Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
Mais filtros

Base de dados
Tipo de documento
País/Região como assunto
Intervalo de ano de publicação
1.
Opt Express ; 26(23): 30532-30545, 2018 Nov 12.
Artigo em Inglês | MEDLINE | ID: mdl-30469951

RESUMO

Analog photonic links require high-fidelity, high-speed optical-to-electrical conversion for applications such as radio-over-fiber, synchronization at kilometer-scale facilities, and low-noise electronic signal generation. Photodetector nonlinearity is a particularly vexing problem, causing signal distortion and excess noise, especially in systems utilizing ultrashort optical pulses. Here we show that photodetectors designed for high power handling and high linearity can perform optical-to-electrical conversion of ultrashort optical pulses with unprecedented linearity over a large photocurrent range. We also corroborate and expand upon the physical understanding of how the broadband, complex impedance of the circuit following the photodiode modifies the linearity - in some cases quite significantly. By externally manipulating the circuit impedance, we extend the detector's linear range to higher photocurrents, with over 50 dB rejection of amplitude-to-phase conversion for photocurrents up to 40 mA. This represents a 1000-fold improvement over state-of-the-art photodiodes and significantly extends the attainable microwave power by a factor of four. As such, we eliminate the long-standing requirement in ultrashort pulse detection of precise tuning of the photodiode's operating parameters to coincide with a nonlinearity minimum. These results should also apply more generally to reduce nonlinear distortion in a range of other microwave photonics applications.

2.
Opt Lett ; 42(7): 1277-1280, 2017 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-28362748

RESUMO

We demonstrate an easy-to-manufacture 25-mm-long ultra-stable optical reference cavity for transportable photonic microwave generation systems. Employing a rigid holding geometry that is first-order insensitive to the squeezing force and a cavity geometry that improves the thermal noise limit at room temperature, we observe a laser phase noise that is nearly thermal noise limited for three frequency decades (1 Hz to 1 kHz offset) and supports 10 GHz generation with phase noise near -100 dBc/Hz at 1 Hz offset and <-173 dBc/Hz for all offsets >600 Hz. The fractional frequency stability reaches 2×10-15 at 0.1 s of averaging.

3.
Phys Rev Lett ; 119(25): 253001, 2017 Dec 22.
Artigo em Inglês | MEDLINE | ID: mdl-29303326

RESUMO

Optical clocks benefit from tight atomic confinement enabling extended interrogation times as well as Doppler- and recoil-free operation. However, these benefits come at the cost of frequency shifts that, if not properly controlled, may degrade clock accuracy. Numerous theoretical studies have predicted optical lattice clock frequency shifts that scale nonlinearly with trap depth. To experimentally observe and constrain these shifts in an ^{171}Yb optical lattice clock, we construct a lattice enhancement cavity that exaggerates the light shifts. We observe an atomic temperature that is proportional to the optical trap depth, fundamentally altering the scaling of trap-induced light shifts and simplifying their parametrization. We identify an "operational" magic wavelength where frequency shifts are insensitive to changes in trap depth. These measurements and scaling analysis constitute an essential systematic characterization for clock operation at the 10^{-18} level and beyond.

4.
Science ; 367(6485): 1458-1461, 2020 03 27.
Artigo em Inglês | MEDLINE | ID: mdl-32217722

RESUMO

Spectroscopy is a powerful tool for studying molecules and is commonly performed on large thermal molecular ensembles that are perturbed by motional shifts and interactions with the environment and one another, resulting in convoluted spectra and limited resolution. Here, we use quantum-logic techniques to prepare a trapped molecular ion in a single quantum state, drive terahertz rotational transitions with an optical frequency comb, and read out the final state nondestructively, leaving the molecule ready for further manipulation. We can resolve rotational transitions to 11 significant digits and derive the rotational constant of 40CaH+ to be B R = 142 501 777.9(1.7) kilohertz. Our approach is suited for a wide range of molecular ions, including polyatomics and species relevant for tests of fundamental physics, chemistry, and astrophysics.

5.
Opt Express ; 17(5): 3331-40, 2009 Mar 02.
Artigo em Inglês | MEDLINE | ID: mdl-19259170

RESUMO

We use a Fabry-Perot cavity to optically filter the output of a Ti:sapphire frequency comb to integer multiples of the original 1 GHz mode spacing. This effectively increases the pulse repetition rate, which is useful for several applications. In the case of low-noise microwave signal generation, such filtering leads to improved linearity of the high-speed photodiodes that detect the mode-locked laser pulse train. The result is significantly improved signal-to-noise ratio at the 10 GHz harmonic with the potential for a shot-noise limited single sideband phase noise floor near -168 dBc/Hz.

6.
Opt Express ; 14(20): 9531-6, 2006 Oct 02.
Artigo em Inglês | MEDLINE | ID: mdl-19529340

RESUMO

We demonstrate an octave-spanning, self-referenced optical frequency comb produced with a high-repetition-rate (frep=585 MHz) femtosecond Ti:Sapphire laser that requires less than 1 W of 532 nm pump power. The frequency comb was stabilized to a CW laser as required for optical clocks and low noise frequency synthesis. These results should be relevant for applications that require more-compact and efficient frequency combs.

7.
Electron Lett ; 51(20): 1596-1598, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26865734

RESUMO

We investigate the low timing jitter properties of a tunable single-pass optoelectronic frequency comb generator. The scheme is flexible in that both the repetition rate and center frequency can be continuously tuned. When operated with 10 GHz comb spacing, the integrated residual pulse-to-pulse timing jitter is 11.35 fs (1 Hz to 10 MHz) with no feedback stabilization. The corresponding phase noise at 1 Hz offset from the photodetected 10 GHz carrier is -100 dBc/Hz.

8.
Opt Lett ; 34(7): 872-4, 2009 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-19340155

RESUMO

Optical filtering of a stabilized 1 GHz optical frequency comb produces a 20 GHz comb with approximately 40 nm bandwidth (FWHM) at 960 nm. Use of a low-finesse Fabry-Pérot cavity in a double-pass configuration provides a broad cavity coupling bandwidth (Deltalambda/lambda approximately 10%) and large suppression (50 dB) of unwanted modes. Pulse durations shorter than 40 fs with less than 2% residual amplitude modulation are achieved.

9.
Phys Rev Lett ; 103(6): 063001, 2009 Aug 07.
Artigo em Inglês | MEDLINE | ID: mdl-19792559

RESUMO

We experimentally investigate an optical clock based on ;{171}Yb (I = 1/2) atoms confined in an optical lattice. We have evaluated all known frequency shifts to the clock transition, including a density-dependent collision shift, with a fractional uncertainty of 3.4 x 10;{-16}, limited principally by uncertainty in the blackbody radiation Stark shift. We measured the absolute clock transition frequency relative to the NIST-F1 Cs fountain clock and find the frequency to be 518 295 836 590 865.2(0.7) Hz.

10.
Science ; 324(5925): 360-3, 2009 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-19372424

RESUMO

At ultracold temperatures, the Pauli exclusion principle suppresses collisions between identical fermions. This has motivated the development of atomic clocks with fermionic isotopes. However, by probing an optical clock transition with thousands of lattice-confined, ultracold fermionic strontium atoms, we observed density-dependent collisional frequency shifts. These collision effects were measured systematically and are supported by a theoretical description attributing them to inhomogeneities in the probe excitation process that render the atoms distinguishable. This work also yields insights for zeroing the clock density shift.

11.
Phys Rev Lett ; 100(10): 103002, 2008 Mar 14.
Artigo em Inglês | MEDLINE | ID: mdl-18352181

RESUMO

We present an experimental study of the lattice-induced light shifts on the (1)S(0) --> (3)P(0) optical clock transition (nu(clock) approximately 518 THz) in neutral ytterbium. The "magic" frequency nu(magic) for the 174Yb isotope was determined to be 394 799 475(35) MHz, which leads to a first order light shift uncertainty of 0.38 Hz. We also investigated the hyperpolarizability shifts due to the nearby 6s6p(3)P(0) --> 6s8p(3)P(0), 6s8p(3)P(2), and 6s5f(3)F(2) two-photon resonances at 759.708, 754.23, and 764.95 nm, respectively. By measuring the corresponding clock transition shifts near these two-photon resonances, the hyperpolarizability shift was estimated to be 170(33) mHz for a linear polarized, 50 microK deep, lattice at the magic wavelength. These results indicate that the differential polarizability and hyperpolarizability frequency shift uncertainties in a Yb lattice clock could be held to well below 10(-17).

12.
Science ; 319(5871): 1808-12, 2008 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-18323415

RESUMO

Time has always had a special status in physics because of its fundamental role in specifying the regularities of nature and because of the extraordinary precision with which it can be measured. This precision enables tests of fundamental physics and cosmology, as well as practical applications such as satellite navigation. Recently, a regime of operation for atomic clocks based on optical transitions has become possible, promising even higher performance. We report the frequency ratio of two optical atomic clocks with a fractional uncertainty of 5.2 x 10(-17). The ratio of aluminum and mercury single-ion optical clock frequencies nuAl+/nuHg+ is 1.052871833148990438(55), where the uncertainty comprises a statistical measurement uncertainty of 4.3 x 10(-17), and systematic uncertainties of 1.9 x 10(-17) and 2.3 x 10(-17) in the mercury and aluminum frequency standards, respectively. Repeated measurements during the past year yield a preliminary constraint on the temporal variation of the fine-structure constant alpha of alpha/alpha = (-1.6+/-2.3) x 10(-17)/year.

13.
Science ; 319(5871): 1805-8, 2008 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-18276849

RESUMO

Optical atomic clocks promise timekeeping at the highest precision and accuracy, owing to their high operating frequencies. Rigorous evaluations of these clocks require direct comparisons between them. We have realized a high-performance remote comparison of optical clocks over kilometer-scale urban distances, a key step for development, dissemination, and application of these optical standards. Through this remote comparison and a proper design of lattice-confined neutral atoms for clock operation, we evaluate the uncertainty of a strontium (Sr) optical lattice clock at the 1 x 10(-16) fractional level, surpassing the current best evaluations of cesium (Cs) primary standards. We also report on the observation of density-dependent effects in the spin-polarized fermionic sample and discuss the current limiting effect of blackbody radiation-induced frequency shifts.

14.
Phys Rev Lett ; 98(7): 070801, 2007 Feb 16.
Artigo em Inglês | MEDLINE | ID: mdl-17359009

RESUMO

We report tests of local position invariance and the variation of fundamental constants from measurements of the frequency ratio of the 282-nm 199Hg+ optical clock transition to the ground state hyperfine splitting in 133Cs. Analysis of the frequency ratio of the two clocks, extending over 6 yr at NIST, is used to place a limit on its fractional variation of <5.8x10(-6) per change in normalized solar gravitational potential. The same frequency ratio is also used to obtain 20-fold improvement over previous limits on the fractional variation of the fine structure constant of |alpha/alpha|<1.3x10(-16) yr-1, assuming invariance of other fundamental constants. Comparisons of our results with those previously reported for the absolute optical frequency measurements in H and 171Yb+ vs other 133Cs standards yield a coupled constraint of -1.5x10(-15)

15.
Phys Rev Lett ; 98(22): 220801, 2007 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-17677830

RESUMO

We report, for the first time, laser spectroscopy of the 1S0-->3P0 clock transition in 27Al+. A single aluminum ion and a single beryllium ion are simultaneously confined in a linear Paul trap, coupled by their mutual Coulomb repulsion. This coupling allows the beryllium ion to sympathetically cool the aluminum ion and also enables transfer of the aluminum's electronic state to the beryllium's hyperfine state, which can be measured with high fidelity. These techniques are applied to measure the clock transition frequency nu=1,121,015,393,207,851(6) Hz. They are also used to measure the lifetime of the metastable clock state tau=20.6+/-1.4 s, the ground state 1S0 g factor gS=-0.000,792,48(14), and the excited state 3P0 g factor gP=-0.001,976,86(21), in units of the Bohr magneton.

16.
Opt Lett ; 31(7): 1011-3, 2006 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-16599240

RESUMO

We demonstrate a self-referenced, octave-spanning, mode-locked Ti:sapphire laser with a scalable repetition rate (550 MHz - 1.35 GHz). We use the frequency comb output of the laser, without additional broadening in optical fiber, for simultaneous measurements against atomic optical standards at 534, 578, 563, and 657 nm and to stabilize the laser offset frequency.

17.
Phys Rev Lett ; 97(16): 163905, 2006 Oct 20.
Artigo em Inglês | MEDLINE | ID: mdl-17155398

RESUMO

We have performed sub-Doppler spectroscopy on the narrow intercombination line of cold calcium atoms using the amplified output of a femtosecond laser frequency comb. Injection locking of a 657-nm diode laser with a femtosecond comb allows for two regimes of amplification, one in which many lines of the comb are amplified, and one where a single line is predominantly amplified. The output of the laser in both regimes was used to perform kilohertz-level spectroscopy. This experiment demonstrates the potential for high-resolution absolute-frequency spectroscopy over the entire spectrum of the frequency comb output using a single high-finesse optical reference cavity.

18.
Phys Rev Lett ; 97(2): 020801, 2006 Jul 14.
Artigo em Inglês | MEDLINE | ID: mdl-16907426

RESUMO

For the past 50 years, atomic standards based on the frequency of the cesium ground-state hyperfine transition have been the most accurate time pieces in the world. We now report a comparison between the cesium fountain standard NIST-F1, which has been evaluated with an inaccuracy of about 4 x 10(-16), and an optical frequency standard based on an ultraviolet transition in a single, laser-cooled mercury ion for which the fractional systematic frequency uncertainty was below 7.2 x 10(-17). The absolute frequency of the transition was measured versus cesium to be 1,064,721,609,899,144.94 (97) Hz, with a statistically limited total fractional uncertainty of 9.1 x 10(-16) the most accurate absolute measurement of an optical frequency to date.

19.
Phys Rev Lett ; 95(8): 083003, 2005 Aug 19.
Artigo em Inglês | MEDLINE | ID: mdl-16196856

RESUMO

We report the direct excitation of the highly forbidden (6s2) 1S0 <--> (6s6p) 3P0 optical transition in two odd isotopes of neutral ytterbium. As the excitation laser frequency is scanned, absorption is detected by monitoring the depletion from an atomic cloud at approximately 70 microK in a magneto-optical trap. The measured frequency in 171Yb (F=1/2) is 518,295,836,591.6 +/- 4.4 kHz. The measured frequency in 173Yb (F=5/2) is 518,294,576,847.6 +/- 4.4 kHz. Measurements are made with a femtosecond-laser frequency comb calibrated by the National Institute of Standards and Technology cesium fountain clock and represent nearly a 10(6)-fold reduction in uncertainty. The natural linewidth of these J=0 to J=0 transitions is calculated to be approximately 10 mHz, making them well suited to support a new generation of optical atomic clocks based on confinement in an optical lattice.

20.
Opt Lett ; 30(7): 735-7, 2005 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-15832922

RESUMO

We demonstrate carrier-envelope phase stabilization of a mode-locked Ti:sapphire laser by use of quantum interference control of injected photocurrents in a semiconductor. No harmonic generation is required for this stabilization technique. Instead, interference between coexisting single- and two-photon absorption pathways in the semiconductor provides a phase comparison between different spectral components. The phase comparison, and the detection of the photocurrent that it produces, both occur within a single low-temperature-grown gallium arsenide sample. The carrier-envelope offset beat note fidelity is 30 dB in a 10-kHz resolution bandwidth. The out-of-loop phase-noise level is essentially identical to the best previous measurements with the standard self-referencing technique.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA