Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 128
Filtrar
1.
Osteoporos Int ; 29(9): 2161, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-29987344

RESUMO

This article was originally published under a CC BY-NC-ND 4.0 license, but has now been made available under a CC BY 4.0 license. The PDF and HTML versions of the paper have been modified accordingly.

2.
Osteoporos Int ; 28(3): 1121-1131, 2017 03.
Artigo em Inglês | MEDLINE | ID: mdl-27921145

RESUMO

Loading increases bone mass and strength in a site-specific manner; however, possible effects of loading on bone matrix composition have not been evaluated. Site-specific structural and material properties of mouse bone were analyzed on the macro- and micro/molecular scale in the presence and absence of axial loading. The response of bone to load is heterogeneous, adapting at molecular, micro-, and macro-levels. INTRODUCTION: Osteoporosis is a degenerative disease resulting in reduced bone mineral density, structure, and strength. The overall aim was to explore the hypothesis that changes in loading environment result in site-specific adaptations at molecular/micro- and macro-scale in mouse bone. METHODS: Right tibiae of adult mice were subjected to well-defined cyclic axial loading for 2 weeks; left tibiae were used as physiologically loaded controls. The bones were analyzed with µCT (structure), reference point indentation (material properties), Raman spectroscopy (chemical), and small-angle X-ray scattering (mineral crystallization and structure). RESULTS: The cranial and caudal sites of tibiae are structurally and biochemically different within control bones. In response to loading, cranial and caudal sites increase in cortical thickness with reduced mineralization (-14 and -3%, p < 0.01, respectively) and crystallinity (-1.4 and -0.3%, p < 0.05, respectively). Along the length of the loaded bones, collagen content becomes more heterogeneous on the caudal site and the mineral/collagen increases distally at both sites. CONCLUSION: Bone structure and composition are heterogeneous, finely tuned, adaptive, and site-specifically responsive at the micro-scale to maintain optimal function. Manipulation of this heterogeneity may affect bone strength, relative to specific applied loads.


Assuntos
Adaptação Fisiológica/fisiologia , Tíbia/fisiologia , Suporte de Carga/fisiologia , Animais , Calcificação Fisiológica/fisiologia , Colágeno/análise , Força Compressiva/fisiologia , Feminino , Camundongos Endogâmicos C57BL , Análise Espectral Raman/métodos , Tíbia/química , Tíbia/diagnóstico por imagem , Microtomografia por Raio-X/métodos
3.
Eur Cell Mater ; 31: 250-63, 2016 Apr 13.
Artigo em Inglês | MEDLINE | ID: mdl-27071735

RESUMO

We explored the osseointegration potential of two macroporous titanium surfaces obtained using fast plasma sintering (FPS): Ti macroporous structures with 400-600 µmØ pores (TiMac400) and 850-1000 µmØ pores (TiMac850). They were compared against two surfaces currently in clinical use: Ti-Growth® and air plasma spray (Ti-Y367). Each surface was tested, once placed over a Ti-alloy and once onto a CoCr bulk substrate. Implants were placed in medial femoral condyles in 24 sheep. Samples were explanted at four and eight weeks after surgery. Push-out loads were measured using a material-testing system. Bone contact and ingrowth were assessed by histomorphometry and SEM and EDX analyses. Histology showed early osseointegration for all the surfaces tested. At 8 weeks, TiMac400, TiMac850 and Ti-Growth® showed deep bone ingrowth and extended colonisation with newly formed bone. The mechanical push-out force was equal in all tested surfaces. Plasma spray surfaces showed greater bone-implant contact and higher level of pores colonisation with new bone than FPS produced surfaces. However, the void pore area in FPS specimens was significantly higher, yet the FPS porous surfaces allowed a deeper osseointegration of bone to implant. FPS manufactured specimens showed similar osseointegration potential to the plasma spray surfaces for orthopaedic implants. FPS is a useful technology for manufacturing macroporous titanium surfaces. Furthermore, its capability to combine two implantable materials, using bulk CoCr with macroporous titanium surfaces, could be of interest as it enables designers to conceive and manufacture innovative components. FPS delivers functional graded materials components with macroporous structures optimised for osseointegration.


Assuntos
Materiais Biocompatíveis/farmacologia , Desenvolvimento Ósseo/efeitos dos fármacos , Materiais Revestidos Biocompatíveis/farmacologia , Teste de Materiais/métodos , Osseointegração/fisiologia , Próteses e Implantes , Titânio/farmacologia , Animais , Microscopia Eletrônica de Varredura , Osseointegração/efeitos dos fármacos , Porosidade , Ovinos , Espectrometria por Raios X , Propriedades de Superfície , Titânio/metabolismo
4.
Scand J Med Sci Sports ; 26(6): 684-93, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26058332

RESUMO

Advancing age is a well-known risk factor for tendon disease. Energy-storing tendons [e.g., human Achilles, equine superficial digital flexor tendon (SDFT)] are particularly vulnerable and it is thought that injury occurs following an accumulation of micro-damage in the extracellular matrix (ECM). Several authors suggest that age-related micro-damage accumulates due to a failure of the aging cell population to maintain the ECM or an imbalance between anabolic and catabolic pathways. We hypothesized that ageing results in a decreased ability of tendon cells to synthesize matrix components and matrix-degrading enzymes, resulting in a reduced turnover of the ECM and a decreased ability to repair micro-damage. The SDFT was collected from horses aged 3-30 years with no signs of tendon injury. Cell synthetic and degradative ability was assessed at the mRNA and protein levels. Telomere length was measured as an additional marker of cell ageing. There was no decrease in cellularity or relative telomere length with increasing age, and no decline in mRNA or protein levels for matrix proteins or degradative enzymes. The results suggest that the mechanism for age-related tendon deterioration is not due to reduced cellularity or a loss of synthetic functionality and that alternative mechanisms should be considered.


Assuntos
Envelhecimento/metabolismo , Matriz Extracelular/fisiologia , Metaloproteinases da Matriz/metabolismo , Fragmentos de Peptídeos/biossíntese , Pró-Colágeno/biossíntese , Tendões/citologia , Tendões/metabolismo , Proteína ADAM12/genética , Proteína ADAM17/genética , Proteínas ADAMTS/genética , Envelhecimento/patologia , Animais , DNA/metabolismo , Cavalos , Metaloproteinases da Matriz/genética , RNA Mensageiro/metabolismo , Encurtamento do Telômero , Tendões/enzimologia , Inibidor Tecidual de Metaloproteinase-3/genética , Inibidores Teciduais de Metaloproteinases/genética , Inibidor Tecidual 4 de Metaloproteinase
5.
Eur Cell Mater ; 27: 332-49, 2014 Jun 08.
Artigo em Inglês | MEDLINE | ID: mdl-24908426

RESUMO

Open fractures are at risk of serious infection and, if infected, require several surgical interventions and courses of systemic antibiotics. We investigated a new injectable formulation that simultaneously hardens in vivo to form a porous scaffold for bone repair and delivers antibiotics at high concentrations to the local site of infection. Duration of antimicrobial activity against Staphylococcus aureus was determined using the serial plate transfer test. Ultimate compressive strength and porosity of the material was measured with and without antibiotics. The material was evaluated in vivo in an ovine medial femoral condyle defect model contaminated with S. aureus. Sheep were sacrificed at either 2 or 13 weeks and the defect and surrounding bone assessed using micro-computed tomography and histology. Antimicrobial activity in vitro persisted for 19-21 days. Sheep with antibiotic-free material and bacteria became infected, while those with antibiotic-containing material and bacteria did not. Similarly, new bone growth was seen in uninoculated animals with plain polymer, and in those with antibiotic polymer with bacteria, but not in sheep with plain polymer and bacteria. The antibiotic-impregnated scaffolds were effective in preventing S. aureus infections whilst supporting bone growth and repair. If translated into clinical practice, this approach might reduce the need for systemic antibiotics.


Assuntos
Anti-Infecciosos/farmacologia , Regeneração Óssea , Clindamicina/farmacologia , Gentamicinas/farmacologia , Osteomielite/prevenção & controle , Infecções Estafilocócicas/prevenção & controle , Alicerces Teciduais/química , Animais , Anti-Infecciosos/uso terapêutico , Plásticos Biodegradáveis/farmacologia , Clindamicina/uso terapêutico , Fêmur/microbiologia , Fêmur/cirurgia , Gentamicinas/uso terapêutico , Regeneração Tecidual Guiada/métodos , Ácido Láctico/farmacologia , Osteomielite/tratamento farmacológico , Ácido Poliglicólico/farmacologia , Copolímero de Ácido Poliláctico e Ácido Poliglicólico , Ovinos , Infecções Estafilocócicas/tratamento farmacológico , Staphylococcus aureus/efeitos dos fármacos , Staphylococcus aureus/patogenicidade
6.
Equine Vet J ; 43(3): 288-94, 2011 May.
Artigo em Inglês | MEDLINE | ID: mdl-21492205

RESUMO

REASONS FOR PERFORMING STUDY: Mesenchymal stem cell (MSC) therapy for orthopaedic disease is being used with increasing frequency; there is a need to define a safe, reliable and effective technique for the recovery of MSCs from the sternum of the horse. OBJECTIVES: To describe an optimised safe technique for obtaining bone marrow-derived MSCs from the sternum of the Thoroughbred horse. METHODS: The anatomical relationship of the sternum with the heart and internal anatomy was demonstrated in cadavers. Sternal anatomy was evaluated ultrasonographically and after midline sectioning. Sternebrae were examined histologically after aspiration to determine the effect of needle insertion. The quality of the aspirate was evaluated as the number of colony-forming units from sequential and separately aspirated 5 ml aliquots and assessed for their multipotency using trilineage differentiation. RESULTS: The optimal safe location for the needle was the 5th sternebra because it had a safe dorsoventral thickness and was cranial to the apex of the heart. This sternebra could be reliably identified ultrasonographically. Aspirates could also be obtained from the 4th and 6th sternebrae, although the former is between the front limbs and the latter closer to the heart. Minimal disruption of the internal bony architecture was seen after needle insertion through the thin outer cortex and the first 5 ml aliquot contained the greatest number of colony-forming units of mesenchymal stem cells with trilineage capabilities. CONCLUSIONS: Accurate placement of a Jamshidi needle into the medullary cavity of the 4th-6th individual sternebrae is facilitated by the use of ultrasonography and enables aspiration of bone marrow reliably with minimal damage to the sternum and risk to the horse. POTENTIAL CLINICAL RELEVANCE: Sternal marrow aspiration as described is a safe and reliable technique to obtain MSCs for orthopaedic cell-based therapies.


Assuntos
Biópsia por Agulha/veterinária , Células da Medula Óssea/fisiologia , Cavalos/fisiologia , Células-Tronco Mesenquimais/fisiologia , Esterno/fisiologia , Animais , Feminino , Masculino
7.
Vet Clin North Am Equine Pract ; 27(2): 315-33, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-21872761

RESUMO

Tendon and ligament injuries have proved difficult to treat effectively. Cell-based therapies offer the potential to harness the complex protein synthetic machinery of the cell to induce a regenerative response rather than fibrous scarring. This article reviews the current state of play with respect to the clinically used cell preparations for the treatment of tendon and ligaments overstrain injuries.


Assuntos
Transplante de Células/veterinária , Doenças dos Cavalos/terapia , Ligamentos/lesões , Traumatismos dos Tendões/veterinária , Animais , Transplante de Células/métodos , Cavalos , Traumatismos dos Tendões/terapia
8.
Proc Inst Mech Eng H ; 224(10): 1221-32, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21138240

RESUMO

The degree of osseomechanical integration of dental implants is acutely sensitive to their mechanical environment. Bone, both as a tissue and structure, adapts its mass and architecture in response to loading conditions. Therefore, application of predefined controlled loads may be considered as a treatment option to promote early maturation of bone/implant interface prior to or in conjunction with crown/prosthesis attachment. Although many studies have established that the magnitude, rate of the applied strain, and frequency have significant effects on the osteogenic response, the actual specific relationships between strain parameters and frequency have not yet been fully defined. The purpose of this study was to develop a stimulator to apply defined mechanical stimuli to individual dental implants in vivo immediately after implantation, exploring the hypothesis that immediate controlled loading could enhance implant integration. An electromechanical device was developed, based on load values obtained using a two-dimensional finite element analysis of the bone/implant interface generating 1000 to 4000 pe and operated at 30 and 3 Hz respectively. The device was then tested in a cadaveric pig mandible, and periosteal bone surface strains were recorded for potential future comparison with a three-dimensional finite element model to determine loading regimens to optimize interface strains and iterate the device for clinical use.


Assuntos
Implantes Dentários , Osseointegração , Animais , Fenômenos Biomecânicos , Restauração Dentária Permanente , Análise de Elementos Finitos , Estimulação Física/instrumentação , Estresse Mecânico , Suínos
9.
Br Poult Sci ; 51(1): 22-30, 2010 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-20390566

RESUMO

1. The relationship between the physical activity and leg health of broiler chickens was assessed on a semi-commercial scale. 2. Three batches of birds (2128 per batch) were raised under two lighting regimes during the photoperiod; either a step-wise change of light intensity alternating between an illuminance of 200 and 10 lx or a constant illuminance of 10 lx. The activity of focal individuals (24 per batch) was observed at 2, 4 and 6 weeks of age, and leg health assessed weekly, based on gait score, the prevalence of burns on the hock and foot pad, and angulation and rotation of the leg at the intertarsal joint. Cortical bone density and thickness and area moments of inertia of the mid-physis tibiotarsus were measured post mortem at 6 weeks of age. 3. The step-wise change in light intensity did not affect overall performance, activity or leg health. 4. An individual bird's activity did not affect its gait score, the prevalence of hock burn or foot pad burn, cortical density or thickness or shape of the tibiotarsus. Sex of the bird was the only factor to affect significantly the area moment of inertia in the horizontal and vertical planes of the tibiotarsus, with females showing a lower moment of inertia for both. No variable had a significant effect on cortical density or thickness. Mean cortical density was low across all birds and may indicate that, when allowed to move freely as much or as little as they choose, broiler chickens do not exercise enough or do not perform the higher impact activities required to affect bone quality. 5. These findings imply that the activity of broiler chickens raised on a semi-commercial scale is unaffected by step-wise changes in light intensity and that other husbandry measures are needed to raise activity and hence improve leg health.


Assuntos
Criação de Animais Domésticos/métodos , Bem-Estar do Animal , Osso e Ossos/fisiologia , Galinhas/crescimento & desenvolvimento , Condicionamento Físico Animal/fisiologia , Animais , Galinhas/fisiologia , Feminino , Masculino
10.
J Appl Physiol (1985) ; 104(2): 416-22, 2008 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-18079264

RESUMO

Tendons can be considered in two functional groups, those contributing to energetics of locomotion and those acting solely to position the limb. The energy-storing tendons in both human and equine athletes have a high frequency of injury with similar pathophysiology. In previous studies, high-intensity exercise appears to induce a disruption of the matrix rather than functional adaptation in adults. Here we explore the hypothesis that the introduction of controlled exercise during growth would result in an adaptive response without deleterious effects. Young horses were given a controlled exercise program similar to that previously shown to induce matrix changes in energy-storing tendons of skeletally mature animals. The tendons were assessed in relation to mechanical properties, molecular composition, and morphology. Results showed a significant increase in cartilage oligomeric matrix protein (COMP) in the positional tendon but not in the energy-storing tendon. Other matrix properties and mechanical properties were not significantly changed. While the imposition of high-strain-rate exercise in immature horses failed to augment the development of the energy-storing tendon over and above that induced by normal pasture exercise, it did not induce deleterious changes, supporting an earlier introduction of athletic training in horses.


Assuntos
Envelhecimento/fisiologia , Condicionamento Físico Animal , Esforço Físico , Tendões/crescimento & desenvolvimento , Adaptação Fisiológica , Fatores Etários , Animais , Fenômenos Biomecânicos , Proteína de Matriz Oligomérica de Cartilagem , Colágeno/análise , Proteínas da Matriz Extracelular/análise , Feminino , Glicoproteínas/análise , Glicosaminoglicanos/análise , Cavalos , Masculino , Proteínas Matrilinas , Tendões/química , Tendões/ultraestrutura
11.
Equine Vet J ; 40(2): 141-6, 2008 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-18093891

RESUMO

REASON FOR PERFORMING STUDY: The injury-prone, energy-storing equine superficial digital flexor tendon (SDFT) of the mature performance horse has a limited ability to respond to exercise in contrast with the noninjury-prone, anatomically opposing common digital extensor tendon (CDET). Previous studies have indicated low levels of cellular activity in the mature SDFT, but in foal tendons the tenocytes may still have the ability to adapt positively to increased exercise. OBJECTIVES: To measure tenocyte densities and types in histological sections from the SDFT and CDET of horses from controlled long-term, short-term and foal exercise studies. METHODS: Specimens were collected from mid-metacarpal segments of the CDET and SDFT for each horse and processed for histology; central and peripheral regions of the SDFT cross-section were analysed separately (SDFTc, SDFTp). Tenocyte nuclei were counted in a total area of 1.59 mm(2) for each tendon region in each horse. Each nucleus was classified as type 1 (elongate and thin), type 2 (ovoid and plump) or type 3 (chondrocyte-like); type 1 cells are proposed to be less synthetically active than type 2 cells. RESULTS: No significant differences were noted between exercise and control groups in any of the studies, with the exception of an exercise-related reduction in the proportion of type 1 tenocytes for all tendons combined in the long-term study. There were tendon- and site-specific differences in tenocyte densities and proportions of type 1 and 2 cells in all 3 studies. CONCLUSIONS AND POTENTIAL RELEVANCE: There was no indication that exercise increased tenocyte density or proportions of the (theoretically) more active type 2 cells in immature horses (short-term and foal studies), perhaps because the training regimens did not achieve certain threshold strain levels. In the foal study these findings can still be interpreted positively as evidence that the training regimen did not induce subclinical damage.


Assuntos
Envelhecimento/fisiologia , Cavalos/crescimento & desenvolvimento , Condicionamento Físico Animal/fisiologia , Tendões/citologia , Tendões/crescimento & desenvolvimento , Envelhecimento/patologia , Análise de Variância , Animais , Contagem de Células/veterinária , Feminino , Membro Anterior/patologia , Membro Anterior/fisiologia , Cavalos/lesões , Processamento de Imagem Assistida por Computador , Masculino , Condicionamento Físico Animal/efeitos adversos , Distribuição Aleatória , Estresse Mecânico , Traumatismos dos Tendões/patologia , Traumatismos dos Tendões/prevenção & controle , Traumatismos dos Tendões/veterinária , Tendões/patologia
12.
Equine Vet J ; 40(2): 136-40, 2008 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-18093890

RESUMO

REASON FOR PERFORMING STUDY: Conditioning by early training may influence the composition of certain musculoskeletal tissues, but very few data exist on its effect during growth on tendon structure and function. OBJECTIVES: To investigate whether conditioning exercise in young foals would lead to any ultrasonographically detectable damage to the superficial digital flexor tendon or an increase in cross-sectional area (CSA). METHODS: Thirty-three Thoroughbred foals reared at pasture were allocated to 2 groups: control (PASTEX) allowed exercise freely at pasture; and CONDEX, also at pasture, began conditioning exercise from mean age 21 days over 1030 m on a purpose-built oval grass track, for 5 days/week until mean age 18 months. Foals were observed daily, and underwent orthopaedic examination monthly. Ultrasonographic images of the superficial digital flexor tendon (SDFT) at the mid-metacarpal level of both forelimbs were obtained in all foals at ages 5, 8, 12, 15 and 18 months. CSA was validated (r(2) = 0.89) by determining CSA from digital photographs of the transected SDFT surface from 12 of the horses necropsied at age 17.1 months. RESULTS: here was no clinical or ultrasonographic evidence of tendonopathy in either group and the greatest increase in mean CSA in both groups occurred between age 5 and 8 months. Across all age categories, there was no significant difference in mean CSA between the left and right limbs, or colts and fillies; there was a trend towards a larger CSA in the CONDEX group (P = 0.058). CONCLUSIONS: There was no conclusive evidence for a structural adaptive hypertrophy of the SDFT, probably because the regimen was insufficiently rigorous or because spontaneous pasture exercise may induce maximal development of energy storing tendons. POTENTIAL RELEVANCE: A moderate amount of early conditioning exercise against a background of constant exercise at pasture is not harmful to the development of the flexor tendons.


Assuntos
Cavalos/fisiologia , Condicionamento Físico Animal/fisiologia , Tendões/diagnóstico por imagem , Tendões/crescimento & desenvolvimento , Adaptação Fisiológica , Animais , Animais Recém-Nascidos , Feminino , Doenças dos Cavalos/epidemiologia , Doenças dos Cavalos/prevenção & controle , Cavalos/crescimento & desenvolvimento , Hipertrofia/epidemiologia , Hipertrofia/prevenção & controle , Hipertrofia/veterinária , Masculino , Condicionamento Físico Animal/efeitos adversos , Distribuição Aleatória , Traumatismos dos Tendões/epidemiologia , Traumatismos dos Tendões/prevenção & controle , Traumatismos dos Tendões/veterinária , Ultrassonografia
13.
Equine Vet J ; 40(2): 119-27, 2008 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-18093893

RESUMO

REASON FOR PERFORMING STUDY: No data exist on the effects of conditioning exercise at foal age on workload and subsequent clinical injury rate during their 2- and 3-year-old racing careers. OBJECTIVES: To investigate the effects of subjecting TB foals to conditioning exercise prior to the start of race training on: the workload required to reach a level of fitness sufficient to compete; and the prevalence of orthopaedic injury during the first 2 seasons of their racing careers. METHODS: Twenty 18-month-old TBs, 12 subjected to conditioning exercise at foal age (CONDEX) and 8 exercised spontaneously at pasture only (PASTEX) were trained and entered in competitive events. Workload was quantified using the cumulative workload index (the product of average velocity and distance at a specific gait) and the animals were monitored clinically and radiographically for signs of musculoskeletal disorders. RESULTS: Workload to reach the desired fitness level was similar for CONDEX and PASTEX. CONDEX performed more prerace training sessions as 2-year-olds (P<0.05). The incidence of orthopaedic injuries was low in both groups and there were no differences in the occurrence of orthopaedic ailments. PASTEX animals tended to show signs of musculoskeletal disorders earlier than CONDEX animals. This time difference was significant for metacarpophalangeal joint pain on flexion, reduced carpal flexion and hindlimb lameness (P<0.05). CONCLUSIONS: Subjecting TB foals to conditioning exercise early in life does not have adverse effects on racing careers at ages 2 and 3 years, and does not influence the workload needed to reach a fitness level that is sufficient for racing. POTENTIAL RELEVANCE: The lack of negative effects and the indications of some positive effects of early conditioning exercise in the Thoroughbred encourage further large-scale comparative studies.


Assuntos
Doenças dos Cavalos/epidemiologia , Cavalos/crescimento & desenvolvimento , Cavalos/lesões , Desenvolvimento Musculoesquelético/fisiologia , Doenças Musculoesqueléticas/veterinária , Condicionamento Físico Animal , Ferimentos e Lesões/veterinária , Animais , Feminino , Doenças dos Cavalos/etiologia , Artropatias/epidemiologia , Artropatias/etiologia , Artropatias/veterinária , Coxeadura Animal/epidemiologia , Masculino , Doenças Musculoesqueléticas/epidemiologia , Doenças Musculoesqueléticas/etiologia , Condicionamento Físico Animal/efeitos adversos , Condicionamento Físico Animal/fisiologia , Aptidão Física/fisiologia , Distribuição Aleatória , Esportes , Ferimentos e Lesões/epidemiologia , Ferimentos e Lesões/etiologia
14.
Equine Vet J ; 40(2): 111-8, 2008 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-18093894

RESUMO

REASON FOR PERFORMING STUDY: No data exist on the intensity of exercise required or on possible harmful effects of increasing exercise in foals over the natural level when free at pasture. OBJECTIVES: To investigate whether an increase in workload over free pasture exercise in the period from directly after birth to the start of training is tolerated by Thoroughbred (TB) foals without increasing injury rate or producing other undesired side effects. METHODS: Thirty-three TB foals were allocated to one of 2 exercise groups directly after birth. One group (PASTEX) was raised on pasture and the other (CONDEX) kept under identical circumstances, but was additionally subjected to an exercise protocol of gradually increasing intensity. Foals were monitored periodically and scored for the presence of clinical signs related to the musculoskeletal system (joint effusion, pain at flexion, occurrence of physeal swelling), and radiographs taken at the end of the conditioning phase. Also, behavioural studies were performed to detect any changes in behaviour related to the exercise programme. Cortisol levels were measured in both groups, to assess the level of stress. RESULTS: Workload in the CONDEX group was significantly higher than in the PASTEX group (approximately 30%). Conditioning increased the likelihood for joint effusion in the antebrachiocarpal joint, but reduced tarsocrural effusion and physeal swelling at the lateral distal radius, the third metacarpal bone (medial aspect) and lateral and medial aspects of the third metatarsal bone. CONCLUSIONS: The 30% increase in workload did not affect the animals' welfare, effects of conditioning exercise on clinical musculoskeletal health were few and there were no adverse effects. POTENTIAL RELEVANCE: This study supports the feasibility of imposing early conditioning exercise in horses and is a benchmark for its effects on the development of equine musculoskeletal tissues.


Assuntos
Desenvolvimento Ósseo/fisiologia , Cavalos/crescimento & desenvolvimento , Desenvolvimento Musculoesquelético/fisiologia , Condicionamento Físico Animal/fisiologia , Envelhecimento/sangue , Envelhecimento/fisiologia , Criação de Animais Domésticos/métodos , Animais , Animais Recém-Nascidos/crescimento & desenvolvimento , Feminino , Doenças dos Cavalos/etiologia , Cavalos/sangue , Hidrocortisona/sangue , Artropatias/etiologia , Artropatias/veterinária , Masculino , Condicionamento Físico Animal/efeitos adversos , Distribuição Aleatória
15.
J Appl Physiol (1985) ; 102(6): 2194-200, 2007 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-17332271

RESUMO

Adaptation of osteochondral tissues is based on the strains experienced during exercise at each location within the joint. Different exercise intensities and types may induce particular site-specific strains, influencing osteochondral adaptation and potentially predisposing to injury. Our hypotheses were that patterns of equine distal tarsal subchondral bone (SCB) thickness relate to the type and intensity of exercise, and that high-intensity exercise leads to site-specific increases in thickness. SCB thickness was measured at defined dorsal and plantar locations on magnetic resonance images of cadaver tarsi collected from horses with a history of low [general purpose (n=20) and horse walker (n=6)] or high [elite competition (n=12), race training (n=15), and treadmill training (n=4)] exercise intensity. SCB thickness was compared between sites within each exercise group and between exercise groups. SCB thickness in elite competition and race training, but not treadmill training, was greater than low-intensity exercise. For general purpose horses, lateral SCB thickness was greater than medial throughout. Horse walker exercise led to relatively thicker lateral and medial SCB compared with the midline. Elite competition was associated with increased SCB thickness of the proximal small tarsal bones medially and the distal bones laterally. For race training and treadmill training, there were minimal differences between sites overall, although the lateral aspect was greater than medial, and medial greater than midline at a few sites for race training. In conclusion, different types of high-intensity exercise were associated with different patterns of SCB thickness across the joints from medial to lateral and proximal to distal, indicating that both exercise intensity and type of exercise affect the SCB response at any particular site within the equine distal tarsal joints.


Assuntos
Tornozelo/anatomia & histologia , Tornozelo/fisiologia , Cavalos/anatomia & histologia , Cavalos/fisiologia , Condicionamento Físico Animal/métodos , Resistência Física/fisiologia , Esforço Físico/fisiologia , Adaptação Fisiológica/fisiologia , Animais , Técnicas In Vitro
16.
Equine Vet J ; 39(2): 101-5, 2007 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-17378437

RESUMO

REASONS FOR PERFORMING STUDY: Understanding of the development of pathology and source of pain in distal tarsal osteoarthritis is poorly understood. Magnetic resonance imaging is often used in the analysis of human osteoarthritis (OA) because it is sensitive to early changes. HYPOTHESIS: In association with distal tarsal joint (DTJ) pain, there will be an alteration in the characteristic subchondral bone (SCB) thickness pattern of horses with no history of pain when subjected to low-level exercise. METHODS: Sixteen cadaver tarsal joints were collected from 9 mature horses with a history of tarsal pain and radiographic evidence of OA; 3 cadaver tarsi were collected from 2 mature horses with a history of tarsal pain and no radiographic abnormality. Magnetic resonance images were acquired using high-resolution sagittal 3D T1 weighted spoiled gradient echo sequence. Subchondral bone thickness was measured on sagittal images at dorsal and plantar locations on the proximal and distal aspects of the central (CT) and third (T3) tarsal bones and proximal aspect of the third metatarsal bone (MT3). RESULTS: In tarsi with radiographic evidence of OA medial and lateral SCB thicknesses were greater than midline on the proximal and distal aspects of CT and T3. Lateral SCB thickness was greater than medial on the proximal aspect of MT3. There was an increase in SCB thickness at the majority of sites compared with normal horses. There were too few joints in the group without radiographic changes to analyse statistically. In painful tarsi SCB thickness was greater medially than laterally at all sites. In horses without tarsal pain all lateral sites had greater SCB thickness, except the proximal aspect of CT. CONCLUSIONS: There is alteration of normal SCB thickness patterns in painful tarsi. Different thickness patterns could represent different types of pathological processes. POTENTIAL CLINICAL RELEVANCE: Further work is required to elucidate the pathological processes leading to OA of the DTJs.


Assuntos
Artralgia/veterinária , Doenças dos Cavalos/etiologia , Osteoartrite/veterinária , Tarso Animal/anatomia & histologia , Tarso Animal/patologia , Animais , Artralgia/diagnóstico , Artralgia/etiologia , Artralgia/patologia , Osso e Ossos/anatomia & histologia , Osso e Ossos/patologia , Cadáver , Feminino , Doenças dos Cavalos/diagnóstico , Doenças dos Cavalos/patologia , Cavalos , Coxeadura Animal/diagnóstico , Coxeadura Animal/etiologia , Coxeadura Animal/patologia , Imageamento por Ressonância Magnética/métodos , Imageamento por Ressonância Magnética/veterinária , Masculino , Osteoartrite/diagnóstico , Osteoartrite/etiologia , Osteoartrite/patologia , Articulações Tarsianas/anatomia & histologia , Articulações Tarsianas/patologia
17.
J Orthop Res ; 24(7): 1377-83, 2006 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-16732606

RESUMO

To evaluate soft tissue reactions and biofilm formation on percutaneous external fixator screws coated with diamond-like carbon (DLC) and hydroxyapatite (HA) coatings on stainless-steel (SS) pins in an ovine loaded osteotomy model, an Orthofix external fixator was used to stabilize a 3-mm tibial midshaft osteotomy with six tapered pins inserted into the right tibia of 32 skeletally mature Friesland ewes. Animals were divided into four groups; SS, fully coated HA, DLC, and HA-coated threads. At 10 weeks, specimens were harvested and the pins were removed en bloc to examine the interfaces between the surface coatings and the tissues. Fully coated HA pins had a significantly higher percentage of dermal contact with the pin surface than HA-coated threads (p=0.028). The presence of a biofilm was evident on all pin surfaces except DLC-coated pins. Significantly greater numbers of bacteria were present on fully coated HA and plain stainless-steel pins compared with DLC. The surface of DLC-coated pins had a significantly lower number of bacterial colonies compared to SS (p=0.028) and fully coated HA pins (p=0.005). Fully coated HA pins have greater dermal attachment to the pin surface than the other pin coatings investigated. DLC-coated pins have the potential to prevent biofilm formation and bacterial colonization that may reduce infection and consequent pin loosening. An external fixator pin that is partially coated with HA to encourage bone and soft tissue integration and with DLC to reduce biofilm formation is advocated.


Assuntos
Carbono/farmacologia , Materiais Revestidos Biocompatíveis/farmacologia , Durapatita/farmacologia , Fixadores Externos , Pele/efeitos dos fármacos , Animais , Biofilmes/efeitos dos fármacos , Fixadores Externos/microbiologia , Feminino , Microscopia Eletrônica de Transmissão , Osteotomia/métodos , Infecções Relacionadas à Prótese/prevenção & controle , Ovinos , Pele/anatomia & histologia , Pele/microbiologia , Tíbia/cirurgia , Torque
18.
J Bone Joint Surg Br ; 88(4): 544-53, 2006 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-16567795

RESUMO

Bovine and human articular chondrocytes were seeded in 2% alginate constructs and cultured for up to 19 days in a rotating-wall-vessel (RWV) and under static conditions. Culture within the RWV enhanced DNA levels for bovine chondrocyte-seeded constructs when compared with static conditions but did not produce enhancement for human cells. There was a significant enhancement of glycosaminoglycans and hydroxyproline synthesis for both bovine and human chondrocytes. In all cases, histological analysis revealed enhanced Safranin-O staining in the peripheral regions of the constructs compared with the central region. There was an overall increase in staining intensity after culture within the RWV compared with static conditions. Type-II collagen was produced by both bovine and human chondrocytes in the peripheral and central regions of the constructs and the staining intensity was enhanced by culture within the RWV. A capsule of flattened cells containing type-I collagen developed around the constructs maintained under static conditions when seeded with either bovine or human chondrocytes, but not when cultured within the RWV bioreactor.


Assuntos
Reatores Biológicos , Cartilagem Articular/citologia , Técnicas de Cultura de Células/métodos , Condrócitos/fisiologia , Hidrogel de Polietilenoglicol-Dimetacrilato , Alginatos/química , Animais , Bovinos , Divisão Celular , Colágeno Tipo I/análise , Colágeno Tipo II/análise , Meios de Cultura , DNA/análise , Matriz Extracelular/química , Matriz Extracelular/fisiologia , Glicosaminoglicanos/análise , Humanos , Hidroxiprolina/análise , Indicadores e Reagentes/análise , Fenazinas/análise
19.
J Bone Joint Surg Br ; 88(9): 1245-51, 2006 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-16943481

RESUMO

We examined the mechanical properties of Vicryl (polyglactin 910) mesh in vitro and assessed its use in vivo as a novel biomaterial to attach tendon to a hydroxyapatite-coated metal implant, the interface of which was augmented with autogenous bone and marrow graft. This was compared with tendon re-attachment using a compressive clamp device in an identical animal model. Two- and four-ply sleeves of Vicryl mesh tested to failure under tension reached 5.13% and 28.35% of the normal ovine patellar tendon, respectively. Four-ply sleeves supported gait in an ovine model with 67.05% weight-bearing through the operated limb at 12 weeks, without evidence of mechanical failure. Mesh fibres were visible at six weeks but had been completely resorbed by 12 weeks, with no evidence of chronic inflammation. The tendon-implant neoenthesis was predominantly an indirect type, with tendon attached to the bone-hydroxyapatite surface by perforating collagen fibres.


Assuntos
Materiais Biocompatíveis , Poliglactina 910/uso terapêutico , Implantação de Prótese/métodos , Tendões/cirurgia , Tíbia/cirurgia , Animais , Cadáver , Materiais Revestidos Biocompatíveis , Durapatita , Desenho de Equipamento , Feminino , Membro Posterior , Metais , Modelos Anatômicos , Patela/cirurgia , Desenho de Prótese , Ovinos , Telas Cirúrgicas , Suporte de Carga/fisiologia
20.
J Bone Joint Surg Br ; 88(4): 449-54, 2006 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-16567777

RESUMO

We have studied the relationship between metal ion levels and lymphocyte counts in patients with metal-on-metal hip resurfacings. Peripheral blood samples were analysed for lymphocyte subtypes and whole blood cobalt and chromium ion levels in 68 patients (34 with metal-on-metal hip resurfacings and 34 with standard metal-on-polyethylene total hip replacements). All hip components were radiologically well-fixed and the patients were asymptomatic. Cobalt and chromium levels were significantly elevated in the patients with metal-on-metal hip resurfacings, compared with the patients with standard metal-on-polyethylene designs (p < 0.0001). There was a statistically significant decrease in the level of CD8(+) cells (T-cytotoxic/suppressor) (p = 0.005) in the metal-on-metal hip resurfacing group. A threshold level of blood cobalt and chromium ions was associated with reduced CD8(+) T-cell counts. We have no evidence that our patients suffered as a result of this reduced level of CD8(+) T-cells.


Assuntos
Linfócitos T CD8-Positivos/imunologia , Cromo/sangue , Cobalto/sangue , Prótese de Quadril , Adulto , Idoso , Feminino , Humanos , Contagem de Linfócitos , Masculino , Pessoa de Meia-Idade , Polietileno , Desenho de Prótese
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA