Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 66
Filtrar
1.
Radiology ; 312(2): e240229, 2024 08.
Artigo em Inglês | MEDLINE | ID: mdl-39136569

RESUMO

Background Quantifying the fibrotic and calcific composition of the aortic valve at CT angiography (CTA) can be useful for assessing disease severity and outcomes of patients with aortic stenosis (AS); however, it has not yet been validated against quantitative histologic findings. Purpose To compare quantification of aortic valve fibrotic and calcific tissue composition at CTA versus histologic examination. Materials and Methods This prospective study included patients who underwent CTA before either surgical aortic valve replacement for AS or orthotopic heart transplant (controls) at two centers between January 2022 and April 2023. At CTA, fibrotic and calcific tissue composition were quantified using automated Gaussian mixture modeling applied to the density of aortic valve tissue components, calculated as [(volume/total tissue volume) × 100]. For histologic evaluation, explanted valve cusps were stained with Movat pentachrome as well as hematoxylin and eosin. For each cusp, three 5-µm slices were obtained. Fibrotic and calcific tissue composition were quantified using a validated artificial intelligence tool and averaged across the aortic valve. Correlations were assessed using the Spearman rank correlation coefficient. Intermodality and interobserver variability were measured using the intraclass correlation coefficient (ICC) and Bland-Altman plots. Results Twenty-nine participants (mean age, 63 years ± 10 [SD]; 23 male) were evaluated: 19 with severe AS, five with moderate AS, and five controls. Fibrocalcific tissue composition strongly correlated with histologic findings (r = 0.92; P < .001). The agreement between CTA and histologic findings for fibrocalcific tissue quantification was excellent (ICC, 0.94; P = .001), with underestimation of fibrotic composition at CTA (bias, -4.9%; 95% limits of agreement [LoA]: -18.5%, 8.7%). Finally, there was excellent interobserver repeatability for fibrotic (ICC, 0.99) and calcific (ICC, 0.99) aortic valve tissue volume measurements, with no evidence of a difference in measurements between readers (bias, -0.04 cm3 [95% LoA: -0.27 cm3, 0.19 cm3] and 0.02 cm3 [95% LoA: -0.14 cm3, 0.19 cm3], respectively). Conclusion In a direct comparison, standardized quantitative aortic valve tissue characterization at CTA showed excellent concordance with histologic findings and demonstrated interobserver reproducibility. Clinical trial registration no. NCT06136689 Published under a CC BY 4.0 license. Supplemental material is available for this article. See also the editorial by Almeida in this issue.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Calcinose , Angiografia por Tomografia Computadorizada , Fibrose , Humanos , Masculino , Estudos Prospectivos , Feminino , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/patologia , Pessoa de Meia-Idade , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/patologia , Estenose da Valva Aórtica/cirurgia , Calcinose/diagnóstico por imagem , Calcinose/patologia , Fibrose/diagnóstico por imagem , Angiografia por Tomografia Computadorizada/métodos , Idoso
2.
Curr Atheroscler Rep ; 26(7): 305-315, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38727963

RESUMO

PURPOSE OF REVIEW: Despite recent advances, coronary artery disease remains one of the leading causes of mortality worldwide. Noninvasive imaging allows atherosclerotic phenotyping by measurement of plaque burden, morphology, activity and inflammation, which has the potential to refine patient risk stratification and guide personalized therapy. This review describes the current and emerging roles of advanced noninvasive cardiovascular imaging methods for the assessment of coronary artery disease. RECENT FINDINGS: Cardiac computed tomography enables comprehensive, noninvasive imaging of the coronary vasculature, and is used to assess luminal stenoses, coronary calcifications, and distinct adverse plaque characteristics, helping to identify patients prone to future events. Novel software tools, implementing artificial intelligence solutions, can automatically quantify and characterize atherosclerotic plaque from standard computed tomography datasets. These quantitative imaging biomarkers have been shown to improve patient risk stratification beyond clinical risk scores and current clinical interpretation of cardiac computed tomography. In addition, noninvasive molecular imaging in higher risk patients can be used to assess plaque activity and plaque thrombosis. Noninvasive imaging allows unique insight into the burden, morphology and activity of atherosclerotic coronary plaques. Such phenotyping of atherosclerosis can potentially improve individual patient risk prediction, and in the near future has the potential for clinical implementation.


Assuntos
Doença da Artéria Coronariana , Fenótipo , Placa Aterosclerótica , Humanos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/patologia , Doença da Artéria Coronariana/diagnóstico , Placa Aterosclerótica/diagnóstico por imagem , Placa Aterosclerótica/patologia , Tomografia Computadorizada por Raios X , Angiografia por Tomografia Computadorizada/métodos , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/patologia , Medição de Risco/métodos
3.
Int J Mol Sci ; 25(17)2024 Sep 05.
Artigo em Inglês | MEDLINE | ID: mdl-39273580

RESUMO

In end-stage heart failure, which is characterized by persistent or progressive ventricular dysfunction despite optimal medical therapy, a left ventricular assist device (LVAD) can be beneficial. Congestive heart failure provokes inflammatory and prothrombotic activation. The aim of this study was to evaluate the serum concentration of citrullinated histone 3 (CH3) representing neutrophil extracellular trap (NET) formation in patients referred for LVAD implantation. There were 10 patients with a median age of 61 (57-65) years enrolled in a prospective single-center analysis who underwent LVAD implantation. The CH3 plasma concentration was measured preoperatively and on the 1st and 7th postoperative days, followed by control measurements on the median (Q1-3) 88th (49-143) day. The preoperative CH3 concentration strongly correlated with brain natriuretic peptide (r = 0.879, p < 0.001). Significant differences in CH3 serum concentration were observed between pre- and postoperative measurements, including an increase on the first postoperative day (p < 0.001), as well as a decrease on the seventh day (p = 0.016) and in follow-up (p < 0.001). CH3 concentration, as a marker of NET formation, decreases after LVAD implantation.


Assuntos
Armadilhas Extracelulares , Insuficiência Cardíaca , Coração Auxiliar , Histonas , Humanos , Insuficiência Cardíaca/sangue , Insuficiência Cardíaca/terapia , Armadilhas Extracelulares/metabolismo , Pessoa de Meia-Idade , Masculino , Feminino , Idoso , Histonas/sangue , Histonas/metabolismo , Estudos Prospectivos , Biomarcadores/sangue , Neutrófilos/metabolismo , Citrulinação
4.
Medicina (Kaunas) ; 60(8)2024 Jul 27.
Artigo em Inglês | MEDLINE | ID: mdl-39202501

RESUMO

Background and Objectives: The progression of global warming results in an increased exposure to extreme heat, leading to exaggeration of preexisting diseases and premature deaths. The aim of the study was to present possible risk factors for all-cause long-term mortality in patients who underwent surgical revascularization, including an assessment of the influence of ambient temperature exposure. Materials and Methods: Retrospective analysis included 153 (123 (80%) males and 30 (20%) females) patients who underwent off-pump revascularization and were followed for a median time of 2533 (1035-3250) days. The demographical, clinical data and ambient temperature exposure were taken into analysis for prediction of all-cause mortality. Individual exposure was calculated based on the place of habitation. Results: In the multivariate logistic regression model with backward stepwise elimination method, risk factors such as dyslipidaemia (p = 0.001), kidney disease (p = 0.005), age (p = 0.006), and body mass index (p = 0.007) were found to be significant for late mortality prediction. In addition to traditional factors, environmental characteristics, including tropical nights (p = 0.043), were revealed to be significant. Conclusions: High night-time ambient temperatures known as tropical nights may be regarded as additional long-term mortality risk factor after surgical revascularization.


Assuntos
Temperatura , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Estudos Retrospectivos , Idoso , Fatores de Risco , Revascularização Miocárdica/estatística & dados numéricos , Revascularização Miocárdica/métodos , Revascularização Miocárdica/efeitos adversos , Modelos Logísticos , Doença da Artéria Coronariana/cirurgia , Doença da Artéria Coronariana/mortalidade , Doença da Artéria Coronariana/complicações , Índice de Massa Corporal
5.
J Nucl Cardiol ; 30(4): 1558-1569, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-36645580

RESUMO

BACKGROUND: Positron emission tomography (PET) is the clinical gold standard for quantifying myocardial blood flow (MBF). Pericoronary adipose tissue (PCAT) attenuation may detect vascular inflammation indirectly. We examined the relationship between MBF by PET and plaque burden and PCAT on coronary CT angiography (CCTA). METHODS: This post hoc analysis of the PACIFIC trial included 208 patients with suspected coronary artery disease (CAD) who underwent [15O]H2O PET and CCTA. Low-attenuation plaque (LAP, < 30HU), non-calcified plaque (NCP), and PCAT attenuation were measured by CCTA. RESULTS: In 582 vessels, 211 (36.3%) had impaired per-vessel hyperemic MBF (≤ 2.30 mL/min/g). In multivariable analysis, LAP burden was independently and consistently associated with impaired hyperemic MBF (P = 0.016); over NCP burden (P = 0.997). Addition of LAP burden improved predictive performance for impaired hyperemic MBF from a model with CAD severity and calcified plaque burden (P < 0.001). There was no correlation between PCAT attenuation and hyperemic MBF (r = - 0.11), and PCAT attenuation was not associated with impaired hyperemic MBF in univariable or multivariable analysis of all vessels (P > 0.1). CONCLUSION: In patients with stable CAD, LAP burden was independently associated with impaired hyperemic MBF and a stronger predictor of impaired hyperemic MBF than NCP burden. There was no association between PCAT attenuation and hyperemic MBF.


Assuntos
Doença da Artéria Coronariana , Placa Aterosclerótica , Humanos , Estudos Prospectivos , Doença da Artéria Coronariana/diagnóstico por imagem , Placa Aterosclerótica/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Tomografia por Emissão de Pósitrons , Angiografia Coronária/métodos , Angiografia por Tomografia Computadorizada/métodos , Tecido Adiposo/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Valor Preditivo dos Testes
6.
J Thromb Thrombolysis ; 48(4): 610-618, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31359325

RESUMO

Both transcatheter aortic valve implantation (TAVI) and surgical aortic valve replacement (SAVR) have been proven to effectively correct von Willebrand Factor (vWF) pathologies, however there is limited data simultaneously comparing outcomes of both approaches. We prospectively enrolled patients with severe aortic stenosis referred for TAVI (n = 52) or SAVR (n = 48). In each case, vWF antigen (vWF:Ag), vWF activity (vWF:Ac) and activity-to-antigen (vWF:Ac/Ag) ratio were assessed at baseline, 24 h and 72 h after procedure. VWF abnormalities were defined as reduced vWF:Ac/Ag ratio (< 0.8). Bleeding events in both arms were classified according to Valve Academic Research Consortium (VARC-2) definitions. Overall, there was no difference between patients referred for TAVI and SAVR in vWF:Ac (1.62 ± 0.52 vs 1.71 ± 0.64; p = 0.593), vWF:Ag (1.99 ± 0.81 vs 2.04 ± 0.81; p = 0.942) or vWF:Ac/Ag ratio (0.84 ± 0.16 vs 0.85 ± 0.12; p = 0.950). Pathological vWF:Ac/Ag ratio was found in 20 (38%) TAVI and 15 (31%) SAVR patients (p = 0.407). Normalization of vWF:Ac/Ag ratio at day 3 after procedure was achieved in 19 (95%) TAVI and 13 (87%) SAVR patients (p = 0.439). Similar prevalence of major or life-threatening bleedings (MLTB) after TAVI and SAVR in entire groups was observed (19% vs. 23%, p = 0.652). VWF abnormalities were associated with higher incidence of MLTB in SAVR (53% vs 9%, p < 0.001), but not TAVI (15% vs. 22%, p = 0.132). Accordingly, in receiver-operating characteristic curve analysis vWF:Ac/Ag ratio < 0.8 showed significant sensitivity and specificity for predicting MLTB in SAVR group (AUC 0.735, 95% CI 0.538-0.931, p = 0.019). We proved that abnormal function of vWF is corrected successfully after both TAVI and SAVR, but vWF abnormalities are predictive of MLTB only in surgical patients.


Assuntos
Estenose da Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Hemorragia/etiologia , Valor Preditivo dos Testes , Substituição da Valva Aórtica Transcateter/efeitos adversos , Fator de von Willebrand/fisiologia , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Incidência , Masculino , Complicações Pós-Operatórias , Estudos Prospectivos , Curva ROC , Sensibilidade e Especificidade
7.
Echocardiography ; 36(6): 1132-1138, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-31012135

RESUMO

INTRODUCTION: Infective endocarditis (IE) may take different faces in patients after transcatheter aortic valve implantation (TAVI). OBJECTIVES: The primary aim of this study was to describe echocardiographic and clinical characteristics of TAVI's patients suffered from IE. METHODS: In a single-center, retrospective study we analyzed 311 consecutive patients treated with TAVI for severe aortic stenosis between 2010 and 2018. RESULTS: According to modified Duke criteria, we confirmed IE in 2.2% of the cohort, however PVE of TAVI's valve in 1.2% only; rest of the group suffered from CDRiE and IE of the mitral valve. In PVE's group vegetations were localized inside the frame with or without bioprosthesis moderate stenosis or regurgitation. Only 1 pts developed significant TAVI's bioprosthesis' paravalvular leak. We observed no native aortic anulus involvement. Mortality rate in the PVE-TAVI's group was 75% regardless of the type of treatment. CONCLUSIONS: The above findings show that IE following TAVI is a serious complication and various scenarios (also CDRiE and native valve IE) should be considered.


Assuntos
Ecocardiografia/métodos , Endocardite/diagnóstico por imagem , Complicações Pós-Operatórias/diagnóstico por imagem , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Estudos Retrospectivos
8.
Catheter Cardiovasc Interv ; 91(1): 115-123, 2018 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-28843025

RESUMO

BACKGROUND: Coronary artery disease (CAD) and degenerative aortic stenosis often coexist. However, the impact of CAD and its management on the prognosis after transcatheter aortic valve implantation (TAVI) remains uncertain. We sought to evaluate the impact of obstructive CAD, SYNTAX score (Ss), and percutaneous coronary intervention (PCI) prior to TAVI on short-term outcome. METHODS: Overall, 896 patients who underwent TAVI after heart team decision was included. Pre-procedural angiograms were analysed to calculate baseline Ss (bSs) and residual Ss (rSs). Baseline, procedural and follow-up data up to 30 days was acquired from the national POL-TAVI registry. RESULTS: Patients with obstructive CAD at baseline (n = 462, 52%) had higher mortality as compared with the remaining (8.7 vs. 5.1%, log-rank P = 0.039). Also, after correction for confounding factors obstructive CAD was identified as independent predictor of mortality (hazard ratio [HR] 1.74, 95% confidence intervals [CIs] 1.03-2.94, P = 0.037). In obstructive CAD, neither bSs (AUC 0.47, CI 0.38-0.56, P = 0.47) nor rSs (AUC 0.47, CI 0.30-0.64, P = 0.72 for those undergoing PCI and AUC 0.48, CI 0.37-0.59, P = 0.75 for the remaining) was predictive of mortality. When revascularization status was considered, patients with PCI prior to TAVI had similar outcome as those without obstructive CAD at baseline (7.7 vs. 5.1%, log-rank P = 0.23) with no negative impact on mortality (HR 1.13, CI 0.62-2.09, P = 0.69). CONCLUSIONS: In conclusion, obstructive CAD at baseline evaluation for TAVI has independent negative impact on short-term prognosis. However, neither baseline nor residual Ss values have prognostic ability in patients undergoing TAVI. Revascularization prior to TAVI seems to improve survival to levels comparable with patients without obstructive CAD at baseline.


Assuntos
Estenose da Valva Aórtica/cirurgia , Doença da Artéria Coronariana/cirurgia , Intervenção Coronária Percutânea , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Angiografia Coronária , Doença da Artéria Coronariana/complicações , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Feminino , Humanos , Masculino , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Polônia , Encaminhamento e Consulta , Sistema de Registros , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
9.
J Interv Cardiol ; 31(6): 861-869, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-30009390

RESUMO

OBJECTIVE: To compare the safety and efficacy of transcathether aortic valve-in-valve implantation (ViV-TAVI) in degenerated stentless bioprostheses with failed stented valves and degenerated native aortic valves. INTRODUCTION: Little is known about ViV-TAVI in degenerated stentless valves. METHODS: Out of 45 ViV-TAVI procedures reported in the POL-TAVI registry, 20 failed stentless valves were compared with 25 stented prostheses and propensity-matched with 45 native TAVI cases. The mean follow-up was 633 (95% confidence interval [CI], 471-795) days and Valve Academic Research Consortium-2 (VARC-2) definitions were applied. RESULTS: Patients with degenerated stentless valves were younger (65.6, CI 58-73.1 years vs 75.6, CI 72.2-78 [stented] vs 80.1, CI 78.7-81.6 y. [native], P < 0.001). Implantation was required later after surgery (11.5, CI 8-14.9 years) in the stentless cohort as compared with the stented one (6.2, CI 4.7-7.6 years, P = 0.006). ViV-TAVI in the stentless group was also associated with larger amount of contrast (211, CI 157-266 mL vs 135, CI 104-167 mL [stented] vs 132 (119-145) mL [native], P = 0.022). Using VARC-2 composite endpoints, ViV-TAVI in stentless prostheses was characterized by a lower device success (50% vs 76% in stented vs 88.9% in native TAVI, P < 0.001), but comparable early safety up to 30 days (73.7% vs 84% vs 81.8%, respectively, log-rank P = 0.667) and long-term clinical efficacy beyond 30 days (72.2% vs 72% vs 73.8%, respectively, log-rank P = 0.963). CONCLUSIONS: Despite technical challenges and a lower device success, ViV-TAVI in stentless aortic bioprostheses achieves similar safety, efficacy, and functional improvement as in stented or degenerated native valves.


Assuntos
Estenose da Valva Aórtica/cirurgia , Bioprótese/efeitos adversos , Próteses Valvulares Cardíacas/efeitos adversos , Falha de Prótese/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/cirurgia , Ecocardiografia , Feminino , Humanos , Masculino , Desenho de Prótese/efeitos adversos , Desenho de Prótese/métodos , Sistema de Registros , Stents , Análise de Sobrevida , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
11.
Postepy Kardiol Interwencyjnej ; 20(2): 139-147, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-39022713

RESUMO

Introduction: Global warming is claimed to be an important cardiovascular disease risk factor. The air pollution and ambient temperatures are believed to have a significant influence on increased morbidity and premature deaths. Aim: To point out possible causative factors for coronary angiography progression in patients presenting with chronic coronary syndrome. Material and methods: There were 66 patients (41 [62%] men and 25 [38%] women) with a median age of 71.5 (62-76) years, who underwent repeated coronary angiographies due to chronic coronary syndrome within a median time interval of 145 (96-296) days. In 18 (27%) patients coronary artery lesion progression was observed despite optimal pharmacotherapy. The demographical, clinical, and personalised epidemiological factors including air pollution particles and ambient temperature exposure were taken into account in the analysis. Results: In the multivariate logistic regression model with backward stepwise elimination method, tropical nights (p = 0.047) and mean daily temperatures (p = 0.043) were revealed as predictors of coronary lesion progression > 30%. The analysis of seasonal temperature changes showed significant differences related to minimal winter temperatures between both groups (p = 0.018). Conclusions: Coronary artery lesion progression can be related to either high values of daily temperatures or to low ambient temperature. The dichotomous characteristics of temperature exposure to atherosclerosis progression suggest a detrimental role of environmental extremities on human health.

12.
J Clin Med ; 13(20)2024 Oct 19.
Artigo em Inglês | MEDLINE | ID: mdl-39458199

RESUMO

Background/Objectives: Advanced calcific aortic stenosis, with or without coronary artery disease [CAD], may lead to severe systolic dysfunction. The aim of the study was to reveal clinical and laboratory parameters that may differentiate patients with severe aortic stenosis with and without systolic dysfunction. Methods: A retrospective, single-center study included all consecutive patients diagnosed with severe aortic stenosis with overt heart failure. Patients with hematological and neoplastic diseases were excluded. Demographic, clinical and laboratory data were analysed. Neutrophil-to-lymphocyte [NLR], monocyte-to-lymphocyte [MLR], and platelet-to-lymphocyte [PLR] ratios were calculated. The study group was divided based on left ventricular ejection fraction [LVEF]. Results: The final study population comprised 301 patients [133 males [44%]; median [Q1-3] age of 80 [75-83] years]. Co-morbidities included CAD [48.8%], arterial hypertension [75.4%], diabetes mellitus [n = 124, 41.2%], atrial fibrillation [39.2%], chronic kidney disease [60.8%]. Fifty-seven patients presented with LVEF ≤ 40% (heart failure with reduced ejection fraction (HFrEF)) and 244 with LVEF > 40%. In the multivariable analysis, N-terminal pro-B-type natriuretic peptide [NTproBNP] [p < 0.001, OR 1.000, 95%CI 1.000-1.000], baseline MLR [p < 0.020, OR 7.393, 95%CI 1.363-40.091] and female sex [p < 0.001, OR 0.308, 95%CI 0.160-0.593] were revealed as significant predictors of HFrEF. Baseline MLR weakly correlated with EuroScore II [Spearman r = 0.141, p = 0.015] and NTproBNP [r = 0.142, p = 0.014]. Cut-off values were established as 0.36 for MLR and 3927 pg/mL for NTproBNP. After excluding 147 patients with CAD, there was still a statistically significant difference in MLR between the subgroups [p = 0.024]. Conclusions: Increased values of MLR and NTproBNP together with female sex are predictive parameters for LVEF ≤ 40% in patients with severe aortic stenosis.

13.
Circ Cardiovasc Imaging ; 17(10): e016958, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-39405390

RESUMO

BACKGROUND: Plaque quantification from coronary computed tomography angiography has emerged as a valuable predictor of cardiovascular risk. Deep learning can provide automated quantification of coronary plaque from computed tomography angiography. We determined per-patient age- and sex-specific distributions of deep learning-based plaque measurements and further evaluated their risk prediction for myocardial infarction in external samples. METHODS: In this international, multicenter study of 2803 patients, a previously validated deep learning system was used to quantify coronary plaque from computed tomography angiography. Age- and sex-specific distributions of coronary plaque volume were determined from 956 patients undergoing computed tomography angiography for stable coronary artery disease from 5 cohorts. Multicenter external samples were used to evaluate associations between coronary plaque percentiles and myocardial infarction. RESULTS: Quantitative deep learning plaque volumes increased with age and were higher in male patients. In the combined external sample (n=1847), patients in the ≥75th percentile of total plaque volume (unadjusted hazard ratio, 2.65 [95% CI, 1.47-4.78]; P=0.001) were at increased risk of myocardial infarction compared with patients below the 50th percentile. Similar relationships were seen for most plaque volumes and persisted in multivariable analyses adjusting for clinical characteristics, coronary artery calcium, stenosis, and plaque volume, with adjusted hazard ratios ranging from 2.38 to 2.50 for patients in the ≥75th percentile of total plaque volume. CONCLUSIONS: Per-patient age- and sex-specific distributions for deep learning-based coronary plaque volumes are strongly predictive of myocardial infarction, with the highest risk seen in patients with coronary plaque volumes in the ≥75th percentile.


Assuntos
Angiografia por Tomografia Computadorizada , Angiografia Coronária , Doença da Artéria Coronariana , Aprendizado Profundo , Infarto do Miocárdio , Placa Aterosclerótica , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Infarto do Miocárdio/epidemiologia , Infarto do Miocárdio/etiologia , Infarto do Miocárdio/diagnóstico por imagem , Medição de Risco , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/epidemiologia , Idoso , Angiografia Coronária/métodos , Valor Preditivo dos Testes , Fatores Sexuais , Fatores de Risco , Fatores Etários , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/patologia , Prognóstico
14.
Artigo em Inglês | MEDLINE | ID: mdl-39115499

RESUMO

BACKGROUND: Aortic stenosis (AS) is characterized by calcification and fibrosis. The ability to quantify these processes simultaneously has been limited with previous imaging methods. OBJECTIVES: The purpose of this study was to evaluate the aortic valve fibrocalcific volume by computed tomography (CT) angiography in patients with AS, in particular, to assess its reproducibility, association with histology and disease severity, and ability to predict/track progression. METHODS: In 136 patients with AS, fibrocalcific volume was calculated on CT angiograms at baseline and after 1 year. CT attenuation distributions were analyzed using Gaussian-mixture-modeling to derive thresholds for tissue types enabling the quantification of calcific, noncalcific, and fibrocalcific volumes. Scan-rescan reproducibility was assessed and validation provided against histology and in an external cohort. RESULTS: Fibrocalcific volume measurements took 5.8 ± 1.0 min/scan, demonstrating good correlation with ex vivo valve weight (r = 0.51; P < 0.001) and excellent scan-rescan reproducibility (mean difference -1%, limits of agreement -4.5% to 2.8%). Baseline fibrocalcific volumes correlated with mean gradient on echocardiography in both male and female participants (rho = 0.64 and 0.69, respectively; both P < 0.001) and in the external validation cohort (n = 66, rho = 0.58; P < 0.001). The relationship was driven principally by calcific volume in men and fibrotic volume in women. After 1 year, fibrocalcific volume increased by 17% and correlated with progression in mean gradient (rho = 0.32; P = 0.003). Baseline fibrocalcific volume was the strongest predictor of subsequent mean gradient progression, with a particularly strong association in female patients (rho = 0.75; P < 0.001). CONCLUSIONS: The aortic valve fibrocalcific volume provides an anatomic assessment of AS severity that can track disease progression precisely. It correlates with disease severity and hemodynamic progression in both male and female patients.

15.
J Cardiovasc Dev Dis ; 10(5)2023 May 14.
Artigo em Inglês | MEDLINE | ID: mdl-37233183

RESUMO

Aortic stenosis is the most common form of valve disease in the Western world and a major healthcare burden. Although echocardiography remains the central modality for the diagnosis and assessment of aortic stenosis, recently, advanced cardiac imaging with cardiovascular magnetic resonance, computed tomography, and positron emission tomography have provided invaluable pathological insights that may guide the personalized management of the disease. In this review, we discuss applications of these novel non-invasive imaging modalities for establishing the diagnosis, monitoring disease progression, and eventually planning the invasive treatment of aortic stenosis.

16.
Adv Med Sci ; 68(2): 396-401, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37837798

RESUMO

PURPOSE: The normal healthy valve is devoid of inflammatory cells, however background of aortic stenosis (AS) may include inflammatory processes. Moreover, the link between hyperparathyroidism and heart failure is postulated. Simple whole blood analysis with indices is a beneficial tool in cardiovascular diseases' assessment. The purpose of the study was to evaluate correlation between parathyroid hormone (PTH) and simple blood parameters in severe AS. MATERIAL AND METHODS: The study included 62 patients with severe AS. Patients with inflammatory or autoimmune co-morbidities were excluded. Blood samples were collected, and clinical and demographic data were analyzed. RESULTS: The final study group comprised 55 patients (31 females, 56.4%; mean age 77.13 (SD 6.76)). In 23 patients (41.8%), PTH concentration was markedly increased. The study group was divided into two subgroups according to the PTH concentration. Patients from both groups did not differ significantly in terms of age and co-morbidities. PTH concentration correlated positively with monocyte-lymphocyte ratio (MLR) (p â€‹= â€‹0.008, Spearman rho 0.356) and platelet-lymphocyte ratio (PLR) (p â€‹= â€‹0.047, Spearman rho 0.269), creatinine level (p â€‹= â€‹0.001, Spearman rho 0.425) and glomerular filtration rate (GFR-MDRD) (p â€‹= â€‹0.009, Spearman rho -0.349). The multivariable logistic regression with backward analysis revealed MLR (p â€‹= â€‹0.029) and GFR (p â€‹= â€‹0.028) as independent significant predictors of abnormal PTH values. The receiver operator characteristics (ROC) curve was performed for the model of MLR and GFR-MDRD (AUC â€‹= â€‹0.777), yielding the sensitivity of 60.9% and specificity of 90.6%. CONCLUSIONS: PTH concentration correlates with monocyte-to-lymphocyte and platelet-to-lymphocyte ratios in calcified AS.


Assuntos
Estenose da Valva Aórtica , Monócitos , Feminino , Humanos , Idoso , Hormônio Paratireóideo , Linfócitos , Plaquetas , Neutrófilos , Estenose da Valva Aórtica/complicações , Estudos Retrospectivos
17.
Postepy Kardiol Interwencyjnej ; 19(3): 243-250, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37854973

RESUMO

Introduction: Coexistence of coronary artery disease (CAD) in patients with severe aortic stenosis (AS) referred for transcatheter aortic valve implantation (TAVI) raises questions regarding the safety and efficacy of TAVI in this subset of patients. Aim: To evaluate the impact of previous coronary revascularization in terms of percutaneous coronary intervention (PCI) or coronary artery bypass grafting (CABG) on clinical outcomes after TAVI. Material and methods: A total of 507 consecutive patients who underwent TAVI were divided into: non-revascularization (NR), post-PCI and post-CABG groups. The endpoints were established according to VARC-2 definitions. Results: Patients with previous coronary revascularization (36.7% of the population) were younger, more often male and their EuroSCORE II risk evaluation was significantly higher (NR 7.9% vs. post-PCI 8.0% vs. post-CABG 20.5%, p < 0.0001). Patients after PCI or CABG prior to TAVI had similar 30-day all-cause mortality rates as those without coronary revascularization at baseline (NR vs. post-PCI vs. post-CABG: 8.1% vs. 5.5% vs. 6.8%, respectively; p = 0.6). There were no differences in 12-month all-cause mortality rates between groups (NR vs. post-PCI vs. post-CABG: 15.3% vs. 14.2% vs. 16.9%, respectively; log-rank p = 0.67). In the Cox proportional-hazards regression model, acute kidney injury stage 2-3 (HR = 3.7, 95% CI: 2.14-6.33; p < 0.001) and post-TAVI stroke (HR = 3.5, 95% CI: 1.57-7.8; p = 0.002) were independently correlated with 1-year mortality. Conclusions: TAVI seems to be a safe and effective procedure for the treatment of severe AS in patients with previous coronary revascularization.

18.
J Cardiovasc Dev Dis ; 10(1)2023 Jan 05.
Artigo em Inglês | MEDLINE | ID: mdl-36661916

RESUMO

Mechanical circulatory support (MCS) allows for functional left and right heart ventricle replacement. MCS induces a systemic inflammatory reaction and prothrombotic state leading to an increased risk of thrombus formation. The extracellular vesicles (EVs) are nanoparticles released from active/injured cells characterized by prothrombotic properties. Simple inflammatory parameters from whole blood count analysis have established a clinical role in everyday practice to describe immune-inflammatory activation. We hypothesized that increased plasma concentrations of EVs might be associated with the proinflammatory and pro-thrombotic characteristics of left ventricle assist device (LVAD) and right ventricle assist device (RVAD) devices. We presented a pilot study showing the concentration of peripheral blood serum, right and left ventricle mechanical assist device extracellular concentration in relation to thrombotic complication in patients treated with a biventricular pulsatile assist device (BIVAD). The observation was based on 12 replacements of pulsatile pumps during 175 days of observation. The proinflammatory characteristics of LVAD were noted. The proinflammatory and procoagulant activation by RVAD was observed. The results may provide possible explanations for the worse results of right-sided mechanical supports observed in clinical practice.

19.
Kardiol Pol ; 81(4): 373-380, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36594529

RESUMO

BACKGROUND: The carotid artery is an alternative access route for transcatheter aortic valve implantation (TAVI), especially useful in patients unsuitable for traditional access routes including transfemoral (TF), subclavian, transapical, and aortic. AIMS: To investigate the feasibility and safety of transcarotid (TC) access for TAVI in comparison to the TF approach in a multicenter setting. METHODS: A total of 41 patients, treated between December 2014 and December 2018, were retrospectively reported to the Polish Registry of Common Carotid Artery Access for TAVI (POL-CAROTID). The median follow-up time was 619 (365-944) days, and Valve Academic Research Consortium-2 (VARC-2) definitions were applied. Clinical outcomes were compared with 41 propensity-matched TF-TAVI patients. RESULTS: The mean (standard deviation [SD]) patients' age was 78.0 (7.2) years, and 29 patients (70.7%) were men. Prohibitive iliofemoral anatomy and/or obesity (46.3%) and/or the presence of a stent graft in the abdominal aorta (31.7%) were the most common indications for TC-TAVI. Device success for TC-TAVI was comparable with the matched TF-TAVI group (90.2% vs. 95.3%, respectively, P = 0.396), and no periprocedural mortality was observed. Moreover, early safety was similar between the two groups (92.7% vs. 95.3%, respectively, log-rank P = 0.658) with only 1 case of non-disabling stroke during the first month after TC-TAVI. Consequently, no cerebrovascular events were observed in the mid-term, and the clinical efficacy of TC-TAVI corresponded well with TF-TAVI (90.2% vs. 92.7%, respectively, log-rank P = 0.716). A total of 4 (9.8%) deaths were noted in the TC-TAVI cohort in comparison to 3 (7.3%) in the TF-TAVI group. CONCLUSIONS: The results of the study indicated that the first cohort of Polish patients with implantations of second-generation transcarotid transcatheter heart valves had a similar prognosis to TF-TAVI with regard to safety and feasibility. TC access may be considered an optimal alternative for patients in whom the TF approach is precluded.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Masculino , Humanos , Idoso , Feminino , Substituição da Valva Aórtica Transcateter/efeitos adversos , Estenose da Valva Aórtica/cirurgia , Estudos Retrospectivos , Artérias Carótidas , Valva Aórtica/cirurgia , Resultado do Tratamento , Sistema de Registros
20.
Eur Heart J Cardiovasc Imaging ; 24(12): 1653-1660, 2023 11 23.
Artigo em Inglês | MEDLINE | ID: mdl-37339331

RESUMO

AIMS: Aortic stenosis is characterized by fibrosis and calcification of the valve, with a higher proportion of fibrosis observed in women. Stenotic bicuspid aortic valves progress more rapidly than tricuspid valves, which may also influence the relative composition of the valve. We aimed to investigate the influence of cusp morphology on quantitative aortic valve composition quantified from contrast-enhanced computed tomography angiography in severe aortic stenosis. METHODS AND RESULTS: Patients undergoing transcatheter aortic valve implantation with bicuspid and tricuspid valves were propensity matched 1:1 by age, sex, and comorbidities. Computed tomography angiograms were analysed using semi-automated software to quantify the fibrotic and calcific scores (volume/valve annular area) and the fibro-calcific ratio (fibrotic score/calcific score). The study population (n = 140) was elderly (76 ± 10 years, 62% male) and had a peak aortic jet velocity of 4.1 ± 0.7 m/s. Compared with those with tricuspid valves (n = 70), patients with bicuspid valves (n = 70) had higher fibrotic scores [204 (interquartile range 118-267) vs. 144 (99-208) mm3/cm2, P = 0.006] with similar calcific scores (P = 0.614). Women had greater fibrotic scores than men in bicuspid [224 (181-307) vs. 169 (109-247) mm3/cm2, P = 0.042] but not tricuspid valves (P = 0.232). Men had greater calcific scores than women in both bicuspid [203 (124-355) vs. 130 (70-182) mm3/cm2, P = 0.008] and tricuspid [177 (136-249) vs. 100 (62-150) mm3/cm2, P = 0.004] valves. Among both valve types, women had a greater fibro-calcific ratio compared with men [tricuspid 1.86 (0.94-2.56) vs. 0.86 (0.54-1.24), P = 0.001 and bicuspid 1.78 (1.21-2.90) vs. 0.74 (0.44-1.53), P = 0.001]. CONCLUSIONS: In severe aortic stenosis, bicuspid valves have proportionately more fibrosis than tricuspid valves, especially in women.


Assuntos
Estenose da Valva Aórtica , Doença da Válvula Aórtica Bicúspide , Substituição da Valva Aórtica Transcateter , Humanos , Masculino , Feminino , Idoso , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Valva Aórtica/patologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/patologia , Doença da Válvula Aórtica Bicúspide/patologia , Fibrose
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA