1.
Microsyst Nanoeng ; 9: 49, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37091826

RESUMO

Transit-time ultrasonic flowmeters (TTUFs) are among the most widely used devices for flow measurements. However, traditional TTUFs are usually based on a bulk piezoelectric transducer, which limits their application in small-diameter channels. In this paper, we developed a miniaturized TTUF based on scandium-doped aluminum nitride (ScAlN) piezoelectric micromachined ultrasonic transducers (PMUTs). The proposed TTUF contains two PMUT-based transceivers and a π-type channel. The PMUTs contain 13 × 13 square cells with dimensions of 2.8 × 2.8 mm2. To compensate for the acoustic impedance mismatch with liquid, a layer of polyurethane is added to the surface of the PMUTs as a matching layer. The PMUT-based transceivers show good transmitting sensitivity (with 0.94 MPa/V surface pressure) and receiving sensitivity (1.79 mV/kPa) at a frequency of 1 MHz in water. Moreover, the dimensions of the π-type channel are optimized to achieve a measurement sensitivity of 82 ns/(m/s) and a signal-to-noise ratio (SNR) better than 15 dB. Finally, we integrate the fabricated PMUTs into the TDC-GP30 platform. The experimental results show that the developed TTUF provides a wide range of flow measurements from 2 to 300 L/h in a channel of 4 mm diameter, which is smaller than most reported channels. The accuracy and repeatability of the TTUF are within 0.2% and 1%, respectively. The proposed TTUF shows great application potential in industrial applications such as medical and chemical applications.

2.
Microsyst Nanoeng ; 8: 116, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36389053

RESUMO

This paper reports on an aluminum nitride (AlN) piezoelectric micromachined ultrasound transducer (PMUT) array for photoacoustic (PA) imaging, where the high-order resonance modes of the PMUT are utilized to improve imaging resolution. A flexural vibration mode (FVM) PMUT is fabricated and applied in a photoacoustic imaging (PAI) system. Specifically, the microelectromechanical system (MEMS)-based PMUT is suitable for PA endoscopic imaging of blood vessels and bronchi due to its miniature size and high sensitivity. More importantly, AlN is a nontoxic material, which makes it harmless for biomedical applications. In the PAI system, the AlN PMUT array is used to detect PA signals, and the acousto-mechanical response is designed and optimized at the PMUT's fundamental resonance. In this work, we focus on the high-order resonance performance of the PMUT PAI beyond the fundamental resonance. The acoustic and electrical responses of the PMUT's high-order resonance modes are characterized and analyzed. The fundamental and three high-order resonance bandwidths are 2.2, 8.8, 18.5, and 48.2 kHz. Compared with the resolution at the fundamental resonance mode, the resolutions at third- and fourth-order resonance modes increase by 38.7% and 76.9% in a phantom experiment. The high-order resonance modes of the AlN PMUT sensor array provide higher central frequency and wider bandwidth for PA signal detection, which increase the resolution of PAI compared to the PMUT working at the fundamental resonance mode.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA