1.
Eye Contact Lens ; 48(1): 27-32, 2022 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-34608027

RESUMO

OBJECTIVE: To identify corneal structure differences on quantitative high-frequency ultrasound biomicroscopy (UBM) among subjects with congenital glaucoma compared with controls. METHODS: This prospective case-control study evaluated 180 UBM images from 44 eyes of 30 subjects (18 control and 12 glaucoma, mean age 5.2±8.0 years, range 0.2-25.8 years) enrolled in the Pediatric Anterior Segment Imaging and Innovation Study (PASIIS). ImageJ was used to quantify a comprehensive set of corneal structures according to 21 quantitative parameters. Statistical analysis compared corneal measurements in glaucoma subtypes and age-matched controls with significance testing and mixed effects models. RESULTS: Significant differences between congenital glaucoma cases and controls were identified in 16 of 21 measured parameters including angle-to-angle, central and peripheral corneal thicknesses, scleral integrated pixel density, anterior corneal radius of curvature, and posterior corneal radius of curvature. Eight parameters differed significantly between primary congenital glaucoma and glaucoma following congenital cataract surgery. CONCLUSION: Multiple measurable corneal structural differences exist between congenital glaucoma and control eyes, and between primary and secondary congenital glaucoma, including but not limited to corneal width and thickness. The structural differences can be quantified from UBM image analysis. Further studies are needed to determine whether corneal features associated with glaucoma can be used to diagnose or monitor progression of congenital glaucoma.


Assuntos
Glaucoma , Adolescente , Adulto , Estudos de Casos e Controles , Criança , Pré-Escolar , Córnea/diagnóstico por imagem , Glaucoma/diagnóstico , Humanos , Lactente , Microscopia Acústica , Esclera , Adulto Jovem
2.
J AAPOS ; 25(5): 312-314, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34582956

RESUMO

We report a case of spontaneous cataract absorption over a period of 19 weeks in a 5-week-old boy with trisomy 21. Ultrasound biomicroscopy images at 5 and 24 weeks of age showed that 71% of the initial lens thickness was absorbed during this period. At surgery, the lens thickness was 0.92 mm in the right eye and 0.91 mm in the left eye. Uncomplicated cataract extraction was performed. Trypan blue staining revealed an area of possible lens leakage through the anterior lens capsule in the left eye, suggesting a mechanism for cataract absorption.


Assuntos
Extração de Catarata , Catarata , Síndrome de Down , Cápsula do Cristalino , Corantes , Síndrome de Down/complicações , Humanos , Masculino , Azul Tripano
3.
J Glaucoma ; 30(5): e222-e226, 2021 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-33596011

RESUMO

The study was a prospective observational study comparing semiautomated to manual quantitative ultrasound biomicroscopy image analysis among 82 images from 41 eyes of 32 subjects (21 controls and 11 glaucoma) enrolled in the Pediatric Anterior Segment Imaging Innovation Study. Intraclass correlation coefficients and correlation coefficients were >0.8 for all parameters, and comparison of respective analysis speed was 7 times faster for the semiautomated method compared with manual image quantification.


Assuntos
Glaucoma , Microscopia Acústica , Segmento Anterior do Olho/diagnóstico por imagem , Criança , Glaucoma/diagnóstico por imagem , Humanos , Pressão Intraocular , Estudos Prospectivos
4.
Ultrasound Med Biol ; 47(7): 1949-1956, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33858721

RESUMO

Most of the ciliary body and ciliary processes of the eye cannot be directly visualized in vivo because of the posterior location of the pars plicata to the posterior chamber and iris. However, ciliary anatomy can be effectively imaged using ultrasound biomicroscopy (UBM) by placing the probe close to the limbus, perpendicular to this structure. Previous studies measuring ciliary body parameters in meridian UBM images found that these parameters were measured with poor reliability and repeatability. This study evaluates the intra-observer reliability and inter-observer agreement of a standardized protocol for measuring six ciliary parameters in transverse or quadrant UBM images that capture an entire row of ciliary processes. All six ciliary parameters have high intra-observer reliability, with ciliary body thickness, ciliary process length and ciliary process density measurements being the most consistent for each observer. The coefficient of variation for each observer ranged from 1.4%-15%. Inter-observer agreement was also high for all six parameters, with an intra-class correlation coefficient >0.8. Utilizing transverse UBM images of the pars plicata allows for consistent quantitative analysis in control subjects.


Assuntos
Corpo Ciliar/diagnóstico por imagem , Microscopia Acústica , Humanos , Variações Dependentes do Observador , Reprodutibilidade dos Testes