Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 27
Filtrar
1.
J Esthet Restor Dent ; 36(2): 373-380, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37605963

RESUMO

OBJECTIVE: To investigate the effect of ceramic thickness and dental substrate (enamel vs. dentin/enamel) on the survival rate and failure load of non-retentive occlusal veneers. MATERIALS AND METHODS: Human maxillary molars (n = 60) were divided into five test-groups (n = 12). The groups (named DE-1.5, DE-1.0, DE-0.5, E-1.0, E-0.5) differed in their dental substrate (E = enamel, DE = dentin/enamel) and restoration thickness (standard: 1.5 mm, thin: 1.0 mm, ultrathin: 0.5 mm). All teeth were prepared for non-retentive monolithic lithium-disilicate occlusal veneers (IPS e.max Press, Ivoclar). Restorations were adhesively cemented (Syntac Classic/Variolink II, Ivoclar) and exposed to thermomechanical fatigue (1.2 million cycles, 1.6 Hz, 49 N/ 5-55°C). Single load to failure was performed using a universal testing-machine. A linear-regression model was applied, pairwise comparisons used the Student-Newman-Keuls method (p < 0.05). RESULTS: Three dentin-based occlusal veneers (one DE-1.0, two DE-0.5) revealed cracks after fatigue exposure, which corresponds to an overall-survival rate of 95%. Load to failure resulted in the following ranking: 2142 N(DE-0.5) > 2105 N(E-1.0) > 2075 N(E-0.5) > 1440 N(DE-1.5) > 1430 N(DE-1.0). Thin (E-1.0) and ultrathin enamel-based occlusal veneers (E-0.5) revealed high failure loads and surpassed the standard thickness dentin-based veneers (DE-1.5) significantly (p = 0.044, p = 0.022). CONCLUSION: All tested monolithic lithium disilicate occlusal veneers obtained failure loads above physiological chewing forces. Thin and ultrathin enamel-based occlusal veneers outperformed the standard thick dentin-based occlusal veneers. CLINICAL SIGNIFICANCE: Minimally invasive enamel-based occlusal veneer restorations with non-retentive preparation design may serve as a conservative treatment option.


Assuntos
Cerâmica , Porcelana Dentária , Humanos , Taxa de Sobrevida , Dente Molar , Teste de Materiais , Análise do Estresse Dentário , Facetas Dentárias , Falha de Restauração Dentária
2.
J Esthet Restor Dent ; 36(1): 47-55, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37772362

RESUMO

OBJECTIVE: To evaluate the effect of different hydrofluoric acid concentrations and etching times on the surface, chemical composition and microstructure of lithium disilicate. MATERIAL AND METHODS: Ninety specimens of pressed lithium disilicate (LDS) were obtained (IPS e.max Press, Rosetta SP and LiSi Press). The specimens of each material were divided in two groups according to the hydrofluoric acid concentration: 5% and 10% (n = 15/group), and subdivided according to the etching time: 20, 40 and 60 s (n = 5/group). Crystalline evaluations and chemical composition were performed through x-ray diffraction (XRD) and energy-dispersive x-ray spectroscopy (EDS), respectively. Microstructural analyses were performed by scanning electron microscope (SEM), surface roughness (Ra), and material thickness removal evaluation. Thickness removal and Ra data were analyzed by ANOVA and Tukey test (p < 0.05). RESULTS: XRD demonstrated characteristic peaks of lithium disilicate crystals, lithium phosphate and of a vitreous phase for all materials. EDS identified different compositions and SEM confirmed different surface responses to acid etching protocols. Material and etching time influenced Ra and material thickness removal (p < 0.05). CONCLUSION: Hydrofluoric acid concentration and etching time affect the surface characteristics of LDS differently. LiSi Press presented higher resistance to hydrofluoric acid etching compared to e.max Press and Rosetta SP. CLINICAL SIGNIFICANCE: Applying the appropriate etching protocol is pivotal to avoid excessive material removal and to prevent jeopardize the mechanical and optical properties of the material.


Assuntos
Colagem Dentária , Ácido Fluorídrico , Ácido Fluorídrico/química , Teste de Materiais , Porcelana Dentária/química , Cerâmica/química , Propriedades de Superfície , Colagem Dentária/métodos , Cimentos de Resina/química
3.
J Prosthet Dent ; 130(5): 739.e1-739.e8, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37684141

RESUMO

STATEMENT OF PROBLEM: The bonding of implant-supported prostheses is determined by abutment material, convergence angle, height, surface treatment, and luting agents. However, studies evaluating the bonding of luting agents to titanium base abutments with different heights under fatigue conditions are scarce. PURPOSE: The purpose of this in vitro study was to evaluate the retention of zirconia crowns bonded with different luting agents to titanium base abutments of different heights before and after fatigue testing. MATERIAL AND METHODS: Zirconia crowns were designed, milled, and distributed into 4 experimental groups according to the luting agents (G-Multi Primer/G-Cem LinkForce [MP/GC] and Scotchbond Universal/RelyX Ultimate [SU/RU]) and titanium base abutment heights (2.5 mm and 4 mm) (n=10). Pull-out testing was performed in a universal testing machine at a crosshead speed of 1 mm/min until crown displacement. Fatigue testing was performed by an electric precision fatigue simulator (1×106 cycles; 100 N; and 15 Hz), followed by pull-out testing of fatigued specimens. Collected data were statistically evaluated by using a linear mixed model after post hoc comparisons by the least significant difference test (α=.05). RESULTS: Luting agents, abutment heights, and fatigue influenced the bonding retention of zirconia crowns to titanium base abutments. SU/RU agents promoted higher pull-out compared with MP/GC for both abutment heights before and after fatigue. Higher abutment height increased pull-out regarding lower abutment height for SU/RU materials before and after fatigue testing. Although fatigue had no significant effect on the pull-out of MP/GC, lower bond retention was observed for SU/RU after fatigue, regardless of abutment height. CONCLUSIONS: Luting agent composition and the interaction with abutment height and fatigue influenced the retention of zirconia crowns to titanium base abutments.


Assuntos
Cimentos Dentários , Implantes Dentários , Cimentos Dentários/química , Titânio/química , Coroas , Zircônio/química , Teste de Materiais , Dente Suporte , Análise do Estresse Dentário
4.
Clin Oral Implants Res ; 33(1): 1-20, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34665900

RESUMO

OBJECTIVE: To analyze the clinical outcomes of all-ceramic single crowns (SCs) and fixed dental prostheses (FDPs) supported by ceramic implants. MATERIALS AND METHODS: Based on a focused question and customized PICO framework, electronic (Medline/EMBASE/Cochrane) and manual searches for studies reporting the clinical outcomes of all-ceramic SCs and FDPs supported by ceramic implants ≥12 months were performed. The primary outcomes were reconstruction survival and the chipping proportion. The secondary outcomes were implant survival, technical complications, and patient-related outcome measurements. Meta-analyses were performed after 1, 2, and 5 years using random-effect meta-analyses. RESULTS: Eight of the 1,403 initially screened titles and 55 full texts were included. Five reported on monolithic lithium disilicate (LS2) SCs, one on veneered zirconia SCs, and two on veneered zirconia SCs and FDPs, which reported all on cement-retained reconstructions (mean observation: 12.0-61.0 months). Meta-analyses estimated a 5-year survival rate of 94% (95% confidence interval [CI]: 82%-100%) for overall implant survival. Reconstruction survival proportions after 5 years were: monolithic LS2, 100% (95%CI: 95%-100%); veneered zirconia SCs, 89% (95%CI: 62%-100%); and veneered zirconia FDPs 94% (95%CI: 81%-100%). The chipping proportion after 5 years was: monolithic LS2, 2% (95%CI: 0%-11%); veneered zirconia SCs, 38% (95%CI: 24%-54%); and veneered zirconia FDPs, 57% (95%CI: 38%-76%). Further outcomes were summarized descriptively. CONCLUSIONS: Due to the limited data available, only tendencies could be identified. All-ceramic reconstructions supported by ceramic implants demonstrated promising survival rates after mid-term observation. However, high chipping proportions of veneered zirconia SCs and, particularly, FDPs diminished the overall outcome. Monolithic LS2 demonstrated fewer clinical complications. Monolithic reconstructions could be a valid treatment option for ceramic implants.


Assuntos
Implantes Dentários , Falha de Restauração Dentária , Cerâmica , Coroas , Porcelana Dentária , Planejamento de Prótese Dentária , Prótese Dentária Fixada por Implante , Humanos , Ligas Metalo-Cerâmicas , Zircônio
5.
Acta Neurochir (Wien) ; 164(5): 1347-1355, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-34668078

RESUMO

BACKGROUND: Neurosurgical approaches to the brain often require the mobilization of the temporal muscle. Many patients complain of postoperative pain, atrophy, reduced mouth opening, and masticatory problems. Although the pterional, frontolateral-extended-pterional, and temporal craniotomies are the most frequently used approaches in neurosurgery, a systematic assessment of the postoperative oral health-related quality of life has never been performed so far. This study evaluates the oral health-related quality of life of patients after pterional, frontolateral-extended-pterional, or temporal craniotomy using a validated and standardized dental questionnaire, compares the results with the normal values of the general population, and investigates whether this questionnaire is sensitive to changes caused by surgical manipulation of the temporal muscle. METHODS: The "Oral Health Impact Profile" (OHIP14) is a validated questionnaire to assess the oral health-related quality of life. It asks the patients to assess their oral health situation within the past 7 days in 14 questions. Possible answers range from 0 (never) to 4 (very often). Sixty patients with benign intracranial processes operated through a lateral cranial approach were included. The questionnaire was answered before surgery (baseline) and 3 months and 15 months after surgery. RESULTS: Overall, postoperative OHIP scores increase significantly after 3 months and decrease after 15 months, but not to preoperative values. No factors can be identified which show a considerable relationship with the postoperative OHIP score. CONCLUSIONS: Postoperative impairment of mouth opening and pain during mastication can be observed 3 to 15 months after surgery and sometimes cause feedback from patients and their dentists. However, in line with existing literature, these complaints decrease with time. The study shows that the OHIP questionnaire is sensitive to changes caused by surgical manipulation of the temporal muscle and can therefore be used to investigate the influence of surgical techniques on postoperative complaints. Postoperatively, patients show worse OHIP scores than the general population, demonstrating that neurosurgical cranial approaches negatively influence the patient's oral health-related wellbeing. Larger studies using the OHIP questionnaire should evaluate if postoperative physical therapy, speech therapy, or specialized rehabilitation devices can improve the masticatory impairment after craniotomy. TRIAL REGISTRATION: Clinical trial register: DRKS00011096.


Assuntos
Mastigação , Qualidade de Vida , Craniotomia/efeitos adversos , Craniotomia/métodos , Humanos , Saúde Bucal , Inquéritos e Questionários
6.
J Esthet Restor Dent ; 34(1): 145-153, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34989466

RESUMO

OBJECTIVE: To evaluate the effect of ceramic thicknesses, bonding surface (enamel vs. dentin), and preparation design (box vs. no box) on the fatigue survival and failure load of minimally invasive full-veneer restorations. MATERIALS AND METHODS: Human-premolars (n = 60) were divided into five test groups (n = 12). All teeth received full-veneer preparation with the following occlusal/labial thicknesses: standard: 1.5/0.8 mm; thin: 1.0/0.6 mm; ultrathin 0.5/0.4 mm. Preparations for each ceramic thickness were refined in enamel (E-1.0 and E-0.5) or dentin (D-1.5, D-1.0, and D-0.5). Control groups DB-1.5, EB-1.0, and EB-0.5 received box preparations. Monolithic lithium disilicate restorations (IPS-e.max-Press, Ivoclar Vivadent) were adhesively cemented (Syntac-Classic/Variolink-II, Ivoclar Vivadent) and subjected to cyclic mechanical loading (F = 49 N, 1.2 million cycles) with simultaneous thermocycling (5-55°C). All specimens were exposed to single load-to-failure. Pair-wise differences were calculated by using a linear regression model and Student-Newman-Keuls method (p < 0.05). RESULTS: All full-veneers of group D-1.5, E-1.0, E-0.5, DB-1.5, EB-1.0, and EB-0.5 survived fatigue. Two full-veneers (D-1.0 and D-0.5) revealed cracks during fatigue, resulting in an overall fatigue survival rate of 98.1%. Mean load-to-failure values (N) were as followed: 1005 (D-1.5); 866 (D-1.0); 816 (D-0.5); 1495 (E-1.0); 1279 (E-0.5); 1129 (DB-1.5); 1087 (EB-1.0); and 833 (EB-0.5). Irrespective of ceramic thicknesses, enamel-based full-veneers resulted in higher failure loads than dentin-based restorations. Box preparation reduced the failure loads of thin and ultrathin enamel-based restorations. CONCLUSION: All tested monolithic lithium disilicate full-veneer restorations exceeded physiological masticatory forces. Minimally invasive full-veneer restorations with enamel as a bonding surface and a non-retentive preparation design showed superior performance. CLINICAL SIGNIFICANCE: Enamel-based non-retentive full-veneers made of monolithic lithium disilicate may serve as a reliable and esthetical minimally invasive treatment option for premolars.


Assuntos
Porcelana Dentária , Facetas Dentárias , Cerâmica , Esmalte Dentário , Falha de Restauração Dentária , Análise do Estresse Dentário , Humanos , Teste de Materiais
7.
Clin Oral Implants Res ; 29 Suppl 16: 351-358, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30328181

RESUMO

OBJECTIVES: The aim of Working Group 4 was to address topics related to biologic risks and complications associated with implant dentistry. Focused questions on (a) diagnosis of peri-implantitis, (b) complications associated with implants in augmented sites, (c) outcomes following treatment of peri-implantitis, and (d) implant therapy in geriatric patients and/or patients with systemic diseases were addressed. MATERIALS AND METHODS: Four systematic reviews formed the basis for discussion in Group 4. Participants developed statements and recommendations determined by group consensus based on the findings of the systematic reviews. These were then presented and accepted following further discussion and modifications as required by the plenary. RESULTS: Bleeding on probing (BOP) alone is insufficient for the diagnosis of peri-implantitis. The positive predictive value of BOP alone for the diagnosis of peri-implantitis varies and is dependent on the prevalence of peri-implantitis within the population. For patients with implants in augmented sites, the prevalence of peri-implantitis and implant loss is low over the medium to long term. Peri-implantitis treatment protocols which include individualized supportive care result in high survival of implants after 5 years with about three-quarters of implants still present. Advanced age alone is not a contraindication for implant therapy. Implant placement in patients with cancer receiving high-dose antiresorptive therapy is contraindicated due to the associated high risk for complications. CONCLUSIONS: Diagnosis of peri-implantitis requires the presence of BOP as well as progressive bone loss. Prevalence of peri-implantitis for implants in augmented sites is low. Peri-implantitis treatment should be followed by individualized supportive care. Implant therapy for geriatric patients is not contraindicated; however, comorbidities and autonomy should be considered.


Assuntos
Implantes Dentários/efeitos adversos , Falha de Restauração Dentária , Odontologia , Peri-Implantite/etiologia , Assistência ao Convalescente , Aumento do Rebordo Alveolar , Conservadores da Densidade Óssea/efeitos adversos , Consenso , Bases de Dados Factuais , Implantação Dentária Endóssea , Suscetibilidade a Doenças , Humanos , Neoplasias/complicações , Peri-Implantite/diagnóstico , Peri-Implantite/epidemiologia , Índice Periodontal , Prevalência , Recidiva , Fatores de Risco
8.
Ceram Int ; 43(14): 10999-11005, 2017 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-29097830

RESUMO

The fabrication of zirconia dental restorations is a time-consuming process due to traditional slow sintering schemes; zirconia (Y-TZP) produced by these conventional routes are predominantly opaque. Novel speed sintering protocols have been developed to meet the demand for time and cost effective chairside CAD/CAM-produced restorations, as well as to control ceramic microstructures for better translucency. Although the speed sintering protocols have already been used to densify dental Y-TZP, the wear properties of these restorations remain elusive. Fast heating and cooling rates, as well as shorter sintering dwell times are known to affect the microstructure and properties of zirconia. Thus, we hypothesize that speed sintered zirconia dental restorations possess distinct wear and physical characteristics relative to their conventionally sintered counterparts. Glazed monolithic molar crowns of translucent Y-TZP (inCoris TZI, Sirona) were fabricated using three distinct sintering profiles: Super-speed (SS, 1580 °C, dwell time 10 min), Speed (S, 1510 °C, dwell time 25 min), and Long-term (LT, 1510 °C, dwell time 120 min). Microstructural, optical and wear properties were investigated. Crowns that were super-speed sintered possessed higher translucency. Areas of mild and severe wear were observed on the zirconia surface in all groups. Micropits in the wear crater were less frequent for the LT group. Groups S and SS exhibited more surface pits, which caused a scratched steatite surface that is associated with a greater volume loss. Tetragonal to monoclinic phase transformation, resulting from the sliding wear process, was present in all three groups. Although all test groups had withstood thermo-mechanical challenges, the presence of hairline cracks emanating from the occlusal wear facets and extending deep into the restoration indicates their susceptibility to fatigue sliding contact fracture.

11.
Eur Eat Disord Rev ; 24(4): 341-6, 2016 07.
Artigo em Inglês | MEDLINE | ID: mdl-27045791

RESUMO

BACKGROUND: There is hardly any empirical evidence on emotion processing by controlled studies in obesity. MATERIAL AND METHODS: Participants rated their emotions in response to visual emotional stimuli from the International Affective Picture System. Study 1 compared obese women with normal-weight controls and women with eating disorders. Study 2 compared obese men with normal-weight controls. RESULTS: Obese women had reduced emotional intensity scores for all basic emotions and the mixed emotion sadness-fear. Obese men had reduced scores for all emotions except happiness and disgust; anger showed a trend towards significance. The results were mainly based on ratings from non-depressed obese individuals. DISCUSSION: Obese men and women scored significantly lower on most basic and mixed emotions. Non-depressed obese subjects seem particularly affected. These new findings must be validated by further study, and longitudinal evaluation after weight loss, e.g. by bariatric surgery, will be of interest. Copyright © 2016 John Wiley & Sons, Ltd and Eating Disorders Association.


Assuntos
Sintomas Afetivos/psicologia , Emoções/fisiologia , Transtornos da Alimentação e da Ingestão de Alimentos/psicologia , Obesidade/psicologia , Adulto , Afeto , Sintomas Afetivos/complicações , Ira , Cirurgia Bariátrica , Estudos de Casos e Controles , Medo , Feminino , Felicidade , Humanos , Masculino , Percepção , Adulto Jovem
12.
J Neurosurg ; : 1-8, 2023 Nov 03.
Artigo em Inglês | MEDLINE | ID: mdl-37922564

RESUMO

OBJECTIVE: Many neurosurgical approaches require incision of the temporal muscle (TM). Consequently, patients often report reduced opening of the mouth, facial asymmetry, numbness, and pain after lateral craniotomies. A systematic assessment of these postoperative subjective complaints is lacking in the literature. Therefore, in this study, the authors evaluate subjective complaints after pterional, frontolateral-extended pterional, or temporal craniotomy using a 6-item questionnaire. They examine the association of these subjective complaints with the extent of the mobilization of the TM. METHODS: The questionnaire assessed complaints about limited opening of the mouth, pain in the mastication muscles, facial asymmetry, sensory deficits in the temporal region, weather sensitivity, and headache. Eligible patients with benign intracranial processes operated on using lateral cranial approaches between 2016 and 2019 were included. The questionnaire was answered before surgery (baseline) and 3 and 15 months after surgery. Surgeons documented the extent of TM incision. RESULTS: Among the 55 patients in this study, all complaints apart from headache showed an increase at a statistically significant rate at 3 months postoperatively, that is, limited mouth opening (p < 0.0001), pain in the mastication muscles (p < 0.0001), an impression of asymmetry in the mastication muscles (p = 0.0002), sensory disturbances in the temporal region (p < 0.0001), and weather sensitivity (p < 0.001). Only pain in the mastication muscles showed a relevant decrease at 15 months postsurgery (p = 0.058). The extent of the mobilized TM was associated with pain in the mastication muscles at 3 months (p = 0.0193). CONCLUSIONS: Subjective complaints in patients following lateral craniotomy can be detected. As the extent of the mobilized TM relevantly influenced pain in the mastication muscles, the authors conclude that one should sparsely mobilize the TM. Furthermore, a neurosurgeon should be aware and warn the patient of subjective postoperative complaints and inform the patient about their natural course.

13.
J Appl Oral Sci ; 31: e20220421, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36820784

RESUMO

The demands for dental materials continue to grow, driven by the desire to reach a better performance than currently achieved by the available materials. In the dental restorative ceramic field, the structures evolved from the metal-ceramic systems to highly translucent multilayered zirconia, aiming not only for tailored mechanical properties but also for the aesthetics to mimic natural teeth. Ceramics are widely used in prosthetic dentistry due to their attractive clinical properties, including high strength, biocompatibility, chemical stability, and a good combination of optical properties. Metal-ceramics type has always been the golden standard of dental reconstruction. However, this system lacks aesthetic aspects. For this reason, efforts are made to develop materials that met both the mechanical features necessary for the safe performance of the restoration as well as the aesthetic aspects, aiming for a beautiful smile. In this field, glass and high-strength core ceramics have been highly investigated for applications in dental restoration due to their excellent combination of mechanical properties and translucency. However, since these are recent materials when compared with the metal-ceramic system, many studies are still required to guarantee the quality and longevity of these systems. Therefore, a background on available dental materials properties is a starting point to provoke a discussion on the development of potential alternatives to rehabilitate lost hard and soft tissue structures with ceramic-based tooth and implant-supported reconstructions. This review aims to bring the most recent materials research of the two major categories of ceramic restorations: ceramic-metal system and all-ceramic restorations. The practical aspects are herein presented regarding the evolution and development of materials, technologies applications, strength, color, and aesthetics. A trend was observed to use high-strength core ceramics type due to their ability to be manufactured by CAD/CAM technology. In addition, the impacts of COVID-19 on the market of dental restorative ceramics are presented.


Assuntos
COVID-19 , Materiais Dentários , Humanos , Materiais Dentários/química , Cerâmica/química , Desenho Assistido por Computador , Porcelana Dentária , Zircônio/química , Teste de Materiais , Propriedades de Superfície
14.
Dent J (Basel) ; 11(9)2023 Aug 29.
Artigo em Inglês | MEDLINE | ID: mdl-37754327

RESUMO

To assess the reliability and failure modes of Ti-base abutments supported by narrow and wide-diameter implant systems. Narrow (Ø3.5 × 10 mm) and wide (Ø5 × 10 mm) implant systems of two different manufacturers with internal conical connections (16°) and their respective Ti-base abutments (3.5 and 4.5 mm) were evaluated. Ti-base abutments were torqued to the implants, standardized metallic maxillary incisor crowns were cemented, and step stress accelerated life testing of eighteen assemblies per group was performed in three loading profiles: mild, moderate, and aggressive until fracture or suspension. Reliability for missions of 100,000 cycles at 100 and 150 N was calculated, and fractographic analysis was performed. For missions at 100 N for 100,000 cycles, both narrow and wide implant systems exhibited a high probability of survival (≥99%, CI: 94-100%) without significant differences. At 150 N, wide-diameter implants presented higher reliability (≥99%, CI: 99-100%) compared to narrow implants (86%, CI: 61-95%), with no significant differences among manufacturers. Failure mode predominantly involved Ti-base abutment fractures at the abutment platform. Ti-base abutments supported by narrow and wide implant systems presented high reliability for physiologic masticatory forces, whereas for high load-bearing applications, wide-diameter implants presented increased reliability. Failures were confined to abutment fractures.

15.
Materials (Basel) ; 15(23)2022 Nov 28.
Artigo em Inglês | MEDLINE | ID: mdl-36499960

RESUMO

No evidence-based prosthetic treatment concept for 3-unit fixed-dental-prostheses (FDPs) on ceramic implants is currently available. Therefore, the aim of this in vitro study was to investigate the failure load and fatigue behavior of monolithic and bi-layer zirconia FDPs supported by one-piece ceramic implants. Eighty 3-unit FDPs supported by 160 zirconia-implants (ceramic.implant; vitaclinical) were divided into 4 groups (n = 20 each): Group Z-HT: 3Y-TZP monolithic-zirconia (Vita-YZ-HT); Group Z-ST: 4Y-TZP monolithic-zirconia (Vita-YZ-ST); Group FL: 3Y-TZP zirconia (Vita-YZ-HT) with facial-veneer (Vita-VM9); Group RL (Rapid-layer): PICN "table-top" (Vita-Enamic), 3Y-TZP-framework (Vita-YZ-HT). Half of the test samples (n = 10/group) were fatigued in a mouth-motion chewing-simulator (F = 98 N, 1.2 million-cycles) with simultaneous thermocycling (5−55 °C). All specimens (fatigued and non-fatigued) were afterwards exposed to single-load-to-failure-testing (Z010, Zwick). Statistical analysis was performed using ANOVA, Tukey's post-hoc tests and two-sample t-tests (p < 0.05, Bonferroni-corrected where appropriate). All specimens withstood fatigue application. While the effect of fatigue was not significant in any group (p = 0.714), the choice of material had a significant effect (p < 0.001). Material FL recorded the highest failure loads, followed by Z-ST, Z-HT and RL, both with and without fatigue application. Taken together, all tested FDP material combinations survived chewing forces that exceeded physiological levels. Bi-Layer FL and monolithic Z-ST showed the highest resilience and might serve as reliable prosthetic reconstruction concepts for 3-unit FDPs on ceramic implants.

16.
J Mech Behav Biomed Mater ; 135: 105451, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-36162164

RESUMO

To evaluate the effect of fatigue and aging on the crystalline content and reliability of a zirconia-toughened-alumina (ZTA) composite compared to its individual counterpart materials (3Y-TZP and Al2O3). Thirty-six disc-shaped specimens per group were obtained to comply with ISO 6872:2015. Crystalline content, microstructure and reliability of experimental groups were evaluated in four stages: 1) immediate; 2) aged; 3) fatigued; 4) aged + fatigue. Aging was performed in autoclave and Step-Stress-Accelerated-Life-Testing (SSALT) was performed using three stress profiles. Weibull statistics were used to determine Weibull parameters and life-expectancy. A significant increase in monoclinic phase in 3Y-TZP was observed after aging (19.31%), fatigue (17.88%) and aging + fatigue (55.81%), while ZTA evidenced minimal variation among all conditions (<5.69%). 3Y-TZP presented higher reliability than ZTA at 300 and 500 MPa, and ZTA outperformed Al2O3 at the same stress missions. None of the ceramics yielded acceptable reliability at 800 MPa. A higher characteristic strength was observed for 3Y-TZP, followed by ZTA and Al2O3. While after aging ZTA and Al2O3 remained stable, 3Y-TZP exhibited a significant increase in the characteristic stress. Aging did not affect the reliability of ZTA and Al2O3. 3Y-TZP demonstrated an increase in monoclinic content and characteristic strength after aging.


Assuntos
Óxido de Alumínio , Ítrio , Idoso , Óxido de Alumínio/química , Cerâmica/química , Materiais Dentários , Humanos , Teste de Materiais , Reprodutibilidade dos Testes , Propriedades de Superfície , Ítrio/química , Zircônio/química
17.
Materials (Basel) ; 14(8)2021 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-33921126

RESUMO

This laboratory study aimed to evaluate the thermo-mechanical fatigue behavior and failure modes of monolithic and rapid-layer posterior single-crowns (SCs) supported by zirconia implants. METHODS: 120 all-ceramic crowns supported by one-piece zirconia implants (ceramic.implant; vitaclinical) were divided into five groups (n = 24 each): Group Z-HT: 3Y-TZP monolithic-zirconia (Vita-YZ-HT); Group Z-ST: 4Y-TZP monolithic-zirconia (Vita-YZ-ST); Z-XT: 5Y-TZP monolithic-zirconia (Vita-YZ-XT); Group E: monolithic-polymer-infiltrated ceramic network (PICN,Vita-Enamic); Group RL (rapid layer): PICN-"table-top" (Vita-Enamic), 3Y-TZP-framework (Vita-YZ-HT). Half of the specimens of each group (n = 12) were exposed to fatigue with cyclic mechanical loading (F = 198N, 1.2-million cycles) and simultaneous thermocycling (5-55 °C). Single-load-to-failure testing (Z010, Zwick) was performed for all specimens without/with fatigue application. Data analysis was performed using ANOVA, Tukey's post-hoc test, two-sample t-test and Bonferroni correction (p < 0.05). RESULTS: All specimens survived fatigue exposure. Significant differences in failure loads were detected among groups (p ≤ 0.004). Materials Z-HT and Z-ST showed the highest failure loads followed by Z-XT, RL and E. The influence of fatigue was only significant for material RL. CONCLUSIONS: All types of tested materials exceeded clinically acceptable failure load values higher than 900N and can be recommended for clinical use. Z-HT and Z-ST appear to be highly reliable towards fatigue. Rapid-layer design of PICN and YZ-HT might be an interesting treatment concept for posterior implant SCs.

18.
J Adv Prosthodont ; 13(5): 269-280, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34777717

RESUMO

PURPOSE: The objective of this study was to evaluate the effect of thickness reduction and fatigue on the failure load of monolithic zirconia crowns. MATERIALS AND METHODS: 140 CAD-CAM fabricated crowns (3Y-TZP, inCorisTZI, Dentsply-Sirona) with different ceramic thicknesses (2.0, 1.5, 1.0, 0.8, 0.5 mm, respectively, named G2, G1.5, G1, G0.8, and G0.5) were investigated. Dies of a mandibular first molar were made of composite resin. The zirconia crowns were luted with a resin composite cement (RelyX Unicem 2 Automix, 3M ESPE). Half of the specimens (n = 14 per group) were mouth-motion-fatigued (1.2 million cycles, 1.6 Hz, 200 N/ 5 - 55℃, groups named G2-F, G1.5-F, G1-F, G0.8-F, and G0.5-F). Single-load to failure was performed using a universal testing-machine. Fracture modes were analyzed. Data were statistically analyzed using a Weibull 2-parameter distribution (90% CI) to determine the characteristic strength and Weibull modulus differences among the groups. RESULTS: Three crowns (21%) of G0.8 and five crowns (36%) of G0.5 showed cracks after fatigue. Characteristic strength was the highest for G2, followed by G1.5. Intermediate values were observed for G1 and G1-F, followed by significantly lower values for G0.8, G0.8-F, and G0.5, and the lowest for G0.5-F. Weibull modulus was the lowest for G0.8, intermediate for G0.8-F and G0.5, and significantly higher for the remaining groups. Fatigue only affected G0.5-F. CONCLUSION: Reduced crown thickness lead to reduced characteristic strength, even under failure loads that exceed physiological chewing forces. Fatigue significantly reduced the failure load of 0.5 mm monolithic 3Y-TZP crowns.

19.
Materials (Basel) ; 14(24)2021 Dec 08.
Artigo em Inglês | MEDLINE | ID: mdl-34947134

RESUMO

To evaluate the failure-load and survival-rate of screw-retained monolithic and bi-layered crowns bonded to titanium-bases before and after mouth-motion fatigue, 72 titanium-implants (SICvantage-max, SIC-invent-AG) were restored with three groups (n = 24) of screw-retained CAD/CAM implant-supported-single-crowns (ISSC) bonded to titanium-bases: porcelain-fused-to-metal (PFM-control), porcelain-fused-to-zirconia (PFZ-test) and monolithic LDS (LDS-test). Half of the specimens (n = 12/group) were subjected to fatigue in a chewing-simulator (1.2 million cycles, 198 N, 1.67 Hz, thermocycling 5-55 °C). All samples were exposed to single-load-to-failure without (PFM0, PFZ0, LDS0) or with fatigue (PFM1, PFZ1, LDS1). Comparisons were statistically analyzed with t-tests and regression-models and corrected for multiple-testing using the Student-Neuman-Keuls method. All PFM and LDS crowns survived fatigue exposure, whereas 16.7% of PFZ showed chipping failures. The mean failure-loads (±SD) were: PFM0: 2633 ± 389 N, PFM1: 2349 ± 578 N, PFZ0: 2152 ± 572 N, PFZ1: 1686 ± 691 N, LDS0: 2981 ± 798 N, LDS1: 2722 ± 497 N. Fatigue did not influence load to failure of any group. PFZ ISSC showed significantly lower failure-loads than monolithic-LDS regardless of artificial aging (p < 0.05). PFM ISSC showed significantly higher failure loads after fatigue than PFZ (p = 0.032). All ISSC failed in a range above physiological chewing forces. Premature chipping fractures might occur in PFZ ISSC. Monolithic-LDS ISSC showed high reliability as an all-ceramic material for screw-retained posterior hybrid-abutment-crowns.

20.
Int J Prosthodont ; 33(3): 272-276, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32320179

RESUMO

PURPOSE: To analyze the clinical behavior of screw-retained monolithic lithium disilicate (LDS) implant-supported single crowns (ISSCs) over a 1-year follow-up. MATERIALS AND METHODS: A total of 28 patients were restored with 45 screw-retained monolithic LDS (press-fabricated) ISSCs bonded to titanium bases in posterior sites. Modified United States Public Health Service criteria and Kaplan-Meier survival and success rates were evaluated. RESULTS: A total of 27 patients with 44 ISSCs were evaluated 12 months (mean ± standard deviation: 13.02 ± 2.28) after prosthesis delivery. No implant or crown failures occurred. The Kaplan-Meier survival and success rates were each 100% after 1 year. Minorly increased surface roughness was noted in the occlusal contact point areas of 9 ISSCs (20.5% Bravo rating). Marginal adaptation, color match, and anatomical form stayed favorable over time. CONCLUSION: Press-fabricated LDS monolithic screw-retained implant crowns appear to be a promising treatment option for posterior implants under short-term observation.


Assuntos
Desenho Assistido por Computador , Coroas , Parafusos Ósseos , Porcelana Dentária , Planejamento de Prótese Dentária , Prótese Dentária Fixada por Implante , Falha de Restauração Dentária , Humanos , Dados Preliminares , Estudos Prospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA