Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 52
Filtrar
1.
Surg Endosc ; 37(9): 7039-7050, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37353654

RESUMO

BACKGROUND: Management of anastomotic leaks after Ivor-Lewis esophagectomy remains a challenge. Although intracavitary endoscopic vacuum therapy (EVT) has shown great efficacy for large dehiscences, the optimal management of smaller leaks has not been standardized. This study aims to compare EVT versus self-expandable metal stent (SEMS) in the treatment of leaks < 30 mm in size, due to the lack of current data on this topic. METHODS: Patients undergoing EVT (cases) or SEMS (controls) between May 2017 and July 2022 for anastomotic leaks < 3 cm following oncologic Ivor-Lewis esophagectomy were enrolled. Controls were matched in a 1:1 ratio based on age (± 3 years), BMI (± 3 kg/m2) and leak size (± 4 mm). RESULTS: Cases (n = 22) and controls (n = 22) showed no difference in baseline characteristics and leak size, as per matching at enrollment. No differences were detected between the two groups in terms of time from surgery to endoscopic treatment (p = 0.11) or total number of procedures per patient (p = 0.05). Remarkably, the two groups showed comparable results in terms of leaks resolution (90.9% vs. 72.7%, p = 0.11). The number of procedures per patient was not significant between the two cohorts (p = 0.05). The most frequent complication in the SEMS group was migration (15.3% of procedures). CONCLUSION: EVT and SEMS seem to have similar efficacy outcomes in the treatment of anastomotic defects < 30 mm after Ivor-Lewis esophagectomy. However, larger studies are needed to corroborate these findings.


Assuntos
Neoplasias Esofágicas , Tratamento de Ferimentos com Pressão Negativa , Stents Metálicos Autoexpansíveis , Humanos , Fístula Anastomótica/etiologia , Fístula Anastomótica/cirurgia , Esofagectomia/efeitos adversos , Esofagectomia/métodos , Estudos de Casos e Controles , Tratamento de Ferimentos com Pressão Negativa/efeitos adversos , Estudos Retrospectivos , Resultado do Tratamento , Stents Metálicos Autoexpansíveis/efeitos adversos , Anastomose Cirúrgica/efeitos adversos , Neoplasias Esofágicas/cirurgia , Neoplasias Esofágicas/complicações
2.
Surg Endosc ; 36(7): 5023-5031, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-34799745

RESUMO

BACKGROUND: Transoral incisionless fundoplication (TIF) with Medigus Ultrasonic Surgical Endostapler (MUSE) is a new intervention for treatment of gastro-esophageal reflux disease (GERD). We aimed at assessing the clinical, functional, and endoscopic effects of TIF by MUSE. METHODS: Forty-six patients underwent TIF. Proton pump inhibitor (PPI) consumption, GERD-health-related quality of life (HRQL) and reflux symptom index (RSI) questionnaires, upper gastrointestinal (GI) endoscopy, esophageal 24-h pH-impedance recording, and high-resolution manometry (HRM) were done before TIF and scheduled 6 and 12 months later (HRM only at 6-month). PPI consumption and symptoms were then assessed yearly. Data up to 3 years are reported in this study (PP- and ITT-analysis). RESULTS: TIF was successfully performed in 45/46 patients; in one patient esophageal intubation was impossible. Perforation occurred in two cases. One patient required surgery within 6 months. Clinical follow-up was available for 42 patients at 6 months and 1 year, 35 patients at 2 years, and 31 patients at 3 years. At 1, 2, and 3 years, PPI consumption was stopped, respectively, in 64.3%, 62.9%, and 74.2% of cases (ITT-analysis: 58.7%, 56.4%, and 65.7%). GERD-HRQL and RSI scores decreased at least 50%, respectively, in 71.5% and 76.2%, 71.4% and 68.6%, and 67.7% of cases (ITT-analysis: 65.2% and 69.6%, 64.1% and 61.5%, and 60%). A significant improvement of both scores was observed up to 3 years. 6-month and 1-year functional follow-up were possible in 31 and 20 patients. HRM showed significant increase of the median lower esophageal sphincter length and rate of peristaltic waves. Esophageal pH-impedance recording found significantly fewer acid, proximal and total refluxes, and percentage of esophageal pH < 4 total time at 6 months, but not at 1 year. CONCLUSION: TIF by MUSE significantly improved symptoms and PPIs consumption up to 3 years. However, esophagitis still persisted in one-third of cases at 1 year and functional improvement at 6 months was not confirmed at 1 year. Severe complications requiring surgery occurred in two cases. CLINICALTRIALS: GOV: ID: NCT03669874.


Assuntos
Esofagite Péptica , Refluxo Gastroesofágico , Alprostadil/uso terapêutico , Esofagite Péptica/tratamento farmacológico , Fundoplicatura/efeitos adversos , Refluxo Gastroesofágico/tratamento farmacológico , Humanos , Inibidores da Bomba de Prótons/uso terapêutico , Qualidade de Vida , Resultado do Tratamento , Ultrassom
3.
Esophagus ; 19(3): 417-425, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35347509

RESUMO

BACKGROUND: Endoscopic vacuum therapy (EVT) represents an effective endoscopic technique for the treatment of post-esophagectomy leaks and can be used after failure of primary treatment. We aimed to investigate endoscopic data and success rate of EVT for post-esophagectomy anastomotic leaks, after failed redo surgery or previous endoscopic treatment. METHODS: We retrospectively recruited 12 patients from January 2018 to October 2020. Success was defined as dehiscence closure at radiological and/or endoscopic evaluation. Ethical Committee of our institution approved the study. RESULTS: Twelve patients (66.7% male, mean age 65.08 ± 16.7 years) affected by esophago-gastric (n = 10) or esophago-jejunal (n = 2) anastomosis dehiscences after oncologic surgery were treated with EVT, after failure of previous redo-surgical (n = 3, 25%) or endoscopic management (n = 9, 75%). Technical success rate was 100% (60/60 procedures) and dehiscence closure was achieved in three quarters of patients (9/12, 75%). Regarding complications, one case of sponge dislocation (1/60 = 1.7%) and another case of delayed stricture after post-EVT stent placement (1/60 = 1.7%) were recorded, during a mean follow up of 182.3 days. CONCLUSIONS: EVT is a promising option in the treatment of the most complicated anastomotic dehiscences. Its use could be also considered after failure of previous endoscopic or surgical management.


Assuntos
Esofagectomia , Tratamento de Ferimentos com Pressão Negativa , Idoso , Idoso de 80 Anos ou mais , Anastomose Cirúrgica/efeitos adversos , Fístula Anastomótica/etiologia , Fístula Anastomótica/cirurgia , Esofagectomia/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Tratamento de Ferimentos com Pressão Negativa/efeitos adversos , Estudos Retrospectivos
9.
Sensors (Basel) ; 17(6)2017 Jun 11.
Artigo em Inglês | MEDLINE | ID: mdl-28604609

RESUMO

This paper introduces HighChest, an innovative smart freezer designed to promote energy efficient behavior and the responsible use of food. Introducing a novel human-machine interface (HMI) design developed through assessment phases and a user involvement stage, HighChest is state of the art, featuring smart services that exploit embedded sensors and Internet of things functionalities, which enhance the local capabilities of the appliance. The industrial design thinking approach followed for the advanced HMI is intended to maximize the social impact of the food management service, enhancing both the user experience of the product and the user's willingness to adopt eco- and energy-friendly behaviors. The sensor equipment realizes automatic recognition of food by learning from the users, as well as automatic localization inside the deposit space. Moreover, it provides monitoring of the appliance's usage, avoiding temperature and humidity issues related to improper use. Experimental tests were conducted to evaluate the localization system, and the results showed 100% accuracy for weights greater or equal to 0.5 kg. Drifts due to the lid opening and prolonged usage time were also measured, to implement automatic reset corrections.


Assuntos
Alimentos , Temperatura Baixa , Ecossistema , Internet
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA