Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 146
Filtrar
1.
Catheter Cardiovasc Interv ; 103(6): 934-942, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38584522

RESUMO

BACKGROUND: Transcatheter closure of the patent ductus arteriosus (PDA) in premature infants is currently dependent on fluoroscopic guidance and transportation to the catheterization laboratory. AIM: We describe a new echocardiographically guided technique to allow our team to move to the bedside at the neonatal intensive care unit (NICU) of the referring center for percutaneous treatment of PDA in premature infants. METHODS: This is a single-center, retrospective, primarily descriptive analysis. Clinical details about the procedure, its outcomes, and complications were collected. RESULTS: Fifty-eight neonates with a median weight of 1110 g (range 730-2800) and postnatal age of 28 days (range 9-95) underwent percutaneous PDA closure. Five of them were treated in our center with ultrasound guidance only and the other 53 in 18 different neonatology units in 12 towns. The median duration of the procedure was 40 min (range 20-195 min). There were no procedural deaths. There was one residual shunt for 3 weeks, in all other patients the duct closed completely in the first few hours after the intervention. In one patient the procedure had to be interrupted because of a pericardial effusion which had to be drained, the PDA was closed successfully interventionally 5 days later. One device-related aortic coarctation had to be stented. One embolization and one late migration occurred and required treatment. CONCLUSIONS: Echocardiographically guided transcatheter closure of the PDA in prematures was repeatedly possible and allowed that the procedure is performed at the bedside at the NICU with an acceptable rate of complications.


Assuntos
Cateterismo Cardíaco , Permeabilidade do Canal Arterial , Ultrassonografia de Intervenção , Humanos , Permeabilidade do Canal Arterial/terapia , Permeabilidade do Canal Arterial/diagnóstico por imagem , Permeabilidade do Canal Arterial/fisiopatologia , Recém-Nascido , Estudos Retrospectivos , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Resultado do Tratamento , Idade Gestacional , Valor Preditivo dos Testes , Masculino , Feminino , Fatores de Tempo , Índice de Gravidade de Doença , Recém-Nascido Prematuro , Lactente Extremamente Prematuro , Unidades de Terapia Intensiva Neonatal , Sistemas Automatizados de Assistência Junto ao Leito , Testes Imediatos , Dispositivo para Oclusão Septal , Lactente
2.
Artigo em Inglês | MEDLINE | ID: mdl-39087728

RESUMO

BACKGROUND: Transcatheter tricuspid valve-in-valve (ViV) replacement has yielded good hemodynamic outcomes in the treatment of dysfunctional bioprosthetic valves (BPVs). Intentional fracture of certain rigid BPV frames, if feasible, allows a larger implanted valve when compared with implant into an unfractured BPV. There remains limited data on the feasibility of tricuspid valve frame fracture. AIMS: Evaluate the feasibility of transcatheter tricuspid ViV replatement with fracture of the underlying BPV ring. METHODS: An international multicenter registry of tricuspid ViV replacement with intentional tricuspid valve frame fracture was created. Demographic data along with procedural characteristics, outcomes, and follow-up data were collected. Comparison was made to the pre- and post-ViV replacement with fracture of the tricuspid valve frame conditions. RESULTS: Ten patients from six centers were included with a median age and weight of 29 years and 67.3 kg respectively. Tricuspid valve frame fracture was performed using a median balloon diameter 3 mm (IQR 3-5) larger than the true inner diameter (ID). The final ID was a mean of 1.5 mm (95% CI: 0.35, 2.64: p < 0.05), and median 1.1 mm (0.5, 2.1) larger than the reported true ID of the surgical BPV after ViV replacement. The mean tricuspid inflow gradient by echocardiogram decreased by 6.65 mmHg (95% CI: 4.14, 9.15: p < 0.001). All procedures were without complication, specifically there was no heart block, pericardial effusion, or right coronary disruption. CONCLUSION: Intentional tricuspid valve frame fracture with tricuspid ViV replacement is feasible and can increase the valve orifice potentially reducing the risk of ViV patient prosthesis mismatch and is not associated with significant complications.

3.
Pneumologie ; 78(8): 566-577, 2024 Aug.
Artigo em Alemão | MEDLINE | ID: mdl-38788761

RESUMO

The number of adults with congenital heart defects (CHD) is steadily rising and amounts to approximately 360,000 in Germany. CHD is often associated with pulmonary hypertension (PH), which may develop early in untreated CHD. Despite timely treatment of CHD, PH not infrequently persists or recurs in older age and is associated with significant morbidity and mortality.The revised European Society of Cardiology/European Respiratory Society 2022 guidelines for the diagnosis and treatment of PH represent a significant contribution to the optimized care of those affected. However, the topic of "adults with congenital heart disease" is addressed only relatively superficial in these guidelines. Therefore, in the present article, this topic is commented in detail from the perspective of congenital cardiology.


Assuntos
Cardiopatias Congênitas , Hipertensão Pulmonar , Guias de Prática Clínica como Assunto , Humanos , Hipertensão Pulmonar/terapia , Hipertensão Pulmonar/diagnóstico , Hipertensão Pulmonar/etiologia , Cardiopatias Congênitas/complicações , Feminino , Gravidez , Alemanha , Adulto , Cuidados Críticos/métodos , Cuidados Críticos/normas , Transplante de Órgãos , Complicações Cardiovasculares na Gravidez/terapia , Cardiologia/normas , Masculino , Disfunção Ventricular Esquerda/etiologia , Disfunção Ventricular Esquerda/diagnóstico
4.
Acta Paediatr ; 112(11): 2440-2448, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37485905

RESUMO

Several high-risk medical devices for children have become unavailable in the European Union (EU), since requirements and costs for device certification increased markedly due to the EU Medical Device Regulation. The EU-funded CORE-MD project held a workshop in January 2023 with experts from various child health specialties, representatives of European paediatric associations, a regulatory authority and the European Commission Directorate General Health and Food Safety. A virtual follow-up meeting took place in March 2023. We developed recommendations for investigation of high-risk medical devices for children building on participants' expertise and results of a scoping review of clinical trials on high-risk medical devices in children. Approaches for evaluating and certifying high-risk medical devices for market introduction are proposed.

5.
Pneumologie ; 77(11): 956-961, 2023 Nov.
Artigo em Alemão | MEDLINE | ID: mdl-37963485

RESUMO

The number of adults with congenital heart disease (CHD) is steadily rising and amounts to approximately 360,000 in Germany. CHD is often associated with pulmonary arterial hypertension (PAH), which may develop early in untreated CHD. Despite timely treatment of CHD, PAH often persists or recurs in older age and is associated with significant morbidity and mortality.The revised European Society of Cardiology/European Respiratory Society 2022 guidelines for the diagnosis and treatment of PH represent a significant contribution to the optimized care of those affected. However, the topic of "adults with congenital heart defects" is addressed only relatively superficially in these guidelines. Therefore, this article addresses the perspective of congenital cardiology in greater depth.


Assuntos
Cardiologia , Cardiopatias Congênitas , Hipertensão Arterial Pulmonar , Adulto , Humanos , Hipertensão Arterial Pulmonar/complicações , Hipertensão Arterial Pulmonar/diagnóstico , Cardiopatias Congênitas/complicações , Cardiopatias Congênitas/diagnóstico , Cardiopatias Congênitas/terapia , Alemanha
6.
Catheter Cardiovasc Interv ; 99(7): 2054-2063, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35395135

RESUMO

BACKGROUND: Covered stents perform similar to surgically implanted conduits, although the stents work inside of vessels. We present a computed tomography (CT)-based workflow for the implantation of covered stents as extravascular conduits. METHODS: We selected three different use cases: 1. Connecting a left-sided partially anomalous drainage of a pulmonary vein to the left atrium. 2. Bypassing an outgrown Dacron conduit in aortic recoarctation. 3. Re-directing hepatic venous blood to the left lung in a Fontan patient with heterotaxy, connecting the innominate vein to the right pulmonary artery like a right-sided cavopulmonary connection. By postprocessing and analyzing CT scans for planning and by the use of long needles under biplane fluoroscopy for the realization of the procedure, we projected and performed the exit of a long needle out of a vessel, the re-entering of a target vessel, and the bridging of the extravascular distance by implantation of covered stents. RESULTS: In all three cases, the covered stents were placed successfully, connecting vessels of 15-50 mm distance from each other with very good hemodynamic results. In one case, two stents were placed consecutively, overlapping each other to accomplish an exact fitting at the connection sites to the native vessels.


Assuntos
Cardiopatias Congênitas , Veias Pulmonares , Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/cirurgia , Humanos , Artéria Pulmonar/diagnóstico por imagem , Artéria Pulmonar/cirurgia , Stents , Tomografia Computadorizada por Raios X , Resultado do Tratamento
7.
Catheter Cardiovasc Interv ; 95(7): 1305-1309, 2020 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-32043804

RESUMO

We report on two patients who received a transcatheter cavopulmonary connection by a needle puncture under deep conscious sedation. In both patients, the vessel-to-vessel connection was achieved by a venous access into the superior caval vein and direct needle puncture of the pulmonary artery. The two cavopulmonary anastomoses were held open by a covered stent and a bare-metal stent, respectively.


Assuntos
Cateterismo Cardíaco , Técnica de Fontan/métodos , Cardiopatias Congênitas/terapia , Artéria Pulmonar , Veia Cava Superior , Adolescente , Cateterismo Cardíaco/instrumentação , Sedação Consciente , Técnica de Fontan/instrumentação , Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/fisiopatologia , Hemodinâmica , Humanos , Pessoa de Meia-Idade , Agulhas , Artéria Pulmonar/diagnóstico por imagem , Artéria Pulmonar/fisiopatologia , Punções , Recuperação de Função Fisiológica , Stents , Resultado do Tratamento , Veia Cava Superior/diagnóstico por imagem , Veia Cava Superior/fisiopatologia
8.
Pediatr Cardiol ; 41(2): 382-388, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31858202

RESUMO

Percutaneous pulmonary valve replacement (PPVI) in native or patched right ventricular outflow tract (RVOT) has proven to be feasible. The procedure is highly dependent on the size of the RVOT. Several methods exist to evaluate the size of the RVOT by cardiovascular magnetic resonance (CMR). We evaluated different CMR modalities for measuring RVOT diameters. Thirty-one consecutive patients with native or patched RVOT were retrospectively evaluated. CMR was part of follow-up of patients with corrected Tetralogy of Fallot or pulmonary stenosis with significant pulmonary regurgitation (PR). CMR included 3D-SSFP whole-heart in systole, diastole, and contrast-enhanced MR angiography (ceMRA). Diameters of the RVOT were assessed by the three sequences. Additionally, in patients who underwent cardiac catheterization (n = 11) for PPVI, vessel diameters assessed by cine-angiography were compared to CMR. Systolic diameters of RVOT were significantly larger compared to the diameters taken in diastole and ceMRA (median difference 5.0 mm and 3.8 mm). Diastolic and ceMRA diameters did not differ significantly. CMR diameters taken in systole showed no statistical difference to systolic diameters taken by cine-angiography, while diastolic and ceMRA diameters were significantly smaller. PPVI was feasible to a maximal CMR diameter of 31 mm measured by SSFP whole-heart sequence in systole. Absolute diameters of native RVOT differ depending on the CMR sequence and timing of acquisition (systolic vs diastolic gating). Diameters taken during heart catheterization by cine-angiography best correlate to systolic CMR values. Data may help to select RVOTs suitable for PPVI.


Assuntos
Técnicas de Imagem Cardíaca/métodos , Implante de Prótese de Valva Cardíaca/métodos , Ventrículos do Coração/patologia , Imageamento por Ressonância Magnética/métodos , Adolescente , Adulto , Cateterismo Cardíaco/métodos , Feminino , Ventrículos do Coração/diagnóstico por imagem , Humanos , Masculino , Insuficiência da Valva Pulmonar/cirurgia , Estenose da Valva Pulmonar/cirurgia , Estudos Retrospectivos , Tetralogia de Fallot/cirurgia
9.
Cardiol Young ; 30(6): 896-898, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32391745

RESUMO

Vessel occlusion is a frequently used procedure to close congenital or acquired collaterals or communications. We report two cases of successful vessel closure, in small infants with CHD, using the Azur CX Peripheral Coil System. The low profile of the device, the controlled delivery of the coils, and the delivery through a microcatheter make it particularly interesting for the occlusion of highly tortuous vessels in children.


Assuntos
Embolização Terapêutica/instrumentação , Embolização Terapêutica/métodos , Cardiopatias Congênitas/terapia , Fístula Vascular/terapia , Angiografia Coronária , Desenho de Equipamento , Cardiopatias Congênitas/diagnóstico por imagem , Humanos , Lactente , Masculino , Resultado do Tratamento , Fístula Vascular/diagnóstico por imagem
10.
Cardiol Young ; 30(10): 1458-1461, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32778192

RESUMO

BACKGROUND: Catheterization in small children should be performed with the lowest diameter introducer sheaths to prevent permanent vessel damage. The objective of this study is to evaluate the clinical safety and efficacy of the Glidesheath Slender in small children. METHODS AND RESULTS: We present a group of 52 patients (male: n = 36) with median age 118.5 days (min. 3; max. 1302), median weight: 5.3 kg (min. 1.4; max. 14.0), median height: 60.5 cm (min. 39; max. 102), and median body surface area 0.28 m2 (min. 0.12; max. 0.63) in whom percutaneous catheter interventions (n = 55) were performed via a Glidesheath Slender. In 49 children, the intervention was performed from femoral access (artery n = 35; vein n = 14) in 2 from the axillary arterial access and in 1 from the jugular venous access. In all patients, the vessel access was obtained under ultrasound guidance. After the catheterization, the pulse on the peripheral arteries (posterior tibial artery or radial artery) was palpable in all patients, and no signs for vessel dysfunction were present. CONCLUSION: The Glidesheath Slender effectively reduces the outer sheath diameter for various types of interventions in small children by one French, reducing the risk of vessel complications (stenosis, occlusion). Interventions via Glidesheath Slender in small patients are safe and feasible and extend the transcatheter possibilities in small children with congenital heart diseases.


Assuntos
Intervenção Coronária Percutânea , Idoso de 80 Anos ou mais , Cateteres Cardíacos , Cateterismo , Criança , Artéria Femoral , Humanos , Masculino , Artéria Radial/cirurgia , Resultado do Tratamento
11.
Catheter Cardiovasc Interv ; 93(2): 316-321, 2019 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-30719850

RESUMO

AIMS: The aim of this study was to compare the efficacy and safety of the Occlutech Figulla Flex II Occluder (OFFII) with the Amplatzer Septal Occluder (ASO) in patients > 8kg undergoing transcatheter ASD closure. METHODS AND RESULTS: Randomized, controlled, multi-center prospective clinical trial with randomization 2:1 in favor of the OFFII. Primary efficacy endpoint was the rate of successful device placement and defect closure without major complications at hospital discharge. All data were assessed through a core laboratory. Interim analysis was performed when 70% of the patients were treated to evaluate for noninferiority. From a total of 176 randomized subjects, interim analysis was performed on the first 158 patients (65.2% female) (107 OFFII/51 ASO) undergoing device closure at a median weight of 42 kg (range 13-125 kg). Seventy-six percent (120 patients) completed 6-month follow-up. Successful device placement (first attempt) was achieved in 99.1% of the OFF group vs 90.2% of the ASO group (P < 0.05). Early efficacy success was achieved in 94.4% of the OFFII group vs 90.2% of the ASO group (P < 0.001). The incidence of major complications was 5.6% for the OFFII group compared to 9.8% for the ASO. CONCLUSIONS: The OFFII device was not inferior to the ASO with less complications and greater efficacy than the ASO.


Assuntos
Cateterismo Cardíaco/instrumentação , Comunicação Interatrial/terapia , Dispositivo para Oclusão Septal , Adolescente , Adulto , Idoso , Cateterismo Cardíaco/efeitos adversos , Criança , Pré-Escolar , Feminino , França , Alemanha , Comunicação Interatrial/diagnóstico por imagem , Comunicação Interatrial/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem
12.
Catheter Cardiovasc Interv ; 94(4): 607-617, 2019 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-31419019

RESUMO

OBJECTIVES: To investigate whether age and valve size at implant contribute to outcomes after Melody transcatheter pulmonary valve replacement (TPVR). BACKGROUND: Patient age and valve size at implant contribute to longevity of surgical pulmonary valves. METHODS: All patients discharged with a Melody valve in the pulmonary position, as part of three prospective Melody valve multicenter studies, comprised the study cohort. Acute and time-related outcomes were analyzed according to age: children (≤12 years), adolescents (13-18 years), young adults (19-29 years), and older adults (≥30 years). RESULTS: Successful Melody valve implantation occurred in 49 children, 107 adolescents, 96 young adults, and 57 older adults. Pediatric patients (≤18 years) were more likely to have TPVR for conduit stenosis than adults (62% vs. 44%); children had the smallest conduits. After TPVR, pediatric and adult patients had similar decreases in right ventricular (RV) size by MRI, but adults had improved percentage predicted peak VO2 (58% preimplant to 64% postimplant, p = .02) and FEV1 (69% pre to 71% post, p = .005). Younger age was associated with shorter freedom from RVOT dysfunction, reintervention, and explant. Children had the shortest freedom from endocarditis (p = .041), but all other groups had 5-year freedom from endocarditis of ≥90%. CONCLUSIONS: Younger age was associated with shorter time to RVOT dysfunction, reintervention, and explant after Melody TPVR. Patients ≥13 years of age were at low risk for endocarditis and explant to 5 years. A better understanding of time-related outcomes by age will aid in the comparison of therapeutic options for TPVR candidates. CLINICAL TRIAL REGISTRATION: https://clinicaltrials.gov/ct2/show/NCT00740870 (NCT00740870), https://clinicaltrials.gov/ct2/show/NCT01186692 (NCT01186692), and https://clinicaltrials.gov/ct2/show/NCT00688571 (NCT00688571).


Assuntos
Cateterismo Cardíaco/instrumentação , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Valva Pulmonar/cirurgia , Adolescente , Fatores Etários , Canadá , Cateterismo Cardíaco/efeitos adversos , Criança , Ensaios Clínicos como Assunto , Bases de Dados Factuais , Remoção de Dispositivo , Endocardite/etiologia , Endocardite/fisiopatologia , Endocardite/cirurgia , Europa (Continente) , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Hemodinâmica , Humanos , Masculino , Intervalo Livre de Progressão , Desenho de Prótese , Falha de Prótese , Valva Pulmonar/diagnóstico por imagem , Valva Pulmonar/fisiopatologia , Reoperação , Fatores de Risco , Fatores de Tempo , Estados Unidos , Obstrução do Fluxo Ventricular Externo/etiologia , Obstrução do Fluxo Ventricular Externo/fisiopatologia , Obstrução do Fluxo Ventricular Externo/cirurgia , Adulto Jovem
13.
Cardiol Young ; 29(6): 837-839, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-31169113

RESUMO

A neonate presented with signs of heart failure early after a Norwood procedure, due to increase of aortic and mitral valve regurgitation. Because repeated surgery was considered risky, we closed the aortic valve by catheter intervention with an Amplatzer Duct Occluder. Aortic regurgitation was abolished almost completely and the child improved. Unfortunately, 2 weeks after discharge, the patient died suddenly.


Assuntos
Insuficiência da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Síndrome do Coração Esquerdo Hipoplásico/cirurgia , Procedimentos de Norwood/efeitos adversos , Complicações Pós-Operatórias , Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/diagnóstico , Insuficiência da Valva Aórtica/etiologia , Ecocardiografia , Evolução Fatal , Seguimentos , Humanos , Recém-Nascido , Masculino , Reoperação , Fatores de Tempo
14.
Cardiol Young ; 29(10): 1287-1289, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31486353

RESUMO

We report on a 12-year-old girl with Ebstein's anomaly after a unidirectional Glenn procedure with surgical ligation of the proximal right pulmonary artery, who suffered from significant central cyanosis caused by multiple arterio-venous fistulas in the right lung. The continuity between the right pulmonary artery and the pulmonary trunk was restored with the use of radiofrequency perforation and consecutive covered stent implantation.


Assuntos
Fístula Arteriovenosa/diagnóstico , Anomalia de Ebstein/cirurgia , Técnica de Fontan/métodos , Veias Hepáticas/cirurgia , Artéria Pulmonar/anormalidades , Veias Pulmonares/anormalidades , Angiografia , Implante de Prótese Vascular/métodos , Criança , Feminino , Seguimentos , Veias Hepáticas/diagnóstico por imagem , Humanos , Fatores de Tempo
15.
Cardiol Young ; 28(5): 753-755, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29409567

RESUMO

We report on successful endovascular retrieval of an accidentally flared Melody valve in an adult patient with an indication for percutaneous pulmonary valve implantation. The Melody valve was removed through a 24 F sheath, introduced via the right jugular vein, and the urgent open-heart surgery was avoided.


Assuntos
Bioprótese/efeitos adversos , Remoção de Dispositivo/métodos , Próteses Valvulares Cardíacas/efeitos adversos , Estenose da Valva Pulmonar/cirurgia , Adulto , Cateterismo Cardíaco , Feminino , Humanos , Desenho de Prótese , Falha de Prótese , Valva Pulmonar/cirurgia , Estenose da Valva Pulmonar/diagnóstico , Reoperação , Tomografia Computadorizada por Raios X
16.
Cardiol Young ; 28(7): 955-960, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29779498

RESUMO

OBJECTIVES: This study aimed to develop a method for retrieval of the new meshed nitinol atrial septal defect occluders - Ceraflex and Occlutech. BACKGROUND: The newly developed atrial septal defect occluders have potential benefits considering implantation, but concerns regarding their removal in case of embolisation have been raised. METHODS: Over 21 years, 1449 patients underwent interventional atrial septal defect occlusion in our institution. We reviewed the cases of embolisation of the device, developed a strategy for device removal, and tested it on the benchside and in animal tests. RESULTS: In 11 patients (0.8%), the intended atrial septal defect occlusion was complicated by an embolisation of the device. In contrast to the Amplatzer septal occluders, retrieval of Occlutech devices larger than 16 mm with snare techniques was impossible. In benchside tests, this was confirmed and a new method for removal of large meshed devices was developed. This involved the commercially available Maslanka® biopsy forceps. The feasibility of this technique in vivo was tested in a pig model. During animal tests, using the Maslanka biopsy forceps it was possible to interventionally retrieve embolised Ceraflex and Occlutech devices of different sizes - 10, 16, 30, and 40 mm - into a 12-F sheath. CONCLUSION: It was impossible to retrieve Occlutech and Ceraflex devices larger than 16 mm into a large sheath in vivo and during benchside tests. However, this was feasible on the bench and in vivo using the Maslanka biopsy forceps even with the largest available devices.


Assuntos
Cateterismo Cardíaco/instrumentação , Remoção de Dispositivo/métodos , Embolia/terapia , Comunicação Interatrial/terapia , Falha de Prótese , Dispositivo para Oclusão Septal , Adolescente , Adulto , Idoso , Angiografia , Animais , Cateterismo Cardíaco/efeitos adversos , Criança , Embolia/etiologia , Feminino , Comunicação Interatrial/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Modelos Animais , Estudo de Prova de Conceito , Desenho de Prótese , Suínos , Resultado do Tratamento , Adulto Jovem
17.
Circulation ; 133(16): 1582-93, 2016 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-26994123

RESUMO

BACKGROUND: Off-label use of transcatheter aortic and pulmonary valve prostheses for tricuspid valve-in-valve implantation (TVIV) within dysfunctional surgical tricuspid valve (TV) bioprostheses has been described in small reports. METHODS AND RESULTS: An international, multicenter registry was developed to collect data on TVIV cases. Patient-related factors, procedural details and outcomes, and follow-up data were analyzed. Valve-in-ring or heterotopic TV implantation procedures were not included. Data were collected on 156 patients with bioprosthetic TV dysfunction who underwent catheterization with planned TVIV. The median age was 40 years, and 71% of patients were in New York Heart Association class III or IV. Among 152 patients in whom TVIV was attempted with a Melody (n=94) or Sapien (n=58) valve, implantation was successful in 150, with few serious complications. After TVIV, both the TV inflow gradient and tricuspid regurgitation grade improved significantly. During follow-up (median, 13.3 months), 22 patients died, 5 within 30 days; all 22 patients were in New York Heart Association class III or IV, and 9 were hospitalized before TVIV. There were 10 TV reinterventions, and 3 other patients had significant recurrent TV dysfunction. At follow-up, 77% of patients were in New York Heart Association class I or II (P<0.001 versus before TVIV). Outcomes did not differ according to surgical valve size or TVIV valve type. CONCLUSIONS: TVIV with commercially available transcatheter prostheses is technically and clinically successful in patients of various ages across a wide range of valve size. Although preimplantation clinical status was associated with outcome, many patients in New York Heart Association class III or IV at baseline improved. TVIV should be considered a viable option for treatment of failing TV bioprostheses.


Assuntos
Bioprótese/tendências , Cateterismo Cardíaco/métodos , Implante de Prótese de Valva Cardíaca/métodos , Internacionalidade , Falha de Prótese/tendências , Insuficiência da Valva Tricúspide/cirurgia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Bioprótese/efeitos adversos , Criança , Pré-Escolar , Feminino , Seguimentos , Humanos , Tempo de Internação/tendências , Masculino , Pessoa de Meia-Idade , Sistema de Registros , Resultado do Tratamento , Insuficiência da Valva Tricúspide/diagnóstico , Adulto Jovem
19.
Catheter Cardiovasc Interv ; 89(2): 298-305, 2017 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-27465501

RESUMO

BACKGROUND: The most common reason for reintervention after a Björk modification of the Fontan procedure, in which the right ventricle (RV) is incorporated into the pulmonary circulation by connecting the right atrial (RA) appendage to the RV directly or with an extra-anatomic graft, is obstruction or regurgitation of the RA-RV connection. Transcatheter implantation of a valved stent is an appealing option for the treatment of RA-RV conduit dysfunction in these patients. In the present study, we assessed early and intermediate results after transcatheter valve implantation within an obstructed or regurgitant RA-RV modified Fontan pathway. METHODS: Through a retrospective multicenter registry, we collected data from 16 patients with a modified Fontan circulation who were treated with percutaneous Melody or Sapien valve implantation for dysfunction of an extra-anatomic RA-RV conduit or valve. RESULTS: All patients had successful and uncomplicated implantation of a Melody (n = 15) or Sapien 3 (n = 1) valve with hemodynamic and, in most cases, clinical improvement. During a median follow-up of 3.3 years, 3 patients died of cardiovascular causes unrelated to the procedure or the valve, and no major valve dysfunction was observed. CONCLUSION: Percutaneous transcatheter valve deployment to treat a dysfunctional RA-RV connection after a Björk modification of the Fontan procedure is a viable alternative to surgery, with low procedural risk, and appears to offer good early and intermediate results.© 2016 Wiley Periodicals, Inc.


Assuntos
Implante de Prótese Vascular , Cateterismo Cardíaco/métodos , Técnica de Fontan/efeitos adversos , Oclusão de Enxerto Vascular/terapia , Cardiopatias Congênitas/cirurgia , Doenças das Valvas Cardíacas/terapia , Implante de Prótese de Valva Cardíaca/métodos , Adulto , Bioprótese , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Canadá , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Europa (Continente) , Feminino , Técnica de Fontan/métodos , Oclusão de Enxerto Vascular/diagnóstico por imagem , Oclusão de Enxerto Vascular/etiologia , Oclusão de Enxerto Vascular/fisiopatologia , Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/fisiopatologia , Doenças das Valvas Cardíacas/diagnóstico por imagem , Doenças das Valvas Cardíacas/etiologia , Doenças das Valvas Cardíacas/fisiopatologia , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Hemodinâmica , Humanos , Masculino , Pessoa de Meia-Idade , América do Norte , Desenho de Prótese , Falha de Prótese , Recuperação de Função Fisiológica , Sistema de Registros , Estudos Retrospectivos , Stents , Fatores de Tempo , Resultado do Tratamento
20.
Catheter Cardiovasc Interv ; 89(2): 280-287, 2017 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-27629084

RESUMO

OBJECTIVES: This study examines the outcome and procedural outcomes of percutaneous stent angioplasty for aortic coarctation in patients with Turner syndrome (TS). BACKGROUND: TS occurs in 1 in 2,500 live-born females and is associated with aortic coarctation. METHODS: In this multicenter, retrospective cohort study, all patients with TS and a coarctation of the aorta, treated with percutaneous stent implantation were included. The procedural strategies were dictated by local protocols. Adverse events at short- and long-term follow-up and qualitative parameters concerning the stent implantation were assessed. RESULTS: In the largest study to date of TS patients receiving aortic stents, a total of 19 patients from 10 centers were included. Twelve patients were treated for native and 7 for recurrent coarctation. Age at intervention was 16.9 (7-60) years (median; min-max). The coarctation diameter increased significantly from 8.0 mm (2-12) pre-intervention to 15.0 mm (10-19) post-intervention (P < 0.001). Three (15.8%) adverse events occurred within 30 days of the procedure, including two dissections despite the use of covered stents, one resulting in death. At long-term follow-up (6.5 years, min-max: 1-16), two additional deaths occurred not known to be stent-related. CONCLUSIONS: Though percutaneous treatment of aortic coarctation in TS patients is effective, it is associated with serious morbidity and mortality. These risks suggest that alternative treatment options should be carefully weighed against percutaneous stenting strategies. © 2016 Wiley Periodicals, Inc.


Assuntos
Angioplastia/efeitos adversos , Angioplastia/instrumentação , Coartação Aórtica/terapia , Stents , Síndrome de Turner/complicações , Adolescente , Adulto , Angioplastia/mortalidade , Coartação Aórtica/complicações , Coartação Aórtica/diagnóstico , Coartação Aórtica/mortalidade , Aortografia/métodos , Criança , Angiografia por Tomografia Computadorizada , Feminino , Humanos , Pessoa de Meia-Idade , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Síndrome de Turner/diagnóstico , Síndrome de Turner/mortalidade , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA