Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 31
Filtrar
Mais filtros

Base de dados
Tipo de documento
País/Região como assunto
Intervalo de ano de publicação
1.
Blood ; 2024 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-38805639

RESUMO

Loss of long-term hematopoietic stem cell (LT-HSC) function ex vivo hampers the success of clinical protocols reliant on culture. However, the kinetics and mechanisms by which this occurs remain incompletely characterized. Here, through time-resolved scRNA-Seq, matched in vivo functional analysis and the use of a reversible in vitro system of early G1 arrest, we define the sequence of transcriptional and functional events occurring during the first ex vivo division of human LT-HSCs. We demonstrate that the sharpest loss of LT-HSC repopulation capacity happens early on, between 6 and 24 hours of culture, before LT-HSCs commit to cell cycle progression. During this time window, LT-HSCs adapt to the culture environment, limiting global variability in gene expression and transiently upregulating gene networks involved in signaling and stress responses. From 24 hours, LT-HSC progression past early G1 contributes to the establishment of differentiation programmes in culture. However, contrary to current assumptions, we demonstrate that loss of HSC function ex vivo is independent of cell cycle progression. Finally, we show that targeting LT-HSC adaptation to culture by inhibiting early activation of JAK/STAT signaling improves HSC long-term repopulating function ex vivo. Collectively, our study demonstrates that controlling early LT-HSC adaptation to ex vivo culture, for example via JAK inhibition, is of critical importance to improve HSC gene therapy and expansion protocols.

2.
J Synchrotron Radiat ; 29(Pt 4): 1004-1013, 2022 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-35787567

RESUMO

The DIAD beamline for Dual Imaging and Diffraction at Diamond Light Source has opted to use an industrial robot to position its Dectris Pilatus 2M CdTe diffraction detector. This setup was chosen to enable flexible positioning of the detector in a quarter-sphere around the sample position whilst reliably holding the large weight of 139 kg of detector, detector mount and cabling in a stable position. Metrology measurements showed that the detector can be positioned with a linear repeatability of <19.7 µm and a rotational repeatability of <16.3 µrad. The detector position stays stable for a 12 h period with <10.1 µm of movement for linear displacement and <3.8 µrad for rotational displacement. X-ray diffraction from calibration samples confirmed that the robot is sufficiently stable to resolve lattice d-spacings within the instrumental broadening given by detector position and beam divergence.

3.
J Synchrotron Radiat ; 28(Pt 6): 1985-1995, 2021 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-34738954

RESUMO

The Dual Imaging and Diffraction (DIAD) beamline at Diamond Light Source is a new dual-beam instrument for full-field imaging/tomography and powder diffraction. This instrument provides the user community with the capability to dynamically image 2D and 3D complex structures and perform phase identification and/or strain mapping using micro-diffraction. The aim is to enable in situ and in operando experiments that require spatially correlated results from both techniques, by providing measurements from the same specimen location quasi-simultaneously. Using an unusual optical layout, DIAD has two independent beams originating from one source that operate in the medium energy range (7-38 keV) and are combined at one sample position. Here, either radiography or tomography can be performed using monochromatic or pink beam, with a 1.4 mm × 1.2 mm field of view and a feature resolution of 1.2 µm. Micro-diffraction is possible with a variable beam size between 13 µm × 4 µm and 50 µm × 50 µm. One key functionality of the beamline is image-guided diffraction, a setup in which the micro-diffraction beam can be scanned over the complete area of the imaging field-of-view. This moving beam setup enables the collection of location-specific information about the phase composition and/or strains at any given position within the image/tomography field of view. The dual beam design allows fast switching between imaging and diffraction mode without the need of complicated and time-consuming mode switches. Real-time selection of areas of interest for diffraction measurements as well as the simultaneous collection of both imaging and diffraction data of (irreversible) in situ and in operando experiments are possible.

4.
Opt Express ; 29(12): 17849-17874, 2021 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-34154059

RESUMO

Parallel-beam tomography systems at synchrotron facilities have limited field of view (FOV) determined by the available beam size and detector system coverage. Scanning the full size of samples bigger than the FOV requires various data acquisition schemes such as grid scan, 360-degree scan with offset center-of-rotation (COR), helical scan, or combinations of these schemes. Though straightforward to implement, these scanning techniques have not often been used due to the lack of software and methods to process such types of data in an easy and automated fashion. The ease of use and automation is critical at synchrotron facilities where using visual inspection in data processing steps such as image stitching, COR determination, or helical data conversion is impractical due to the large size of datasets. Here, we provide methods and their implementations in a Python package, named Algotom, for not only processing such data types but also with the highest quality possible. The efficiency and ease of use of these tools can help to extend applications of parallel-beam tomography systems.

5.
Dev Biol ; 435(2): 122-129, 2018 03 15.
Artigo em Inglês | MEDLINE | ID: mdl-29352963

RESUMO

The extracellular matrix (ECM) plays a crucial role in embryogenesis, serving both as a substrate to which cells attach and as an active regulator of cell behavior. However, little is known about the spatiotemporal expression patterns and 3D structure of ECM proteins during embryonic development. The lack of suitable methods to visualize the embryonic ECM is largely responsible for this gap, posing a major technical challenge for biologists and tissue engineers. Here, we describe a method of viewing the 3D organization of the ECM using a polyacrylamide-based hydrogel to provide a 3D framework within developing murine embryos. After removal of soluble proteins using sodium dodecyl sulfate, confocal microscopy was used to visualize the 3D distribution of independent ECM networks in multiple developing tissues, including the forelimb, eye, and spinal cord. Comparative analysis of E12.5 and E14.5 autopods revealed proteoglycan-rich fibrils maintain connections between the epidermis and the underlying tendon and cartilage, indicating a role for the ECM during musculoskeletal assembly and demonstrating that our method can be a powerful tool for defining the spatiotemporal distribution of the ECM during embryogenesis.


Assuntos
Desenvolvimento Embrionário , Matriz Extracelular/ultraestrutura , Microscopia Confocal/métodos , Inclusão do Tecido/métodos , Resinas Acrílicas , Animais , Detergentes/farmacologia , Epiderme/ultraestrutura , Proteínas da Matriz Extracelular/efeitos dos fármacos , Proteínas da Matriz Extracelular/ultraestrutura , Corantes Fluorescentes , Membro Anterior/embriologia , Membro Anterior/ultraestrutura , Formaldeído , Hidrogéis , Camundongos , Camundongos Endogâmicos C57BL , Morfogênese , Polímeros , Proteoglicanas/análise , Dodecilsulfato de Sódio/farmacologia , Manejo de Espécimes , Coloração e Rotulagem/métodos , Tendões/embriologia , Tendões/ultraestrutura , Fixação de Tecidos
6.
J Synchrotron Radiat ; 25(Pt 4): 1182-1188, 2018 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-29979180

RESUMO

X-ray phase-contrast imaging can substantially enhance image contrast for weakly absorbing samples. The fabrication of dedicated optics remains a major barrier, especially in high-energy regions (i.e. over 50 keV). Here, the authors perform X-ray phase-contrast imaging by using engineered porous materials as random absorption masks, which provides an alternative solution to extend X-ray phase-contrast imaging into previously challenging higher energy regions. The authors have measured various samples to demonstrate the feasibility of the proposed engineering materials. This technique could potentially be useful for studying samples across a wide range of applications and disciplines.

7.
Opt Express ; 26(22): 28396-28412, 2018 Oct 29.
Artigo em Inglês | MEDLINE | ID: mdl-30470012

RESUMO

Synchrotron-based X-ray micro-tomography systems often suffer severe ring artifacts in reconstructed images. In sinograms the artifacts appear as straight lines or stripe artifacts. These artifacts are caused by the irregular response of a detecting system giving rise to a variety of observed types of stripes: full stripes, partial stripes, fluctuating stripes, and unresponsive stripes. The use of pre-processing techniques such as distortion correction or phase retrieval blurs and enlarges these stripes. It is impossible for a single approach to remove all types of stripe artifacts. Here, we propose three techniques for tackling all of them. The proposed techniques are easy to implement; do not generate extra stripe artifacts and void-center artifacts; and give superior quality on challenging data sets and in comparison with other techniques. Implementations in Python and a challenging data set are available for download.

8.
Proc Biol Sci ; 283(1827): 20160125, 2016 03 30.
Artigo em Inglês | MEDLINE | ID: mdl-27030415

RESUMO

Spiders are an important animal group, with a long history. Details of their origins remain limited, with little knowledge of their stem group, and no insights into the sequence of character acquisition during spider evolution. We describe a new fossil arachnid, Idmonarachne brasierigen. et sp. nov. from the Late Carboniferous (Stephanian,ca 305-299 Ma) of Montceau-les-Mines, France. It is three-dimensionally preserved within a siderite concretion, allowing both laboratory- and synchrotron-based phase-contrast computed tomography reconstruction. The latter is a first for siderite-hosted fossils and has allowed us to investigate fine anatomical details. Although distinctly spider-like in habitus, this remarkable fossil lacks a key diagnostic character of Araneae: spinnerets on the underside of the opisthosoma. It also lacks a flagelliform telson found in the recently recognized, spider-related, Devonian-Permian Uraraneida. Cladistic analysis resolves our new fossil as sister group to the spiders: the spider stem-group comprises the uraraneids and I. brasieri While we are unable to demonstrate the presence of spigots in this fossil, the recovered phylogeny suggests the earliest character to evolve on the spider stem-group is the secretion of silk. This would have been followed by the loss of a flagelliform telson, and then the ability to spin silk using spinnerets. This last innovation defines the true spiders, significantly post-dates the origins of silk, and may be a key to the group's success. The Montceau-les-Mines locality has previously yielded a mesothele spider (with spinnerets). Evidently, Late Palaeozoic spiders lived alongside Palaeozoic arachnid grades which approached the spider condition, but did not express the full suite of crown-group autapomorphies.


Assuntos
Aracnídeos/anatomia & histologia , Evolução Biológica , Fósseis/anatomia & histologia , Animais , Aracnídeos/classificação , Aracnídeos/fisiologia , França , Filogenia , Aranhas/anatomia & histologia , Aranhas/fisiologia
9.
J Synchrotron Radiat ; 23(Pt 3): 685-93, 2016 05.
Artigo em Inglês | MEDLINE | ID: mdl-27140147

RESUMO

The short pulse duration, small effective source size and high flux of synchrotron radiation is ideally suited for probing a wide range of transient deformation processes in materials under extreme conditions. In this paper, the challenges of high-resolution time-resolved indirect X-ray detection are reviewed in the context of dynamic synchrotron experiments. In particular, the discussion is targeted at two-dimensional integrating detector methods, such as those focused on dynamic radiography and diffraction experiments. The response of a scintillator to periodic synchrotron X-ray excitation is modelled and validated against experimental data collected at the Diamond Light Source (DLS) and European Synchrotron Radiation Facility (ESRF). An upper bound on the dynamic range accessible in a time-resolved experiment for a given bunch separation is calculated for a range of scintillators. New bunch structures are suggested for DLS and ESRF using the highest-performing commercially available crystal LYSO:Ce, allowing time-resolved experiments with an interframe time of 189 ns and a maximum dynamic range of 98 (6.6 bits).

10.
J Synchrotron Radiat ; 22(3): 828-38, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25931103

RESUMO

I12 is the Joint Engineering, Environmental and Processing (JEEP) beamline, constructed during Phase II of the Diamond Light Source. I12 is located on a short (5 m) straight section of the Diamond storage ring and uses a 4.2 T superconducting wiggler to provide polychromatic and monochromatic X-rays in the energy range 50-150 keV. The beam energy enables good penetration through large or dense samples, combined with a large beam size (1 mrad horizontally × 0.3 mrad vertically). The beam characteristics permit the study of materials and processes inside environmental chambers without unacceptable attenuation of the beam and without the need to use sample sizes which are atypically small for the process under study. X-ray techniques available to users are radiography, tomography, energy-dispersive diffraction, monochromatic and white-beam two-dimensional diffraction/scattering and small-angle X-ray scattering. Since commencing operations in November 2009, I12 has established a broad user community in materials science and processing, chemical processing, biomedical engineering, civil engineering, environmental science, palaeontology and physics.


Assuntos
Cristalografia por Raios X/instrumentação , Lasers , Aceleradores de Partículas/instrumentação , Espectrometria por Raios X/instrumentação , Raios X , Transferência de Energia , Desenho de Equipamento , Análise de Falha de Equipamento , Iluminação/instrumentação , Reino Unido
11.
Opt Express ; 23(25): 32859-68, 2015 Dec 14.
Artigo em Inglês | MEDLINE | ID: mdl-26699073

RESUMO

Distortion correction or camera calibration for an imaging system which is highly configurable and requires frequent disassembly for maintenance or replacement of parts needs a speedy method for recalibration. Here we present direct techniques for calculating distortion parameters of a non-linear model based on the correct determination of the center of distortion. These techniques are fast, very easy to implement, and accurate at sub-pixel level. The implementation at the X-ray tomography system of the I12 beamline, Diamond Light Source, which strictly requires sub-pixel accuracy, shows excellent performance in the calibration image and in the reconstructed images.

12.
Philos Trans A Math Phys Eng Sci ; 373(2043)2015 Jun 13.
Artigo em Inglês | MEDLINE | ID: mdl-25939626

RESUMO

Tomographic datasets collected at synchrotrons are becoming very large and complex, and, therefore, need to be managed efficiently. Raw images may have high pixel counts, and each pixel can be multidimensional and associated with additional data such as those derived from spectroscopy. In time-resolved studies, hundreds of tomographic datasets can be collected in sequence, yielding terabytes of data. Users of tomographic beamlines are drawn from various scientific disciplines, and many are keen to use tomographic reconstruction software that does not require a deep understanding of reconstruction principles. We have developed Savu, a reconstruction pipeline that enables users to rapidly reconstruct data to consistently create high-quality results. Savu is designed to work in an 'orthogonal' fashion, meaning that data can be converted between projection and sinogram space throughout the processing workflow as required. The Savu pipeline is modular and allows processing strategies to be optimized for users' purposes. In addition to the reconstruction algorithms themselves, it can include modules for identification of experimental problems, artefact correction, general image processing and data quality assessment. Savu is open source, open licensed and 'facility-independent': it can run on standard cluster infrastructure at any institution.

13.
J Am Chem Soc ; 136(2): 630-3, 2014 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-24354523

RESUMO

The development of a technique for following in situ the reactions of solids with alkali metal/ammonia solutions, using time-resolved X-ray diffraction methods, reveals high-temperature superconducting ammonia-rich intercalates of iron selenide which reversibly absorb and desorb ammonia around ambient temperatures.

14.
Opt Express ; 22(16): 19078-86, 2014 Aug 11.
Artigo em Inglês | MEDLINE | ID: mdl-25320994

RESUMO

High-throughput processing of parallel-beam X-ray tomography at synchrotron facilities is lacking a reliable and robust method to determine the center of rotation in an automated fashion, i.e. without the need for a human scorer. Well-known techniques based on center of mass calculation, image registration, or reconstruction evaluation work well under favourable conditions but they fail in cases where samples are larger than field of view, when the projections show low signal-to-noise, or when optical defects dominate the contrast. Here we propose an alternative technique which is based on the Fourier analysis of the sinogram. Our technique shows excellent performance particularly on challenging data.


Assuntos
Rotação , Tomografia/métodos , Artefatos , Análise de Fourier , Processamento de Imagem Assistida por Computador , Compostos de Magnésio/química , Imagens de Fantasmas , Fosfatos/química , Reprodutibilidade dos Testes
15.
Artigo em Inglês | MEDLINE | ID: mdl-38752915

RESUMO

BACKGROUND AND OBJECTIVE: Machine teaching, a machine learning subfield, may allow for rapid development of artificial intelligence systems able to automatically identify emerging ocular biomarkers from small imaging datasets. We sought to use machine teaching to automatically identify retinal ischemic perivascular lesions (RIPLs) and subretinal drusenoid deposits (SDDs), two emerging ocular biomarkers of cardiovascular disease. MATERIALS AND METHODS: IRB approval was obtained. Four small datasets of SD-OCT B-scans were used to train and test two distinct automated systems, one identifying RIPLs and the other identifying SDDs. An open-source interactive machine-learning software program, RootPainter, was used to perform annotation and training simultaneously over a 6-hour period. RESULTS: For SDDs at the B-scan level, test-set accuracy = 92%, sensitivity = 100%, specificity = 88%, positive predictive value (PPV) = 82%, and negative predictive value (NPV) = 100%. For RIPLs at the B-scan level, test-set accuracy = 90%, sensitivity = 60%, specificity = 93%, PPV = 50%, and NPV = 95%. CONCLUSION: Machine teaching demonstrates promise within ophthalmic imaging to rapidly allow for automated identification of novel biomarkers from small image datasets. [Ophthalmic Surg Lasers Imaging Retina 2024;55:XX-XX.].

16.
Bioengineering (Basel) ; 11(2)2024 Jan 26.
Artigo em Inglês | MEDLINE | ID: mdl-38391606

RESUMO

In the modern era, patients often resort to the internet for answers to their health-related concerns, and clinics face challenges to providing timely response to patient concerns. This has led to a need to investigate the capabilities of AI chatbots for ophthalmic diagnosis and triage. In this in silico study, 80 simulated patient complaints in ophthalmology with varying urgency levels and clinical descriptors were entered into both ChatGPT and Bard in a systematic 3-step submission process asking chatbots to triage, diagnose, and evaluate urgency. Three ophthalmologists graded chatbot responses. Chatbots were significantly better at ophthalmic triage than diagnosis (90.0% appropriate triage vs. 48.8% correct leading diagnosis; p < 0.001), and GPT-4 performed better than Bard for appropriate triage recommendations (96.3% vs. 83.8%; p = 0.008), grader satisfaction for patient use (81.3% vs. 55.0%; p < 0.001), and lower potential harm rates (6.3% vs. 20.0%; p = 0.010). More descriptors improved the accuracy of diagnosis for both GPT-4 and Bard. These results indicate that chatbots may not need to recognize the correct diagnosis to provide appropriate ophthalmic triage, and there is a potential utility of these tools in aiding patients or triage staff; however, they are not a replacement for professional ophthalmic evaluation or advice.

17.
J Synchrotron Radiat ; 20(Pt 2): 316-23, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23412489

RESUMO

The present investigation establishes the feasibility of using synchrotron-generated X-ray beams for time-resolved in situ imaging and diffraction of the interior components of an internal combustion engine during its operation. The demonstration experiment was carried out on beamline I12 (JEEP) at Diamond Light Source, UK. The external hutch of the JEEP instrument is a large-scale engineering test bed for complex in situ processing and simulation experiments. The hutch incorporates a large capacity translation and rotation table and a selection of detectors for monochromatic and white-beam diffraction and imaging. These capabilities were used to record X-ray movies of a motorcycle internal combustion engine running at 1850 r.p.m. and to measure strain inside the connecting rod via stroboscopic X-ray diffraction measurement. The high penetrating ability and high flux of the X-ray beam at JEEP allowed the observation of inlet and outlet valve motion, as well as that of the piston, connecting rod and the timing chain within the engine. Finally, the dynamic internal strain within the moving connecting rod was evaluated with an accuracy of ~50 × 10(-6).

18.
BMJ Open Ophthalmol ; 8(1)2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37493668

RESUMO

BACKGROUND/AIMS: Retinal microvascular ischaemia may produce localised middle retinal disruption with corresponding scotoma, a phenomenon termed paracentral acute middle maculopathy (PAMM). Small chronic middle retinal atrophic lesions termed retinal ischaemic perivascular lesions (RIPLs) appear qualitatively similar to PAMM lesions and have recently been hypothesised to result specifically from PAMM. However, no studies have quantitatively demonstrated an ischaemic origin of RIPLs. We quantitatively investigated the pathophysiology of RIPLs and their relationship with PAMM with swept-source optical coherence tomography angiography (SS-OCTA). METHODS: A total of 14 controls and 25 patients being evaluated for carotid artery stenosis (CAS) were enrolled. SS-OCTA imaging of each eye was taken. Projection-resolved en face 6 mm × 6 mm superficial capillary plexus (SCP) and deep capillary plexus (DCP) images were quantitatively analysed with two algorithms for changes in vessel linear density (VLD) and vessel tortuosity (VT) at RIPLs relative to both the immediately surrounding macula and the entire macula, as well as between eyes with RIPLs and eyes without RIPLs. RESULTS: All controls and 22 of 25 CAS patients were included in the analysis. RIPLs demonstrated a localised decrease in DCP VLD in CAS patients and controls. RIPLs tended to show a localised decrease in SCP VLD in CAS patients but a localised increase in controls. No changes in VT were found. Eyes with RIPLs had VLD and VT similar to their RIPL-free fellow eyes. CONCLUSION: RIPLs are associated with quantifiable local, but not global, ischaemia, supporting the idea of shared pathophysiology with classic PAMM lesions along a continuum of ischaemia severity.


Assuntos
Estenose das Carótidas , Degeneração Retiniana , Humanos , Vasos Retinianos/diagnóstico por imagem , Angiofluoresceinografia/métodos , Tomografia de Coerência Óptica/métodos , Estenose das Carótidas/diagnóstico por imagem , Benchmarking , Isquemia/diagnóstico por imagem , Degeneração Retiniana/patologia
19.
Nat Mater ; 7(7): 551-5, 2008 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-18568031

RESUMO

Zeolites are microporous crystalline materials that find wide application in industry, for example, as catalysts and gas separators, and in our daily life, for example, as adsorbents or as ion exchangers in laundry detergents. The tetrahedrally coordinated silicon and aluminium atoms in the zeolite unit cell occupy the so-called crystallographic T-sites. Besides their pore size, the occupation of specific T-sites by the aluminium atoms determines the performance of the zeolites. Despite its importance, the distribution of aluminium over the crystallographic T-sites remains one of the most challenging, unresolved issues in zeolite science. Here, we report how to determine unambiguously and directly the distribution of aluminium in zeolites by means of the X-ray standing wave technique using brilliant, focused X-rays from a third-generation synchrotron source. We report in detail the analysis of the aluminium distribution in scolecite, which demonstrates how the aluminium occupancy in zeolites can systematically be determined.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA