RESUMO
BACKGROUND: Cardiac intensive care units (CICUs) serve medically complex patients with multiorgan dysfunction. Whether a CICU that is staffed full time by heart failure (HF) specialists is associated with decreased mortality is unclear. METHODS AND RESULTS: A retrospective review of consecutive CICU admissions from January 1, 2012, to December 31, 2016, was performed. In January 2014, the CICU changed from an open unit staffed by any cardiologist to a closed unit managed by HF specialists. Patients' baseline characteristics were determined, and a multivariate regression analysis was performed to ascertain mortality rates in the CICU. Baseline severity of illness was higher in the closed/HF specialist CICU model (P< 0.001). Death occurred in 101 of 1185 patients admitted to the CICU (8.5%) in the open-unit model and in 139 of 2163 patients (6.4%) admitted to the closed/HF specialist model (absolute risk reduction 2.1%, 95% confidence interval [CI] 0.1-4.0%; Pâ¯=â¯0.01). The transition from an open to a closed/HF specialist model was associated with a lower overall CICU mortality rate (odds ratio [OR] 0.63; 95% CI 0.43-0.93). Prespecified interaction with a mechanical circulatory support device and unit model showed that treatment with such a device was associated with lower mortality rates in the closed/HF specialist model of a CICU (OR 0.6; 95% CI 0.18-0.78; P for interaction <0.01). CONCLUSION: Transition to a closed unit model staffed by a dedicated HF specialist is associated with lower CICU mortality rates.
Assuntos
Unidades de Cuidados Coronarianos , Insuficiência Cardíaca , Insuficiência Cardíaca/terapia , Mortalidade Hospitalar , Humanos , Unidades de Terapia Intensiva , Estudos Retrospectivos , Recursos HumanosRESUMO
BACKGROUND: The HeartMate II (HMII) Left Ventricular Assist System (Thoratec Corporation, Pleasanton, CA, USA), an axial continuous-flow left ventricular assist device (LVAD), has been approved for use in bridge-to-transplant patients and is under investigation for destination therapy. To avoid device-related thromboembolic complications, antiplatelet, and anticoagulation therapy are routinely administered. A worrisome frequency of gastrointestinal (GI) bleeding events has been observed. METHODS: A retrospective review of all 33 patients undergoing long-term LVAD implantation between June 1, 2006 and July 31, 2008 at our institution for any indication was conducted. Anticoagulation consisted of heparin (intravenous or subcutaneous) followed by transition to Coumadin therapy to a target INR of two to three. Antiplatelet therapy consisted of low-dose aspirin and dipyridamole. RESULTS: Twenty patients received the HMII and 13 patients received other devices. Eight (40%) HMII recipients suffered at least one episode of GI bleeding while no GI bleeding occurred in recipients of other devices (p = 0.012). Of 17 total bleeding episodes, no definitive source could be identified in 11 instances (65%). CONCLUSIONS: Although definitive source identification remains elusive, we believe that the majority of bleeding arises in the small bowel, possibly due to angiodysplasias, similar to the pathophysiology encountered in patients with aortic stenosis and GI bleeding. As we move toward wider use of the HMII and other axial continuous-flow devices in both bridge-to-transplant patients and for destination therapy, more studies will be necessary to understand the mechanisms of this obscure GI bleeding and develop treatment strategies to minimize its development.