT exchange (kmf). These indices could represent expected demyelination that occurs in the presence of gray matter damage. We utilized selective inversion recovery (SIR) qMT which provides a low SAR estimate of macromolecular-bulk water interactions using a tailored, B1 and B0 robust inversion recovery (IR) sequence acquired at multiple inversion times (TI) at 7T and fit to a two-pool model of magnetization exchange. Using this sequence, we evaluated qMT indices across relapsing-remitting multiple sclerosis patients (N = 19) and healthy volunteers (N = 37) and derived related associations with neuropsychological measures of cognitive impairment. We found a significant reduction in kmf in cGM of MS patients (15.5%, p = 0.002), unique association with EDSS (ρ = -0.922, p = 0.0001), and strong correlation with cognitive performance (ρ = -0.602, p = 0.0082). Together these findings indicate that the rate of MT exchange (kmf) may be a significant biomarker of cGM damage relating to CI in MS.


Assuntos
Córtex Cerebral/diagnóstico por imagem , Disfunção Cognitiva/diagnóstico por imagem , Substância Cinzenta/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Esclerose Múltipla/diagnóstico por imagem , Adulto , Córtex Cerebral/patologia , Disfunção Cognitiva/etiologia , Disfunção Cognitiva/patologia , Feminino , Substância Cinzenta/patologia , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Esclerose Múltipla/complicações , Esclerose Múltipla/patologia , Esclerose Múltipla/psicologia , Adulto Jovem
6.
Magn Reson Med ; 80(5): 1824-1835, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-29573356

RESUMO

PURPOSE: To optimize a selective inversion recovery (SIR) sequence for macromolecular content mapping in the human brain at 3.0T. THEORY AND METHODS: SIR is a quantitative method for measuring magnetization transfer (qMT) that uses a low-power, on-resonance inversion pulse. This results in a biexponential recovery of free water signal that can be sampled at various inversion/predelay times (tI/ tD ) to estimate a subset of qMT parameters, including the macromolecular-to-free pool-size-ratio (PSR), the R1 of free water (R1f ), and the rate of MT exchange (kmf ). The adoption of SIR has been limited by long acquisition times (≈4 min/slice). Here, we use Cramér-Rao lower bound theory and data reduction strategies to select optimal tI /tD combinations to reduce imaging times. The schemes were experimentally validated in phantoms, and tested in healthy volunteers (N = 4) and a multiple sclerosis patient. RESULTS: Two optimal sampling schemes were determined: (i) a 5-point scheme (kmf estimated) and (ii) a 4-point scheme (kmf assumed). In phantoms, the 5/4-point schemes yielded parameter estimates with similar SNRs as our previous 16-point scheme, but with 4.1/6.1-fold shorter scan times. Pair-wise comparisons between schemes did not detect significant differences for any scheme/parameter. In humans, parameter values were consistent with published values, and similar levels of precision were obtained from all schemes. Furthermore, fixing kmf reduced the sensitivity of PSR to partial-volume averaging, yielding more consistent estimates throughout the brain. CONCLUSIONS: qMT parameters can be robustly estimated in ≤1 min/slice (without independent measures of ΔB0 , B1+, and T1 ) when optimized tI -tD combinations are selected.


Assuntos
Química Encefálica/fisiologia , Mapeamento Encefálico/métodos , Encéfalo/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Adulto , Algoritmos , Feminino , Humanos , Masculino , Bainha de Mielina/química , Imagens de Fantasmas
7.
Magn Reson Med ; 80(6): 2609-2617, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-29802641

RESUMO

PURPOSE: To test the ability of a novel pulse sequence applied in vivo at 3 Tesla to separate the contributions to the water signal from amide proton transfer (APT) and relayed nuclear Overhauser enhancement (rNOE) from background direct water saturation and semisolid magnetization transfer (MT). The lack of such signal source isolation has confounded conventional chemical exchange saturation transfer (CEST) imaging. METHODS: We quantified APT and rNOE signals using a chemical exchange rotation transfer (CERT) metric, MTRdouble . A range of duty cycles and average irradiation powers were applied, and results were compared with conventional CEST analyses using asymmetry (MTRasym ) and extrapolated magnetization transfer (EMR). RESULTS: Our results indicate that MTRdouble is more specific than MTRasym and, because it requires as few as 3 data points, is more rapid than methods requiring a complete Z-spectrum, such as EMR. In white matter, APT (1.5 ± 0.5%) and rNOE (2.1 ± 0.7%) were quantified by using MTRdouble with a 30% duty cycle and a 0.5-µT average power. In addition, our results suggest that MTRdouble is insensitive to B0 inhomogeneity, further magnifying its speed advantage over CEST metrics that require a separate B0 measurement. However, MTRdouble still has nontrivial sensitivity to B1 inhomogeneities. CONCLUSION: We demonstrated that MTRdouble is an alternative metric to evaluate APT and rNOE, which is fast, robust to B0 inhomogeneity, and easy to process.


Assuntos
Mapeamento Encefálico , Neoplasias Encefálicas/diagnóstico por imagem , Encéfalo/diagnóstico por imagem , Imageamento por Ressonância Magnética , Adulto , Algoritmos , Simulação por Computador , Feminino , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Masculino , Pessoa de Meia-Idade , Modelos Estatísticos , Prótons , Rotação
8.
Int J Neurosci ; 128(6): 563-569, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29098916

RESUMO

BACKGROUND: Conduit-based nerve repairs are commonly used for small nerve gaps, whereas primary repair may be performed if there is no tension on nerve endings. We hypothesize that a conduit-based nerve coaptation device will improve nerve repair outcomes by avoiding sutures at the nerve repair site and utilizing the advantages of a conduit-based repair. METHODS: The left sciatic nerves of female Sprague-Dawley rats were transected and repaired using a novel conduit-based device. The conduit-based device group was compared to a control group of rats that underwent a standard end-to-end microsurgical repair of the sciatic nerve. Animals underwent behavioral assessments at weekly intervals post-operatively using the sciatic functional index (SFI) test. Animals were sacrificed at four weeks to obtain motor axon counts from immunohistochemistry. A sub-group of animals were sacrificed immediately post repair to obtain MRI images. RESULTS: SFI scores were superior in rats which received conduit-based repairs compared to the control group. Motor axon counts distal to the injury in the device group at four weeks were statistically superior to the control group. MRI tractography was used to demonstrate repair of two nerves using the novel conduit device. CONCLUSIONS: A conduit-based nerve coaptation device avoids sutures at the nerve repair site and leads to improved outcomes in a rat model. Conduit-based nerve repair devices have the potential to standardize nerve repairs while improving outcomes.


Assuntos
Matriz Extracelular , Regeneração Nervosa/fisiologia , Traumatismos dos Nervos Periféricos/terapia , Nervo Isquiático , Animais , Imagem de Tensor de Difusão , Modelos Animais de Doenças , Feminino , Microcirurgia , Traumatismos dos Nervos Periféricos/diagnóstico por imagem , Traumatismos dos Nervos Periféricos/cirurgia , Ratos , Ratos Sprague-Dawley , Nervo Isquiático/lesões , Nervo Isquiático/fisiologia , Nervo Isquiático/cirurgia
9.
Magn Reson Med ; 77(2): 707-716, 2017 02.
Artigo em Inglês | MEDLINE | ID: mdl-27037720

RESUMO

PURPOSE: The optic nerve (ON) represents the sole pathway between the eyes and brain; consequently, diseases of the ON can have dramatic effects on vision. However, quantitative magnetization transfer (qMT) applications in the ON have been limited to ex vivo studies, in part because of the fatty connective tissue that surrounds the ON, confounding the magnetization transfer (MT) experiment. Therefore, the aim of this study was to implement a multi-echo Dixon fat-water separation approach to remove the fat component from MT images. METHODS: MT measurements were taken in a single slice of the ON and frontal lobe using a three-echo Dixon readout, and the water and out-of-phase images were applied to a two-pool model in ON tissue and brain white matter to evaluate the effectiveness of using Dixon fat-water separation to remove fatty tissue from MT images. RESULTS: White matter data showed no significant differences between image types; however, there was a significant increase (p < 0.05) in variation in the out-of-phase images in the ON relative to the water images. CONCLUSIONS: The results of this study demonstrate that Dixon fat-water separation can be robustly used for accurate MT quantification of anatomies susceptible to partial volume effects resulting from fat. Magn Reson Med 77:707-716, 2017. © 2016 International Society for Magnetic Resonance in Medicine.


Assuntos
Tecido Adiposo/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Nervo Óptico/diagnóstico por imagem , Água/química , Tecido Adiposo/química , Adulto , Algoritmos , Feminino , Humanos , Masculino , Adulto Jovem
10.
Ann Plast Surg ; 79(6): 590-599, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29053522

RESUMO

BACKGROUND: The management of peripheral nerve injuries remains a large challenge for plastic surgeons. With the inability to fuse axonal endings, results after microsurgical nerve repair have been inconsistent. Our current nerve repair strategies rely upon the slow and lengthy process of axonal regeneration (~1 mm/d). Polyethylene glycol (PEG) has been investigated as a potential axonal fusion agent; however, the percentage of axonal fusion has been inconsistent. The purpose of this study was to identify a PEG delivery device to standardize outcomes after attempted axonal fusion with PEG. MATERIALS AND METHODS: We used a rat sciatic nerve injury model in which we completely transected and repaired the left sciatic nerve to evaluate the efficacy of PEG fusion over a span of 12 weeks. In addition, we evaluated the effectiveness of a delivery device's ability to optimize results after PEG fusion. RESULTS: We found that PEG rapidly (within minutes) restores axonal continuity as assessed by electrophysiology, fluorescent retrograde tracer, and diffusion tensor imaging. Immunohistochemical analysis shows that motor axon counts are significantly increased at 1 week, 4 weeks, and 12 weeks postoperatively in PEG-treated animals. Furthermore, PEG restored behavioral functions up to 50% compared with animals that received the criterion standard epineurial repair (control animals). CONCLUSIONS: The ability of PEG to rapidly restore nerve function after neurotmesis could have vast implications on the clinical management of traumatic injuries to peripheral nerves.


Assuntos
Sistemas de Liberação de Medicamentos/instrumentação , Regeneração Nervosa/efeitos dos fármacos , Traumatismos dos Nervos Periféricos/cirurgia , Polietilenoglicóis/farmacologia , Nervo Isquiático/lesões , Traumatismos do Sistema Nervoso/cirurgia , Animais , Axônios/efeitos dos fármacos , Modelos Animais de Doenças , Eletromiografia/métodos , Feminino , Imuno-Histoquímica , Masculino , Regeneração Nervosa/fisiologia , Procedimentos Neurocirúrgicos/métodos , Traumatismos dos Nervos Periféricos/tratamento farmacológico , Distribuição Aleatória , Ratos , Ratos Sprague-Dawley , Recuperação de Função Fisiológica , Nervo Isquiático/cirurgia
11.
Magn Reson Med ; 76(3): 826-37, 2016 09.
Artigo em Inglês | MEDLINE | ID: mdl-26414937

RESUMO

PURPOSE: To develop a chemical exchange saturation transfer (CEST) scheme sensitive to hydroxyl protons at 3 T. Clinical imaging of hydroxyl moieties can have an impact on osteoarthritis, neuropsychiatric disorders, and cancer. THEORY: By varying saturation amplitude linearly with frequency offset, the direct water saturation component of the Z-spectrum is flattened and can be subtracted to produce a magnetization transfer ratio difference spectrum (MTRdiff ) that isolates solute resonances. Variable saturation power allows for near optimization of hydroxyl and amine/amide moieties in one Z-spectrum. METHODS: Phantom studies were used to test vCEST performance in two environments: (1) aqueous single-solute (glycogen, glucose); (2) aqueous multiple solute (glycogen with bovine serum albumin). In vivo vCEST imaging of glycosaminoglycan content in patellar-femoral cartilage was performed in a subject with history of cartilage transplant. RESULTS: In solutions with overlapping resonances, vCEST resolves separate hydroxyl and amine/amide peaks. CEST hydroxyl signal in cartilage is negligible, but with vCEST, hydroxyl signal ranged from 2 to 5% ppm and showed distinct contrast between lesions and normal appearing cartilage. CONCLUSION: Introduced a variable saturation amplitude CEST (vCEST) scheme to improve sensitivity to exchangeable hydroxyl moieties at 3 T resulting in detection of hydroxyl in the presence of multiple solutes with overlapping resonances. Magn Reson Med 76:826-837, 2016. © 2015 Wiley Periodicals, Inc.


Assuntos
Algoritmos , Radical Hidroxila/química , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Espectroscopia de Ressonância Magnética/métodos , Água/química , Radical Hidroxila/análise , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Água/análise
12.
NMR Biomed ; 29(4): 400-10, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-27077155

RESUMO

Mapping axon diameter is of interest for the potential diagnosis and monitoring of various neuronal pathologies. Advanced diffusion-weighted MRI methods have been developed to measure mean axon diameters non-invasively, but suffer major drawbacks that prevent their direct translation into clinical practice, such as complex non-linear data fitting and, more importantly, long scanning times that are usually not tolerable for most human subjects. In the current study, temporal diffusion spectroscopy using oscillating diffusion gradients was used to measure mean axon diameters with high sensitivity to small axons in the central nervous system. Axon diameters have been found to be correlated with a novel metric, DDR⊥ (the rate of dispersion of the perpendicular diffusion coefficient with gradient frequency), which is a model-free quantity that does not require complex data analyses and can be obtained from two diffusion coefficient measurements in clinically relevant times with conventional MRI machines. A comprehensive investigation including computer simulations and animal experiments ex vivo showed that measurements of DDR⊥ agree closely with histological data. In humans in vivo, DDR⊥ was also found to correlate well with reported mean axon diameters in human corpus callosum, and the total scan time was only about 8 min. In conclusion, DDR⊥ may have potential to serve as a fast, simple and model-free approach to map the mean axon diameter of white matter in clinics for assessing axon diameter changes.


Assuntos
Axônios/patologia , Imagem de Difusão por Ressonância Magnética/métodos , Adulto , Animais , Feminino , Humanos , Masculino , Ratos Sprague-Dawley , Fatores de Tempo
13.
NMR Biomed ; 29(12): 1720-1728, 2016 12.
Artigo em Inglês | MEDLINE | ID: mdl-27753155

RESUMO

Muscle blood oxygenation-level dependent (BOLD) contrast is greater in magnitude and potentially more influenced by extravascular BOLD mechanisms at 7 T than it is at lower field strengths. Muscle BOLD imaging of muscle contractions at 7 T could, therefore, provide greater or different contrast than at 3 T. The purpose of this study was to evaluate the feasibility of using BOLD imaging at 7 T to assess the physiological responses to in vivo muscle contractions. Thirteen subjects (four females) performed a series of isometric contractions of the calf muscles while being scanned in a Philips Achieva 7 T human imager. Following 2 s maximal isometric plantarflexion contractions, BOLD signal transients ranging from 0.3 to 7.0% of the pre-contraction signal intensity were observed in the soleus muscle. We observed considerable inter-subject variability in both the magnitude and time course of the muscle BOLD signal. A subset of subjects (n = 7) repeated the contraction protocol at two different repetition times (TR : 1000 and 2500 ms) to determine the potential of T1 -related inflow effects on the magnitude of the post-contractile BOLD response. Consistent with previous reports, there was no difference in the magnitude of the responses for the two TR values (3.8 ± 0.9 versus 4.0 ± 0.6% for TR  = 1000 and 2500 ms, respectively; mean ± standard error). These results demonstrate that studies of the muscle BOLD responses to contractions are feasible at 7 T. Compared with studies at lower field strengths, post-contractile 7 T muscle BOLD contrast may afford greater insight into microvascular function and dysfunction.


Assuntos
Volume Sanguíneo/fisiologia , Imageamento por Ressonância Magnética/métodos , Contração Muscular/fisiologia , Músculo Esquelético/fisiologia , Consumo de Oxigênio/fisiologia , Resistência Física/fisiologia , Adulto , Velocidade do Fluxo Sanguíneo/fisiologia , Feminino , Humanos , Masculino , Músculo Esquelético/anatomia & histologia , Músculo Esquelético/irrigação sanguínea , Oxigênio/sangue , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
14.
Mult Scler ; 22(3): 320-8, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26209591

RESUMO

BACKGROUND: The clinical course of multiple sclerosis (MS) is mainly attributable to cervical and upper thoracic spinal cord dysfunction. High-resolution, 7T anatomical imaging of the cervical spinal cord is presented. Image contrast between gray/white matter and lesions surpasses conventional, clinical T1- and T2-weighted sequences at lower field strengths. OBJECTIVE: To study the spinal cord of healthy controls and patients with MS using magnetic resonance imaging at 7T. METHODS: Axial (C2-C5) T1- and T2*-weighted and sagittal T2*-/spin-density-weighted images were acquired at 7T in 13 healthy volunteers (age 22-40 years), and 15 clinically diagnosed MS patients (age 19-53 years, Extended Disability Status Scale, (EDSS) 0-3) in addition to clinical 3T scans. In healthy volunteers, a high-resolution multi-echo gradient echo scan was obtained over the same geometry at 3T. Evaluation included signal and contrast to noise ratios and lesion counts for healthy and patient volunteers, respectively. RESULTS/CONCLUSION: High-resolution images at 7T exceeded resolutions reported at lower field strengths. Gray and white matter were sharply demarcated and MS lesions were more readily visualized at 7T compared to clinical acquisitions, with lesions apparent at both fields. Nerve roots were clearly visualized. White matter lesion counts averaged 4.7 vs 3.1 (52% increase) per patient at 7T vs 3T, respectively (p=0.05).


Assuntos
Imageamento por Ressonância Magnética/métodos , Esclerose Múltipla/diagnóstico por imagem , Esclerose Múltipla/patologia , Medula Espinal/patologia , Adulto , Medula Cervical/diagnóstico por imagem , Medula Cervical/patologia , Feminino , Humanos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Masculino , Pessoa de Meia-Idade , Adulto Jovem
15.
Magn Reson Med ; 73(3): 1065-74, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24753216

RESUMO

PURPOSE: Fast, quantitative T2 mapping is of value to both clinical and research environments. However, many protocols utilizing fast spin echo (FSE) pulse sequences contain acceleration-induced artifacts that are compounded when fitting parameter maps, especially in the presence of imperfect refocusing. This work presents a B1 -corrected, model-based reconstruction and associated Cartesian FSE phase-encode ordering that provides enhanced accuracy in T2 estimates compared with other common accelerated protocols. THEORY AND METHODS: The method, known as multiple echo, Caesar cipher acquisition and model-based reconstruction (ME-CAMBREC), directly fitted T2 , flip angle, and proton density maps on a row-by-row basis to k-space data using the extended phase graph model. Regularization was enforced in order to minimize noise amplification effects. ME-CAMBREC was evaluated in computational and physical phantoms, as well as human brain, and compared with other FSE-based T2 mapping protocols, DESPOT2, and parallel imaging acceleration. RESULTS: In computational, phantom, and human experiments, ME-CAMBREC provided T2 maps with fewer artifacts and less or similar error compared with other methods tested at moderate-to-high acceleration factors. In vivo, ME-CAMBREC provided error rates approximately one-half those of other methods. CONCLUSION: Directly fitting multi-echo data to k-space using the extended phase graph can increase fidelity of T2 maps significantly, especially when using an appropriate phase-encode ordering.


Assuntos
Algoritmos , Artefatos , Encéfalo/anatomia & histologia , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
16.
Neurosurg Focus ; 39(3): E9, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26323827

RESUMO

Diagnosis and management of peripheral nerve injury is complicated by the inability to assess microstructural features of injured nerve fibers via clinical examination and electrophysiology. Diffusion tensor imaging (DTI) has been shown to accurately detect nerve injury and regeneration in crush models of peripheral nerve injury, but no prior studies have been conducted on nerve transection, a surgical emergency that can lead to permanent weakness or paralysis. Acute sciatic nerve injuries were performed microsurgically to produce multiple grades of nerve transection in rats that were harvested 1 hour after surgery. High-resolution diffusion tensor images from ex vivo sciatic nerves were obtained using diffusion-weighted spin-echo acquisitions at 4.7 T. Fractional anisotropy was significantly reduced at the injury sites of transected rats compared with sham rats. Additionally, minor eigenvalues and radial diffusivity were profoundly elevated at all injury sites and were negatively correlated to the degree of injury. Diffusion tensor tractography showed discontinuities at all injury sites and significantly reduced continuous tract counts. These findings demonstrate that high-resolution DTI is a promising tool for acute diagnosis and grading of traumatic peripheral nerve injuries.


Assuntos
Imagem de Tensor de Difusão , Traumatismos dos Nervos Periféricos/diagnóstico , Doença Aguda , Animais , Anisotropia , Modelos Animais de Doenças , Feminino , Humanos , Extremidade Inferior/patologia , Masculino , Curva ROC , Ratos Sprague-Dawley , Neuropatia Ciática/diagnóstico , Sensibilidade e Especificidade , Estatística como Assunto
17.
Neuroimage ; 95: 106-16, 2014 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-24632465

RESUMO

Quantitative magnetization transfer (qMT) imaging can provide indices describing the interactions between free water protons and immobile macromolecular protons. These indices include the macromolecular proton fraction (MPF), which has been shown to correlate with myelin content in white matter. Because of the long scan times required for high-resolution spinal cord imaging, qMT studies of the human spinal cord have not found wide-spread application. Herein, we investigated whether these limitations could be overcome by utilizing only a single MT-weighted acquisition and a reference measurement, as was recently proposed in the brain. High-resolution, in vivo qMT data were obtained at 3.0T in the spinal cords of healthy volunteers and patients with relapsing remitting multiple sclerosis (MS). Low- and high-resolution acquisitions (low/high resolution=1×1×5mm(3)/0.65×0.65×5mm(3)) with clinically acceptable scan times (12min/7min) were evaluated. We also evaluated the reliability over time and the sensitivity of the model to the assumptions made in the single-point method, both in disease and healthy tissues. Our findings suggest that the single point qMT technique can provide maps of the MPF in the spinal cord in vivo with excellent grey/white matter contrast, can be reliably obtained within reasonable scan times, and are sensitive to MS pathology. Consistent with previous qMT studies in the brain, the observed MPF values were higher in healthy white matter (0.16±0.01) than in grey matter (0.13±0.01) and in MS lesions (0.09±0.01). The single point qMT technique applied at high resolution provides an improved method for obtaining qMT in the human spinal cord and may offer a reliable outcome measure for evaluating spinal cord disease.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Esclerose Múltipla Recidivante-Remitente/patologia , Medula Espinal/patologia , Adulto , Feminino , Humanos , Masculino , Fatores de Tempo , Adulto Jovem
18.
NMR Biomed ; 27(9): 1070-84, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25066274

RESUMO

Muscle diseases commonly have clinical presentations of inflammation, fat infiltration, fibrosis, and atrophy. However, the results of existing laboratory tests and clinical presentations are not well correlated. Advanced quantitative MRI techniques may allow the assessment of myo-pathological changes in a sensitive and objective manner. To progress towards this goal, an array of quantitative MRI protocols was implemented for human thigh muscles; their reproducibility was assessed; and the statistical relationships among parameters were determined. These quantitative methods included fat/water imaging, multiple spin-echo T2 imaging (with and without fat signal suppression, FS), selective inversion recovery for T1 and quantitative magnetization transfer (qMT) imaging (with and without FS), and diffusion tensor imaging. Data were acquired at 3.0 T from nine healthy subjects. To assess the repeatability of each method, the subjects were re-imaged an average of 35 days later. Pre-testing lifestyle restrictions were applied to standardize physiological conditions across scans. Strong between-day intra-class correlations were observed in all quantitative indices except for the macromolecular-to-free water pool size ratio (PSR) with FS, a metric derived from qMT data. Two-way analysis of variance revealed no significant between-day differences in the mean values for any parameter estimate. The repeatability was further assessed with Bland-Altman plots, and low repeatability coefficients were obtained for all parameters. Among-muscle differences in the quantitative MRI indices and inter-class correlations among the parameters were identified. There were inverse relationships between fractional anisotropy (FA) and the second eigenvalue, the third eigenvalue, and the standard deviation of the first eigenvector. The FA was positively related to the PSR, while the other diffusion indices were inversely related to the PSR. These findings support the use of these T1 , T2 , fat/water, and DTI protocols for characterizing skeletal muscle using MRI. Moreover, the data support the existence of a common biophysical mechanism, water content, as a source of variation in these parameters.


Assuntos
Tecido Adiposo/anatomia & histologia , Água Corporal/metabolismo , Imagem de Tensor de Difusão/métodos , Interpretação de Imagem Assistida por Computador/métodos , Músculo Esquelético/anatomia & histologia , Músculo Esquelético/metabolismo , Tecido Adiposo/metabolismo , Adulto , Algoritmos , Humanos , Masculino , Imagem Multimodal/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Coxa da Perna
19.
Magn Reson Imaging ; 2024 Jul 04.
Artigo em Inglês | MEDLINE | ID: mdl-38971264

RESUMO

PURPOSE: Multi-echo, multi-contrast methods are increasingly used in dynamic imaging studies to simultaneously quantify R2* and R2. To overcome the computational challenges associated with nonlinear least squares (NLSQ) fitting, we propose a generalized linear least squares (LLSQ) solution to rapidly fit R2* and R2. METHODS: Spin- and gradient-echo (SAGE) data were simulated across T2⁎ and T2 values at high (200) and low (20) SNR. Full (four-parameter) and reduced (three-parameter) parameter fits were implemented and compared with both LLSQ and NLSQ fitting. Fit data were compared to ground truth using concordance correlation coefficient (CCC) and coefficient of variation (CV). In vivo SAGE perfusion data were acquired in 20 subjects with relapsing-remitting multiple sclerosis. LLSQ R2* and R2, as well as cerebral blood volume (CBV), were compared with the standard NLSQ approach. RESULTS: Across all fitting methods, T2⁎ was well-fit at high (CCC = 1, CV = 0) and low (CCC ≥ 0.87, CV ≤ 0.08) SNR. Except for short T2⁎ values (5-15 ms), T2 was well-fit at high (CCC = 1, CV = 0) and low (CCC ≥ 0.99, CV ≤ 0.03) SNR. In vivo, LLSQ R2⁎ and R2 estimates were similar to NLSQ, and there were no differences in R2⁎ across fitting methods at high SNR. However, there were some differences at low SNR and for R2 at high and low SNR. In vivo NLSQ and LLSQ three parameter fits performed similarly, as did NLSQ and LLSQ four-parameter fits. LLSQ CBV nearly matched the standard NLSQ method for R2*- (0.97 ratio) and R2-CBV (0.98 ratio). Voxel-wise whole-brain fitting was faster for LLSQ (3-4 min) than NLSQ (16-18 h). CONCLUSIONS: LLSQ reliably fit for R2* and R2 in simulated and in vivo data. Use of LLSQ methods reduced the computational demand, enabling rapid estimation of R2⁎ and R2.

20.
Neuroimage ; 64: 640-9, 2013 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-22940589

RESUMO

Quantitative magnetization transfer (qMT) imaging yields indices describing the interactions between free water protons and immobile macromolecular protons. These indices include the macromolecular to free pool size ratio (PSR), which has been shown to be correlated with myelin content in white matter. Because of the long scan times required for whole-brain imaging (≈20-30 min), qMT studies of the human brain have not found widespread application. Herein, we investigated whether the increased signal-to-noise ratio available at 7.0 T could be used to reduce qMT scan times. More specifically, we developed a selective inversion recovery (SIR) qMT imaging protocol with a i) novel transmit radiofrequency (B(1)(+)) and static field (B(0)) insensitive inversion pulse, ii) turbo field-echo readout, and iii) reduced TR. In vivo qMT data were obtained in the brains of healthy volunteers at 7.0 T using the resulting protocol (scan time≈40 s/slice, resolution=2 × 2 × 3 mm(3)). Reliability was also assessed in repeated acquisitions. The results of this study demonstrate that SIR qMT imaging can be reliably performed within the radiofrequency power restrictions present at 7.0 T, even in the presence of large B(1)(+) and B(0) inhomogeneities. Consistent with qMT studies at lower field strengths, the observed PSR values were higher in white matter (mean±SD=17.6 ± 1.3%) relative to gray matter (10.3 ± 1.6%) at 7.0 T. In addition, regional variations in PSR were observed in white matter. Together, these results suggest that qMT measurements are feasible at 7.0 T and may eventually allow for the high-resolution assessment of changes in composition throughout the normal and diseased human brain in vivo.


Assuntos
Algoritmos , Encéfalo/citologia , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Fibras Nervosas Mielinizadas/ultraestrutura , Adulto , Feminino , Humanos , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA