J Interv Card Electrophysiol ; 43(1): 65-75, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25779222

RESUMO

PURPOSE: Stress and anxiety are potential consequences from arrhythmias and implantable cardioverter defibrillator (ICD) shocks that can contribute to substantial morbidity. We assessed anxiety associated with an ICD and whether cognitive behavioral therapy (CBT) reduces anxiety. METHODS: The study consisted of two parts: part 1 (N = 690) was a prospective cross-sectional observational study of consecutive ICD patients. Patients completed the Beck Anxiety Inventory (BAI), Generalized Anxiety Disorder Scale (GAD-7), Florida Shock Anxiety Scale (FSAS), and Florida Patient Acceptance Survey (FPAS) psychometric tests. Part 2 (N = 29) was a pilot randomized controlled trial of CBT (three sessions in 3 months) vs. usual care (UC) in patients with BAI ≥ 19 from part 1. RESULTS: The median BAI and GAD-7 scores were 5 and 2, respectively. By BAI scores, 64.5 % had minimal and 3.9 % had severe anxiety. By GAD-7 scores, 73.0 % had low probability of anxiety and 2.9 % had high anxiety. Higher anxiety levels were associated with recent (p = 0.017) and total number of shocks (p = 0.002). Any shock was associated with fear about shocks (FSAS, p < 0.001) and reduced patient ICD acceptance (FPAS, p = 0.019). In the pilot trial of CBT, median BAI scores decreased from 24.5 to 11 at 1 year (p = 0.031) in the CBT group and GAD-7 scores from 12.5 to 7 (p = 0.063); no significant changes in anxiety scores were observed in the UC group. CONCLUSIONS: Severe anxiety was present in a small proportion of ICD patients, but higher anxiety was associated with recent and total number of shocks. The small pilot study suggested that a simple program of CBT might lower moderate-high anxiety with lasting effects to 1 year and supports the need for a larger trial to validate these results. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov identifier: NCT00851071. URL: http://clinicaltrials.gov/ct2/show/NCT00851071?term=anxiety+in+icd+patients+cleveland+clinic&rank=1.


Assuntos
Terapia Cognitivo-Comportamental/métodos , Desfibriladores Implantáveis/efeitos adversos , Desfibriladores Implantáveis/psicologia , Insuficiência Cardíaca/psicologia , Estresse Psicológico/etiologia , Estresse Psicológico/terapia , Feminino , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/prevenção & controle , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Estudos Prospectivos , Estresse Psicológico/psicologia , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA