Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 136
Filtrar
1.
Eur J Clin Microbiol Infect Dis ; 27(12): 1239-44, 2008 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-18584222

RESUMO

The objectives of this study were to evaluate the diagnostic value of 99mTc-HMPAO labelled white blood cell scintigraphy (WBCS) in patients with suspected osteomyelitis using late images and to study interobserver reproducibility. This study prospectively included 120 patients, and after a follow-up of one year, only 70 patients (n = 49 with implants, n = 21 without implants) were selected. The final diagnosis of infection was based either on microbiological data (n = 54) or follow-up (n = 16). We performed WBCS with 4 h and 24 h scans. Sensitivity, specificity, positive predictive value, negative predictive value, and accuracy were 77%, 72%, 83%, 64%, and 75% at 4 h, and 74%, 87%, 91%, 59%, and 79% at 24 h, respectively. The interobserver reproducibility shows a 63% prevalence of agreement between results (kappa = 0.5) at 4 h and 80% (kappa = 0.74) at 24 h, respectively. WBCS with 24-h images improves specificity and interobserver reproducibility in patients with suspected osteoarticular sepsis.


Assuntos
Leucócitos/diagnóstico por imagem , Leucócitos/metabolismo , Osteoartrite/diagnóstico , Cintilografia/métodos , Tecnécio Tc 99m Exametazima/metabolismo , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Valor Preditivo dos Testes , Estudos Prospectivos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
2.
Ann Biol Clin (Paris) ; 63(5): 561-5, 2005.
Artigo em Francês | MEDLINE | ID: mdl-16230298

RESUMO

OBJECTIVES: Patients treated by (131)I may require blood sampling in the days following its administration. We investigated the safety of such samples in terms of radioactivity and the possible disturbance of the analyses by these "131I-spiked" samples. METHOD: 1) The radioactivity of blood samples from 131I-treated patients was measured (dose rate, surface activity, total activity) ; 2) The risk for the personnel was subsequently evaluated and ; 3) The interference of this 131I-generated radioactivity on the results of routine automated and IRMA assays was investigated. RESULTS: 1) All RA measures but two were found below the European limits ; 2) Irradiation of personnel was negligible ; 3) The faint radioactivity did not disturb any analyses. CONCLUSION: These data demonstrate the safety that results from the negligible radioactivity in these blood samples.


Assuntos
Contaminação de Medicamentos/prevenção & controle , Poluição Ambiental , Radioisótopos do Iodo/sangue , Recursos Humanos em Hospital , Bócio/radioterapia , Humanos , Hipertireoidismo/radioterapia , Radioisótopos do Iodo/uso terapêutico , Exposição Ocupacional/prevenção & controle , Fatores de Risco , Neoplasias da Glândula Tireoide/radioterapia
3.
Am J Med ; 83(5A): 48-54, 1987 Nov 20.
Artigo em Inglês | MEDLINE | ID: mdl-3120586

RESUMO

The effect of S-adenosyl-L-methionine (SAMe) on human articular osteoarthritic chondrocytes was studied using a thick-layer culture model. Three SAMe concentrations were tested (1, 10, and 100 micrograms/ml). For 10 micrograms/ml, the most efficient dose, a significant rise in the incorporation levels of 35S-sulfate and 3H-serine was observed, as was as an increase in the hexuronic acid content. All the parameters seem to express a more active protein synthesis, particularly for proteoglycans. Under the same conditions, the proliferation rate of chondrocytes does not undergo important variations. These results point to a direct action on the cell metabolism but little is known concerning the mechanism involved.


Assuntos
Cartilagem Articular/efeitos dos fármacos , S-Adenosilmetionina/farmacologia , Cartilagem Articular/citologia , Cartilagem Articular/metabolismo , Células Cultivadas/efeitos dos fármacos , Relação Dose-Resposta a Droga , Ácidos Hexurônicos/metabolismo , Humanos , Proteoglicanas/biossíntese , S-Adenosilmetionina/administração & dosagem , Serina/metabolismo , Sulfatos/metabolismo
4.
J Hypertens ; 19(6): 1029-35, 2001 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-11403350

RESUMO

OBJECTIVE: To audit the performances of the analytes used in the diagnosis of pheochromocytoma and to present a graphical guideline to help the diagnosis. DESIGN: A 5 year retrospective study. SETTINGS: Laboratory and departments of a university hospital. PARTICIPANTS: In-patients, suspected of bearing a pheochromocytoma, were investigated for urinary metanephrines and catecholamines (photometric method) and vanillylmandelic acid, fractionated catecholamines and metanephrines [high pressure liquid chromatography (HPLC) coupled to electrochemical detection (ED)] urinary excretion. MAIN OUTCOME: Patients with a pheochromocytoma (24 out of 2003 patients) were diagnosed by the combination of normetanephrine and metanephrine determination. RESULTS: All analytes but dopamine were significantly elevated in patients with a pheochromocytoma. The area under the receiver operating characteristics (ROC) curves were the highest for total metanephrines, normetanephrine and metanephrine determinations. Because of analytical interferences in the metanephrines determination, the normetanephrine and metanephrine performed better. It is noteworthy that all pheochromocytomas had either normetanephrine or metanephrine levels above their respective optimal threshold (sensitivity 100%). The best optimal threshold performance was reached by the mean of three daily samples. Total or fractionated catecholamines or vanillylmandelic acid were less accurate tools. CONCLUSION: Amongst urinary tests, the combined use of HPLC/ED determination of normetanephrine and metanephrine seems the most effective screening strategy for the diagnosis of pheochromocytoma. The older total metanephrine photometric assay is grieved by analytical interferences.


Assuntos
Neoplasias das Glândulas Suprarrenais/diagnóstico , Neoplasias das Glândulas Suprarrenais/urina , Metanefrina/urina , Normetanefrina/urina , Feocromocitoma/diagnóstico , Feocromocitoma/urina , Adolescente , Adulto , Idoso , Catecolaminas/urina , Cromatografia Líquida de Alta Pressão , Eletroquímica , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Curva ROC , Estudos Retrospectivos , Ácido Vanilmandélico/urina
5.
J Nucl Med ; 24(3): 228-30, 1983 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-6298385

RESUMO

Radionuclide angiography has diagnosed systemic arterialization of the right lung base in a patient presenting with a basal thoracic bruit. The bruit was due to high flow in the systemic artery and development of arteriovenous fistulas, confirmed by TCT scan and contrast aortography. But the parenchyma of the right lung base appeared normally aerated on the radiographic studies, and Xe-133 ventilation scintigraphy was normal. This case was therefore classified as systemic arterialization of lung without sequestration.


Assuntos
Fístula Arteriovenosa/diagnóstico por imagem , Pulmão/irrigação sanguínea , Artéria Pulmonar/diagnóstico por imagem , Adulto , Angiografia , Humanos , Masculino , Cintilografia , Albumina Sérica , Pertecnetato Tc 99m de Sódio , Tecnécio , Agregado de Albumina Marcado com Tecnécio Tc 99m , Tomografia Computadorizada por Raios X , Radioisótopos de Xenônio
6.
J Nucl Med ; 25(1): 68-9, 1984 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-6726423

RESUMO

Ten minutes after an intraperitoneal infusion of Tc-99m sulfur colloid, a gamma camera was used to obtain anterior abdominal views. This visualized a peritoneoscrotal communication in an 80-yr-old patient. He had developed extensive edema of the genitals and lower limbs after about 6 wk of continuous ambulatory peritoneal dialysis. At operation the communication was confirmed and closed. A repeat test verified the success of operation.


Assuntos
Fístula/diagnóstico por imagem , Doenças Peritoneais/diagnóstico por imagem , Escroto/diagnóstico por imagem , Enxofre , Tecnécio , Idoso , Fístula/etiologia , Doenças dos Genitais Masculinos/diagnóstico por imagem , Doenças dos Genitais Masculinos/etiologia , Humanos , Canal Inguinal , Injeções Intraperitoneais , Masculino , Diálise Peritoneal Ambulatorial Contínua/efeitos adversos , Doenças Peritoneais/etiologia , Peritônio , Cintilografia , Enxofre/administração & dosagem , Tecnécio/administração & dosagem , Coloide de Enxofre Marcado com Tecnécio Tc 99m
7.
J Nucl Med ; 26(9): 1029-34, 1985 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-4032043

RESUMO

In a patient with a prior history of cerebral abscess and cerebral ischemia, an unsuccessful perfusion lung scan led to a radionuclide angiocardiogram using an arm vein injection. This showed a total right-to-left (R-L) shunt from the superior vena cava (SVC) to the left atrium. Repeat radionuclide study, through a leg vein, demonstrated a moderate R-L shunt and an interpretable lung scan could be obtained. Catheterization and contrast cineangiogram did not provide the exact diagnosis, the preoperative conclusion being anomalous drainage of the SVC into the left atrium, with atrial septal defect (ASD) and partial anomalous pulmonary venous connection to the SVC. The operative diagnosis was high atrial (sinus venosus) septal defect. This example of major but clinically unsuspected R-L shunt emphasizes the value of performing a perfusion lung scan, preferably in conjunction with radionuclide angiocardiography in patients with a prior history of unexplained cerebral abscess or systemic ischemia. Implications of the site of an ASD on quantitation of L-R shunts by radionuclide methods are also discussed.


Assuntos
Comunicação Interatrial/complicações , Pulmão/diagnóstico por imagem , Veia Cava Superior/anormalidades , Abscesso Encefálico/etiologia , Isquemia Encefálica/etiologia , Cateterismo Cardíaco/métodos , Cineangiografia , Comunicação Interatrial/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Cintilografia , Tecnécio , Veia Cava Superior/diagnóstico por imagem
8.
J Nucl Med ; 40(3): 412-7, 1999 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-10086704

RESUMO

UNLABELLED: The aims of this study were to show the value of captopril renal scintigraphy for detecting a renovascular cause in hypertensive patients with renal failure and to assess the ability to predict the beneficial effect of revascularization on renal function. METHODS: Thirty-eight patients with renal failure (mean glomerular filtration rate = 35 mL/min) underwent renal scintigraphy after injection of 99mTc-mercaptoacetyltriglycine. Baseline scintigraphy was performed, and the test was repeated 24 h later after oral administration of 50 mg captopril given 60 min before the test. RESULTS: In 5 of 6 patients with a renovascular cause for renal failure, and 2 of 3 patients with a probable arterial pathology, scintigraphy had a high probability. The result was indeterminate in the other 2 patients. In 5 of 11 patients with negative arteriography and 14 of 18 patients with probable absence of renovascular pathology, we found a low probability of functional renal artery stenosis. Six revascularization procedures were performed and were predictive of a beneficial effect in 5 patients. Time of peak activity was an effective predictor in each case. CONCLUSION: In hypertensive patients with renal failure, captopril renal scintigraphy can detect hemodynamic dysfunction downstream from a renal artery stenosis and can predict the beneficial effect of revascularization in some cases.


Assuntos
Inibidores da Enzima Conversora de Angiotensina , Anti-Hipertensivos , Captopril , Hipertensão Renovascular/etiologia , Renografia por Radioisótopo , Obstrução da Artéria Renal/diagnóstico por imagem , Insuficiência Renal/complicações , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Taxa de Filtração Glomerular , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Compostos Radiofarmacêuticos , Obstrução da Artéria Renal/complicações , Obstrução da Artéria Renal/cirurgia , Sensibilidade e Especificidade , Tecnécio Tc 99m Mertiatida
9.
J Nucl Med ; 40(5): 868-75, 1999 May.
Artigo em Inglês | MEDLINE | ID: mdl-10319763

RESUMO

UNLABELLED: We have developed a scintillation gas detector to localize electrons emitted by 99mTc. This type of detector allows direct quantification of images and so provides a clear advantage over autoradiographic film. We have optimized the device to give an image spatial resolution that closely approximates that of typical autoradiographic film. To improve this resolution, it was necessary to select only low-energy electrons (2 and 15 keV) and to devise novel detection and localization techniques for the ionizing particles. METHODS: A parallel-plate proportional avalanche chamber is subject to a uniform electrical field and amplifies the number of released electrons through collisions of ionizing particles in the gas mixture. Light emitted by the gas scintillator during the avalanche process is collected by a highly intensified charge coupled device camera. The centroid of each resulting light distribution is calculated, resulting in a quantitative mapping of the sample's activity. Insertion of the sample within the gas volume improves the efficiency and so provides a method that is both very sensitive and linear. RESULTS: We have shown that in a parallel-plate structure, the application of a high electrical field to the surface of the sample and the selection of appropriate light spots, according to their morphology, can overcome localization errors due to the particles' trajectories. We have obtained a resolution of the order of 30 microm, using electrons from 99mTc. CONCLUSION: This detection technique allows considerable improvement in image resolution. This "electron camera" is a serious rival to existing autoradiographic techniques, because it provides certain other advantages, including direct quantification, linearity, high dynamic range and low noise levels. Thus, new perspectives are made available in quantitative double tracer autoradiography, because electrons can be selected for imaging as a function of their energy.


Assuntos
Tecnécio , Animais , Autorradiografia/instrumentação , Elétrons , Rim/diagnóstico por imagem , Coelhos , Cintilografia , Contagem de Cintilação/instrumentação
10.
J Nucl Med ; 25(11): 1167-74, 1984 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-6333492

RESUMO

We describe a quantitative method that measures segmental motion of the left ventricle, using tomographic slices obtained by gated single photon emission tomography (GSPECT). These slices contain the major axis of the left ventricle and are presumed to show wall motion directed towards a center of contraction. Values of parameters describing segmental wall motion in GSPECT were obtained from 61 patients, who received a left cardiac catheterization 1 hr later. These values were compared with results of similar calculations applied to data from contrast ventriculography. We conclude that GSPECT allows a detailed and quantitative, noninvasive study of wall motion of all left ventricular segments, with high inter- and intraobserver reproducibility.


Assuntos
Coração/diagnóstico por imagem , Tomografia Computadorizada de Emissão , Angiocardiografia , Humanos , Contração Miocárdica , Volume Sistólico
11.
J Nucl Med ; 37(5): 863-8, 1996 May.
Artigo em Inglês | MEDLINE | ID: mdl-8965165

RESUMO

UNLABELLED: Indium-111-oxinate-labeled granulocytes have been used in vivo for several years for the detection of abscesses. Technetium-99-m-hexamethylpropyleneamine oxime (99mTc-HMPAO) labeling has more recently been described. METHODS: The influence of radiolabeling by both radiotracers on adhesion glycoprotein CD11b quantification was studied in quiescent and formyl-methionylleucylphenylalanine (fMLP)-activated neutrophils (PMN). Adhesion was assessed on human umbilical endothelial cells (HUVEC) as well as the repercussion of the granulocyte labeling on HUVEC viability (neutral red) and metabolic activity (MTT). Chemotaxis of PMN was evaluated by measuring migration under agarose with fMLP as chemoattractant. We also measured phagocytosis and the production of hydrogen peroxide induced by staphylococcus aureus. RESULTS: Whereas whole functional integrity is maintained after labeling, most of the functions (CD11b expression, adhesion, HUVEC metabolic activity) are up-regulated while chemotaxis is decreased in the presence of both radiotracers. Indium-111-oxinate induces larger alterations than 99mTc-HMPAO. CONCLUSION: These data were obtained in normal volunteers. In patients, alterations due to the in vitro labeling procedure, in addition to potential functional alterations caused by the underlying pathology, should be taken into account during image interpretation.


Assuntos
Radioisótopos de Índio , Neutrófilos , Compostos Organometálicos , Compostos de Organotecnécio , Oximas , Oxiquinolina/análogos & derivados , Células Cultivadas , Quimiotaxia de Leucócito , Endotélio Vascular/citologia , Feminino , Humanos , Peróxido de Hidrogênio/metabolismo , Marcação por Isótopo , Ativação Linfocitária , Antígeno de Macrófago 1/metabolismo , Masculino , Neutrófilos/fisiologia , Fagocitose , Explosão Respiratória , Tecnécio Tc 99m Exametazima , Regulação para Cima
12.
Eur J Endocrinol ; 141(2): 117-21, 1999 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-10427153

RESUMO

The best approach to radioiodine dose selection in the treatment of Graves' hyperthyroidism remains highly controversial. The formula to calculate the individual dose of (131)I to be delivered has been used for half a century and takes into account the thyroid mass, the effective half-life and the maximum uptake of (131)I. The objective of the present study was to evaluate the accuracy of this formula by determining the relationship between the administered dose of (131)I calculated to deliver a target dose of 50Gy to the thyroid and the actual exact organ dose. We further analyzed if therapeutic success, defined by euthyroidism following the individually calculated dose, can be predicted by different pretreatment parameters and particularly by organ dose. One hundred patients with a first episode of Graves' disease and who had received optimal thyroid irradiation after precise dosimetry were retrospectively reviewed. The patients were categorized according to their thyroid function (plasma free thyroxine (T(4)) serum concentration) as eu-, hyper- or hypothyroid during and 1 year after treatment. The relationship between the administered dose and organ dose was assessed by simple regression. We compared free T(4), free tri-iodothyronine, thyroid weight, the number of patients with antithyroperoxidase antibodies and TSH receptor autoantibodies, 24h urinary iodine excretion, (131)I uptake, and the exact dose of (131)I delivered to the thyroid as pretreatment variables. Although we found a correlation between administered dose (mCi) and organ dose (Gy) (r=0.3, P=0.003), the mean coefficient of variation for organ dose was 45%. Individualized radioiodine therapy enabled euthyroidism in 26% of patients and failed in 74% of patients (33% had persistent or recurrent hyperthyroidism and 41% permanent hypothyroidism). (131)I uptake was significantly higher in the hyperthyroidism group in comparison with the euthyroid group. However, organ dose and other pretreatment variables did not differ among the three groups. In conclusion, these results confirm the low performance of individual dosimetry using what are established ratios, since the delivered dose to the gland, although correlated to the intended dose, is highly variable. The finding that other usual pretreatment variables are not different between groups, gives little hope for improving the way of calculating the ideal dose of radioiodine. We suggest to those not yet ready to give a standard or an ablative dose for Graves' hyperthyroidism that they abandon this way to calculate the (131)I dose.


Assuntos
Doença de Graves/radioterapia , Radioisótopos do Iodo/uso terapêutico , Adulto , Análise de Variância , Feminino , Doença de Graves/sangue , Humanos , Masculino , Pessoa de Meia-Idade , Dosagem Radioterapêutica , Estudos Retrospectivos , Glândula Tireoide/efeitos da radiação , Hormônios Tireóideos/sangue , Resultado do Tratamento
13.
Invest Radiol ; 34(3): 176-80, 1999 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-10084659

RESUMO

RATIONALE AND OBJECTIVES: Times of acquisition, mean velocities, mean flows, and their respective standard deviations provided by segmented and nonsegmented flow quantifications (FQ) were compared in the main portal veins of ten healthy adults. METHODS: The segmented FQ performed five phase-encoding lines per segment. The authors successively applied the two electrocardiogram-triggered techniques in the same slice perpendicular to the portal flow direction. Their measurements were compared in particular by means of the statistical analysis proposed by Bland and Altman. RESULTS: The segmented 5 FQ reduced the acquisition time by two compared with the nonsegmented FQ. The mean velocity and mean flow values of the two techniques were not significantly different. The standard deviations were similar. CONCLUSIONS: The segmented 5 FQ showed its major advantage in the portal vein: the acquisition time was reduced without any loss of accuracy or any uncertainty enhancement.


Assuntos
Velocidade do Fluxo Sanguíneo/fisiologia , Angiografia por Ressonância Magnética/métodos , Veia Porta/fisiologia , Adulto , Humanos , Aumento da Imagem , Masculino , Veia Porta/anatomia & histologia
14.
Biomaterials ; 12(3): 313-9, 1991 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-1854899

RESUMO

Elastin fibres or elastin solubilized peptides associated with type III collagen, under physiological conditions, to form a gel-like substance. The gel cohesion could be markedly improved either by desiccation process (gently air-dried rather than lyophilized) or by addition of adhesive connective proteins such as fibronectin, laminin and type IV collagen. They conferred to the material the composition and the structural appearance of typical basement membrane-like structure. Their properties enable us to investigate the biomaterial in several domains.


Assuntos
Materiais Biocompatíveis , Colágeno/química , Elastina/química , Adesividade , Prótese Vascular , Colágeno/ultraestrutura , Elastina/ultraestrutura , Géis/química , Concentração de Íons de Hidrogênio , Teste de Materiais , Microscopia Eletrônica , Microscopia Eletrônica de Varredura
15.
Biomaterials ; 12(5): 493-6, 1991 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-1892985

RESUMO

Microlatex beads of homogenous size were made by polymerization of a mixture of acrylamide/bisacrylamide dispersed in a microemulsion. The microlatex was aggregated by dilution of the microemulsion in acrylamide solutions. The aggregates were then coagulated by polymerization at the interfaces of agarose beads circulating in a capillary tube containing paraffin oil. Biocompatibility was tested on isolated pituitary cells microencapsulated by this procedure.


Assuntos
Acrilamidas/química , Materiais Biocompatíveis , Cápsulas , Hipófise/metabolismo , Sefarose/química , Acrilamida , Acrilamidas/toxicidade , Animais , Células Cultivadas , Emulsões/química , Feminino , Hipófise/efeitos dos fármacos , Polímeros , Prolactina/metabolismo , Ratos , Ratos Endogâmicos , Sefarose/toxicidade
16.
Biomaterials ; 9(1): 62-5, 1988 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-3349123

RESUMO

Heparin-like materials, characterized by a defined superficial density of functional groups which activate antithrombin III (AT III), when in contact with blood specifically inhibit thrombin as soon as it appears. This paper describes an isotopic method to estimate this density and to visualize the distribution of the affinity sites concerned, both directly with AT III labelled with 125Iodine and indirectly with an anti AT III monoclonal antibody labelled with 111Indium.


Assuntos
Antitrombina III , Materiais Biocompatíveis , Heparina , Adsorção , Anticorpos Monoclonais , Imunoensaio , Radioisótopos de Índio , Radioisótopos do Iodo , Poliestirenos
17.
J Appl Physiol (1985) ; 90(6): 2197-202, 2001 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-11356783

RESUMO

We describe a magnetic resonance (MR) imaging method that emphasizes pressure wave velocity to noninvasively assess pulmonary arterial hypertension. Both the blood flow and the corresponding vessel cross-sectional area (CSA) were measured by MR phase mapping in the main pulmonary artery (MPA) in 15 patients. MPA pressures were also measured, in the same patients, by right-side heart catheterization. Two significant relationships were established: 1) between the pressure wave velocity in the MPA and the mean pressure in the MPA (Ppa) writing pressure wave velocity = 9.25 Ppa - 202.51 (r = 0.82) and 2) between the ratio of pressure wave velocity to the systolic blood velocity peak in the MPA (R) and the mean pressure in the MPA writing R = 0.68 Ppa - 4.33 (r = 0.89). Using these relationships, we estimated two pressure values to frame the actual Ppa value in each patient from the present series with a reasonable reliability percentage (87%).


Assuntos
Hipertensão Pulmonar/diagnóstico , Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Pressão do Ar , Algoritmos , Cateterismo Cardíaco , Feminino , Humanos , Hipertensão Pulmonar/fisiopatologia , Masculino , Pessoa de Meia-Idade , Circulação Pulmonar/fisiologia
18.
Regul Pept ; 42(1-2): 51-61, 1992 Nov 20.
Artigo em Inglês | MEDLINE | ID: mdl-1475406

RESUMO

The mechanisms of hypertension during primary hyperaldosteronism and Cushing's syndrome are not completely understood. An enhanced vascular sensitivity to noradrenaline has been described in both situations. Neuropeptide Y (NPY) induces direct vasoconstriction and potentiates the action of noradrenaline. Sodium retention and dexamethasone have been shown to increase circulating NPY levels in animals and the expression of NPY in neuroendocrine cells. In order to determine if NPY could be involved in the enhanced vascular sensitivity to noradrenaline associated with adrenocortical hyperactivity, we measured plasma NPY in patients with Cushing's syndrome (n = 26) and primary hyperaldosteronism (n = 15) and compared it with that of hypertensive patients with pheochromocytomas (n = 13) or essential hypertension (n = 51) and with normotensive controls (n = 47). The concentration of NPY-Like immunoreactivity (NPY-Li) (mean +/- S.E.) in controls was 39.6 +/- 3.0 pg/ml. Elevated concentrations were found in 77% of the samples collected from pheochromocytoma patients (1180.4 +/- 394.0 pg/ml). NPY-Li levels in patients with essential hypertension (35.0 +/- 2.6 pg/ml), primary hyperaldosteronism (31.3 +/- 3.9 pg/ml) and Cushing's syndrome (33.1 +/- 4.8 pg/ml) were not different from that of controls. NPY-Li levels in hypertensive and normotensive patients with Cushing's syndrome were similar (38.5 +/- 7.5 vs 24.2 +/- 3.7 pg/ml). No correlation was found between the NPY-Li level and the mean blood pressure at the time of sampling. Our results suggest that NPY is unlikely to be involved in the pathogenesis of hypertension associated with primary hyperaldosteronism and Cushing's syndrome.


Assuntos
Síndrome de Cushing/sangue , Hiperaldosteronismo/sangue , Hipertensão/sangue , Neuropeptídeo Y/sangue , Adolescente , Neoplasias das Glândulas Suprarrenais/sangue , Neoplasias das Glândulas Suprarrenais/complicações , Neoplasias das Glândulas Suprarrenais/fisiopatologia , Adulto , Idoso , Pressão Sanguínea , Síndrome de Cushing/complicações , Síndrome de Cushing/fisiopatologia , Feminino , Humanos , Hiperaldosteronismo/complicações , Hiperaldosteronismo/fisiopatologia , Hipertensão/etiologia , Hipertensão/fisiopatologia , Masculino , Pessoa de Meia-Idade , Feocromocitoma/sangue , Feocromocitoma/complicações , Feocromocitoma/fisiopatologia
19.
Nucl Med Biol ; 20(7): 849-55, 1993 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-8241997

RESUMO

Biodistribution analysis using [125I]Fab-6F3 specific to link proteins from human articular cartilage performed in rats by autoradiography showed a high concentration of radioactivity in all cartilaginous tissues. Preliminary immunoscintigraphic assays were performed in rabbits. Front and side view images of whole animals exhibited high uptake in cartilage tissue of the knee articulation, in the invertebral disk and the humeral head. This fixation was still detected 24 h post-injection, although high washout of radioactivity was observed.


Assuntos
Anticorpos Monoclonais , Cartilagem/diagnóstico por imagem , Proteínas da Matriz Extracelular , Proteínas/imunologia , Proteoglicanas/imunologia , Radioimunodetecção , Animais , Anticorpos Monoclonais/metabolismo , Autorradiografia , Fragmentos Fab das Imunoglobulinas , Masculino , Coelhos , Ratos , Ratos Wistar
20.
Neurosurgery ; 30(3): 396-401, 1992 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-1620304

RESUMO

Dural substitutes must provide immediate restitution of a membranous covering for the brain without inducing any adverse reaction in the host or provoking adhesions to underlying nervous tissues. Ideally, the material should disappear completely and be replaced by tissues similar to the dura mater. In this study, parietal dural defects were created in 12 beagle dogs and closed with a vicryl mesh prosthesis made watertight by a film of bovine collagen. Clinical and biological tolerances were satisfactory. There was one case of early local infection. Gross and microscopic examinations performed between 7 days and 9 months after implantation showed degradation of the prosthetic mesh and connective tissue growth into the implant mimicking dura mater as early as 15 days after implantation. There was no attendant inflammatory reaction or cortical adhesions or other adverse reactions. The authors conclude that collagen-embedded vicryl mesh provides satisfactory biological function and compatibility when used as a substitute for dura mater in the dog.


Assuntos
Colágeno , Dura-Máter , Poliglactina 910 , Telas Cirúrgicas , Animais , Materiais Biocompatíveis , Cães , Dura-Máter/patologia , Dura-Máter/cirurgia , Reação a Corpo Estranho/patologia , Crânio/cirurgia , Infecção da Ferida Cirúrgica , Adesivos Teciduais
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA