Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 274
Filtrar
1.
Eur J Oral Sci ; 132(1): e12963, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38040662

RESUMO

The aim of this study was to assess the percentage degree of cure (DC%) of 2-mm-thick resin composite attachments used for aligner treatment. Three types of aligner - two thermoformed aligners (Clear Aligner [CLA], polyethylene terephthalate glycol modified; and Invisalign [INV], polyester urethane) and a three-dimensional-printed aligner (Graphy TC-85DAC [GRP], an acrylate-methacrylate copolymer) - were selected, along with two universal resin composites (3M Filtek Universal [FTU] and Charisma Topaz ONE [CTO]). Samples of each composite were placed under each aligner, and the degree of cure of each composite was evaluated on the top (facing the aligner) and the bottom (facing the substrate) attachment surfaces after curing. Five specimens were used per combination of aligner and composite, and an additional group of composites irradiated without aligners served as the control. The DC% measurements were performed using attenuated total reflection Fourier transform infrared (ATR-FTIR) spectroscopy. The DC% across the aligners were (median values) 33.8%-44.8% for CLA, 33.6%-40.8% for INV, 32.8%-40.6% for GRP, and 40.0%-51.7% for the control group. The DC% values of the attachments cured under any aligner were significantly lower than that of the corresponding control, with the values recorded on the top surfaces being 6% higher than those on the bottom surfaces after adjusting for aligner group and composite type.


Assuntos
Metacrilatos , Polímeros , Metacrilatos/química
2.
Orthod Craniofac Res ; 27(4): 572-581, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38404201

RESUMO

OBJECTIVE: The curve of Spee is deemed important characteristic of the dentition for a balanced occlusion and distribution of masticatory forces, while orthodontic levelling of an accentuated curve of Spee is generally included as a treatment goal for deepbite correction. However, relapse is often seen and can be problematic. METHODS: A retrospective longitudinal study of predominantly young patients with a deep curve of Spee, who had been treated orthodontically with 0.018"-slot Edgewise fixed appliances, was performed. The depth of the curve of Spee was digitally measured before treatment (T1), at debond (T2), and an average of 7 years post-debond (T3) and analysed statistically at 5%. RESULTS: A total of 157 patients were included (56.7% female; 11.6-year-old at T1), 16.6% of which were treated with premolars extractions. Non-extraction treatment reduced the curve of Spee at the first premolar from 1.87 mm (T1) to 0.22 mm (T2), which relapsed 0.12 mm (T3; P = .04). The respective depths for the second premolar were 2.0 mm (T1), reduced to 0.80 mm (T2). No significant relapse was seen for the second premolar (0.08 mm; P > .05) or the first permanent molar (0.06 mm; P > .05). No overall significant differences in absolute relapse were seen between extraction and non-extraction patients, but premolar extractions were associated with less clinically relevant relapse at the first molar (odds ratio 0.27; 95%-confidence interval 0.08-0.88; P = .003). CONCLUSION: Steep curves of Spee can be satisfactorily levelled orthodontically with satisfactory stability in the long term, while premolar extractions might be associated with less relapse.


Assuntos
Recidiva , Humanos , Feminino , Estudos Longitudinais , Estudos Retrospectivos , Masculino , Criança , Sobremordida/terapia , Aparelhos Ortodônticos Fixos , Adolescente , Extração Dentária , Ortodontia Corretiva/métodos
3.
Eur J Orthod ; 46(1)2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-38071431

RESUMO

AIM: To identify practices of assessment of gender effects in research articles in orthodontics and detect whether there were significant differences in the treatment effects on outcomes according to gender. MATERIALS AND METHODS: Four major orthodontic journals were sought over a 3-year period to identify publications which included assessment of gender effects on outcomes in their reporting. Data were extracted on the following characteristics: journal, year of publication, region of authorship, and study design. For the studies including reporting of gender effects, whether a significant effect existed was further documented. Additionally, for these studies, data were extracted on population, sample size per gender, treatment, comparison, outcome type, and nature and whether gender analysis was based on subgroup testing or included as a main effect. Descriptive statistics, cross-tabulations, univariable, and multivariable regression models were utilized as appropriate. RESULTS: A total of 718 research articles were eligible for inclusion out of a pool of 1,132 screened articles. Of those, 95 reported on any type of analysis on gender effects (95/718; 13.2%). In the 95 studies that reported assessment of gender effects, it was clear that the majority did not detect significant gender-related differences across the documented outcomes (range of frequency distribution for significant gender differences across all outcomes: 0-50%). Twenty-two articles overall (22/95; 23.2%) described a significant gender effect classified by outcome, 12 favoring female and 10 favoring male participants. Patterns of efficacy and adverse outcomes were schemed either favoring female (root resorption: 4/10; 40.0%, periodontal outcomes: 3/11; 27.3%) or male (cephalometric/growth changes following orthodontic treatment: 4/17; 23.5%) patients across the 22 studies with significant effects. Appropriately designed and adequately powered statistical analyses, with gender effect assessment as a main effect in a multivariable regression model was associated with 6.53 times higher odds for identifying significant gender effects (OR = 6.53; 95% CI: 2.15, 19.8; P = .001). CONCLUSIONS: A very small proportion of research studies included gender effect assessment in their analyses. Of those, a quarter described significant effects. Nevertheless, careful analysis planning and strategies should be prioritized to allow for any meaningful interpretation.


Assuntos
Ortodontia , Projetos de Pesquisa , Humanos , Masculino , Feminino , Estudos Transversais , Tamanho da Amostra , Autoria
4.
Eur J Orthod ; 46(1)2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-37936263

RESUMO

OBJECTIVE: The objective of this study was to examine the impact of intraoral aging on the mechanical properties of directly printed aligners (DPA) compared to thermoformed aligners (TA). MATERIALS AND METHODS: This prospective in vivo experiment included three types of aligners: DPAs (group DP) fabricated from Tera Harz TC-85 DAC resin (Graphy, Korea), TA (group INV) made from a polyurethane-based polymer (Align Technology, Inc., CA, USA), and TA (group DUR) made from polyethylene glycol terephthalate based polymer (Scheu-Dental, Germany). Each group was categorized into retrieved (Clin) and unused aligners (Ctr). Thirty patients (10 per group) wore the aligners for 7 days, thereby generating the retrieved samples. Thirty unused aligners were employed as control samples. The following mechanical properties were determined: Martens Hardness (HM), indentation modulus (EIT), elastic index (ηIT), and indentation relaxation (RIT). Intergroup comparisons were conducted using ANOVA/Kruskal-Wallis test. Comparisons between retrieved and control samples were done using Wilcoxon-Mann-Whitney-U/Student's t-test/Welch's test. RESULTS: Statistically significant differences between the groups were found for both control and used samples (P < .001). Pairwise comparisons also revealed significant differences between the samples. The mechanical properties did not differ significantly between unused and retrieved INV- and DUR-aligners, whereas for DP-aligners significant differences for ηIT and RIT were found following intraoral service (P-values .012 and .002, respectively). CONCLUSIONS: Group DUR showed generally more favorable mechanical properties compared to DP and INV. The much higher RIT and EIT in DP aligners suggest their higher rigidity and force decay, which could compromise their clinical efficacy.


Assuntos
Fenômenos Mecânicos , Poliuretanos , Humanos , Estudos Prospectivos , Dureza , Polietilenoglicóis , Teste de Materiais
5.
Eur J Orthod ; 46(1)2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-38073597

RESUMO

OBJECTIVES: Three-dimensional (3D)-printed aligners present a promising orthodontic treatment modality, whose clinical success largely depends on the material's mechanical properties. The aim of this study was to evaluate the mechanical properties of resin-made 3D-printed aligners and assess the effect of two different post-curing conditions. MATERIALS AND METHODS: Forty dumbbell-shaped specimens and 40 resin aligners were 3D-printed and divided into four equal groups according to post-curing conditions: presence or absence of oxygen during post-curing and water heat treatment at 85°C for 15 s or none. Samples from the central incisor of the aligner (n = 5/group) were studied by Attenuated Total Reflection Fourier-transform infrared spectroscopy (ATR-FTIR). The dumbbell-shaped specimens were loaded up to fracture under tensile mode and yield strength, ultimate tensile strength, elastic and plastic strain were calculated. The first mandibular molar area from 3D-printed aligners (n = 10/group) was cut and embedded in acrylic resin and then underwent metallographic grinding and polishing followed by instrumented indentation testing to determine the following mechanical properties: Martens hardness, indentation modulus, elastic index, and indentation relaxation. After descriptive statistics, differences according to each post-curing protocol, as well as their combination, were analyzed with linear regression modeling at a 5% significance level. RESULTS: All groups showed identical ATR-FTIR spectra, while no statistically significant effects were seen for either post-curing protocol (N2 presence and heat treatment) or their combination (P > .05 in all instances). CONCLUSIONS: The mechanical properties of 3D-printed resin aligners were not considerably affected either by post-curing in N2 atmosphere or heat treatment.


Assuntos
Temperatura Alta , Dente , Humanos , Dureza , Impressão Tridimensional , Teste de Materiais , Propriedades de Superfície
6.
Eur J Orthod ; 46(4)2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-38884540

RESUMO

AIM: The aim of the present study was to assess the alterations in morphology, roughness, and composition of the surfaces of a conventional and a flowable composite attachment engaged with aligners, and to evaluate the release of resin monomers and their derivatives in an aqueous environment. METHODS: Zirconia tooth-arch frames (n = 20) and corresponding thermoformed PET-G aligners with bonded attachments comprising two composite materials (universal-C and flowable-F) were fabricated. The morphological features (stereomicroscopy), roughness (optical profilometry), and surface composition (ATR-FTIR) of the attachments were examined before and after immersion in water. To simulate intraoral use, the aligners were removed and re-seated to the frames four times per day for a 7-day immersion period. After testing, the eluents were analyzed by LC-MS/MS targeting the compounds Bis-GMA, UDMA, 2-HEMA, TEGDMA and BPA and by LC-HRMS for suspect screening of the leached dental material compounds and their degradation products. RESULTS: After testing, abrasion-induced defects were found on attachment surfaces such as scratches, marginal cracks, loss of surface texturing, and fractures. The morphological changes and debonding rate were greater in F. Comparisons (before-after testing) revealed a significantly lower Sc roughness parameter in F. The surface composition of the aligners after testing showed minor changes from the control, with insignificant differences in the degree of C = C conversion, except for few cases with strong evidence of hydrolytic degradation. Targeted analysis results revealed a significant difference in the compounds released between Days 1 and 7 in both materials. Insignificant differences were found when C was compared with F in both timeframes. Several degradation products were detected on Day 7, with a strong reduction in the concentration of the targeted compounds. CONCLUSIONS: The use of aligners affects the surface characteristics and degradation rate of composite attachments in an aqueous environment, releasing monomers, and monomer hydrolysates within 1-week simulated use.


Assuntos
Resinas Compostas , Teste de Materiais , Metacrilatos , Propriedades de Superfície , Zircônio , Zircônio/química , Resinas Compostas/química , Metacrilatos/química , Polietilenoglicóis/química , Ácidos Polimetacrílicos/química , Poliuretanos/química , Bis-Fenol A-Glicidil Metacrilato/química , Materiais Dentários/química , Técnicas In Vitro , Humanos , Técnicas de Movimentação Dentária/instrumentação , Técnicas de Movimentação Dentária/métodos , Espectroscopia de Infravermelho com Transformada de Fourier/métodos
7.
Eur J Orthod ; 46(3)2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38819172

RESUMO

BACKGROUND: The minimal important difference (MID) is defined as the smallest difference that the patient perceives as important. Furthermore, the smallest worthwhile effect (SWE) is the important change measured with the benefit-harm trade-off method. The aim of this study was to evaluate the MID in orthodontic treatment duration to inform the decision regarding seeking procedures to accelerate orthodontic tooth movement and reduce treatment duration. METHODS: We constructed a survey eliciting views of the MID from adult participants from four countries undergoing orthodontic treatment. Ten questions addressed reduction in the treatment duration for both durations 12 and 24 months, and four questions were related to the reduction in treatment duration that the patients would require to undergo surgical or non-surgical adjunctive procedures. We applied a univariable random effects logistic regression model to examine the association between the participants' characteristics and the MID. Then, we fitted a multivariable logistic random effects regression including significant predictors. RESULTS: Four hundred and fifty adults, with a median age of 21 (interquartile range: 19-24), undergoing orthodontic treatment participated in the survey. Of the respondents, 60% considered 15 days as a trivial reduction from 12 months duration of therapy and 70% considered 15 days a trivial reduction from 24 months. Of the respondents, 48% considered the period of 2 months a moderate reduction from 12 months, and 60% considered 2 months a moderate reduction from 24 months. From these results, we inferred that patients considered reductions of approximately 1 month as the MID in the treatment duration for both 12 and 24 months. However, SWE was considerably more than the MID for most of the participants to decide undergoing surgical adjunctive procedures to reduce the time of therapy. The participants required smaller SWE to undergo non-surgical procedures compared to surgical procedures. CONCLUSION: The MID in the treatment duration is one month for both treatment durations 12 and 24 months. Patients require a greater SWE than the MID to undergo adjunctive procedures to shorten the duration, particularly for surgical procedures.


Assuntos
Ortodontia Corretiva , Humanos , Feminino , Masculino , Fatores de Tempo , Adulto Jovem , Ortodontia Corretiva/métodos , Inquéritos e Questionários , Adulto , Técnicas de Movimentação Dentária/métodos
8.
Orthod Craniofac Res ; 26(3): 476-480, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36648375

RESUMO

OBJECTIVES: Three-dimensional (3D) printing technology is a promising manufacturing technique for fabricating ceramic brackets. The aim of this research was to assess fundamental mechanical properties of in-office, 3D printed ceramic brackets. MATERIALS AND METHODS: 3D-printed zirconia brackets, commercially available polycrystalline alumina ceramic brackets (Clarity, 3 M St. Paul, MN) and 3D-printed customized polycrystalline alumina ceramic ones (LightForce™, Burlington, Massachusetts) were included in this study. Seven 3D printed zirconia brackets and equal number of ceramic ones from each manufacturer underwent metallographic grinding and polishing followed by Vickers indentation testing. Hardness (HV) and fracture toughness (K1c) were estimated by measuring impression average diagonal length and crack length, respectively. After descriptive statistics calculation, group differences were analysed with 1 Way ANOVA and Holm Sidak post hoc multiple comparison test at significance level α = .05. RESULTS: Statistically significant differences were found among the materials tested with respect to hardness and fracture toughness. The 3D-printed zirconia proved to be less hard (1261 ± 39 vs 2000 ± 49 vs 1840 ± 38) but more resistant to crack propagation (K1c = 6.62 ± 0.61 vs 5.30 ± 0.48 vs 4.44 ± 0.30 MPa m1/2 ) than the alumina brackets (Clarity and Light Force respectivelty). Significant differences were observed between the 3D printed and the commercially available polycrystalline alumina ceramic brackets but to a lesser extent. CONCLUSIONS: Under the limitations of this study, the 3D printed zirconia bracket tested is characterized by mechanical properties associated with advantageous orthodontic fixed appliances traits regarding clinically relevant parameters.


Assuntos
Óxido de Alumínio , Cerâmica , Dureza , Teste de Materiais , Óxido de Alumínio/química , Propriedades de Superfície
9.
Clin Oral Investig ; 27(5): 1851-1868, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36879148

RESUMO

OBJECTIVE: To assess the pain profile of patients in the levelling/alignment phase of orthodontic treatment, as reported from randomized clinical trials. MATERIALS AND METHODS: Five databases were searched in September 2022 for randomized clinical trials assessing pain during levelling/alignment with a visual analogue scale (VAS). After duplicate study selection, data extraction, and risk-of-bias assessment, random effects meta-analyses of mean differences (MDs) and their 95% confidence intervals (CIs) were performed, followed by subgroup/meta-regression, and certainty analyses. RESULTS: A total of 37 randomized trials including 2277 patients (40.3% male; mean age 17.5 years) were identified. Data indicated quick pain initiation after insertion of orthodontic appliances (n = 6; average = 12.4 mm VAS), a quick increase to a peak at day 1 (n = 29; average = 42.4 mm), and gradually daily decrease the first week until its end (n = 23; average = 9.0 mm). Every second patient reported analgesic use at least once this week (n = 8; 54.5%), with peak analgesic use at 6 h post-insertion (n = 2; 62.3%). Patients reported reduced pain in the evening compared to morning (n = 3; MD = - 3.0 mm; 95%CI = - 5.3, - 0.6; P = 0.01) and increased pain during chewing (n = 2; MD = 19.2 mm; 95% CI = 7.9, 30.4; P < 0.001) or occlusion of the back teeth (n = 2; MD = 12.4 mm; 95% CI = 1.4, 23.4; P = 0.3), while non-consistent effects were seen for patient age, sex, irregularity, or analgesic use. Subgroup analyses indicated increased pain among extraction cases and during treatment of the lower (rather than the upper) arch, while certainty around estimates was moderate to high. CONCLUSIONS: Evidence indicated a specific pain profile during orthodontic levelling/alignment, without signs of consistent patient-related influencing factors.


Assuntos
Aparelhos Ortodônticos Fixos , Dor , Humanos , Masculino , Adolescente , Feminino , Ensaios Clínicos Controlados Aleatórios como Assunto , Analgésicos/uso terapêutico
10.
Am J Orthod Dentofacial Orthop ; 163(5): e127-e136, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36934057

RESUMO

INTRODUCTION: This study aimed to evaluate changes in palatal shape after orthodontic treatment from a borderline sample of extraction and nonextraction patients with a Class I relationship. METHODS: A borderline sample regarding premolar extractions was obtained through discriminant analysis and comprised 30 nonextraction and 23 extraction patients. The digital dental casts of these patients were digitized with 3 curves and 239 landmarks placed on the hard palate. Procrustes superimposition and principal component analysis were implemented to assess group shape variability patterns. RESULTS: The success of the discriminant analysis in identifying a borderline sample regarding the extraction modality was validated using geometric morphometrics. Concerning palatal shape, no sexual dimorphism was found (P = 0.78). The first 6 principal components that were statistically significant accounted for 79.2% of the total shape variance. Palatal changes were 61% more pronounced in the extraction group, which exhibited a decrease in palatal length (P = 0.02; 10,000 permutations). In contrast, the nonextraction group showed an increase in the palatal width (P <0.001; 10,000 permutations). Intergroup comparisons indicated that the nonextraction group exhibited longer palates, whereas the extraction group exhibited higher palates (P = 0.02; 10,000 permutations). CONCLUSIONS: Considerable changes in palatal shape were seen for the nonextraction and extraction treatment group, with the latter exhibiting more pronounced changes, mainly in terms of palatal length. Further investigations are needed to clarify the clinical significance of the palatal shape changes in borderline patients after extraction and nonextraction treatment.


Assuntos
Palato , Extração Dentária , Humanos , Cefalometria , Dente Pré-Molar/cirurgia
11.
Eur J Orthod ; 45(3): 250-257, 2023 05 31.
Artigo em Inglês | MEDLINE | ID: mdl-36308302

RESUMO

OBJECTIVES: Interproximal enamel reduction (IPR) is routinely used in orthodontics to generate small to moderate amounts of space within the dental arch. Aim of this ex vivo study was to evaluate the effect of two different IPR systems on the enamel surface's waviness, roughness, and elemental composition after 6 months of intraoral exposure. MATERIALS AND METHODS: Fifteen orthodontic extraction patients were included in the present study. The 39 healthy premolars, which were scheduled to be extracted, were subjected to IPR at least 6 months before their extraction. IPR was performed on their mesial side with two different methods: (1) instrumented method with the Ortho-Strips system (on handpiece) and (2) manually with the Intensiv ProxoStrip (strips)-each with four different grits for contouring, finishing, and polishing. The distal side of each premolar served as its own internal control. Treated and untreated tooth surfaces were evaluated by optical profilometry, Raman, and scanning electron microscope/X-ray energy-dispersive (EDX) analyses. Data were analysed with descriptive statistics and generalized linear models at alpha = 5%. RESULTS: Both IPR methods significantly reduced the waviness of the enamel surface (P < 0.001), with manual IPR leading to smaller waviness reductions than the instrumented IPR (P ≤ 0.001). On the other side, both IPR methods led to a significant increase in enamel surface roughness (P < 0.001), with no significant differences between IPR methods. EDX and Raman analyses did not demonstrate any alterations on elemental composition of enamel after at least 6 months of intraoral exposure. CONCLUSIONS: Both stripping systems led to a flatter but rougher enamel surface. Further polishing is needed to restore the initial enamel smoothness. The elemental composition of the stripped enamel returns to the baseline level after 6 months of intraoral exposure.


Assuntos
Esmalte Dentário , Procedimentos de Cirurgia Plástica , Humanos , Dente Pré-Molar , Propriedades de Superfície
12.
Eur J Orthod ; 45(3): 244-249, 2023 05 31.
Artigo em Inglês | MEDLINE | ID: mdl-36130120

RESUMO

AIM: To quantitatively assess the degree of conversion and the water-leaching targeted compound from 3D-printed aligners. MATERIALS AND METHODS: 3D-printed aligners were made of photopolymerized resin (Tera Harz TC85A). The molecular structure and degree of conversion of the set resin were investigated by ATR-FTIR spectroscopy (n = 5). The aligners (n = 10) were immersed in double distilled water for 1 week at 37°C and the eluents were analysed using liquid chromatography/mass spectrometry methods (LC-ESI-MS/MS for urethane dimethacrylate [UDMA] and LC-APCI-MS/MS for bispenol-A [BPA]). RESULTS: The resin was composed of aliphatic vinyl ester-urethane monomers, with acrylate and/or methacrylate functionalization. The degree of conversion was estimated as to 83%. There was no detection of BPA in any of the assessed samples (0.25 µg/l). Quantifiable amounts of UDMA were detected in all the exposed samples, ranging from 29 to 96 µg/l. CONCLUSIONS: Although efficiently polymerized and BPA free, the great variability in the amount of UDMA monomer leached from the examined samples may raise concerns on potential health hazards after repeated intraoral exposure, which is indicated for this class of materials.


Assuntos
Resinas Compostas , Ácidos Polimetacrílicos , Humanos , Resinas Compostas/química , Bis-Fenol A-Glicidil Metacrilato/química , Ácidos Polimetacrílicos/química , Espectrometria de Massas em Tandem , Polietilenoglicóis/química , Metacrilatos/química , Poliuretanos/química , Impressão Tridimensional , Teste de Materiais
13.
J Orthod ; 50(4): 352-360, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-36573484

RESUMO

OBJECTIVE: To assess the surface roughness of in-house 3D-printed orthodontic aligners compared with Invisalign® appliances, both retrieved as well as in the 'as-received' control status. DESIGN: An in vitro study following intra-oral material aging. SETTING AND PARTICIPANTS: Twelve clinically used Invisalign® appliances and the same number of 3D-printed aligners, without involvement of attachments, were obtained from a respective number of patients. A similar number of 'as-received' aligners, of each material, were used as control (CON) groups. METHOD: Four groups of materials were examined: A = Invisalign® CON; B = Invisalign® used; C = 3D-printed CON; and D = 3D-printed used. Optical profilometry was employed to examine the following surface roughness parameters: amplitude parameters Sa, Sq and Sz and functional parameters Sc and Sv. Descriptive statistics and quantile regression modeling were conducted, and the level of statistical significance was set at α = 0.05. RESULTS: Intra-oral exposure of 3D-printed aligners was significantly associated with increase in all tested parameters (P < 0.001 at all occasions). Significant differences were detected in the retrieved 3D-printed aligners compared with Invisalign® retrieved, with the exception of Sz. The respective effect sizes (median differences) were as follows: Sa: 169 nm, 95% confidence interval [CI] = 89-248, P < 0.001; Sq: 315 nm, 95% CI = 152-477, P < 0.001; Sc: 233 nm3/nm2, 95% CI = 131-335, P < 0.001; and Sv: 43 nm3/nm2, 95% CI = 17-68, P = 0.002. CONCLUSION: Within the limitations of this study, we concluded that surface roughness differences existed between 3D-printed aligners and Invisalign® in the retrieved status, as well as between the control and retrieved 3D-printed groups.


Assuntos
Aparelhos Ortodônticos Removíveis , Humanos , Envelhecimento , Impressão Tridimensional
14.
J Clin Periodontol ; 49 Suppl 24: 102-120, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-34327710

RESUMO

AIM: To assess the beneficial and adverse effects on the dental and periodontal issues of periodontal-orthodontic treatment of teeth with pathological tooth flaring, drifting, and elongation in patients with severe periodontitis. MATERIALS AND METHODS: Nine databases were searched in April 2020 for randomized/non-randomized clinical studies. After duplicate study selection, data extraction, and risk-of-bias assessment, random-effect meta-analyses of mean differences (MDs) and their 95% confidence intervals (CIs) were performed, followed by subgroup/meta-regression analyses. RESULTS: A total of 30 randomized and non-randomized clinical studies including 914 patients (29.7% male; mean age 43.4 years) were identified. Orthodontic treatment of pathologically migrated teeth was associated with clinical attachment gain (-0.24 mm; seven studies), pocket probing depth reduction (-0.23 mm; seven studies), marginal bone gain (-0.36 mm; seven studies), and papilla height gain (-1.42 mm; two studies) without considerable adverse effects, while patient sex, gingival phenotype, baseline disease severity, interval between periodontal and orthodontic treatment, and orthodontic treatment duration affected the results. Greater marginal bone level gains were seen by additional circumferential fiberotomy (two studies; MD = -0.98 mm; 95% CI = -1.87 to -0.10 mm; p = .03), but the quality of evidence was low. CONCLUSIONS: Limited evidence of poor quality indicates that orthodontic treatment might be associated with small improvements of periodontal parameters, which do not seem to affect prognosis, but more research is needed.


Assuntos
Periodontite , Feminino , Humanos , Masculino , Periodontite/complicações , Periodontite/terapia
15.
Clin Oral Implants Res ; 33(5): 482-491, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35194854

RESUMO

AIM: To assess the frequency and quantity of interproximal contact loss (ICL) between implant restorations and adjacent teeth after at least 10 years of follow-up (FU). METHODS: Thirty-nine patients (median age 57.3 years) with 80 implants were re-examined at least 10 years after insertion of final restorations (single crowns or fixed dental prostheses (FDPs)). Baseline (insertion of the restorations) and FU examinations encompassed the following: Stone casts were scanned and superimposed for metric assessment of tooth movements, radiographs, and clinical measurements. Outcome measures at implant sites were as follows: the extent of tooth movement and the frequency of interproximal contact loss [ICL], peri-implant marginal bone levels [MBLs], and clinical measurements (plaque control record [PCR], Bleeding on Probing [BOP], and probing depth [PD]). Data were analyzed statistically with generalized regression modeling with robust standard errors to account for within-patient clustering at 5%. RESULTS: Interproximal contact loss for at least one contact point after 10 years was observed in 50% of all implants (with open interproximal spaces up to 1.64 mm). Mesial contact points were significantly more prone to ICL than distal ones (relative risk [RR] = 1.79; 95% confidence interval [CI] = 1.07-2.99; p = .03). The type of restoration had a significant effect on ICL, with FDPs of 2 implants being significantly more prone to mesial ICL than single crowns (RR = 1.52; 95% CI = 1.02-2.25; p = .04). ICL was also associated with a significant increase in PD (+0.46 mm (95% CI = 0.04-0.88 mm; p = .03)) compared to implant sites without ICL. BOP, MBLs, and PCR were not significantly influenced by ICL. CONCLUSION: Interproximal contact loss was a common finding in 50% of the implant sites and was significantly associated with an increase in PD.


Assuntos
Implantes Dentários , Dente , Coroas , Prótese Dentária Fixada por Implante , Seguimentos , Humanos , Pessoa de Meia-Idade , Estudos Retrospectivos
16.
Orthod Craniofac Res ; 25(3): 336-341, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34569692

RESUMO

OBJECTIVE: The aim of this study was to compare the mechanical properties of orthodontic aligners among different commercially available 3D printing devices. MATERIALS AND METHODS: Five 3D printers (Ka:rv LP 550, Swinwon; "KAR"), (L120, Dazz 3D; "L12"), (MiiCraft 125, Miicraft Jena; "MIC"), (Slash 2, Uniz; "SLS") and (Pro 95, SprintRay; "PRO") were used to prepare orthodontic aligners with dental resin (Tera Harz TC-85DAW, Graphy). The central incisors of each aligner were cut, prepared and evaluated in terms of Martens-Hardness (HM), indentation-modulus (EIT ) and elastic-index (ηIT ) as per ISO14577-1:2002. Force-indentation curves were recorded and differences among printers were checked with generalized linear regressions (alpha=5%). RESULTS: Statistically significant differences were seen for all mechanical properties (P < .05), which were in descending order: HM (N/mm2 ) as median (Interquartile Range [IQR]): SLS 108.5 (106.0-112.0), L12 103.0 (102.0-107.0), KAR 101.5 (97.5-103.0), MIC 100.0 (97.5-101.5) and PRO 94.0 (93.0-96.0); EIT (MPa) as mean (Standard Deviation [SD]): SLS 2696.3 (124.7), L12 2627.8 (73.5), MIC 2566.2 (125.1), KAR 2565.0 (130.2) and PRO 2491.2 (53.3); and ηIT (%) as median (IQR): SLS 32.8 (32.3-33.1), L12 31.6 (30.8-32.3), KAR 31.3 (30.9-31.9), MIC 30.5 (29.9-31.2) and PRO 29.5 (29.1-30.0). Additionally, significant differences existed between liquid crystal display (LCD) and digital light processing (DLP) printers for HM (P < .001), EIT (P = .002) and ηIT (P < .001), with aligners from the former having higher values than aligners from the latter printer. CONCLUSION: Under the limitations of this study, it may be concluded that the mechanical properties of 3D-printed orthodontic aligners are dependent on the 3D printer used, and thus, differences in their clinical efficacy are anticipated.


Assuntos
Impressão Tridimensional , Dureza , Teste de Materiais
17.
Orthod Craniofac Res ; 25(4): 530-540, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-35014186

RESUMO

OBJECTIVE: The purpose of this investigation of untreated monozygotic and dizygotic twins was to identify the genetic and environmental components to the facial soft tissue growth. SETTINGS AND SAMPLE POPULATION: The sample consisted of 52 untreated monozygotic twins (36 male and 16 female) and 46 untreated dizygotic twins (23 male and 23 female) from the Forsyth Moorrees Twin Study (1959-1975). MATERIALS AND METHODS: Lateral cephalograms were taken at 12 and 17 years of age and traced to analyse facial convexity, nasolabial angle, upper and lower lip thickness, upper and lower lip profile and nose prominence. The genetic and environmental components of variance were analysed with structural equation modelling for multilevel mixed-effects model. RESULTS: At 12 years of age, strong additive genetic influence was seen for facial convexity (70%), upper lip profile (66%) and nose prominence (65%), whereas strong dominant genetic components were found for upper lip thickness (56%). Nevertheless, under unique environment influence were nasolabial angle (58%), lower lip profile (51%) and lower lip thickness (64%). At 17 years of age, only upper lip thickness (55%) and nose prominence (84%) were under strong additive genetic control, while the rest of the variables were under strong dominant genetic control. The only exception was lower lip thickness (61%), which is still influenced by the unique environment. CONCLUSION: Although monozygotic/dizygotic twins share at least part of their genome, at both times either additive, dominant or environmental components were found. Nevertheless, at 17 years of age most of the variables are either under additive or dominant genetic influence.


Assuntos
Face , Gêmeos Dizigóticos , Cefalometria , Face/anatomia & histologia , Feminino , Humanos , Masculino , Estudos Retrospectivos , Gêmeos Dizigóticos/genética , Gêmeos Monozigóticos/genética
18.
Am J Orthod Dentofacial Orthop ; 162(3): e116-e122, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35842359

RESUMO

INTRODUCTION: Orthodontic aligners printed with in-office 3-dimensional (3D) procedures have been described, but no data on their biocompatibility exist. This study investigates the cytotoxicity and estrogenicity of a 3D-printed orthodontic aligner by assessing its biological and behavioral effects. METHODS: Ten sets of 1 type of aligner were immersed in sterile deionized water for 14 days, and the cytotoxicity and estrogenicity of released factors were assessed via MTT (3-[4,5-dimethylthiazol-2-yl]-2,5-diphenyltetrazolium bromide) assays on human gingival fibroblasts and the estrogen-sensitive MCF-7 and the estrogen-insensitive MDA-MB-231 breast cancer cell lines. 17ß-Estradiol and bisphenol-A were used as positive controls. The statistical analysis of data was performed with generalized linear models at a 0.05 level of significance. RESULTS: No signs of cytotoxicity were seen for the aligner samples for concentrations (v/v) of 20% (P = 0.32), 10% (P = 0.79), or 5% (P = 0.76). The antioxidant activity expressed as the capacity to reduce intracellular levels of reactive oxygen species was not affected in the aligner samples (P = 0.08). No significant estrogenicity was induced by the aligner samples compared with eluents from the negative control for both MCF-7 (P = 0.65) and MDA-MB-231 (P = 0.78). As expected, 17ß-Estradiol and bisphenol-A stimulated MCF-7 cell proliferation, whereas no effect was observed on MDA-MB-231 cells. CONCLUSIONS: In conclusion, if any factors were released during the 14-day aging of 3D-printed aligners in water, these were not found to be cytotoxic for human gingival fibroblasts and did not affect their intracellular reactive oxygen species levels. Moreover, no estrogenic effects of these putative eluates were observed based on an E-screen assay.


Assuntos
Estradiol , Estrogênios , Estradiol/farmacologia , Estrogênios/farmacologia , Humanos , Oxigênio , Impressão Tridimensional , Água
19.
Eur J Orthod ; 44(5): 537-547, 2022 09 19.
Artigo em Inglês | MEDLINE | ID: mdl-35285904

RESUMO

AIM: To assess whether the efficacy of external tooth bleaching differs between untreated and orthodontically treated teeth. MATERIALS AND METHOD: Three groups of subjects were formed; group Debonded included 24 consecutive orthodontically treated patients evaluated immediately after removal of fixed appliances. The Retention group included 24 consecutive orthodontically treated patients in the phase of retention. The Untreated group consisted of 24 arbitrarily selected undergraduate dental students without history of fixed-appliances orthodontic therapy. Each of the above three groups was further randomized into two subgroups, Bleaching and Placebo. Each subgroup received either a 38% hydrogen peroxide bleaching treatment or a placebo agent, respectively. Tooth colour changes were assessed at seven timepoints: 1 day before intervention; on the day of intervention before and after treatment; and at 7, 14, 21, and 90 days for parameters L*, a*, b*, and ΔΕ in all upper incisors and canines with the use of a reflectance spectrophotometer. Intra-rater agreement was estimated with the Intra-class Correlation Coefficient and method's error was calculated using the Repeatability Coefficient. Regarding tooth colour changes, an analysis of variance was used to assess differences between groups. RESULTS: Bleaching was associated with an increase of the L* value and decrease of b* and a* values in both orthodontically treated and untreated teeth. Parameters ΔE, L*, and b* exhibited statistically significant differences between the Bleaching-Untreated and Bleaching-Retention subgroups. In the Bleaching subgroups, statistically significant differences were found between different teeth for all parameters. CONCLUSIONS: Previous exposure to fixed orthodontic appliance influenced the efficacy of external tooth bleaching. The effect of bleaching was higher after orthodontic treatment and with longer period in retention. Canines changed in colour more than incisors, and the effect was reduced over time.


Assuntos
Peróxido de Hidrogênio , Clareamento Dental , Cor , Humanos , Peróxido de Hidrogênio/uso terapêutico , Incisivo , Espectrofotometria
20.
Eur J Orthod ; 44(3): 325-331, 2022 05 24.
Artigo em Inglês | MEDLINE | ID: mdl-34435635

RESUMO

BACKGROUND: SITAR (SuperImposition by Translation And Rotation) is a shape invariant growth curve model that effectively summarizes somatic growth in puberty. AIM: To apply the SITAR model to longitudinal mandibular growth data to clarify its suitability to facial growth analysis. SUBJECTS AND METHODS: 2D-cephalometric data on two mandibular measurements (AP: articulare-pogonion; CP: condylion-pogonion) were selected from the Denver Growth Study, consisting of longitudinal records (age range: 7.9-19.0 years) of females (sample size N: 21; number of radiographs n: 154) and males (N: 18; n: 137). The SITAR mixed effects model estimated, for each measurement and gender separately, a mean growth curve versus chronological age, along with mean age at peak velocity (APV) and peak velocity (PV), plus subject-specific random effects for PV and mean size. The models were also fitted versus Greulich-Pyle bone age. RESULTS: In males, mean APV occurred at 14.6 years (AP) and 14.4 years (CP), with mean PV 3.1 mm/year (AP) and 3.3 mm/year (CP). In females, APV occurred at 11.6 years (AP and CP), with mean PV 2.3 mm/year (AP) and 2.4 mm/year (CP). The models explained 95-96 per cent of the cross-sectional variance for males and 92-93 per cent for females. The random effects demonstrated standard deviations (SDs) in size of 5.6 mm for males and 3.9 mm for females, and SDs for PV between 0.3 and 0.5 mm/year. The bone age results were similar. CONCLUSION: The SITAR model is a useful tool to analyse epidemiological craniofacial growth based on cephalometric data and provides an array of information on pubertal mandibular growth and its variance in a concise manner.


Assuntos
Estatura , Puberdade , Adolescente , Adulto , Cefalometria , Criança , Estudos Transversais , Feminino , Humanos , Masculino , Mandíbula/diagnóstico por imagem , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA