Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Surg Technol Int ; 39: 317-320, 2021 10 26.
Artigo em Inglês | MEDLINE | ID: mdl-34699598

RESUMO

Caval filters are placed in the inferior vena cava (IVC) to prevent pulmonary thromboembolism in patients with deep vein thrombosis. If there is no indication for thrombo-embolic risk prevention, the filter can be removed to reduce potential filter-related complications. Advanced endovascular techniques are frequently used to retrieve IVC filters. We describe an alternative filter-removal technique for use when standard techniques are not practicable. In our method, the filter hook is embedded within the IVC wall. To retrieve it, a long introducer is inserted; a guidewire and the "loop snare" retrieval system are then advanced through it with a coaxial system and positioned below the filter at the level of the common iliac vein confluence. The guidewire is then passed through the loop, creating a "sling" around the filter which allows the application of traction from the bottom upwards, releasing the hook from the wall. The loop is then held under tension with the filter aligned in the IVC lumen, and the introducer is advanced distally to completely cover the filter, allowing complete retrieval of the filter without damaging the vessel walls. This modified Sling technique is a safe and feasible method for complicated IVC filter retrieval.


Assuntos
Procedimentos Endovasculares , Filtros de Veia Cava , Remoção de Dispositivo , Humanos , Estudos Retrospectivos , Resultado do Tratamento , Veia Cava Inferior/cirurgia
2.
Technol Cancer Res Treat ; 22: 15330338231181284, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37608564

RESUMO

Tumor ablation is included in several major cancer therapy guidelines. One technical challenge of percutaneous ablation is targeting and verification of complete treatment, which is prone to operator variabilities and human imperfections and are directly related to successful outcomes, risk for residual unablated tumor and local progression. The use of "Prediction Ablation Volume Software" may help the operating Interventional Radiologist to better plan, deliver, and verify before the ablation, via virtual treatment zones fused to target tumor. Fused and superimposed images provide 3-dimensional information from different timepoints, just when that information is most useful. The aim of this study is to evaluate the technical success and efficacy of an ablation treatment flowchart provided by a cone beam computed tomography (CBCT) "Prediction Ablation Volume Software." This is a single-center retrospective study. From April 2021 to January 2022, 29 nonconsecutive evaluable patients with 32 lesions underwent liver ablation with Prediction Ablation Volume Software. Each patient was discussed in a multidisciplinary tumor board and underwent an enhanced computed tomography or magnetic resonance imaging approximately 1 month before the procedure, as well as ∼1 month after. Technical success was defined as treatment of the tumor according to the protocol, covered completely by the Prediction Ablation Volume. Technical efficacy was defined as assessment of complete ablation of the target tumor at imaging follow up (∼1 month). Technical success, technical efficacy, and procedural factors were studied. Technical success was achieved in 30 of 32 liver lesions (94%), measuring 20 mm mean maximum diameter. The antenna was repositioned in 16 of 30 (53%) evaluable target lesions. Residual tumor was detected at 1 month imaging follow up in only 4 of 30 (13%) of the treated lesion. Technical efficacy was of 87% in this retrospective description of our process. The implementation of a CBCT Prediction Ablation Volume Software and flowchart for the treatment of liver malignancies altered the procedure, and demonstrated high technical success and efficacy. Such tools are potentially useful for procedural prediction and verification of ablation.


Assuntos
Ablação por Cateter , Neoplasias Hepáticas , Humanos , Estudos Retrospectivos , Micro-Ondas/uso terapêutico , Resultado do Tratamento , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/radioterapia , Neoplasias Hepáticas/cirurgia , Tomografia Computadorizada de Feixe Cônico/métodos , Ablação por Cateter/métodos
3.
J Clin Med ; 12(24)2023 Dec 09.
Artigo em Inglês | MEDLINE | ID: mdl-38137667

RESUMO

PURPOSE: to evaluate the clinical impact of a protocol for the image-guided percutaneous microwave ablation (MWA) of hepatocellular carcinoma (HCC) that includes cone-beam computed tomography (CBCT), fusion imaging and ablation volume prediction in patients with hepatocellular carcinoma unsuitable for standard ultrasound (US) guidance. MATERIALS AND METHODS: this study included all patients with HCC treated with MWA between January 2021 and June 2022 in a tertiary institution. Patients were divided into two groups: Group A, treated following the protocol, and Group B, treated with standard ultrasound (US) guidance. Follow-up images were reviewed to assess residual disease (RD), local tumor progression (LTP) and intrahepatic distant recurrence (IDR). Ablation response at 1 month was also evaluated according to mRECIST. Baseline variables and outcomes were compared between the groups. For 1-month RD, propensity score weighting (PSW) was performed. RESULTS: 80 consecutive patients with 101 HCCs treated with MWA were divided into two groups. Group A had 41 HCCs in 37 patients, and Group B had 60 HCCs in 43 patients. Among all baseline variables, the groups differed regarding their age (mean of 72 years in Group A and 64 years in Group B, respectively), new vs. residual tumor rates (48% Group A vs. 25% Group B, p < 0.05) and number of subcapsular tumors (56.7% Group B vs. 31.7% Group A, p < 0.05) and perivascular tumors (51.7% Group B vs. 17.1% Group A, p < 0.05). The protocol led to repositioning the antenna in 49% of cases. There was a significant difference in 1-month local response between the groups measured as the RD rate and mRECIST outcomes. LTP rates at 3 and 6 months, and IDR rates at 1, 3 and 6 months, showed no significant differences. Among all variables, logistic regression after PSW demonstrated a protective effect of the protocol against 1-month RD. CONCLUSIONS: The use of CBCT, fusion imaging and ablation volume prediction during percutaneous MWA of HCCs provided a better 1-month tumor local control. Further studies with a larger population and longer follow-up are needed.

4.
Tomography ; 8(5): 2475-2485, 2022 09 30.
Artigo em Inglês | MEDLINE | ID: mdl-36287805

RESUMO

BACKGROUND: Percutaneous Microwave Ablation (MWA) of lung malignancies is a procedure with many technical challenges, among them the risk of residual disease. Recently, dedicated software able to predict the volume of the ablated area was introduced. Cone-beam computed tomography (CBCT) is the imaging guidance of choice for pulmonary ablation in our institution. The volumetric prediction software (VPS) has been installed and used in combination with CBCT to check the correct position of the device. Our study aimed to compare the results of MWA of pulmonary tumours performed using CBCT with and without VPS. METHODS: We retrospectively reviewed 1-month follow-up enhanced contrast-enhanced computed tomography (CECT) scans of 10 patients who underwent ablation with the assistance of VPS (group 1) and of 10 patients who were treated without the assistance of VPS (group 2). All patients were treated for curative purposes, the maximum axial diameter of lesions ranged between 5 and 22 mm in group 1 and between 5 and 25 mm in group 2. We compared the presence of residual disease between the two groups. RESULTS: In group 1 residual disease was seen in only 1 patient (10%) in which VPS had ensured complete coverage of the tumour. In group 2 residual disease was found in 3 patients (30%). CONCLUSIONS: Using this software during MWA of lung malignancies could improve the efficacy of the treatment compared to the conventional only CBCT guidance.


Assuntos
Ablação por Cateter , Neoplasias Pulmonares , Humanos , Estudos Retrospectivos , Micro-Ondas/uso terapêutico , Ablação por Cateter/métodos , Pulmão/cirurgia , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/cirurgia
5.
Semin Ultrasound CT MR ; 42(1): 85-94, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33541592

RESUMO

The strict correlation between abnormal invasive placentation and postpartum hemorrhage suggests that a widespread antenatal diagnosis of placental anomalies would improve the management of these challenging patients; acting preventive solutions at the moment of delivery reduces blood loss and avoid hysterectomies. The role of endovascular procedures in this field has been encouraged by multiple studies reporting prophylactic uterine arteries embolization and iliac/aortic balloon catheters positioning. This paper aims to review the main imaging diagnostic findings of placental implant anomalies and summarize the principal preventive endovascular strategies proposed in literature.


Assuntos
Procedimentos Endovasculares/métodos , Imageamento por Ressonância Magnética/métodos , Hemorragia Pós-Parto/diagnóstico por imagem , Hemorragia Pós-Parto/prevenção & controle , Ultrassonografia/métodos , Feminino , Humanos , Hemorragia Pós-Parto/cirurgia , Gravidez
6.
Intern Emerg Med ; 16(3): 749-756, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33090353

RESUMO

The diffusion of the severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) worldwide prompted the World Health Organization to declare the status of pandemic. The molecular diagnosis of SARS-CoV-2 infection is based on the detection of viral RNA on different biological specimens. Unfortunately, the test may require several hours to be performed. In the present study, we evaluated the diagnostic accuracy of lung point-of-care ultrasound (POCUS) for SARS-CoV-2 pneumonia in a cohort of symptomatic patients admitted to one emergency department (ED) in a high-prevalence setting. This retrospective study enrolled all patients who visited one ED with suspected respiratory infection in March 2020. All the patients were tested (usually twice if the first was negative) for SARS-CoV-2 on ED admission. The reference standard was considered positive if at least one specimen was positive. If all the specimens tested negative, the reference was considered negative. Diagnostic accuracy was evaluated using sensitivity, specificity, and positive and negative predictive value. Of the 444 symptomatic patients who were admitted to the ED in the study period, the result of the lung POCUS test was available for 384 (86.5%). The sensitivity of the test was 92.0% (95% CI 88.2-94.9%), and the specificity was 64.9% (95% CI 54.6-74.4%). We observed a prevalence of SARS-CoV-2 infection of 74.7%. In this setting, the positive and negative predicted values were 88.6% (95% CI 84.4-92.0) and 73.3% (95% CI 62.6-82.2%), respectively. Lung POCUS is a sensitive first-line screening tool for ED patients presenting with symptoms suggestive of SARS-CoV-2 infection.


Assuntos
COVID-19/diagnóstico por imagem , Pneumonia Viral/diagnóstico por imagem , Ultrassonografia/métodos , Idoso , COVID-19/epidemiologia , Teste para COVID-19 , Diagnóstico Diferencial , Serviço Hospitalar de Emergência , Feminino , Humanos , Itália/epidemiologia , Masculino , Pessoa de Meia-Idade , Pandemias , Pneumonia Viral/epidemiologia , Pneumonia Viral/virologia , Sistemas Automatizados de Assistência Junto ao Leito , SARS-CoV-2 , Sensibilidade e Especificidade
7.
Med Oncol ; 37(5): 41, 2020 Apr 07.
Artigo em Inglês | MEDLINE | ID: mdl-32266568

RESUMO

To retrospectively assess the predictive value of the CT performed at 24 h, compared with the CT performed at 1 month, in the evaluation of the technical success of microwave (MW) ablation of hepatic lesions. In a single center, 50 patients with HCC underwent percutaneous MW ablation between November 2016 and March 2019. Each patient underwent a contrast-enhanced CT exam at 24 h and at 1 month after the procedure. For each patient, was assessed the presence or absence of residual disease, the appearance of a new lesion, complications, and the involvement of the hepatic capsule, both at 24-h and at 1 month. Overall correlation between residual disease, appearance of a new nodule and complications was also assessed. A total of 50 hepatic lesions were treated with US-guided MW ablation. Patients' mean age was 70.9 years (range 28-87 years). Mean nodule diameter was 17.6 mm (range 7-35 mm). Contingency tables and the χ2 test showed a strong association when looking at capsule involvement (accuracy: 100%), residual disease (accuracy: 90%; p-value 0.003), and the appearance of a new HCC nodule (accuracy: 88%; p-value 0.007); regarding complications, the accuracy was 78% (p-value 0.014). Optimal correlation was reached in 62% of cases, moderate correlation in 26%, minimum correlation in 10% of cases; no cases of zero correlation were recorded. CT at 24 h and 1 month showed comparable efficacy in evaluating residual disease after MW thermal ablation of liver lesions. However, further studies are needed to assess which factors may cause false-negative results at the 24-h CT.


Assuntos
Carcinoma Hepatocelular/diagnóstico por imagem , Neoplasias Hepáticas/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Adulto , Idoso , Idoso de 80 Anos ou mais , Carcinoma Hepatocelular/patologia , Carcinoma Hepatocelular/cirurgia , Ablação por Cateter , Feminino , Seguimentos , Humanos , Fígado/diagnóstico por imagem , Fígado/patologia , Fígado/cirurgia , Neoplasias Hepáticas/patologia , Neoplasias Hepáticas/cirurgia , Masculino , Micro-Ondas/uso terapêutico , Pessoa de Meia-Idade , Neoplasia Residual , Estudos Retrospectivos , Cirurgia Assistida por Computador , Fatores de Tempo , Resultado do Tratamento , Ultrassonografia
8.
Acta Biomed ; 91(10-S): e2020007, 2020 09 23.
Artigo em Inglês | MEDLINE | ID: mdl-33245074

RESUMO

Bone metastases are a common cause of cancer-related debilitating pain, especially when -localized in the vertebral column and not responsive to standard treatment. In such cases, various treatment options are available; among these is Radiofrequency, whose role has been rapidly growing over the past few years. In this study, we used the innovative Osteocool RF Ablation System (Medtronic) on a patient with a painful bone metastasis localized in the 5th lumbar vertebra, with encouraging results. The radiofrequency ablation of bone metastases with palliative aim represents an excellent treatment option, as it is a minimally invasive and safe procedure, and can be repeated multiple times.


Assuntos
Ablação por Radiofrequência , Neoplasias da Coluna Vertebral , Humanos , Dor , Cuidados Paliativos , Neoplasias da Coluna Vertebral/cirurgia , Tecnologia , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA