RESUMO
In this work, we evaluated the change of primary monitor characteristics in two consecutive years. Sixty-six primary monitors were included in the analysis. The monitors were located at radiology physicians' offices and radiology reading rooms. All primary monitors were equipped with the manufacturer's built-in photometers and connected to the BarcoMediCalQA web service for manual and automatic quality control measurements. External photometer/illuminance meter (RaySafe Solo Light) was used to measure the luminance values. Measured luminance values of the TG18LN1-18 and TG18UNL80 test patterns were used to evaluate the primary monitors performance. In a comparison of the quality assurance (QA) measurement results for the same monitors that were performed within 2 years, the luminance of 25 displays remained statistically the same (P > 0.01). The luminance of 17 displays decreased (P < 0.01) in 2017 when compared with 2016, the luminance of 24 displays increased (P < 0.01) in 2017 when compared with 2016. For the annual measurements of the MLD in 2016 and 2017, 25 out of 66 displays showed a decrease of MLD values in 2017 compared with the same measurements in 2016 and 41 displays showed an increase of MLD in 2017. All tested primary displays had the MLD value less than 17.2%. The mean value of illuminance measured in 2016 was 5.8 lux ± 3.1 lux. In 2017, the mean value of illuminance measured was 8.7 lux ± 5.3 lux. Although it is expected that monitors luminance values will decrease over time, we found displays with increased luminance. This is possibly due to the multiple monitor calibrations that were performed between two annual monitor QA tests. Based on the findings of this work, more efficient display QA programs with a shorter time interval than 1 year are needed.
Assuntos
Apresentação de Dados/normas , Diagnóstico por Imagem/instrumentação , Diagnóstico por Imagem/normas , Fotometria/normas , Controle de Qualidade , Sistemas de Informação em Radiologia/normas , Calibragem , Gráficos por Computador/normas , Humanos , Medições Luminescentes , Fatores de TempoRESUMO
The purpose of this work was to perform the initial evaluation of primary diagnostic monitor (PDM) characteristics following the implementation of New York City quality assurance (NYC QA) regulations on January 1, 2016, and compare the results of the QA measurements performed by an external photometer and the PDM manufacturer's built-in photometer. TG-18 and Society of Motion Picture and Television Engineers test patterns were used to evaluate monitor performance. Overall, 79 PDMs were included in the analysis. The verification of grayscale standard display function (GSDF) calibration, using a built-in photometer, showed that only 2 out of 79 PDMs failed calibration. However, the same measurements performed by the external luminance meter showed that 15 out of 79 monitors had failed GSDF calibration. Measurements of the PDMs maximum luminance (Lmax ), using an external photometer showed that 10 out of 53 PDMs calibrated for Lmax = 400 cd/m2 and 17 out of 26 PDMs calibrated for Lmax = 500 cd/m2 do not meet the manufacturer's recommended 10% tolerance limit for the target Lmax calibration. Two PDMs did not pass the Lmax ≥ 350 cd/m2 NYC QA regulations with Lmax = 331 cd/m2 and Lmax = 340 cd/m2 . All tested PDMs exceeded the minimum luminance ratio (LR) of 250:1 as required by NYC QA regulations. Measurements taken of Lmax and LR performed by a built-in photometer showed that none of the PDMs had failed the NYC QA regulations. All PDMs passed the luminance uniformity test with a maximum nonuniformity of 17% (according to NYC regulations it must be less than 30%). The luminance uniformity test could only be performed using an external photometer. The evaluation of 79 PDMs of various ages and models demonstrated up to 18% disagreement between luminance measurements performed by the manufacturer's built-in photometer when compared with those performed by an externally calibrated luminance meter. These disagreements were larger for older PDMs.
Assuntos
Diagnóstico por Imagem/instrumentação , Processamento de Imagem Assistida por Computador/métodos , Fotometria/instrumentação , Garantia da Qualidade dos Cuidados de Saúde/normas , Calibragem , Humanos , Medições Luminescentes , Padrões de ReferênciaRESUMO
We map single energy CT (SECT) scans to synthetic dual-energy CT (synth-DECT) material density iodine (MDI) scans using deep learning (DL) and demonstrate their value for liver segmentation. A 2D pix2pix (P2P) network was trained on 100 abdominal DECT scans to infer synth-DECT MDI scans from SECT scans. The source and target domain were paired with DECT monochromatic 70 keV and MDI scans. The trained P2P algorithm then transformed 140 public SECT scans to synth-DECT scans. We split 131 scans into 60% train, 20% tune, and 20% held-out test to train four existing liver segmentation frameworks. The remaining nine low-dose SECT scans tested system generalization. Segmentation accuracy was measured with the dice coefficient (DSC). The DSC per slice was computed to identify sources of error. With synth-DECT (and SECT) scans, an average DSC score of 0.93±0.06 (0.89±0.01) and 0.89±0.01 (0.81±0.02) was achieved on the held-out and generalization test sets. Synth-DECT-trained systems required less data to perform as well as SECT-trained systems. Low DSC scores were primarily observed around the scan margin or due to non-liver tissue or distortions within ground-truth annotations. In general, training with synth-DECT scans resulted in improved segmentation performance with less data.
RESUMO
PURPOSE: Hypoxia is one of the main causes of the failure to achieve local control using radiotherapy. This is due to the increased radioresistance of hypoxic cells. (18)F-fluoromisonidazole ((18)F-FMISO) positron emission tomography (PET) is a noninvasive imaging technique that can assist in the identification of intratumor regions of hypoxia. The aim of this study was to evaluate the reproducibility of (18)F-FMISO intratumor distribution using two pretreatment PET scans. METHODS AND MATERIALS: We enrolled 20 head and neck cancer patients in this study. Of these, 6 were excluded from the analysis for technical reasons. All patients underwent an (18)F-fluorodeoxyglucose study, followed by two (18)F-FMISO studies 3 days apart. The hypoxic volumes were delineated according to a tumor/blood ratio >or=1.2. The (18)F-FMISO tracer distributions from the two (18)F-FMISO studies were co-registered on a voxel-by-voxel basis using the computed tomography images from the PET/computed tomography examinations. A correlation between the (18)F-FMISO intensities of the corresponding spatial voxels was derived. RESULTS: A voxel-by-voxel analysis of the (18)F-FMISO distributions in the entire tumor volume showed a strong correlation in 71% of the patients. Restraining the correlation to putatively hypoxic zones reduced the number of patients exhibiting a strong correlation to 46%. CONCLUSION: Variability in spatial uptake can occur between repeat (18)F-FMISO PET scans in patients with head and neck cancer. Blood data for one patient was not available. Of 13 patients, 6 had well-correlated intratumor distributions of (18)F-FMISO-suggestive of chronic hypoxia. More work is required to identify the underlying causes of changes in intratumor distribution before single-time-point (18)F-FMISO PET images can be used as the basis of hypoxia-targeting intensity-modulated radiotherapy.
Assuntos
Hipóxia Celular/fisiologia , Neoplasias de Cabeça e Pescoço/metabolismo , Misonidazol/análogos & derivados , Tomografia por Emissão de Pósitrons/métodos , Radiossensibilizantes/farmacocinética , Idoso , Fluordesoxiglucose F18/farmacocinética , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Misonidazol/farmacocinética , Compostos Radiofarmacêuticos/farmacocinética , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X/métodosRESUMO
The development of positron emission tomography/computed tomography (PET/CT) scanners has allowed not only straightforward but also synergistic fusion of anatomical and functional information. Combined PET/CT imaging yields an increased sensitivity and specificity beyond that which either of the 2 modalities possesses separately and therefore provides improved diagnostic accuracy. Because attenuation correction in PET is performed with the use of CT images, with CT used in the localization of disease, accurate spatial registration of PET and CT image sets is required. Correcting for the spatial mismatch caused by respiratory motion represents a particular challenge for the requisite registration accuracy as a result of differences in temporal resolution between the 2 modalities. This review provides a brief summary of the materials, methods, and results involved in multiple investigations of the correction for respiratory motion in PET/CT imaging of the thorax, with the goal of improving image quality and quantitation. Although some schemes use respiratory-phase data selection to exclude motion artifacts, others have adopted sophisticated software techniques. The various image artifacts associated with breathing motion are also described.
Assuntos
Artefatos , Tomografia por Emissão de Pósitrons/tendências , Técnica de Subtração , Tórax/diagnóstico por imagem , Tomografia Computadorizada por Raios X/tendências , Humanos , Processamento de Imagem Assistida por Computador/tendências , Movimento (Física) , Mecânica Respiratória , Sensibilidade e EspecificidadeRESUMO
UNLABELLED: The goal of this study was to describe our initial experience with the deep-inspiration breath-hold (DIBH) technique in combined PET/CT of the thorax. This article presents particular emphasis on the technical aspects required for clinical implementation. METHODS: In the DIBH technique, the patient is verbally coached and brought to a reproducible deep inspiration breath-hold level. The first "Hold" period, which refers to the CT session, is considered as the reference. This is followed by 9- to 20-s independent breath-hold PET acquisitions. The goal is to correct for respiratory motion artifacts and, consequently, improve the tumor quantitation and localization on the PET/CT images and inflate the lungs for possible improvement in the detection of subcentimeter pulmonary nodules. A physicist monitors and records patient breathing during PET/CT acquisition using a motion tracker. Patient breathing traces obtained during acquisition are examined on the fly to assess the reproducibility of the technique. RESULTS: Data from 8 patients, encompassing 10 lesions, were analyzed. Visual inspection of fused PET/CT images showed improved spatial matching between the 2 modalities, reduced motion artifacts especially in the diaphragm, and increased the measured standardized uptake value (SUV) attributed to reduced motion blurring, as compared with the standard clinical PET/CT images. CONCLUSION: The practice of DIBH PET/CT is feasible in a clinical setting. With this technique, consistent lung inflation levels are achieved during PET/CT sessions, as judged by both motion tracker and verification of spatial matching between PET and CT images. Breathing-induced motion artifacts are significantly reduced using DIBH compared with free breathing, enabling better target localization and quantitation. The DIBH technique showed an increase in the median SUV by 32.46%, with a range from 4% to 83%, compared with SUVs measured on the clinical images. The median percentage reduction in the PET-to-CT lesions' centroids was 26.6% (range, 3%-50%).
Assuntos
Neoplasias Pulmonares/radioterapia , Tomografia por Emissão de Pósitrons/métodos , Respiração , Tórax/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Artefatos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Radiografia Torácica/métodos , Planejamento da Radioterapia Assistida por Computador , Tórax/patologia , Fatores de TempoRESUMO
Our previous patient studies have shown that the use of respiration averaged computed tomography (ACT) for attenuation correction of the positron emission tomography (PET) data from PET/CT reduces the potential misalignment in the thorax region by matching the temporal resolution of the CT to that of the PET. In the present work, we investigated other approaches of acquiring ACT in order to reduce the CT dose and to improve the ease of clinical implementation. Four-dimensional CT (4DCT) data sets for ten patients (17 lung/esophageal tumors) were acquired in the thoracic region immediately after the routine PET/CT scan. For each patient, multiple sets of ACTs were generated based on both phase image averaging (phase approach) and fixed cine duration image averaging (cine approach). In the phase approach, the ACTs were calculated from CT images corresponding to the significant phases of the respiratory cycle: ACT(050phs) from end-inspiration (0%) and end-expiration (50%), ACT(2070phs) from mid-inspiration (20%) and mid-expiration (70%), ACT(4phs) from 0%, 20%, 50% and 70%, and ACT(10phs) from all ten phases, which was the original approach. In the cine approach, which does not require 4DCT, the ACTs were calculated based on the cine images from cine durations of 1 to 6 s at 1 s increments. PET emission data for each patient were attenuation corrected with each of the above mentioned ACTs and the tumor maximum standard uptake value (SUVmax), average SUV (SUVavg), and tumor volume measurements were compared. Percent differences were calculated between PET data corrected with various ACTs and that corrected with ACT(10phs). In the phase approach, the ACT(10phs) can be approximated by the ACT(4phs) to within a mean percent difference of 2% in SUV and tumor volume measurements. In cine approach, ACT(10phs) can be approximated to within a mean percent difference of 3% by ACTs computed from cine durations > or =3 s. Acquiring CT images only at the four significant phases for the ACT can reduce radiation dose to 1/3 of the current 4DCT dose; however, the implementation of this approach requires additional hardware that is not standard equipment on PET/CT scanners. In the cine approach, we recommend a duration of 6 +/- 1 s in order to include variations of respiratory patterns in a larger population. This approach can be easily implemented because cine acquisition mode is available on all GE PET/CT scanners. The CT dose in the cine approach can be reduced to approximately 5 mGy by using the lowest mA setting (10 mA), while still maintaining good quality CT data for PET attenuation correction. In our scanning protocol, the ACT is only acquired if respiration-induced misregistration is observed (determined before the PET scan is completed), and therefore patients do not receive unnecessary CT radiation dose.
Assuntos
Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Tomografia por Emissão de Pósitrons/métodos , Mecânica Respiratória , Neoplasias Torácicas/diagnóstico , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Artefatos , Inteligência Artificial , Armazenamento e Recuperação da Informação/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Técnica de SubtraçãoRESUMO
BACKGROUND: It is estimated that 60 million computed tomography (CT) scans were performed during 2006, with approximately 11% of those performed on children age 0-15 years. Various types of gonadal shielding have been evaluated for reducing exposure to the gonads. The purpose of this study was to quantify the radiation dose reduction to the gonads and its effect on image quality when a wrap-around male pediatric gonad shield was used during CT scanning. This information is obtained to assist the attending radiologist in the decision to utilize such male gonadal shields in pediatric imaging practice. METHODS: The dose reduction to the gonads was measured for both direct radiation and for indirect scattered radiation from the abdomen. A 6 cm3 ion chamber (Model 10X5-6, Radcal Corporation, Monrovia, CA) was placed on a Humanoid real bone pelvic phantom at a position of the male gonads. When exposure measurements with shielding were made, a 1 mm lead wrap-around gonadal shield was placed around the ion chamber sensitive volume. RESULTS: The use of the shields reduced scatter dose to the gonads by a factor of about 2 with no appreciable loss of image quality. The shields reduced the direct beam dose by a factor of about 35 at the expense of extremely poor CT image quality due to severe streak artifacts. CONCLUSION: Images in the direct exposure case are not useful due to these severe artifacts and the difficulties in positioning these shields on patients in the scatter exposure case may not be warranted by the small absolute reduction in scatter dose unless it is expected that the patient will be subjected to numerous future CT scans.
Assuntos
Interpretação de Imagem Assistida por Computador/métodos , Proteção Radiológica/instrumentação , Radiografia Abdominal , Radiometria/métodos , Testículo , Tomografia Computadorizada Espiral , Adulto , Carga Corporal (Radioterapia) , Humanos , Masculino , Especificidade de Órgãos , Imagens de Fantasmas , Doses de Radiação , Proteção Radiológica/métodos , Eficiência Biológica Relativa , Reprodutibilidade dos Testes , Sensibilidade e EspecificidadeRESUMO
PURPOSE: (18)Fluorodeoxyglucose positron emission tomography (FDG PET) is widely used for the staging of lymphoma. We investigated whether the intensity of tumor FDG uptake could differentiate between indolent and aggressive disease. MATERIALS AND METHODS: PET studies of 97 patients with non-Hodgkin's lymphoma who were untreated or had relapsed and/or persistent disease and had not received treatment within the last 6 months were analyzed, and the highest standardized uptake value (SUV) per study was recorded. Correlations were made with histopathology. RESULTS: FDG uptake was lower in indolent than in aggressive lymphoma for patients with new (SUV, 7.0 +/- 3.1 v 19.6 +/- 9.3; P < .01) and relapsed (SUV, 6.3 +/- 2.7 v 18.1 +/- 10.9; P = .04) disease. Despite overlap between indolent and aggressive disease in the low SUV range (indolent, 2.3 to 13.0; aggressive, 3.2 to 43.0), all cases of indolent lymphoma had an SUV
Assuntos
Fluordesoxiglucose F18 , Linfoma não Hodgkin/diagnóstico por imagem , Tomografia por Emissão de Pósitrons , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Fluordesoxiglucose F18/farmacocinética , Humanos , Linfoma não Hodgkin/patologia , Masculino , Pessoa de Meia-Idade , Estadiamento de Neoplasias/métodos , Compostos Radiofarmacêuticos/farmacocinéticaRESUMO
UNLABELLED: (18)F-FDG PET has a high accuracy in staging head and neck cancer, but its role in patients with clinically and radiographically negative necks (N0) is less clear. In particular, the value of combined PET/CT has not been determined in this group of patients. METHODS: In a prospective study, 31 patients with oral cancer and no evidence of lymph node metastases by clinical examination or CT/MRI underwent (18)F-FDG PET/CT before elective neck dissection. PET/CT findings were recorded by neck side (left or right) and lymph node level. PET/CT findings were compared with histopathology of dissected nodes, which was the standard of reference. RESULTS: Elective neck dissections (26 unilateral, 5 bilateral; a total of 36 neck sides), involving 142 nodal levels, were performed. Only 13 of 765 dissected lymph nodes harbored metastases. Histopathology revealed nodal metastases in 9 of 36 neck sides and 9 of 142 nodal levels. PET was TP in 6 nodal levels (6 neck sides), false-negative in 3 levels (3 neck sides), true-negative in 127 levels (23 neck sides), and false-positive in 6 levels (4 neck sides). The 3 false-negative findings occurred in metastases smaller than 3 mm or because of inability to distinguish between primary tumor and adjacent metastasis. TP and false-positive nodes exhibited similar standardized uptakes (4.8 +/- 1.1 vs. 4.2 +/- 1.0; P = not significant). Sensitivity and specificity were 67% and 85% on the basis of neck sides and 67% and 95% on the basis of number of nodal levels, respectively. If a decision regarding the need for neck dissection had been based solely on PET/CT, 3 false-negative necks would have been undertreated, and 4 false-positive necks would have been overtreated. CONCLUSION: (18)F-FDG PET/CT can identify lymph node metastases in a segment of patients with oral cancer and N0 neck. A negative test can exclude metastatic deposits with high specificity. Despite reasonably high overall accuracy, however, the clinical application of PET/CT in the N0 neck may be limited by the combination of limited sensitivity for small metastatic deposits and a relatively high number of false-positive findings. The surgical management of the N0 neck should therefore not be based on PET/CT findings alone.
Assuntos
Fluordesoxiglucose F18/química , Neoplasias Bucais/diagnóstico , Neoplasias Bucais/radioterapia , Tomografia por Emissão de Pósitrons/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Reações Falso-Positivas , Feminino , Humanos , Metástase Linfática , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Metástase NeoplásicaRESUMO
The recently developed GATE (GEANT4 application for tomographic emission) Monte Carlo package, designed to simulate positron emission tomography (PET) and single photon emission computed tomography (SPECT) scanners, provides the ability to model and account for the effects of photon noncollinearity, off-axis detector penetration, detector size and response, positron range, photon scatter, and patient motion on the resolution and quality of PET images. The objective of this study is to validate a model within GATE of the General Electric (GE) Advance/Discovery Light Speed (LS) PET scanner. Our three-dimensional PET simulation model of the scanner consists of 12 096 detectors grouped into blocks, which are grouped into modules as per the vendor's specifications. The GATE results are compared to experimental data obtained in accordance with the National Electrical Manufactures Association/Society of Nuclear Medicine (NEMA/SNM), NEMA NU 2-1994, and NEMA NU 2-2001 protocols. The respective phantoms are also accurately modeled thus allowing us to simulate the sensitivity, scatter fraction, count rate performance, and spatial resolution. In-house software was developed to produce and analyze sinograms from the simulated data. With our model of the GE Advance/Discovery LS PET scanner, the ratio of the sensitivities with sources radially offset 0 and 10 cm from the scanner's main axis are reproduced to within 1% of measurements. Similarly, the simulated scatter fraction for the NEMA NU 2-2001 phantom agrees to within less than 3% of measured values (the measured scatter fractions are 44.8% and 40.9 +/- 1.4% and the simulated scatter fraction is 43.5 +/- 0.3%). The simulated count rate curves were made to match the experimental curves by using deadtimes as fit parameters. This resulted in deadtime values of 625 and 332 ns at the Block and Coincidence levels, respectively. The experimental peak true count rate of 139.0 kcps and the peak activity concentration of 21.5 kBq/cc were matched by the simulated results to within 0.5% and 0.1% respectively. The simulated count rate curves also resulted in a peak NECR of 35.2 kcps at 10.8 kBq/cc compared to 37.6 kcps at 10.0 kBq/cc from averaged experimental values. The spatial resolution of the simulated scanner matched the experimental results to within 0.2 mm.
Assuntos
Análise de Falha de Equipamento/métodos , Interpretação de Imagem Assistida por Computador/métodos , Modelos Biológicos , Método de Monte Carlo , Tomografia por Emissão de Pósitrons/instrumentação , Tomografia por Emissão de Pósitrons/métodos , Software , Algoritmos , Modelos Estatísticos , Reprodutibilidade dos Testes , Sensibilidade e EspecificidadeRESUMO
UNLABELLED: Attenuation correction (AC) of PET images with helical CT (HCT) in PET/CT matches only the spatial resolution of CT and PET, not the temporal resolution. We therefore proposed the use of respiration-averaged CT (ACT) to match the temporal resolution of CT and PET and evaluated the improvement of tumor quantification in PET images of the thorax with ACT. METHODS: First, we examined 100 consecutive clinical PET/CT studies for the frequency and magnitude of misalignment at the diaphragm position between the HCT and the PET data. Patients were injected with 555-740 MBq of (18)F-FDG and scanned 1 h after injection. The HCT data were acquired at the following settings: 120 kV, 300 mA, pitch of 1.35:1, collimation of 8 x 1.25 mm, and rotation cycle of 0.5 s. Patients were instructed to hold their breath at midexpiration during HCT of the thorax. The PET acquisition was 3 min per bed. Second, we retrospectively analyzed studies of 8 patients (1 with esophageal cancer and 7 with lung cancer). Each study included regular PET/CT followed by 4-dimensional (4D) CT for radiation treatment planning. We compared the results of AC of the PET data with HCT and ACT. There were 13 tumors in these 8 patients. The 4D CT data were acquired at the following settings: 120 kV, 50-150 mA, cine duration of 1 breathing cycle plus 1 s, collimation of 8 x 1.25 mm, and rotation cycle of 0.5 s. The acquisition was taken when the patient was in the free-breathing state. We averaged the 10 phases of the 4D CT data to obtain ACT for AC of the PET data. Both the ACT and the HCT data were used for AC of the same PET data. RESULTS: There was a misalignment between the HCT and the PET data in 50 of 100 patient studies. In 34 studies, the misalignment was greater than 2 cm. In a comparison of HCT and ACT, 5 tumors had differences in standardized uptake values (SUV) between HCT-and ACT-attenuation-corrected PET of less than 20%, and 4 tumors had differences in SUV of more than 50%. The latter 4 tumors were found in the patient with esophageal cancer and in 2 of the patients with lung cancer. The PET data from these 3 patients had a misalignment of 2-4.5 cm relative to the HCT data. Breathing artifacts were significantly reduced by ACT. Seven of the 8 patients had a lower diaphragm position on HCT than on ACT, suggesting that the patients tended to hold a deeper breath during HCT than during ACT. CONCLUSION: The high rate of misalignment suggested a potential mismatch between the HCT and the PET data with the limited-breath-hold CT protocol. In the comparison of HCT and ACT, significant differences (>50%) in SUV were attributable to different breathing states between HCT and PET. The PET data corrected by ACT did not show breathing artifacts, suggesting that ACT may be more accurate than HCT for AC of the PET data.
Assuntos
Artefatos , Aumento da Imagem/métodos , Neoplasias Pulmonares/diagnóstico , Movimento , Tomografia por Emissão de Pósitrons/métodos , Mecânica Respiratória , Tomografia Computadorizada Espiral/métodos , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Técnica de SubtraçãoRESUMO
Respiratory motion is known to affect the quantitation of 18FDG uptake in lung lesions. The aim of the study was to investigate the magnitude of errors in tracer activity determination due to motion, and its dependence upon CT attenuation at different phases of the motion cycle. To estimate these errors we have compared maximum activity concentrations determined from PET/CT images of a lung phantom at rest and under simulated respiratory motion. The NEMA 2001 IEC body phantom, containing six hollow spheres with diameters 37, 28, 22, 17, 13, and 10 mm, was used in this study. To mimic lung tissue density, the phantom (excluding spheres) was filled with low density polystyrene beads and water. The phantom spheres were filled with 18FDG solution setting the target-to-background activity concentration ratio at 8:1. PET/CT data were acquired with the phantom at rest, and while it was undergoing periodic motion along the longitudinal axis of the scanner with a range of displacement being 2 cm, and a period of 5 s. The phantom at rest and in motion was scanned using manufacturer provided standard helical/clinical protocol, a helical CT scan followed by a PET emission scan. The moving phantom was also scanned using a 4D-CT protocol that provides volume image sets at different phases of the motion cycle. To estimate the effect of motion on quantitation of activities in six spheres, we have examined the activity concentration data for (a) the stationary phantom, (b) the phantom undergoing simulated respiratory motion, and (c) a moving phantom acquired with PET/4D-CT protocol in which attenuation correction was performed with CT images acquired at different phases of motion cycle. The data for the phantom at rest and in motion acquired with the standard helical/clinical protocol showed that the activity concentration in the spheres can be underestimated by as much as 75%, depending on the sphere diameter. We have also demonstrated that fluctuations in sphere's activity concentration from one PET/CT scan to another acquired with standard helical/clinical protocol can arise as a consequence of spatial mismatch between the sphere's location in PET emission and the CT data.
Assuntos
Artefatos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Pulmão/diagnóstico por imagem , Movimento , Tomografia por Emissão de Pósitrons/métodos , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Humanos , Imageamento Tridimensional/métodos , Armazenamento e Recuperação da Informação/métodos , Pulmão/fisiologia , Imagens de Fantasmas , Reprodutibilidade dos Testes , Mecânica Respiratória , Sensibilidade e Especificidade , Técnica de SubtraçãoRESUMO
PURPOSE: We investigate the characteristics of lung tumor motion measured with respiration-correlated computed tomography (RCCT) and examine the method's applicability to radiotherapy planning and treatment. METHODS AND MATERIALS: Six patients treated for non-small-cell lung carcinoma received a helical single-slice computed tomography (CT) scan with a slow couch movement (1 mm/s), while simultaneously respiration is recorded with an external position-sensitive monitor. Another 6 patients receive a 4-slice CT scan in a cine mode, in which sequential images are acquired for a complete respiratory cycle at each couch position while respiration is recorded. The images are retrospectively resorted into different respiration phases as measured with the external monitor (4-slice data) or patient surface displacement observed in the images (single-slice data). The gross tumor volume (GTV) in lung is delineated at one phase and serves as a visual guide for delineation at other phases. Interfractional GTV variation is estimated by scaling diaphragm position variations measured in gated radiographs at treatment with the ratio of GTV:diaphragm displacement observed in the RCCT data. RESULTS: Seven out of 12 patients show GTV displacement with respiration of more than 1 cm, primarily in the superior-inferior (SI) direction; 2 patients show anterior-posterior displacement of more than 1 cm. In all cases, extremes in GTV position in the SI direction are consistent with externally measured extremes in respiration. Three patients show evidence of hysteresis in GTV motion, in which the tumor trajectory is displaced 0.2 to 0.5 cm anteriorly during expiration relative to inspiration. Significant (>1 cm) expansion of the GTV in the SI direction with respiration is observed in 1 patient. Estimated intrafractional GTV motion for gated treatment at end expiration is 0.6 cm or less in all cases; however; interfraction variation estimates (systematic plus random) are more than 1 cm in 3/9 patients. CONCLUSION: Respiration-correlated CT can be performed with currently available CT equipment and acquisition settings. RCCT provides not only three-dimensional information on intrafractional tumor motion and deformation, but also allows estimates of interfractional tumor variation when combined with radiographic measurements of diaphragm position variation during treatment.
Assuntos
Carcinoma Pulmonar de Células não Pequenas/diagnóstico por imagem , Neoplasias Pulmonares/diagnóstico por imagem , Movimento , Respiração , Tomografia Computadorizada por Raios X/métodos , Humanos , Planejamento da Radioterapia Assistida por ComputadorRESUMO
UNLABELLED: The standardized uptake value (SUV) is the most commonly used parameter to quantify the intensity of radiotracer uptake in tumors. Previous studies suggested that measurements of (18)F-FDG accumulation in tissue might be affected by the image reconstruction method, but the clinical relevance of these findings has not been assessed. METHODS: Phantom studies were performed and clinical whole-body (18)F-FDG PET images of 85 cancer patients were analyzed. All images were reconstructed using either filtered backprojection (FBP) with measured attenuation correction (MAC) or iterative reconstruction (IR) with segmented attenuation correction (SAC). In a subset of 15 patients, images were reconstructed using all 4 combinations of IR+SAC, IR+MAC, FBP+SAC, and FBP+MAC. For phantom studies, a sphere containing (18)F-FDG was placed in a water-filled cylinder and the activity concentration of that sphere was measured in FBP and IR reconstructed images using all 4 combinations. Clinical studies were displayed simultaneously and identical regions of interest (ROIs, 50 pixels) were placed in liver, urinary bladder, and tumor tissue in both image sets. SUV max (maximal counts per pixel in ROI) and SUV avg (average counts per pixel) were measured. RESULTS: In phantom studies, measurements from FBP images underestimated the true activity concentration to a greater degree than those from IR images (20% vs. 5% underestimation). In patient studies, SUV derived from FBP images were consistently lower than those from IR images in both normal and tumor tissue: Tumor SUV max with IR+SAC was 9.6 +/- 4.5, with IR+MAC it was 7.7 +/- 3.5, with FBP+MAC it was 6.9 +/- 3.0, and with FBP+SAC it was 8.6 +/- 4.1 (all P < 0.01 vs. IR+SAC). Compared with IR+SAC, SUV from FBP+MAC images were 25%-30% lower. Similar discrepancies were noted for liver and bladder. Discrepancies between measurements became more apparent with increasing (18)F-FDG concentration in tissue. CONCLUSION: SUV measurements in whole-body PET studies are affected by the applied methods for both image reconstruction and attenuation correction. This should be considered when serial PET studies are done in cancer patients. Moreover, if SUV is used for tissue characterization, different cutoff values should be applied, depending on the chosen method for image reconstruction and attenuation correction.
Assuntos
Algoritmos , Fluordesoxiglucose F18 , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Neoplasias/diagnóstico por imagem , Tomografia Computadorizada de Emissão/métodos , Contagem Corporal Total/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas , Compostos Radiofarmacêuticos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Tomografia Computadorizada de Emissão/instrumentação , Contagem Corporal Total/instrumentaçãoRESUMO
UNLABELLED: Results of performance measurements for a lutetium oxyorthosilicate (LSO)-based PET/CT scanner using new National Electrical Manufacturers Association (NEMA) NU 2-2001 standards are reported. METHODS: Performance measurements following the NU 2-2001 standards were performed on an LSO-based PET/CT scanner. In addition, issues associated with the application of the NEMA standard to LSO-based tomographs in the presence of intrinsic radiation are discussed. RESULTS: We report on some difficulties experienced in following the suggested NEMA measurement techniques and describe alternative approaches. Measurements with the new standard (as compared with NU-1994) incorporate the effects of activity outside the scanner and facilitate measurements of the entire axial field of view. Realistic clinical conditions are also simulated in image quality measurements of a torso phantom. CONCLUSION: We find that, with appropriate modifications, NU 2-2001 can be successfully applied to LSO-based scanners.
Assuntos
Câmaras gama/normas , Lutécio , Silicatos , Tomógrafos Computadorizados/normas , Tomografia Computadorizada de Emissão/instrumentação , Humanos , Imagens de Fantasmas , Cintilografia/instrumentação , Cintilografia/normas , Tomografia Computadorizada de Emissão/normas , Tomografia Computadorizada por Raios XRESUMO
UNLABELLED: This study proposes a new method to reduce respiratory motion artifacts in PET images of lung cancer. The method is referred to as respiratory-correlated dynamic PET (RCDPET). RCDPET enables the acquisition of 4-dimensional PET data without the need for a respiratory tracking device. In this article, we compare this method with respiratory-gated PET (RGPET). Both methods provide the ability to correct for motion artifacts and more accurately quantitate radiotracer uptake within lung lesions. Both methods were evaluated in phantom studies and 1 patient. METHODS: With RCDPET, data are acquired in consecutive 1-s time frames. A point source attached to a rigid foam block is set on the patient's abdomen and is extended into the camera field of view at the level of the lesion by means of a low-density rod. The position of this source is used to track respiratory motion through the consecutive dynamic frames. Image frames corresponding to a user-selected lesion position within the breathing cycle, in correlation with the point source position, are then identified after scanning. The sinograms of the selected image frames are summed and then reconstructed using iterative reconstruction with segmented attenuation correction. RESULTS: The results from phantom studies with both RGPET and RCDPET were within 10% agreement, for both activity quantitation and image noise levels. In a clinical application, the quantitation of the SUV(max) and the lesion's size showed a 6% and 2% difference, respectively, between RCDPET and RGPET measurements. CONCLUSION: RCDPET can be considered as a comparable, or alternative, method to RGPET in reducing the smearing effects due to respiration and improving quantitation of PET in the thorax. One advantage of RCDPET over RGPET is the ability to retrospectively reconstruct the PET data at any phase or amplitude in the breathing cycle.
Assuntos
Algoritmos , Artefatos , Aumento da Imagem/métodos , Neoplasias Pulmonares/diagnóstico por imagem , Movimento , Mecânica Respiratória , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Humanos , Aumento da Imagem/instrumentação , Interpretação de Imagem Assistida por Computador/instrumentação , Interpretação de Imagem Assistida por Computador/métodos , Masculino , Movimento (Física) , Imagens de Fantasmas , Projetos Piloto , Controle de Qualidade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Tomografia Computadorizada de Emissão de Fóton Único/instrumentaçãoRESUMO
UNLABELLED: Recent studies have shown increased artifacts in CT attenuation-corrected (CTAC) PET images acquired with oral contrast agents because of misclassification of contrast as bone. We have developed an algorithm, segmented contrast correction (SCC), to properly transform CT numbers in the contrast regions from CT energies (40-140 keV) to PET energy at 511 keV. METHODS: A bilinear transformation, equivalent to that supplied by the PET/CT scanner manufacturer, for the conversion of linear attenuation coefficients of normal tissues from CT to PET energies was optimized for BaSO(4) contrast agent. This transformation was validated by comparison with the linear attenuation coefficients measured for BaSO(4) at concentrations ranging from 0% to 80% at 511 keV for PET transmission images acquired with (68)Ge rod sources. In the CT images, the contrast regions were contoured to exclude bony structures and then segmented on the basis of a minimum threshold CT number (300 Hounsfield units). The CT number in each pixel identified with contrast was transformed into the corresponding effective bone CT number to produce the correct attenuation coefficient when the data were translated by the manufacturer software into PET energy during the process of CT attenuation correction. CT images were then used for attenuation correction of PET emission data. The algorithm was validated with a phantom in which a lesion was simulated within a volume of BaSO(4) contrast and in the presence of a human vertebral bony structure. Regions of interest in the lesion, bone, and contrast on emission PET images reconstructed with and without the SCC algorithm were analyzed. The results were compared with those for images obtained with (68)Ge-based transmission attenuation-corrected PET. RESULTS: The SCC algorithm was able to correct for contrast artifacts in CTAC PET images. In the phantom studies, the use of SCC resulted in an approximate 32% reduction in the apparent activity concentration in the lesion compared with data obtained from PET images without SCC and a <7.6% reduction compared with data obtained from (68)Ge-based attenuation-corrected PET images. In one clinical study, maximum standardized uptake value (SUV(max)) measurements for the lesion, bladder, and bowel were, respectively, 14.52, 13.63, and 13.34 g/mL in CTAC PET images, 59.45, 26.71, and 37.22 g/mL in (68)Ge-based attenuation-corrected PET images, and 11.05, 6.66, and 6.33 g/mL in CTAC PET images with SCC. CONCLUSION: Correction of oral contrast artifacts in PET images obtained by combined PET/CT yielded more accurate quantitation of the lesion and other, normal structures. The algorithm was tested in a clinical case, in which SUV(max) measurements showed discrepancies of 2%, 1.3%, and 5% between (68)Ge-based attenuation-corrected PET images and CTAC PET images with SCC for the lesion, bladder, and bowel, respectively. These values correspond to 6.5%, 62%, and 66% differences between CTAC-based measurements and (68)Ge-based ones.
Assuntos
Algoritmos , Artefatos , Sulfato de Bário , Meios de Contraste/administração & dosagem , Aumento da Imagem/métodos , Técnica de Subtração , Tomografia Computadorizada de Emissão/métodos , Tomografia Computadorizada por Raios X/métodos , Administração Oral , Sulfato de Bário/administração & dosagem , Estudos de Viabilidade , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas , Controle de Qualidade , Neoplasias Retais/diagnóstico por imagem , Espalhamento de Radiação , Tomografia Computadorizada de Emissão/instrumentação , Tomografia Computadorizada por Raios X/instrumentaçãoRESUMO
UNLABELLED: We have developed a new technique to gate lung 18F-FDG PET images in synchronization with the respiratory motion to reduce smearing due to breathing and improve quantitation of 18F-FDG uptake in lung lesions. METHODS: A camera-based respiratory gating system, the real-time position management (RPM), is used to monitor the respiratory cycle. The RPM provides a trigger to the PET scanner to initiate the gating cycle. Each respiratory cycle is divided into discrete bins triggered at a defined amplitude or phase within the patient's breathing motion, into which PET data are acquired. The acquired data within the time bins correspond to different lesion positions within the breathing cycle. The study includes 5 patients with lung cancer. RESULTS: Measurements of the lesions' volumes in the gated mode showed a reduction of up to 34% compared with that of the nongated measurement. This reduction in the lesion volume has been accompanied by an increase in the intensity in the 18F-FDG signal per voxel. This finding has resulted in an improvement in measurement of the maximum standardized uptake value (SUV(max)), which increased in 1 patient by as much as 159%. The total lesion glycolysis, defined as the product of the SUV(max) and the lesion volume, was also measured in gated and nongated modes and showed a consistency between the 2 measurements. CONCLUSION: We have shown that image smearing can be reduced by gating 18F-FDG PET images in synchronization with the respiratory motion. This technique allows a more accurate definition of the lesion volume and improves the quantitation specific activity of the tracer (in this case, 18F-FDG), which are distorted because of the breathing motion.
Assuntos
Fluordesoxiglucose F18 , Neoplasias Pulmonares/diagnóstico por imagem , Respiração , Tomografia Computadorizada de Emissão/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Artefatos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Compostos Radiofarmacêuticos , Tomografia Computadorizada de Emissão/instrumentaçãoRESUMO
UNLABELLED: We previously reported that respiratory motion is a major source of error in quantitation of lesion activity using combined PET/CT units. CT acquisition of the lesion occurs in seconds, rather than the 4-6 min required for PET emission scans. Therefore, an incongruent lesion position during CT acquisition will bias activity estimates using PET. In this study, we systematically analyzed the range of activity concentration changes, hence SUV, for lung lesions. METHODS: Five lung cancer patients were scanned with PET/CT. In CT, data were acquired in correlation with the real-time positioning. CT images were acquired, in cine mode, at 0.45-s intervals for slightly longer (1 s) than a full respiratory cycle at each couch position. Other scanning parameters were a 0.5-s gantry rotation, 140 kVp, 175 mA, 10-mm couch increments, and a 2.5-mm slice thickness. PET data were acquired after intravenous injection of about 444-555 MBq of (18)F-FDG with a 1-h uptake period. The scanning time was 3 min per bed position for PET. Regularity in breathing was assisted by audio coaching. A commercial software program was then used to sort the acquired CT images into 10 phases, with 0% corresponding to end of inspiration (EI) and 50% corresponding to end of expiration (EE). Using the respiration-correlated CT data, images were rebinned to match the PET slice locations and thickness. RESULTS: We analyzed 8 lesions from 5 patients. Reconstructed PET emission data showed up to a 24% variation in the lesion maximum standardized uptake values (SUVs) between EI and EE phases. Examination of all the phases showed an SUV variation of up to 30%. Also, in some cases the lesion showed up to a 9-mm shift in location and up to a 21% reduction in size when measured from PET during the EI phase, compared with during the EE phase. CONCLUSION: Using respiration-correlated CT for attenuation correction, we were able to quantitate the fluctuations in PET SUVs. Because those changes may lead to estimates of lower SUVs, the respiratory phase during CT transmission scanning needs to be measured or lung motion has to be regulated for imaging lung cancer in routine clinical practice.