Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 45
Filtrar
1.
Catheter Cardiovasc Interv ; 102(5): 896-899, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37746918

RESUMO

Despite improvements in current devices and techniques for complex chronic total occlusion (CTO) percutaneous coronary intervention (PCI), procedural complications, including coronary perforation, still occur and could be life-threatening. A patient with a history of multivessel coronary artery disease and a CTO of the right coronary artery (RCA) underwent successful retrograde crossing of an RCA CTO. After wiring the CTO body and lesion dilatation, a drug-eluting stent was implanted in the distal RCA toward the posterior descending artery. A large Ellis type III perforation occurred at the distal edge of the stent. Septal crossing with a balloon and tamponade of the perforation site through the retrograde collaterals followed, as the RCA was not suitable to accommodate easily both the covered stent and the balloon simultaneously. This case report presents a novel approach the "septal retrograde ping-pong" technique, which demonstrates successful treatment of coronary perforations by utilizing a retrograde approach through a septal collateral. This technique proves to be effective in situations where the conventional antegrade balloon or covered stent delivery methods are not feasible or unsuccessful. This innovative approach offers a promising alternative for managing challenging cases of coronary perforations, providing new insights and potential solutions for interventional cardiologists.


Assuntos
Oclusão Coronária , Stents Farmacológicos , Intervenção Coronária Percutânea , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/métodos , Angiografia Coronária , Resultado do Tratamento , Circulação Colateral , Oclusão Coronária/diagnóstico por imagem , Oclusão Coronária/terapia , Doença Crônica
2.
Catheter Cardiovasc Interv ; 101(5): 911-917, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36856010

RESUMO

BACKGROUND: Chronic total occlusion (CTO) revascularization is a major source of radiation for both patients and physicians. Therefore, efforts to minimize radiation during CTO percutaneous coronary intervention (PCI) are highly encouraged. AIMS: To evaluate the impact of an Ultra Low fluoroscopic Dose Protocol (ULDP), based on 3.75 frames per second for the fluoroscopy and 7.5 frames per second for the cine acquisition, during CTO PCI. METHODS: One hundred fifty consecutive patients who underwent CTO PCI were retrospectively enrolled. Eighty-five underwent standard dose protocol (SDP) and 65 ULDP. Radiation exposure and acute clinical outcomes were compared between groups. Results were stratified according to lesion complexity. RESULTS: Patients undergoing ULDP, as compared to those undergoing SDP, showed a significant reduction of kerma area product, both for simple lesions (6861.0 vs. 13236.0 mGy × cm2 ; p = 0.014) and complex lesions (CL) (8865.0 vs. 16618.0 mGy × cm2 ; p < 0.001). Similarly, Air Kerma (AK) was lower when ULDP was used (1222.5 vs. 2015.0 cGy in SL, p = 0.134; 1499.0 vs. 2794.0 cGy in CL, p < 0.001). No significant differences were reported regarding procedural success and in-hospital major adverse cardiovascular events between groups. Notably, there was not any crossover from ULDO to SDP due to poor quality images. Interestingly, fluoroscopy time, procedural time and contrast volume was significantly lower in patients undergoing ULDP only for CLs. CONCLUSIONS: ULDP significantly reduces radiation exposure in the setting of high complexity procedures such as CTO PCI. This reduction seemed to be greater with increased procedural complexity and did not impact acute success or adverse clinical events.


Assuntos
Oclusão Coronária , Fluoroscopia , Intervenção Coronária Percutânea , Humanos , Doença Crônica , Angiografia Coronária/efeitos adversos , Angiografia Coronária/métodos , Oclusão Coronária/diagnóstico por imagem , Oclusão Coronária/terapia , Oclusão Coronária/etiologia , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/métodos , Sistema de Registros , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento
3.
Catheter Cardiovasc Interv ; 101(4): 798-805, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36841945

RESUMO

OBJECTIVES: The objective of this study is to investigate the use of cutting balloon (CB) inflated at high pressure compared with noncompliant balloon (NCB) for the treatment of calcified coronary lesions. BACKGROUND: No data are available regarding the safety and efficacy of CB inflated at high pressure in coronary artery calcifications. METHODS: Patients with calcified lesions (more than 100° of calcium demonstrated at baseline intravascular ultrasound) were randomized. Primary endpoint of the study was the final minimal stent area (MSA) and stent symmetry in the calcific segment. Secondary endpoints included rate of device failure and the 1-year rate of target lesion revascularization, target vessel revascularization, and major adverse cardiovascular events. RESULTS: From September 2019 to June 2021, a total of 100 patients were included and randomized; 13 patients were excluded for major protocol deviations. Lesions were complex (type B2/C n = 61 [71.2%]) with a mean arch of calcium of 266 ± 84°, a calcium length of 12 ± 6.6 mm. CB was inflated at comparable atmospheres when compared with NCB (18.3 ± 5 vs. 19 ± 4.5, p = 0.46). In the per-protocol population, the final MSA at the level of the calcium site was significantly higher in the CB group (8.1 ± 2 vs. 7.3 ± 2.1, p = 0.035) with a higher eccentricity index achieved in the CB group (0.84 ± 0.07 vs. 0.8 ± 0.08, p = 0.013). Three device failure occurred in the CB group. One-year follow-up outcomes were comparable. CONCLUSIONS: Treatment of calcified lesions with high-pressure CB has a good safety profile and is associated with a larger MSA and higher eccentricity of the stent at the level of the calcium site compared with NCB.


Assuntos
Angioplastia Coronária com Balão , Doença da Artéria Coronariana , Humanos , Angiografia Coronária , Cálcio , Resultado do Tratamento , Doença da Artéria Coronariana/terapia , Stents
4.
J Interv Cardiol ; 2023: 7958808, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37560012

RESUMO

Background: In the setting of coronary artery dissection, both spontaneous and iatrogenic, fixing the intimal tear, usually with stent implantation, can be extremely challenging if the distal wire position has been lost. Common complications are mainly related to the inadvertent subintimal tracking of the guidewire while attempting to gain the distal true lumen. Aims: To report the registry results of using the SUOH 0.3 guidewire for managing coronary artery dissection in a real-world multicenter setting. Methods: The study population in this retrospective, multicenter, international registry included 75 consecutive patients who underwent PCI and required an antegrade wiring of a dissected coronary artery. Results: Successful use of SUOH 0.3 was achieved in 69 (92%) patients. The use of a microcatheter was associated with a significantly higher rate of TIMI 3 flow at the end of the procedure (no microcatheter: n = 17, 81%; microcatheter: n = 52, 96.3%; p = 0.017). The first recanalization attempt was made with the SUOH 03 guidewire in 48 (64%) cases, and it was successful in 42 (87%). The overall PCI success rate was reported in 72 (96%) patients, with no significant differences among patients with different origins, mechanisms, and locations of dissection. Conclusions: In this setting, the SUOH 0.3 guidewire provides high procedural success without additional complex techniques.


Assuntos
Oclusão Coronária , Intervenção Coronária Percutânea , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/métodos , Resultado do Tratamento , Oclusão Coronária/etiologia , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/cirurgia , Estudos Retrospectivos , Angiografia Coronária , Doença Crônica , Sistema de Registros
5.
Catheter Cardiovasc Interv ; 99(6): 1766-1777, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35312151

RESUMO

INTRODUCTION: Device entrapment is a life-threatening complication during percutaneous coronary intervention (PCI). However, the success for its management is predominantly based on operator experience with limited available guidance in the published literature. METHODS: A systematic review was performed on December 2021; we searched PubMed for articles on device entrapment during PCI. In addition, backward snowballing (i.e., review of references from identified articles and pertinent reviews) was employed. RESULTS: A total of 4209 articles were retrieved, of which 150 studies were included in the synthesis of the data. A methodical algorithmic approach to prevention and management of device entrapment can help to optimize outcomes. The recommended sequence of steps are as follows: (a) pulling, (b) trapping, (c) snaring, (d) plaque modification, (e) telescoping, and (f) surgery. CONCLUSIONS: In-depth knowledge of the techniques and necessary tools can help optimize the likelihood of successful equipment retrieval and minimization of complications.


Assuntos
Intervenção Coronária Percutânea , Placa Aterosclerótica , Humanos , Resultado do Tratamento
6.
Catheter Cardiovasc Interv ; 98(2): 238-245, 2021 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-32857911

RESUMO

OBJECTIVES AND BACKGROUND: Coronary artery perforation (CAP) is a potentially life-threatening complication during percutaneous coronary interventions (PCI) and the best strategy for its management is yet to be proved. We aimed to analyze the safety, efficacy, and long-term clinical outcomes of the block and deliver (BAD) technique, as only anecdotal cases are reported in literature. METHODS: From January 2016 to January 2020, all consecutive patients treated with the BAD technique at five high-volume centers in Italy were retrospectively identified. RESULTS: 25 CAPs treated with the BAD technique were included. The most frequently perforated artery was the left anterior descending artery (32%) and spring-coil wires with a hydrophilic coating were the most common culprit wires (68%). Mean sealing time was 46.9 ± 60.1 min, with no significant differences between CTO-PCIs and non-CTO PCIs (p = .921). Acute successful sealing of the CAP was achieved in 96% of the cases. Immediate cardiac tamponade occurred in 28% of patients, four during CTO PCI and three during non-CTO PCI (p = .55). Two patients required pericardiocentesis during hospitalization, one patient developed acute kidney injury, and one patient underwent cardiac surgery due to severe mitral regurgitation. At 1-year follow-up no significant differences were observed between groups in terms of POCE (25 vs 25%, p = .628) and its individual components. CONCLUSION: The BAD technique proved to be effective for the management of CAP, showing high successful sealing rates. Rates of in-hospital events and at 1-year follow-up did not significantly differ between patients suffering CAP during CTO revascularization or during non-CTO PCI.


Assuntos
Oclusão Coronária , Intervenção Coronária Percutânea , Doença Crônica , Oclusão Coronária/diagnóstico por imagem , Oclusão Coronária/cirurgia , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/cirurgia , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Sistema de Registros , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
7.
Catheter Cardiovasc Interv ; 97(6): E817-E825, 2021 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-32865855

RESUMO

Balloon uncrossable coronary lesions are lesions that cannot be crossed with a balloon after successful guidewire crossing. The strategies used to facilitate the treatment of such lesions can be classified into strategies that provide lesion modification and strategies that increase support. We describe a systematic, algorithmic approach to treat balloon uncrossable lesions, starting with use of small balloons, followed by increase in guide catheter support, use of microcatheters, wire cutting or puncture techniques, laser, atherectomy, and subintimal modification techniques. Sequential and simultaneous application of the aforementioned techniques can result in successful treatment of these challenging lesions.


Assuntos
Angioplastia Coronária com Balão , Oclusão Coronária , Angioplastia Coronária com Balão/efeitos adversos , Doença Crônica , Angiografia Coronária , Humanos , Resultado do Tratamento
8.
Catheter Cardiovasc Interv ; 96(4): E462-E466, 2020 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-32187801

RESUMO

Coronary artery dissection is a well-known complication of percutaneous coronary interventions. In this setting, coronary artery dissection is caused by mechanical injury of the arterial wall. However, dissection may also occur spontaneously. In both situations, an intimal tear or dissection allows blood entering and separating the layers of the coronary arterial wall. Despite percutaneous approach is still the preferred and the quickest way to restore coronary flow, it remains challenging. One of the main reasons for procedural failure is due to the difficult advancement of a guidewire into the true lumen. In such situation, the ideal wire should have a soft tip, high torque control, and excellent flexibility. Assuming that, the "new rope coil" composite core Suoh 0.3 guidewire, with its unique combination of characteristics, could allow better orientation insight into a dissected coronary artery increasing the chance of procedural success. We collected a case series of nine consecutive patients in which the Suoh 0.3 guidewire was able to gain the true lumen distally to a dissected segment.


Assuntos
Angioplastia Coronária com Balão/instrumentação , Cateterismo Cardíaco/instrumentação , Cateteres Cardíacos , Anomalias dos Vasos Coronários/terapia , Doenças Vasculares/congênito , Anomalias dos Vasos Coronários/diagnóstico por imagem , Desenho de Equipamento , Humanos , Stents , Resultado do Tratamento , Doenças Vasculares/diagnóstico por imagem , Doenças Vasculares/terapia
9.
Catheter Cardiovasc Interv ; 91(1): 57-63, 2018 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-28836346

RESUMO

Different strategies of retrograde approach were introduced in recent years to improve the success rate of percutaneous coronary intervention for coronary chronic total occlusions. The aim of this report is to describe a new technique, called "Trap and Occlude Technique," for retrograde wire externalization during CTO percutaneous revascularization. This technique may save time and reduce radiation exposure and procedure-related bleeding.


Assuntos
Angioplastia Coronária com Balão/métodos , Cateterismo Cardíaco/métodos , Oclusão Coronária/cirurgia , Idoso , Angioplastia Coronária com Balão/instrumentação , Cateterismo Cardíaco/instrumentação , Doença Crônica , Angiografia Coronária , Oclusão Coronária/diagnóstico por imagem , Oclusão Coronária/fisiopatologia , Stents Farmacológicos , Humanos , Masculino , Radiografia Intervencionista , Resultado do Tratamento
10.
Catheter Cardiovasc Interv ; 91(3): 470-474, 2018 02 15.
Artigo em Inglês | MEDLINE | ID: mdl-28988417

RESUMO

Coronary artery aneurysms (CAA) represent an uncommon disease with yet unclear standards of treatment. Clinical and anatomic characteristics determine choice of treatment. Stent-assisted coil embolization has been described as a valuable option for management of patients with wide-neck coronary aneurysms. Choice of appropriate stent sizing can be challenging particularly when there is a large difference between proximal and distal diameters. We report a case of stent-assisted coil embolization of a coronary aneurysm using a self-expandable stent. This type of stent can be helpful to treat CAA involving coronary sites where marked tapering of vessel diameter is often present.


Assuntos
Angioplastia Coronária com Balão/instrumentação , Aneurisma Coronário/terapia , Estenose Coronária/terapia , Embolização Terapêutica/instrumentação , Stents , Idoso , Angiografia por Tomografia Computadorizada , Aneurisma Coronário/diagnóstico por imagem , Angiografia Coronária/métodos , Estenose Coronária/diagnóstico por imagem , Humanos , Masculino , Desenho de Prótese , Resultado do Tratamento
11.
Catheter Cardiovasc Interv ; 89(2): E75-E83, 2017 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-27471134

RESUMO

Coronary perforation (CP) is a rare but potentially lethal complication of percutaneous coronary intervention (PCI). Management of CP is mainly conditioned by the extension of coronary rupture and location of the perforation. Successful treatment is highly affected by the operator's familiarity with tools and dedicated techniques to achieve prompt sealing of the disruption. We describe a "Balloon-Microcatheter" technique that may allow fast, safe, and effective management of CP with a single ≥ 6 Fr guiding catheter. © 2016 Wiley Periodicals, Inc.


Assuntos
Oclusão com Balão/instrumentação , Cateteres Cardíacos , Doença da Artéria Coronariana/terapia , Reestenose Coronária/terapia , Vasos Coronários/lesões , Intervenção Coronária Percutânea/efeitos adversos , Lesões do Sistema Vascular/terapia , Idoso , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Reestenose Coronária/diagnóstico por imagem , Reestenose Coronária/etiologia , Vasos Coronários/diagnóstico por imagem , Desenho de Equipamento , Humanos , Masculino , Miniaturização , Intervenção Coronária Percutânea/instrumentação , Stents , Resultado do Tratamento , Ultrassonografia de Intervenção , Lesões do Sistema Vascular/diagnóstico por imagem , Lesões do Sistema Vascular/etiologia
13.
EuroIntervention ; 20(3): e185-e197, 2024 Feb 05.
Artigo em Inglês | MEDLINE | ID: mdl-38343371

RESUMO

BACKGROUND: Percutaneous coronary interventions (PCI) of chronic total occlusions (CTO) have reached high procedural success rates thanks to dedicated equipment, evolving techniques, and worldwide adoption of state-of-the-art crossing algorithms. AIMS: We report the contemporary results of CTO PCIs performed by a large European community of experienced interventionalists. Furthermore, we investigated the impact of different risk factors for procedural major adverse cardiac and cerebrovascular events (MACCE) and trends of employment of specific devices like dual lumen microcatheters, guiding catheter extensions, intravascular ultrasound and calcium-modifying tools. METHODS: We evaluated data from 8,673 CTO PCIs included in the European Registry of Chronic Total Occlusion (ERCTO) between January 2021 and October 2022. RESULTS: The overall technical success rate was 89.1% and was higher in antegrade as compared with retrograde cases (92.8% vs 79.3%; p<0.001). Compared with antegrade procedures, retrograde procedures had a higher complexity of attempted lesions (Japanese CTO [J-CTO] score: 3.0±1.0 vs 1.9±1.2; p<0.001), a higher procedural and in-hospital MACCE rate (3.1% vs 1.2%; p<0.018) and a higher perforation rate with and without tamponade (1.5% vs 0.4% and 8.3% vs 2.1%, respectively; p<0.001). As compared with mid-volume operators, high-volume operators had a higher technical success rate in antegrade and retrograde procedures (93.4% vs 91.2% and 81.5% vs 69.0%, respectively; p<0.001), and had a lower MACCE rate (1.47% vs 2.41%; p<0.001) despite a higher mean complexity of the attempted lesions (J-CTO score: 2.42±1.28 vs 2.15±1.27; p<0.001). CONCLUSIONS: The adoption of different recanalisation techniques, operator experience and the use of specific devices have contributed to a high procedural success rate despite the high complexity of the lesions documented in the ERCTO.


Assuntos
Oclusão Coronária , Intervenção Coronária Percutânea , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Resultado do Tratamento , Oclusão Coronária/cirurgia , Oclusão Coronária/etiologia , Angiografia Coronária , Fatores de Risco , Europa (Continente) , Sistema de Registros , Doença Crônica
14.
Circ Cardiovasc Interv ; 16(8): e013009, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37458110

RESUMO

The outcomes of chronic total occlusion percutaneous coronary intervention have considerably improved during the last decade with continued emphasis on improving procedural safety. Vascular access site bleeding remains one of the most frequent complications. Several procedural strategies have been implemented to reduce the rate of vascular access site complications. This state-of-the-art review summarizes and describes the current evidence on optimal vascular access strategies for chronic total occlusion percutaneous coronary intervention.


Assuntos
Oclusão Coronária , Intervenção Coronária Percutânea , Doenças Vasculares , Humanos , Fatores de Risco , Resultado do Tratamento , Intervenção Coronária Percutânea/efeitos adversos , Hemorragia/etiologia , Oclusão Coronária/diagnóstico por imagem , Oclusão Coronária/terapia , Oclusão Coronária/complicações
15.
J Clin Med ; 11(23)2022 Nov 27.
Artigo em Inglês | MEDLINE | ID: mdl-36498587

RESUMO

Background: Simultaneous ulnar and radial artery compression (SURC) has emerged as a strategy to increase radial artery flow and mitigate radial artery occlusion (RAO) while achieving adequate hemostasis after transradial access (TRA), though its technical adoption has been limited worldwide. Methods: A systematic search of studies comparing SURC versus isolated radial artery compression after TRA for coronary angiography and/or intervention was performed. Data were pooled by meta-analysis using random-effects models. Odds ratios (OR) with relative 95% confidence intervals (CI) and standardized mean difference were used as measures of effect estimates. The primary endpoint was the occurrence of overall RAO. Results: A total of 6 studies and 6793 patients were included. SURC method as compared to isolated radial artery compression was associated with a lower risk of RAO both overall (OR 0.29; 95% CI, 0.13−0.61, p < 0.001; number needed to treat to benefit [NNTB] =38) and in-hospital (OR 0.28; 95% CI: 0.10 to 0.75; p = 0.01, NNTB = 36), with a reduced risk of unsuccessful patent hemostasis (OR: 0.13; 95% CI: 0.02 to 0.85; p = 0.03, NNT = 5) and upper extremity pain (OR: 0.48; 95% CI: 0.24 to 0.95; p = 0.04, NNTB = 124). No significant difference was observed in hemostasis time and in the risk of hematoma. Conclusion: Compared to isolated radial artery compression, SURC is associated with lower risk of RAO, unsuccessful patent hemostasis, and reported upper limb pain, without any trade-off in safety outcomes. With further development of dedicated dual compression devices, the proposed technique should be freed from usage constraints.

16.
JACC Cardiovasc Interv ; 15(12): 1191-1201, 2022 06 27.
Artigo em Inglês | MEDLINE | ID: mdl-35595673

RESUMO

BACKGROUND: Currently, transradial access (TRA) is the recommended access for coronary procedures because of increased safety, with radial artery occlusion (RAO) being its most frequent complication, which will increasingly affect patients undergoing multiple procedures during their lifetimes. Recently, distal radial access (DRA) has emerged as a promising alternative access to minimize RAO risk. A large-scale, international, randomized trial comparing RAO with TRA and DRA is lacking. OBJECTIVES: The aim of this study was to assess the superiority of DRA compared with conventional TRA with respect to forearm RAO. METHODS: DISCO RADIAL (Distal vs Conventional Radial Access) was an international, multicenter, randomized controlled trial in which patients with indications for percutaneous coronary procedure using a 6-F Slender sheath were randomized to DRA or TRA with systematic implementation of best practices to reduce RAO. The primary endpoint was the incidence of forearm RAO assessed by vascular ultrasound at discharge. Secondary endpoints include crossover, hemostasis time, and access site-related complications. RESULTS: Overall, 657 patients underwent TRA, and 650 patients underwent DRA. Forearm RAO did not differ between groups (0.91% vs 0.31%; P = 0.29). Patent hemostasis was achieved in 94.4% of TRA patients. Crossover rates were higher with DRA (3.5% vs 7.4%; P = 0.002), and median hemostasis time was shorter (180 vs 153 minutes; P < 0.001). Radial artery spasm occurred more with DRA (2.7% vs 5.4%; P = 0.015). Overall bleeding events and vascular complications did not differ between groups. CONCLUSIONS: With the implementation of a rigorous hemostasis protocol, DRA and TRA have equally low RAO rates. DRA is associated with a higher crossover rate but a shorter hemostasis time.


Assuntos
Arteriopatias Oclusivas , Cateterismo Periférico , Intervenção Coronária Percutânea , Cateterismo Periférico/efeitos adversos , Cateterismo Periférico/métodos , Angiografia Coronária/efeitos adversos , Angiografia Coronária/métodos , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/métodos , Artéria Radial/diagnóstico por imagem , Resultado do Tratamento
17.
EuroIntervention ; 17(12): e966-e970, 2021 Dec 17.
Artigo em Inglês | MEDLINE | ID: mdl-34338644

RESUMO

Dual lumen microcatheters (DLMC) have become indispensable tools in the setting of percutaneous coronary intervention (PCI) of chronic total occlusion (CTO). Other than allowing preservation and treatment of bifurcated coronary branches within or in the proximity of the CTO body, they enable the use of modified parallel wiring, antegrade dissection and re-entry, collateral selection and retrograde negotiation of the distal CTO cap. This EuroCTO consensus document describes current DLMC and suggests a practical guide to anatomies and techniques in which these devices are applicable.


Assuntos
Intervenção Coronária Percutânea , Humanos , Intervenção Coronária Percutânea/efeitos adversos
18.
G Ital Cardiol (Rome) ; 21(6 Suppl 1): 42S-45S, 2020 06.
Artigo em Italiano | MEDLINE | ID: mdl-32469344

RESUMO

Coronary perforation is a rare but potentially lethal complication of percutaneous coronary intervention and it is associated with an increased risk of adverse outcomes. There are no standardized techniques to achieve prompt and effective perforation sealing and treatment is left to the operator's preference and expertise. We report a case of successful embolization of a distal coronary artery perforation using the "block and deliver" technique. The technique is relatively simple and safe, it was effective, and we are strongly convinced that it may be helpful to all interventional cardiologists in their daily practice.


Assuntos
Vasos Coronários/lesões , Embolização Terapêutica/métodos , Traumatismos Cardíacos/terapia , Idoso , Traumatismos Cardíacos/etiologia , Traumatismos Cardíacos/patologia , Humanos , Masculino , Intervenção Coronária Percutânea/efeitos adversos , Resultado do Tratamento
19.
Heart ; 106(19): 1512-1518, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32817312

RESUMO

OBJECTIVE: Risk stratification is crucial to optimise treatment strategies in patients with COVID-19. We aimed to evaluate the impact on mortality of an early assessment of cardiac biomarkers in patients with COVID-19. METHODS: Humanitas Clinical and Research Hospital (Rozzano-Milan, Lombardy, Italy) is a tertiary centre that has been converted to the management of COVID-19. Patients with confirmed COVID-19 were entered in a dedicated database for cohort observational analyses. Outcomes were stratified according to elevated levels (ie, above the upper level of normal) of high-sensitivity cardiac troponin I (hs-TnI), B-type natriuretic peptide (BNP) or both measured within 24 hours after hospital admission. The primary outcome was all-cause mortality. RESULTS: A total of 397 consecutive patients with COVID-19 were included up to 1 April 2020. At the time of hospital admission, 208 patients (52.4%) had normal values for cardiac biomarkers, 90 (22.7%) had elevated both hs-TnI and BNP, 59 (14.9%) had elevated only BNP and 40 (10.1%) had elevated only hs-TnI. The rate of mortality was higher in patients with elevated hs-TnI (22.5%, OR 4.35, 95% CI 1.72 to 11.04), BNP (33.9%, OR 7.37, 95% CI 3.53 to 16.75) or both (55.6%, OR 18.75, 95% CI 9.32 to 37.71) as compared with those without elevated cardiac biomarkers (6.25%). A multivariate analysis identified concomitant elevation of both hs-TnI and BNP as a strong independent predictor of all-cause mortality (OR 3.24, 95% CI 1.06 to 9.93). CONCLUSIONS: An early detection of elevated hs-TnI and BNP predicts mortality in patients with COVID-19. Cardiac biomarkers should be systematically assessed in patients with COVID-19 at the time of hospital admission in order to optimise risk stratification.


Assuntos
Betacoronavirus , Doenças Cardiovasculares/epidemiologia , Infecções por Coronavirus/sangue , Infecções por Coronavirus/mortalidade , Peptídeo Natriurético Encefálico/sangue , Pneumonia Viral/sangue , Pneumonia Viral/mortalidade , Troponina I/sangue , Idoso , Idoso de 80 Anos ou mais , Biomarcadores/sangue , COVID-19 , Infecções por Coronavirus/complicações , Diagnóstico Precoce , Feminino , Hospitalização , Humanos , Itália , Masculino , Pessoa de Meia-Idade , Pandemias , Pneumonia Viral/complicações , Valor Preditivo dos Testes , Estudos Retrospectivos , Medição de Risco , SARS-CoV-2
20.
Cardiovasc Revasc Med ; 20(11S): 49-50, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31471271

RESUMO

Thrombus burden remains an important mortality risk factor during primary percutaneous coronary interventions (PCI), especially when associated with distal embolization of atheromatous debris (Sharma et al., 2016; Ibanez et al., 2018 [1,2]). Although routine thrombus aspiration during primary PCI in acute coronary syndrome (ACS) is not recommended (Sharma et al., 2016 [1]), some procedures become very challenging when thrombus removal and vessel reperfusion is not achieved with conventional dedicated devices. We describe a case of a 60-year old man with a late-comer infero-lateral ST-segment elevation myocardial infarction (STEMI) undergoing right coronary artery primary PCI. A high thrombotic burden was shown requiring an ultra-deep guide catheter intubation to perform a successful thromboaspiration and stenting.


Assuntos
Angioplastia Coronária com Balão/instrumentação , Cateterismo Cardíaco/instrumentação , Cateteres Cardíacos , Trombose Coronária/terapia , Infarto do Miocárdio com Supradesnível do Segmento ST/terapia , Trombectomia/instrumentação , Trombose Coronária/diagnóstico por imagem , Trombose Coronária/fisiopatologia , Stents Farmacológicos , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico por imagem , Infarto do Miocárdio com Supradesnível do Segmento ST/fisiopatologia , Sucção/instrumentação , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA