Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
Respirology ; 18(7): 1135-42, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23714281

RESUMO

BACKGROUND AND OBJECTIVE: The use of continuous positive airway pressure (CPAP) treatment in patients with obesity hypoventilation syndrome (OHS) and obstructive sleep apnoea (OSA) was evaluated, and factors that might predict CPAP treatment failure were determined. METHODS: A sleep study was performed in 29 newly diagnosed, clinically stable OHS patients. CPAP treatment was commenced if the apnoea-hypopnoea index was >15. Lung function, night-time oximetry, blood adipokine and C-reactive protein levels were assessed prospectively on enrollment and after 3 months. Treatment failure at 3 months was defined as daytime arterial partial pressure of carbon dioxide (PaCO(2)) >45 mm Hg and/or oxygen saturation (SpO(2)) <90% for >30% of the night-time oximetry study. RESULTS: All patients had severe OSA (median apnoea-hypopnoea index = 74.7 (62-100) with a nocturnal mean SpO(2) of 81.4 ± 7), and all patients were treated with CPAP. The percentage of time spent below 90% saturation improved from 8.4% (0.0-39.0%) to 0.3% (0.4-4.0%). Awake PaCO(2) decreased from 50 (47-53) mm Hg to 43 (40-45) mm Hg. Seven patients failed CPAP treatment after 3 months. PaCO(2) at 1 month and mean night-time SpO(2) during the first night of optimal CPAP were associated with treatment failure at 3 months (odds ratio 1.4 (1.03-1.98); P = 0.034 and 0.6 (0.34-0.93); P = 0.027). CONCLUSIONS: CPAP treatment improves night-time oxygenation and daytime hypoventilation in selected clinically stable OHS patients who also have OSA. Patients with worse night-time saturation while on CPAP and higher daytime PaCO(2) at 1 month were more likely to fail CPAP treatment.


Assuntos
Pressão Positiva Contínua nas Vias Aéreas/métodos , Síndrome de Hipoventilação por Obesidade/terapia , Índice de Gravidade de Doença , Apneia Obstrutiva do Sono/terapia , Adipocinas/metabolismo , Idoso , Proteína C-Reativa/metabolismo , Dióxido de Carbono/metabolismo , Feminino , Humanos , Estudos Longitudinais , Masculino , Pessoa de Meia-Idade , Síndrome de Hipoventilação por Obesidade/metabolismo , Oximetria , Oxiemoglobinas/metabolismo , Polissonografia , Estudos Prospectivos , Estudos Retrospectivos , Apneia Obstrutiva do Sono/metabolismo , Resultado do Tratamento
2.
Front Neurosci ; 16: 838412, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35431793

RESUMO

Background: Down syndrome (DS) is a genetic form of Alzheimer's disease (AD) with a high prevalence of obstructive sleep apnea (OSA). These characteristics place the DS population as an optimal model to study the relationship between sleep and AD and to design clinical trials of preventive sleep therapies for AD. Regrettably, OSA treatment with continuous positive airway pressure (CPAP) is often neglected in adults with DS. In both clinical practice and research trials, it is usually presumed that these patients will not adapt to or tolerate the therapy. Study Objective: We aimed to evaluate the feasibility and long-term CPAP compliance in this population and their capacity to be enrolled in CPAP research studies. Methods: We prospectively compared the CPAP compliance of 17 OSA patients with DS and 19 age and sex matched OSA euploid patients. CPAP management and follow-up schedules were prescribed according to the habitual clinical practice. We compared group differences in tolerance, objective, and subjective hours of nightly CPAP usage at the 1st, 3rd, 6th, 12th, 24th, and 36th month visits. Good compliance was defined as at least 4 h use per night. We also investigated predictive factors of long-term CPAP compliance. Results: The percentage of DS subjects with good CPAP compliance (81.2 vs. 78.9%) and the objective CPAP use (5 vs. 6 h, p = 0.92) did not differ from the control group (CG). Subjective CPAP compliance was significantly higher in OSA patients with DS than in controls in all the follow-up visits (8 vs. 6.75 h, p = 0.001). The DS group had a significantly higher number of visits (9 vs. 5; p = 0.021) and mask changes (2.5 vs. 2; p = 0.05) than controls. Objective hours of CPAP use at the first follow-up visit predicted long-term CPAP compliance (p < 0.005). Conclusion: CPAP treatment is feasible and has good long-term compliance in OSA patients with DS. It should be recommended to improve health and prevent comorbidities. The DS population is indeed suitable to participate in longitudinal preventive sleep clinical trials for AD.

3.
Respir Care ; 47(8): 882-6, 2002 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-12162798

RESUMO

OBJECTIVE: Compare nighttime and daytime arterial blood gas values in patients undergoing long-term oxygen therapy (LTOT). METHODS: We studied 39 LTOT patients with chronic airflow limitation. Oxygen from an oxygen concentrator was administered via nasal prongs until daytime blood oxygen saturation (measured via pulse oximetry [S(pO2)]) was > or = 90%. Arterial blood samples were drawn at 6:00 PM, while the subject breathed room air, and also during oxygen administration at night (3:00 AM), early in the morning (7:00 AM), and at noon. S(pO2) was measured throughout the night. RESULTS: Mean patient age was 70 +/- 7 yr. All patients suffered severe chronic airflow limitation (mean forced expiratory volume in the first second 28 +/- 9% of predicted). The mean oxygen flow administered was 1.41 +/- 0.6 L/min. Mean overnight S(pO2) was 92 +/- 2.5%, with 21.5 +/- 28% of recording time under 90%. There were statistically significant differences between P(aO2), P(aCO2), and pH obtained at 3:00 AM and noon and between 7:00 AM and noon, while the patients breathed the same oxygen concentration. The differences between the 3:00 and 7:00 AM values were not significant. In 23 patients (59%) we observed a P(aCO2) increase > 10 mm Hg and/or a pH decrease to < 7.33 during that period, indicating poor response to LTOT. CONCLUSIONS: Daytime arterial blood gas measurements do not reflect nighttime gas exchange. However, samples taken early in the morning (7:00 AM) do seem to reflect arterial blood gases during the night and can therefore be used for setting and monitoring nighttime oxygen flow.


Assuntos
Ritmo Circadiano , Pneumopatias Obstrutivas/terapia , Oxigenoterapia , Oxigênio/sangue , Troca Gasosa Pulmonar/fisiologia , Sono/fisiologia , Idoso , Feminino , Humanos , Hipercapnia/fisiopatologia , Assistência de Longa Duração , Pneumopatias Obstrutivas/sangue , Pneumopatias Obstrutivas/fisiopatologia , Masculino
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA