Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 121
Filtrar
1.
J Pediatr ; 272: 114122, 2024 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-38815742

RESUMO

OBJECTIVE: To test the hypothesis that neonates with symptomatic tetralogy of Fallot (TOF) and absent ductus arteriosus (ADA) have worse clinical outcomes compared with those with a ductus arteriosus (DA), and that this difference is driven by those born with ADA and with critically deficient pulmonary blood flow (CDPBF). STUDY DESIGN: We performed a retrospective, multicenter cohort study of neonates who underwent intervention for symptomatic TOF comparing death and reintervention between subjects with and without a DA identified on fetal echocardiogram or on echocardiogram performed in the first postnatal day. Exclusion criteria were as follows: inability to define DA status, collaterals supplying pulmonary blood flow, atrioventricular septal defect, and absent pulmonary valve. We defined CDPBF as undergoing a procedure to augment pulmonary blood flow on the date of birth or extracorporeal membrane oxygenation prior to such a procedure. RESULTS: The study cohort included 519 patients, among whom 11% had ADA. Patients with ADA were more likely to have a genetic syndrome and had smaller branch pulmonary artery size. In analyses adjusting for center, interventional treatment strategy, genetic syndrome, and minimum branch pulmonary artery size, ADA was associated with higher mortality risk (adjusted hazard ratio of 2.37 (95% CI: 1.07,5.27; P = .034). Seven patients had CDPBF (1.3% of the entire cohort and 12% of patients with ADA). CONCLUSIONS: A minority of symptomatic TOF neonates have ADA, which is associated with higher adjusted mortality risk compared with those with a DA. CDPBF appears to be a rare but important entity in this population.

2.
Pediatr Crit Care Med ; 24(3): 204-212, 2023 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-36729677

RESUMO

OBJECTIVES: Near-infrared spectroscopy (NIRS) has been increasingly accepted as a noninvasive marker of regional tissue oxygenation despite concerns of imprecision and wide limits of agreement (LOA) with invasive oximetry. New generation absolute monitors may have improved accuracy compared with trend monitors. We sought to compare the concordance with invasive venous oximetry of a new generation absolute NIRS-oximeter (FORESIGHT ELITE; CASMED, Branford, CT) with a modern widely used trend monitor (INVOS 5100C; Medtronic, Minneapolis, MN). DESIGN: Prospective single-center study. SETTING: Tertiary pediatric heart center. PATIENTS: Children undergoing elective cardiac catheterization under general anesthesia. Time-paired venous oximetry samples (jugular and renal) were compared with NIRS-derived oximetry by two monitors using regression and Bland-Altman analysis. INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: We enrolled 36 children (19 female, 10 cyanotic) with median age 4.1 years (25-75%, 2.5-7.8 yr) and weight 16.7 kg (12.3-29.1 kg). The absolute difference between NIRS-derived and invasive jugular oximetry was less than 10% in 67% of occasions for both monitors. Correlation was fair (Spearman rs = 0.40; p = 0.001) for the FORESIGHT ELITE and poor ( rs = 0.06; p = 0.71) for the INVOS 5100C. Bias and LOA were +6.7% (+22%, -9%) versus +1.3% (LOA = +24%, -21%), respectively. The absolute difference between NIRS-derived and invasive renal oximetry was less than 10% in 80% of occasions with moderate correlation ( rs = 0.57; p < 0.001) for the FORESIGHT ELITE and in 61% of occasions with moderate correlation ( rs = 0.58; p < 0.001) for the INVOS 5100C; bias and LOA were +3.6% (+19%, -12%) and -1.4 % (+27%, -30%), respectively. NIRS correlation with renal venous oximetry was worse for cyanotic versus noncyanotic patients ( p = 0.02). CONCLUSIONS: Concordance and LOA of NIRS-derived oximetry with invasive venous oximetry in the cerebral and renal vascular beds was suboptimal for clinical decision-making. Cyanosis adversely affected NIRS performance in the renal site.


Assuntos
Oximetria , Espectroscopia de Luz Próxima ao Infravermelho , Criança , Humanos , Feminino , Pré-Escolar , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Estudos Prospectivos , Oximetria/métodos , Oxigênio , Cateterismo Cardíaco , Cianose
3.
Pediatr Cardiol ; 44(1): 15-23, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36151322

RESUMO

Ebstein anomaly is the most common form of tricuspid valve congenital anomalies. The tricuspid valve is abnormal with different degrees of displacement of the septal leaflet and abnormal rotation of the valve towards the right ventricular outflow tract. In severe forms, it results in significant tricuspid regurgitation and requires surgical repair. There is an increased interest in understanding the anatomy of the tricuspid valve in this lesion as the surgical repair has evolved with the invention and wide adoption of the cone operation. Multimodality imaging plays an important role in diagnosis, follow-up, surgical planning and post-operative care. This review provides anatomical tips for the cardiac imagers caring for patients with Ebstein anomaly and will help provide image-based personalized medicine.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Anomalia de Ebstein , Insuficiência da Valva Tricúspide , Humanos , Anomalia de Ebstein/diagnóstico por imagem , Anomalia de Ebstein/cirurgia , Resultado do Tratamento , Valva Tricúspide/diagnóstico por imagem , Procedimentos Cirúrgicos Cardíacos/métodos
4.
Pediatr Cardiol ; 44(6): 1406-1413, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36995404

RESUMO

To evaluate short-term procedural outcomes and safety for infants < 2.5 kg who underwent catheterization with intended patent ductus arteriosus (PDA) device closure in a multi-center registry, as performance of this procedure becomes widespread. A multi-center retrospective review was performed using data from the Congenital Cardiac Catheterization Project on Outcomes (C3PO) registry. Data were collected for all intended cases of PDA closure in infants < 2.5 kg from April 2019 to December 2020 at 13 participating sites. Successful device closure was defined as device placement at the conclusion of the catheterization. Procedural outcomes and adverse events (AE) were described, and associations between patient characteristics, procedural outcomes and AEs were analyzed. During the study period, 300 cases were performed with a median weight of 1.0 kg (range 0.7-2.4). Successful device closure was achieved in 98.7% of cases with a 1.7% incidence of level 4/5 AEs, including one periprocedural mortality. Neither failed device placement nor adverse events were significantly associated with patient age, weight or institutional volume. Higher incidence of adverse events associated with patients who had non-cardiac problems (p = 0.017) and cases with multiple devices attempted (p = 0.064). Transcatheter PDA closure in small infants can be performed with excellent short-term outcomes and safety across institutions with variable case volume.


Assuntos
Permeabilidade do Canal Arterial , Dispositivo para Oclusão Septal , Lactente , Humanos , Permeabilidade do Canal Arterial/cirurgia , Resultado do Tratamento , Cateterismo Cardíaco/métodos , Sistema de Registros , Fatores de Tempo , Estudos Retrospectivos
5.
Pediatr Cardiol ; 44(8): 1691-1701, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37382636

RESUMO

The Pediatric Heart Network's Fontan Udenafil Exercise Longitudinal (FUEL) Trial (Mezzion Pharma Co. Ltd., NCT02741115) demonstrated improvements in some measures of exercise capacity and in the myocardial performance index following 6 months of treatment with udenafil (87.5 mg twice daily). In this post hoc analysis, we evaluate whether subgroups within the population experienced a differential effect on exercise performance in response to treatment. The effect of udenafil on exercise was evaluated within subgroups defined by baseline characteristics, including peak oxygen consumption (VO2), serum brain-type natriuretic peptide level, weight, race, gender, and ventricular morphology. Differences among subgroups were evaluated using ANCOVA modeling with fixed factors for treatment arm and subgroup and the interaction between treatment arm and subgroup. Within-subgroup analyses demonstrated trends toward quantitative improvements in peak VO2, work rate at the ventilatory anaerobic threshold (VAT), VO2 at VAT, and ventilatory efficiency (VE/VCO2) for those randomized to udenafil compared to placebo in nearly all subgroups. There was no identified differential response to udenafil based on baseline peak VO2, baseline BNP level, weight, race and ethnicity, gender, or ventricular morphology, although participants in the lowest tertile of baseline peak VO2 trended toward larger improvements. The absence of a differential response across subgroups in response to treatment with udenafil suggests that the treatment benefit may not be restricted to specific sub-populations. Further work is warranted to confirm the potential benefit of udenafil and to evaluate the long-term tolerability and safety of treatment and to determine the impact of udenafil on the development of other morbidities related to the Fontan circulation.Trial Registration NCT0274115.


Assuntos
Consumo de Oxigênio , Sulfonamidas , Humanos , Criança , Sulfonamidas/uso terapêutico , Exercício Físico , Pirimidinas/uso terapêutico , Teste de Esforço , Tolerância ao Exercício
6.
Cardiol Young ; : 1-8, 2023 Nov 30.
Artigo em Inglês | MEDLINE | ID: mdl-38031461

RESUMO

BACKGROUND: Neurocognitive impairment and quality of life are two important long-term challenges for patients with complex CHD. The impact of re-interventions during adolescence and young adulthood on neurocognition and quality of life is not well understood. METHODS: In this prospective longitudinal multi-institutional study, patients 13-30 years old with severe CHD referred for surgical or transcatheter pulmonary valve replacement were enrolled. Clinical characteristics were collected, and executive function and quality of life were assessed prior to the planned pulmonary re-intervention. These results were compared to normative data and were compared between treatment strategies. RESULTS: Among 68 patients enrolled from 2016 to 2020, a nearly equal proportion were referred for surgical and transcatheter pulmonary valve replacement (53% versus 47%). Tetralogy of Fallot was the most common diagnosis (59%) and pulmonary re-intervention indications included stenosis (25%), insufficiency (40%), and mixed disease (35%). There were no substantial differences between patients referred for surgical and transcatheter therapy. Executive functioning deficits were evident in 19-31% of patients and quality of life was universally lower compared to normative sample data. However, measures of executive function and quality of life did not differ between the surgical and transcatheter patients. CONCLUSION: In this patient group, impairments in neurocognitive function and quality of life are common and can be significant. Given similar baseline characteristics, comparing changes in neurocognitive outcomes and quality of life after surgical versus transcatheter pulmonary valve replacement will offer unique insights into how treatment approaches impact these important long-term patient outcomes.

7.
J Pediatr ; 250: 22-28.e4, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35772511

RESUMO

OBJECTIVE: To evaluate early growth following primary or staged repair of neonatal symptomatic tetralogy of Fallot (sTOF). STUDY DESIGN: We performed a retrospective, multicenter cohort study of consecutive infants with sTOF who underwent initial intervention at age ≤30 days, from 2005 to 2017. Management strategies were either primary repair or staged repair (ie, initial palliation followed by complete repair). The primary outcome was change in weight-for-age z-score (ΔWAZ) from the initial intervention to age 6 ± 2 months. Secondary outcomes included method and mode of feeding, feeding-related medications, and feeding-related readmissions. Propensity score adjustment was used to account for baseline differences between groups. A secondary analysis was performed comparing patients stratified by the presence of adequate growth (6-month ΔWAZ > -0.5) or inadequate growth (6-month ΔWAZ ≤ -0.5), independent of treatment strategy. RESULTS: The study cohort included 143 primary repair subjects and 240 staged repair subjects. Prematurity was more common in the staged repair group. After adjustment, median ΔWAZ did not differ between treatment groups over the first 6 months of life (primary: -0.43 [IQR, -1.17 to 0.50]; staged: -0.31 [IQR, -1.31 to 0.71]; P = .55). For the entire cohort, ΔWAZ was negative (-0.36; IQR, -1.21 to 0.63). There were no between-group differences in the secondary outcomes. Secondary analysis revealed that the subjects with adequate growth were more likely to be orally fed at initial hospital discharge (P = .04). CONCLUSIONS: In neonates with sTOF, growth trajectory over the first 6 months of life was substandard, irrespective of treatment strategy. Those patients with adequate growth were more likely to be discharged from the index procedure on oral feeds.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Tetralogia de Fallot , Humanos , Lactente , Recém-Nascido , Tetralogia de Fallot/cirurgia , Estudos Retrospectivos , Estudos de Coortes , Resultado do Tratamento , Procedimentos Cirúrgicos Cardíacos/métodos
8.
Catheter Cardiovasc Interv ; 100(4): 596-605, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35904221

RESUMO

BACKGROUND: Morbidity with surgical systemic-to-pulmonary artery shunting (SPS) in infants ≤2.5 kg has remained high. Patent ductus arteriosus (PDA) stenting may be a valid alternative. The objective of this study is to evaluate outcomes following PDA stenting in patients ≤2.5 kg from four large tertiary centers. METHODS: Retrospective review of all neonates ≤2.5 kg with duct-dependent pulmonary circulation who underwent PDA stenting. Procedural details, pulmonary arterial growth, reinterventions, surgery type, and outcomes were assessed. RESULTS: PDA stents were implanted in 37 of 38 patients attempted (18 female) at a median procedural weight of 2.2 kg (interquartile range [IQR], 2-2.4 kg). Seven patients (18%) had a genetic abnormality and 16 (42%) had associated comorbidities. The median intensive care unit stay was 4 days (IQR, 2-6.75 days), and the median hospital stay was 20 days (IQR, 16-57.25). One patient required a rescue shunt procedure, with three others requiring early SPS (<30 days postprocedure). Twenty patients (54%) required reintervention with either balloon angioplasty, restenting, or both. At 6-month follow-up, right pulmonary artery growth (median z-score -1.16 to 0.01, p = 0.05) was greater than the left pulmonary artery (median z-score -0.9 to -0.64, p = 0.35). Serious adverse effects (SAEs) were seen in 18% (N = 7) of our cohort. One patient developed an SAE during planned reintervention There were no intraprocedural deaths, with one early procedure-related mortality, and three interstage mortalities not directly related to PDA stenting. CONCLUSIONS: PDA stenting in infants ≤2.5 kg is feasible and effective, promoting pulmonary artery growth. Reintervention rates are relatively high, though many are planned to allow for optimal growth before a definitive operation.


Assuntos
Permeabilidade do Canal Arterial , Canal Arterial , Cateterismo Cardíaco/efeitos adversos , Permeabilidade do Canal Arterial/complicações , Permeabilidade do Canal Arterial/diagnóstico por imagem , Permeabilidade do Canal Arterial/terapia , Feminino , Humanos , Lactente , Recém-Nascido , Circulação Pulmonar , Estudos Retrospectivos , Stents , Resultado do Tratamento
9.
Pediatr Cardiol ; 43(1): 121-131, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34524483

RESUMO

Patent ductus arteriosus (PDA) stenting is an accepted method for securing pulmonary blood flow in cyanotic neonates. In neonates with pulmonary atresia and single source ductal-dependent pulmonary blood flow (SSPBF), PDA stenting remains controversial. We sought to evaluate outcomes in neonates with SSPBF, comparing PDA stenting and surgical Blalock-Taussig shunt (BTS). Neonates with SSPBF who underwent PDA stenting or BTS at the four centers of the Congenital Catheterization Research Collaborative from January 2008 to December 2015 were retrospectively reviewed. Reintervention on the BTS or PDA stent prior to planned surgical repair served as the primary endpoint. Additional analyses of peri-procedural complications, interventions, and pulmonary artery growth were performed. A propensity score was utilized to adjust for differences in factors. Thirty-five patients with PDA stents and 156 patients with BTS were included. The cohorts had similar baseline characteristics, procedural complications, and mortality. Interstage reintervention rates were higher in the PDA stent cohort (48.6% vs. 15.4%, p < 0.001).


Assuntos
Procedimento de Blalock-Taussig , Permeabilidade do Canal Arterial , Canal Arterial , Cateterismo Cardíaco , Canal Arterial/cirurgia , Permeabilidade do Canal Arterial/cirurgia , Humanos , Recém-Nascido , Artéria Pulmonar/cirurgia , Circulação Pulmonar , Estudos Retrospectivos , Stents , Resultado do Tratamento
10.
Pediatr Cardiol ; 43(7): 1587-1598, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35381860

RESUMO

Neonates with symptomatic tetralogy of Fallot (sTOF) may undergo palliations with varying physiology, namely systemic to pulmonary artery connections (SPC) or right ventricular outflow tract interventions (RVOTI). A comparison of palliative strategies based on the physiology created is lacking. Consecutive sTOF neonates undergoing SPC or RVOTI from 2005-2017 were reviewed from the Congenital Cardiac Research Collaborative. The primary outcome was survival with successful complete repair (CR) by 18 months. A variety of secondary outcomes were assessed including overall survival, hospitalization-related comorbidities, and interstage reinterventions. Propensity score adjustment was utilized to compare treatment strategies. The cohort included 252 SPC (surgical shunt = 226, ductus arteriosus stent = 26) and 68 RVOTI (balloon pulmonary valvuloplasty = 48, RVOT stent = 11, RVOT patch = 9) patients. Genetic syndrome (29 [42.6%] v 75 [29.8%], p = 0.04), weight < 2.5 kg (28 [41.2%] v 68 [27.0%], p = 0.023), bilateral pulmonary artery Z-score < - 2 (19 [28.0%] v 36 [14.3%], p = 0.008), and pre-intervention antegrade flow (48 [70.6%] v 104 [41.3%], p < 0.001) were more common in RVOTI. Significant center differences were noted (p < 0.001). Adjusted survival to CR by 18 months (HR = 0.87, 95% CI = 0.63-1.21, p = 0.41) and overall survival (HR = 2.08, 95% CI = 0.93-4.65, p = 0.074) were similar. RVOTI had increased interstage reintervention (HR = 2.15, 95% CI = 1.36-3.99, p = 0.001). Total anesthesia (243 [213, 277] v 328 [308, 351] minutes, p < 0.001) and cardiopulmonary bypass times (117 [103, 132] v 151 [143, 160] minutes, p < 0.001) favored RVOTI. In this multicenter comparison of physiologic palliation strategies for sTOF, survival to successful CR and overall survival were similar; however, reintervention burden was significantly higher in RVOTI.


Assuntos
Procedimento de Blalock-Taussig , Tetralogia de Fallot , Humanos , Lactente , Recém-Nascido , Cuidados Paliativos , Artéria Pulmonar/cirurgia , Estudos Retrospectivos , Resultado do Tratamento
11.
Circulation ; 141(8): 641-651, 2020 02 25.
Artigo em Inglês | MEDLINE | ID: mdl-31736357

RESUMO

BACKGROUND: The Fontan operation creates a total cavopulmonary connection, a circulation in which the importance of pulmonary vascular resistance is magnified. Over time, this circulation leads to deterioration of cardiovascular efficiency associated with a decline in exercise performance. Rigorous clinical trials aimed at improving physiology and guiding pharmacotherapy are lacking. METHODS: The FUEL trial (Fontan Udenafil Exercise Longitudinal) was a phase III clinical trial conducted at 30 centers. Participants were randomly assigned udenafil, 87.5 mg twice daily, or placebo in a 1:1 ratio. The primary outcome was the between-group difference in change in oxygen consumption at peak exercise. Secondary outcomes included between-group differences in changes in submaximal exercise at the ventilatory anaerobic threshold, the myocardial performance index, the natural log of the reactive hyperemia index, and serum brain-type natriuretic peptide. RESULTS: Between 2017 and 2019, 30 clinical sites in North America and the Republic of Korea randomly assigned 400 participants with Fontan physiology. The mean age at randomization was 15.5±2 years; 60% of participants were male, and 81% were white. All 400 participants were included in the primary analysis with imputation of the 26-week end point for 21 participants with missing data (11 randomly assigned to udenafil and 10 to placebo). Among randomly assigned participants, peak oxygen consumption increased by 44±245 mL/min (2.8%) in the udenafil group and declined by 3.7±228 mL/min (-0.2%) in the placebo group (P=0.071). Analysis at ventilatory anaerobic threshold demonstrated improvements in the udenafil group versus the placebo group in oxygen consumption (+33±185 [3.2%] versus -9±193 [-0.9%] mL/min, P=0.012), ventilatory equivalents of carbon dioxide (-0.8 versus -0.06, P=0.014), and work rate (+3.8 versus +0.34 W, P=0.021). There was no difference in change of myocardial performance index, the natural log of the reactive hyperemia index, or serum brain-type natriuretic peptide level. CONCLUSIONS: In the FUEL trial, treatment with udenafil (87.5 mg twice daily) was not associated with an improvement in oxygen consumption at peak exercise but was associated with improvements in multiple measures of exercise performance at the ventilatory anaerobic threshold. CLINICAL TRIAL REGISTRATION: URL: https://www.clinicaltrials.gov. Unique identifier: NCT02741115.


Assuntos
Cardiopatias/tratamento farmacológico , Inibidores da Fosfodiesterase 5/uso terapêutico , Pirimidinas/uso terapêutico , Sulfonamidas/uso terapêutico , Adolescente , Criança , Método Duplo-Cego , Esquema de Medicação , Exercício Físico , Feminino , Técnica de Fontan , Cardiopatias/congênito , Cardiopatias/cirurgia , Frequência Cardíaca , Humanos , Masculino , Peptídeo Natriurético Encefálico/sangue , Consumo de Oxigênio , Inibidores da Fosfodiesterase 5/efeitos adversos , Efeito Placebo , Pirimidinas/efeitos adversos , Sulfonamidas/efeitos adversos , Trombose/diagnóstico , Trombose/etiologia , Resultado do Tratamento
12.
Pediatr Cardiol ; 42(3): 533-542, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33394118

RESUMO

Isolated pulmonary artery (PA) of ductal origin (IPADO) is a rare cardiac defect which requires surgical repair, with or without preceding palliation. We sought to determine the impact of treatment strategy on outcomes. Retrospective study of consecutive patients with IPADO that underwent staged or primary repair from 1/05 to 9/16 at 6 Congenital Cardiac Research Collaborative centers. Patients with single ventricle physiology, major aortopulmonary collaterals, or bilateral IPADO were excluded. Primary outcome was isolated PA z-score at late follow-up. Secondary outcomes included PA symmetry index (isolated:confluent PA diameter) and reintervention burden. Propensity score adjustment was used to account for baseline differences. Of 60 patients in the study cohort, 26 (43%) underwent staged and 34 (57%) primary repair. The staged and primary repair groups differed in weight at diagnosis and presence of other heart disease but not in baseline PA dimensions. Staged patients underwent ductal stent (n = 16) or surgical shunt (n = 10) placement followed by repair at 210 vs. 21 days in the primary repair group (p < 0.001). At median follow-up of 4.5 years post-repair, after adjustment, isolated PA z-score (- 0.74 [- 1.75, - 0.26] vs. - 1.95 [- 2.91, - 1.59], p = 0.012) and PA symmetry index (0.81 [0.49, 1.0] vs. 0.55 [0.48, 0.69], p = 0.042) significantly favored the staged repair group. Freedom from PA reintervention was not different between groups (adjusted HR 0.78 [0.41, 1.48]; p = 0.445). A staged approach to repair of IPADO is associated with superior isolated PA size and symmetry at late follow-up. Consideration should be given to initial palliation in IPADO patients, when feasible.


Assuntos
Procedimentos Cirúrgicos Cardíacos/métodos , Cardiopatias Congênitas/cirurgia , Artéria Pulmonar/anormalidades , Artéria Pulmonar/cirurgia , Cateterismo Cardíaco/métodos , Permeabilidade do Canal Arterial/cirurgia , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Cuidados Paliativos/métodos , Reoperação/métodos , Estudos Retrospectivos , Stents , Resultado do Tratamento
13.
Cardiol Young ; 31(11): 1829-1834, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-33726868

RESUMO

BACKGROUND: Multicentre research databases can provide insights into healthcare processes to improve outcomes and make practice recommendations for novel approaches. Effective audits can establish a framework for reporting research efforts, ensuring accurate reporting, and spearheading quality improvement. Although a variety of data auditing models and standards exist, barriers to effective auditing including costs, regulatory requirements, travel, and design complexity must be considered. MATERIALS AND METHODS: The Congenital Cardiac Research Collaborative conducted a virtual data training initiative and remote source data verification audit on a retrospective multicentre dataset. CCRC investigators across nine institutions were trained to extract and enter data into a robust dataset on patients with tetralogy of Fallot who required neonatal intervention. Centres provided de-identified source files for a randomised 10% patient sample audit. Key auditing variables, discrepancy types, and severity levels were analysed across two study groups, primary repair and staged repair. RESULTS: Of the total 572 study patients, data from 58 patients (31 staged repairs and 27 primary repairs) were source data verified. Amongst the 1790 variables audited, 45 discrepancies were discovered, resulting in an overall accuracy rate of 97.5%. High accuracy rates were consistent across all CCRC institutions ranging from 94.6% to 99.4% and were reported for both minor (1.5%) and major discrepancies type classifications (1.1%). CONCLUSION: Findings indicate that implementing a virtual multicentre training initiative and remote source data verification audit can identify data quality concerns and produce a reliable, high-quality dataset. Remote auditing capacity is especially important during the current COVID-19 pandemic.


Assuntos
COVID-19 , Confiabilidade dos Dados , Humanos , Recém-Nascido , Pandemias , Estudos Retrospectivos , SARS-CoV-2
14.
Catheter Cardiovasc Interv ; 95(7): 1285-1295, 2020 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-31943749

RESUMO

OBJECTIVE: Assess clinical performance of a new device for transcatheter closure of atrial septal defect (ASD). BACKGROUND: Previously-approved ASD Closure devices have known limitations. Device erosion has been associated with the AMPLATZER® septal occluder in patients with retro-aortic rim deficiency (<5 mm), while defects ≥18 mm are too large for the GORE® CARDIOFORM septal occluder. The GORE® CARDIOFORM ASD occluder (GCA), a hybrid of the approved devices, was designed to expand the eligible ASD population. METHODS: One-hundred and twenty-five ASD patients were enrolled in a prospective, multicenter registry. Descriptive clinical endpoints included: technical implant success, closure success, serious adverse events (SAE), clinically significant new arrhythmia, and wire frame fracture. Procedural outcomes and adverse events were adjudicated by an Echocardiography Core Lab and Independent Data Review Board, respectively. RESULTS: Median subject age was 12.3 years (range 2.9-84.7), with 72% of patients ≤18 years old. Median ASD stop-flow diameter was 17.0 mm (8.0-30.0), with 43% ≥18 mm. Deficient retro-aortic rim occurred in 57% of subjects, and 30% had both diameter ≥ 18 mm and deficient rim. Technical Implant Success was achieved in 120/125 (96%), though three devices were removed within 24 hr. At the scheduled 6-month evaluation, 112/117 returned for evaluation. All 112 had closure success. SAE occurred in 6/125 (4.8%) and 6/125 (4.8%) had clinically significant new arrhythmia. Wire frame fractures occurred in 37/104 (36%), without any associated clinical sequelae, residual shunt, or device instability. CONCLUSION: The GCA performed effectively and safely in this initial cohort, and led to FDA approval based on this data.


Assuntos
Cateterismo Cardíaco/instrumentação , Comunicação Interatrial/terapia , Dispositivo para Oclusão Septal , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Cateterismo Cardíaco/efeitos adversos , Criança , Pré-Escolar , Feminino , Comunicação Interatrial/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Desenho de Prótese , Sistema de Registros , Fatores de Tempo , Resultado do Tratamento , Estados Unidos , Adulto Jovem
15.
Catheter Cardiovasc Interv ; 95(4): 726-733, 2020 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-31815357

RESUMO

BACKGROUND: Carotid artery (CA) and axillary artery (AA) access are increasingly used for transcatheter stenting of the patent ductus arteriosus (PDA), although reports are limited. METHODS: The Congenital Catheterization Research Collaborative (CCRC) reviewed multicenter data from infants who underwent PDA stenting via the CA or AA approach from 2008 to 2017, and compared outcomes to those of infants undergoing PDA stenting via the femoral artery (FA) approach. Post-procedure ultrasound (US) imaging was reviewed. RESULTS: Forty-nine infants underwent PDA stenting from the CA (n = 43) or AA (n = 6) approach, compared with 55 infants who underwent PDA stenting from the FA approach. The PDA was the sole pulmonary blood flow (PBF) source in 61% of infants in the CA/AA cohort, compared with 33% of the FA cohort (p < .01). Ductal tortuosity for CA/AA cohort was Type I (straight) in 10 (20%), Type II (one turn) in 17 (35%), and Type III (multiple turns) in 22 (45%) infants and reflected a greater degree of tortuosity when compared to the FA cohort (p < .01). In 17 infants with CA/AA approach, the "flip technique" was used, and was associated with shorter procedure times for highly tortuous PDA (Type III) patients. Rates of procedural complications were similar across access sites. Most common complications were access site injury (thrombus or bleeding) and stent malposition. No complications were specifically related to the "flip technique." CONCLUSIONS: Use of CA and AA approach for PDA stenting was found to be more commonly employed in sole source PBF and highly tortuous PDAs. Procedural modifications such as the "flip technique" may lead to shorter procedure times. CA and AA approaches are associated with a similar burden of procedural or late complications. Post-procedural surveillance of the CA and AA is suggested, given the incidence of vascular findings on US.


Assuntos
Artéria Axilar , Cateterismo Cardíaco/instrumentação , Artérias Carótidas , Cateterismo Periférico , Permeabilidade do Canal Arterial/terapia , Artéria Femoral , Cuidados Paliativos , Circulação Pulmonar , Stents , Artéria Axilar/diagnóstico por imagem , Cateterismo Cardíaco/efeitos adversos , Artérias Carótidas/diagnóstico por imagem , Cateterismo Periférico/efeitos adversos , Permeabilidade do Canal Arterial/diagnóstico por imagem , Permeabilidade do Canal Arterial/fisiopatologia , Feminino , Artéria Femoral/diagnóstico por imagem , Humanos , Recém-Nascido , Masculino , Punções , Estudos Retrospectivos , Resultado do Tratamento , Ultrassonografia de Intervenção , Estados Unidos
16.
Catheter Cardiovasc Interv ; 96(1): 145-155, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32061033

RESUMO

Evidence-based recommendations for clinical practice are intended to help health care providers and patients make decisions, minimize inappropriate practice variation, promote effective resource use, improve clinical outcomes, and direct future research. The Society for Cardiovascular Angiography and Interventions (SCAI) has been engaged in the creation and dissemination of clinical guidance documents since the 1990s. These documents are a cornerstone of the society's education, advocacy, and quality improvement initiatives. The publications committee is charged with oversight of SCAI's clinical documents program and has created this manual of standard operating procedures to ensure consistency, methodological rigor, and transparency in the development and endorsement of the society's documents. The manual is intended for use by the publications committee, document writing groups, external collaborators, SCAI representatives, peer reviewers, and anyone seeking information about the SCAI documents program.


Assuntos
Comitês Consultivos/normas , Angiografia/normas , Cateterismo Cardíaco/normas , Procedimentos Endovasculares/normas , Manuais como Assunto/normas , Intervenção Coronária Percutânea/normas , Guias de Prática Clínica como Assunto/normas , Sociedades Médicas/normas , Medicina Baseada em Evidências/normas , Humanos , Redação/normas
17.
Cardiol Young ; 30(7): 995-1000, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32500847

RESUMO

Being overweight is associated with reduced functional capacity in Fontan patients. Increased adiposity leads to accumulation of epicardial and intra-abdominal visceral fat, which produce proinflammatory cytokines and may affect endothelial function. This retrospective study to evaluate the association between visceral fat and Fontan haemodynamics included 23 Fontan patients >18 years old with MRI and catheterization data available. Epicardial fat volume indexed to body surface area was measured by cardiac MRI, and intra-abdominal visceral fat thickness and subcutaneous fat thickness were derived from abdominal MRI. Stepwise regression models were used to determine univariable and multivariable associations between fat measures and haemodynamics. Mean age was 28.2 ± 9.5 years and body mass index was 26 ± 4 kg/m2. Mean central venous pressure was 13 ± 3 mmHg and pulmonary vascular resistance index was 1.23WU·m2 (interquartile range: 0.95-1.56). Epicardial fat volume was associated with age (r2 = 0.37, p = 0.002), weight (r2 = 0.26, p = 0.013), body mass index (r2 = 0.27, p = 0.011), and intra-abdominal visceral fat (r2 = 0.30, p = 0.018). Subcutaneous fat thickness did not relate to these measures. There was modest correlation between epicardial fat volume and pulmonary vascular resistance (r2 = 0.27, p = 0.02) and a trend towards significant correlation between intra-abdominal fat thickness and pulmonary vascular resistance (r2 = 0.21, p = 0.06). Subcutaneous fat thickness was not associated with Fontan haemodynamics. In multivariable analysis, including age and visceral fat measures, epicardial fat was independently correlated with pulmonary vascular resistance (point estimate 0.13 ± 0.05 per 10 ml/m2 increase, p = 0.03). In conclusion, in adults with Fontan circulation, increased visceral fat is associated with higher pulmonary vascular resistance. Excess visceral fat may represent a therapeutic target to improve Fontan haemodynamics.


Assuntos
Técnica de Fontan , Gordura Intra-Abdominal , Adiposidade , Adolescente , Adulto , Índice de Massa Corporal , Hemodinâmica , Humanos , Gordura Intra-Abdominal/diagnóstico por imagem , Estudos Retrospectivos , Adulto Jovem
18.
Cardiol Young ; 30(12): 1923-1929, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33050969

RESUMO

OBJECTIVE: Operators are mindful of the balloon-to-aortic annulus ratio when performing balloon aortic valvuloplasty. The method of measurement of the aortic valve annulus has not been standardised. METHODS AND RESULTS: Patients who underwent aortic valvuloplasty at two paediatric centres between 2007 and 2014 were included. The valve annulus measured by echocardiography and angiography was used to calculate the balloon-to-aortic annulus ratio and measurements were compared. The primary endpoint was an increase in aortic insufficiency by ≥2 degrees. Ninety-eight patients with a median age at valvuloplasty of 2.1 months (Interquartile range (IQR): 0.2-105.5) were included. The angiographic-based annulus was 8.2 mm (IQR: 6.8-16.0), which was greater than echocardiogram-based annulus of 7.5 mm (IQR: 6.1-14.8) (p < 0.001). This corresponded to a significantly lower angiographic balloon-to-aortic annulus ratio of 0.9 (IQR: 0.9-1.0), compared to an echocardiographic ratio of 1.1 (IQR: 1.0-1.1) (p < 0.001). The degree of discrepancy in measured diameter increased with smaller valve diameters (p = 0.041) and in neonates (p = 0.044). There was significant disagreement between angiographic and echocardiographic balloon-to-aortic annulus ratio measures regarding "High" ratio of >1.2, with angiographic ratio flagging only 2/12 (16.7%) of patients flagged by echocardiographic ratio as "High" (p = 0.012). Patients who had an increase in the degree of aortic insufficiency post valvuloplasty, only 3 (5.5%) had angiographic ratio > 1.1, while 21 (38%) had echocardiographic ratio >1.1 (p < 0.001). Patients with resultant ≥ moderate insufficiency more often had an echocardiographic ratio of >1.1 than angiographic ratio of >1.1 There was no association between increase in balloon-to-aortic annulus ratio and gradient reduction. CONCLUSIONS: Angiographic measurement is associated with a greater measured aortic valve annulus and the development of aortic insufficiency. Operators should use caution when relying solely on angiographic measurement when performing balloon aortic valvuloplasty.


Assuntos
Estenose da Valva Aórtica , Valvuloplastia com Balão , Angiografia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Criança , Ecocardiografia , Humanos , Lactente , Recém-Nascido , Estudos Retrospectivos , Resultado do Tratamento
19.
Cardiol Young ; 30(8): 1070-1075, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32635947

RESUMO

The Fontan Outcomes Network was created to improve outcomes for children and adults with single ventricle CHD living with Fontan circulation. The network mission is to optimise longevity and quality of life by improving physical health, neurodevelopmental outcomes, resilience, and emotional health for these individuals and their families. This manuscript describes the systematic design of this new learning health network, including the initial steps in development of a national, lifespan registry, and pilot testing of data collection forms at 10 congenital heart centres.


Assuntos
Técnica de Fontan , Cardiopatias Congênitas , Adulto , Criança , Cardiopatias Congênitas/epidemiologia , Cardiopatias Congênitas/cirurgia , Humanos , Longevidade , Qualidade de Vida , Sistema de Registros , Estados Unidos/epidemiologia
20.
Circulation ; 137(6): 589-601, 2018 02 06.
Artigo em Inglês | MEDLINE | ID: mdl-29042354

RESUMO

BACKGROUND: Infants with ductal-dependent pulmonary blood flow may undergo palliation with either a patent ductus arteriosus (PDA) stent or a modified Blalock-Taussig (BT) shunt. A balanced multicenter comparison of these 2 approaches is lacking. METHODS: Infants with ductal-dependent pulmonary blood flow palliated with either a PDA stent or a BT shunt from January 2008 to November 2015 were reviewed from the 4 member centers of the Congenital Catheterization Research Collaborative. Outcomes were compared by use of propensity score adjustment to account for baseline differences between groups. RESULTS: One hundred six patients with a PDA stent and 251 patients with a BT shunt were included. The groups differed in underlying anatomy (expected 2-ventricle circulation in 60% of PDA stents versus 45% of BT shunts; P=0.001) and presence of antegrade pulmonary blood flow (61% of PDA stents versus 38% of BT shunts; P<0.001). After propensity score adjustment, there was no difference in the hazard of the primary composite outcome of death or unplanned reintervention to treat cyanosis (hazard ratio, 0.8; 95% confidence interval [CI], 0.52-1.23; P=0.31). Other reinterventions were more common in the PDA stent group (hazard ratio, 29.8; 95% CI, 9.8-91.1; P<0.001). However, the PDA stent group had a lower adjusted intensive care unit length of stay (5.3 days [95% CI, 4.2-6.7] versus 9.19 days [95% CI, 7.9-10.6]; P<0.001), a lower risk of diuretic use at discharge (odds ratio, 0.4; 95% CI, 0.25-0.64; P<0.001) and procedural complications (odds ratio, 0.4; 95% CI, 0.2-0.77; P=0.006), and larger (152 mm2/m2 [95% CI, 132-176] versus 125 mm2/m2 [95% CI, 113-138]; P=0.029) and more symmetrical (symmetry index, 0.84 [95% CI, 0.8-0.89] versus 0.77 [95% CI, 0.75-0.8]; P=0.008] pulmonary arteries at the time of subsequent surgical repair or last follow-up. CONCLUSIONS: In this multicenter comparison of palliative PDA stent and BT shunt for infants with ductal-dependent pulmonary blood flow adjusted for differences in patient factors, there was no difference in the primary end point, death or unplanned reintervention to treat cyanosis. However, other markers of morbidity and pulmonary artery size favored the PDA stent group, supporting PDA stent as a reasonable alternative to BT shunt in select patients.


Assuntos
Procedimento de Blalock-Taussig , Cateterismo Cardíaco/instrumentação , Permeabilidade do Canal Arterial/cirurgia , Cuidados Paliativos/métodos , Circulação Pulmonar , Stents , Procedimento de Blalock-Taussig/efeitos adversos , Procedimento de Blalock-Taussig/mortalidade , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/mortalidade , Permeabilidade do Canal Arterial/diagnóstico por imagem , Permeabilidade do Canal Arterial/mortalidade , Permeabilidade do Canal Arterial/fisiopatologia , Feminino , Mortalidade Hospitalar , Humanos , Lactente , Mortalidade Infantil , Recém-Nascido , Masculino , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Estados Unidos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA