Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 96
Filtrar
1.
J Magn Reson Imaging ; 2024 Sep 18.
Artigo em Inglês | MEDLINE | ID: mdl-39291552

RESUMO

BACKGROUND: Breast cancer screening with dynamic contrast-enhanced MRI (DCE-MRI) is recommended for high-risk women but has limitations, including variable specificity and difficulty in distinguishing cancerous (CL) and high-risk benign lesions (HRBL) from average-risk benign lesions (ARBL). Complementary non-invasive imaging techniques would be useful to improve specificity. PURPOSE: To evaluate the performance of a previously-developed breast-specific diffusion-weighted MRI (DW-MRI) model (BS-RSI3C) to improve discrimination between CL, HRBL, and ARBL in an enriched screening population. STUDY TYPE: Prospective. SUBJECTS: Exactly 187 women, either with mammography screening recommending additional imaging (N = 49) or high-risk individuals undergoing routine breast MRI (N = 138), before the biopsy. FIELD STRENGTH/SEQUENCE: Multishell DW-MRI echo planar imaging sequence with a reduced field of view at 3.0 T. ASSESSMENT: A total of 72 women had at least one biopsied lesion, with 89 lesions categorized into ARBL, HRBL, CL, and combined CLs and HRBLs (CHRLs). DW-MRI data were processed to produce apparent diffusion coefficient (ADC) maps, and estimate signal contributions (C1, C2, and C3-restricted, hindered, and free diffusion, respectively) from the BS-RSI3C model. Lesion regions of interest (ROIs) were delineated on DW images based on suspicious DCE-MRI findings by two radiologists; control ROIs were drawn in the contralateral breast. STATISTICAL TESTS: One-way ANOVA and two-sided t-tests were used to assess differences in signal contributions and ADC values among groups. P-values were adjusted using the Bonferroni method for multiple testing, P = 0.05 was used for the significance level. Receiver operating characteristics (ROC) curves and intra-class correlations (ICC) were also evaluated. RESULTS: C1, √C1C2, and log C 1 C 2 C 3 $$ \log \left(\frac{{\mathrm{C}}_1{\mathrm{C}}_2}{{\mathrm{C}}_3}\right) $$ were significantly different in HRBLs compared with ARBLs (P-values < 0.05). The log C 1 C 2 C 3 $$ \log \left(\frac{{\mathrm{C}}_1{\mathrm{C}}_2}{{\mathrm{C}}_3}\right) $$ had the highest AUC (0.821) in differentiating CHRLs from ARBLs, performing better than ADC (0.696), especially in non-mass enhancement (0.776 vs. 0.517). DATA CONCLUSION: This study demonstrated the BS-RSI3C could differentiate HRBLs from ARBLs in a screening population, and separate CHRLs from ARBLs better than ADC. TECHNICAL EFFICACY STAGE: 2.

2.
BJOG ; 131(3): 267-277, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37522240

RESUMO

OBJECTIVE: To identify vaginal morphology and position factors associated with prolapse recurrence following vaginal surgery. DESIGN: Secondary analysis of magnetic resonance images (MRI) of the Defining Mechanisms of Anterior Vaginal Wall Descent cross-sectional study. SETTING: Eight clinical sites in the US Pelvic Floor Disorders Network. POPULATION OR SAMPLE: Women who underwent vaginal mesh hysteropexy (hysteropexy) with sacrospinous fixation or vaginal hysterectomy with uterosacral ligament suspension (hysterectomy) for uterovaginal prolapse between April 2013 and February 2015. METHODS: The MRI (rest, strain) obtained 30-42 months after surgery, or earlier for participants with recurrence who desired reoperation before 30 months, were analysed. MRI-based prolapse recurrence was defined as prolapse beyond the hymen at strain on MRI. Vaginal segmentations (at rest) were used to create three-dimensional models placed in a morphometry algorithm to quantify and compare vaginal morphology (angulation, dimensions) and position. MAIN OUTCOME MEASURES: Vaginal angulation (upper, lower and upper-lower vaginal angles in the sagittal and coronal plane), dimensions (length, maximum transverse width, surface area, volume) and position (apex, mid-vagina) at rest. RESULTS: Of the 82 women analysed, 12/41 (29%) in the hysteropexy group and 22/41 (54%) in the hysterectomy group had prolapse recurrence. After hysteropexy, women with recurrence had a more laterally deviated upper vagina (p = 0.02) at rest than women with successful surgery. After hysterectomy, women with recurrence had a more inferiorly (lower) positioned vaginal apex (p = 0.01) and mid-vagina (p = 0.01) at rest than women with successful surgery. CONCLUSIONS: Vaginal angulation and position were associated with prolapse recurrence and suggestive of vaginal support mechanisms related to surgical technique and potential unaddressed anatomical defects. Future prospective studies in women before and after prolapse surgery may distinguish these two factors.


Assuntos
Prolapso de Órgão Pélvico , Prolapso Uterino , Feminino , Humanos , Estudos Prospectivos , Estudos Transversais , Resultado do Tratamento , Procedimentos Cirúrgicos em Ginecologia/métodos , Vagina/diagnóstico por imagem , Vagina/cirurgia , Histerectomia Vaginal , Prolapso Uterino/cirurgia , Prolapso de Órgão Pélvico/cirurgia
3.
J Behav Med ; 47(4): 692-706, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38671287

RESUMO

Children in rural communities consume more energy-dense foods relative to their urban peers. Identifying effective interventions for improving energy intake patterns are needed to address these geographic disparities. The primary aim of this study was to harness the benefits of physical activity on children's executive functioning to see if these improvements lead to acute changes in eating behaviors. In a randomized crossover design, 91 preadolescent (8-10y; M age = 9.48 ± 0.85; 50.5% female; 85.7% White, 9.9% Multiracial, 9.9% Hispanic) children (86% rural) completed a 20-minute physical activity condition (moderate intensity walking) and time-matched sedentary condition (reading and/or coloring) ~ 14 days apart. Immediately following each condition, participants completed a behavioral inhibition task and then eating behaviors (total energy intake, relative energy intake, snack intake) were measured during a multi-array buffet test meal. After adjusting for period and order effects, body fat (measured via DXA), and depressive symptoms, participants experienced significant small improvements in their behavioral inhibition following the physical activity versus sedentary condition (p = 0.04, Hedge's g = 0.198). Eating behaviors did not vary by condition, nor did improvements in behavioral inhibition function as a mediator (ps > 0.09). Thus, in preadolescent children, small improvements in behavioral inhibition from physical activity do not produce acute improvements in energy intake. Additional research is needed to clarify whether the duration and/or intensity of physical activity sessions would produce different results in this age group, and whether intervention approaches and corresponding mechanisms of change vary by individual factors, like age and degree of food cue responsivity.


Assuntos
Ingestão de Energia , Exercício Físico , Comportamento Alimentar , Inibição Psicológica , Humanos , Feminino , Masculino , Criança , Comportamento Alimentar/psicologia , Exercício Físico/psicologia , Estudos Cross-Over , Comportamento Infantil/psicologia , Função Executiva , Comportamento Sedentário
4.
J Appl Clin Med Phys ; : e14514, 2024 Oct 07.
Artigo em Inglês | MEDLINE | ID: mdl-39374162

RESUMO

PURPOSE: The purpose of the present study is to develop a calibration method to account for differences in echo times (TE) and facilitate the use of restriction spectrum imaging restriction score (RSIrs) as a quantitative biomarker for the detection of clinically significant prostate cancer (csPCa). METHODS: This study included 197 consecutive patients who underwent MRI and biopsy examination; 97 were diagnosed with csPCa (grade group ≥ 2). RSI data were acquired three times during the same session: twice at minimum TE ~75 ms and once at TE = 90 ms (TEmin1, TEmin2, and TE90, respectively). A linear regression model was determined to match the C-maps of TE90 to the reference C-maps of TEmin1 within the interval ranging from 95th to 99th percentile of signal intensity within the prostate. RSIrs comparisons were made at the 98th percentile within each patient's prostate. We compared RSIrs from calibrated TE90 (RSIrsTE90corr) and uncorrected TE90 (RSIrsTE90) to RSIrs from reference TEmin1 (RSIrsTEmin1) and repeated TEmin2 (RSIrsTEmin2). Calibration performance was evaluated with sensitivity, specificity and area under the ROC curve (AUC). RESULTS: Scaling factors for C1, C2, C3, and C4 were estimated as 1.68, 1.33, 1.02, and 1.13, respectively. In non-csPCa cases, the 98th percentile of RSIrsTEmin2 and RSIrsTEmin1 differed by 0.27 ± 0.86SI (mean ± standard deviation), whereas RSIrsTE90 differed from RSIrsTEmin1 by 1.82 ± 1.20SI. After calibration, this bias was reduced to -0.51 ± 1.21SI, representing a 72% reduction in absolute error. For patients with csPCa, the difference was 0.54 ± 1.98SI between RSIrsTEmin2 and RSIrsTEmin1 and 2.28 ± 2.06SI between RSIrsTE90 and RSIrsTEmin1. After calibration, the mean difference decreased to -1.03SI, a 55% reduction in absolute error. At the Youden index for patient-level classification of csPCa (8.94SI), RSIrsTEmin1 has a sensitivity of 66% and a specificity of 72%. CONCLUSIONS: The proposed linear calibration method produces similar quantitative biomarker values for acquisitions with different TE, reducing TE-induced error by 72% and 55% for non-csPCa and csPCa, respectively.

5.
J Strength Cond Res ; 38(4): 671-680, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38513175

RESUMO

ABSTRACT: Mongold, SJ, Ricci, AW, Hahn, ME, and Callahan, DM. Skeletal muscle compliance and echogenicity in resistance-trained and nontrained women. J Strength Cond Res 38(4): 671-680, 2024-Noninvasive assessment of muscle mechanical properties in clinical and performance settings tends to rely on manual palpation and emphasizes examination of musculotendinous stiffness. However, measurement standards are highly subjective. The purpose of the study was to compare musculotendinous stiffness in adult women with varying resistance training history while exploring the use of multiple tissue compliance measures. We identified relationships between tissue stiffness and morphology, and tested the hypothesis that combining objective measures of morphology and stiffness would better predict indices of contractile performance. Resistance-trained (RT) women (n = 11) and nontrained (NT) women (n = 10) participated in the study. Muscle echogenicity and morphology were measured using B-mode ultrasonography (US). Vastus lateralis (VL) and patellar tendon (PT) stiffness were measured using digital palpation and US across submaximal isometric contractions. Muscle function was evaluated during maximal voluntary isometric contraction (MVIC) of the knee extensors (KEs). Resistance trained had significantly greater PT stiffness and reduced echogenicity (p < 0.01). Resistance trained also had greater strength per body mass (p < 0.05). Muscle echogenicity was strongly associated with strength and rate of torque development (RTD). Patellar tendon passive stiffness was associated with RTD normalized to MVIC (RTDrel; r = 0.44, p < 0.05). Patellar tendon stiffness was greater in RT young women. No predictive models of muscle function incorporated both stiffness and echogenicity. Because RTDrel is a clinically relevant measure of rehabilitation in athletes and can be predicted by digital palpation, this might represent a practical and objective measure in settings where RTD may not be easy to measure directly.


Assuntos
Articulação do Joelho , Músculo Esquelético , Adulto , Humanos , Feminino , Músculo Esquelético/diagnóstico por imagem , Músculo Esquelético/fisiologia , Articulação do Joelho/fisiologia , Contração Muscular/fisiologia , Músculo Quadríceps/fisiologia , Contração Isométrica/fisiologia , Ultrassonografia , Força Muscular/fisiologia , Torque
6.
Sensors (Basel) ; 22(19)2022 Sep 20.
Artigo em Inglês | MEDLINE | ID: mdl-36236228

RESUMO

Zero-velocity assumption has been used for estimation of foot trajectory and stride length during running from the data of foot-mounted inertial measurement units (IMUs). Although the assumption provides a reasonable initialization for foot trajectory and stride length estimation, the other source of errors related to the IMU's orientation still remains. The purpose of this study was to develop an improved foot trajectory and stride length estimation method for the level ground running based on the displacement of the foot. Seventy-nine runners performed running trials at 5 different paces and their running motions were captured using a motion capture system. The accelerations and angular velocities of left and right feet were measured with two IMUs mounted on the dorsum of each foot. In this study, foot trajectory and stride length were estimated using zero-velocity assumption with IMU data, and the orientation of IMU was estimated to calculate the mediolateral and vertical distance of the foot between two consecutive midstance events. Calculated foot trajectory and stride length were compared with motion capture data. The results show that the method used in this study can provide accurate estimation of foot trajectory and stride length for level ground running across a range of running speeds.


Assuntos
, Corrida , Aceleração , Fenômenos Biomecânicos , Marcha , Movimento (Física) , Reflexo de Sobressalto , Transtornos Somatoformes , Tronco
7.
Sensors (Basel) ; 22(9)2022 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-35591141

RESUMO

The development of lightweight portable sensors and algorithms for the identification of gait events at steady-state running speeds can be translated into the real-world environment. However, the output of these algorithms needs to be validated. The purpose of this study was to validate the identification of running gait events using data from Inertial Measurement Units (IMUs) in a semi-uncontrolled environment. Fifteen healthy runners were recruited for this study, with varied running experience and age. Force-sensing insoles measured normal foot-shoe forces and provided a standard for identification of gait events. Three IMUs were mounted to the participant, two bilaterally on the dorsal aspect of the foot and one clipped to the back of each participant's waistband, approximating their sacrum. The identification of gait events from the foot-mounted IMU was more accurate than from the sacral-mounted IMU. At running speeds <3.57 m s−1, the sacral-mounted IMU identified contact duration as well as the foot-mounted IMU. However, at speeds >3.57 m s−1, the sacral-mounted IMU overestimated foot contact duration. This study demonstrates that at controlled paces over level ground, we can identify gait events and measure contact time across a range of running skill levels.


Assuntos
Corrida , Algoritmos , Fenômenos Biomecânicos , , Marcha , Humanos
8.
J Strength Cond Res ; 36(2): 386-391, 2022 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-31868814

RESUMO

ABSTRACT: Burnsed-Torres, ML, Wichmann, TK, Clayton, ZS, and Hahn, ME. Comparison of the Gauntlet test with standard laboratory measures of aerobic fitness. J Strength Cond Res 36(2): 386-391, 2022-The purpose of this study was to validate whether the Gauntlet test (GT) can accurately estimate individual aerobic endurance performance compared with standard laboratory-based physiological tests. The GT required athletes to complete 5 maximal effort running stages, with a 1-minute break between each stage, with the goal of achieving the best overall time. Eighteen men (n = 9) and women (n = 9) (age, 23.5 ± 4.13 years; body mass index, 23.1 ± 7.62 kg·m-2; 5k time, 22 ± 7 minutes; 10k time, 47 ± 15 minutes; V̇o2max, 52.3 ± 8 ml·kg-1·min-1) completed a lactate threshold test and V̇o2max test (laboratory measures). Four to 14 days later, subjects completed the GT on an outdoor track. Blood lactate (bLa), V̇o2max, and heart rate (HR) were recorded during the laboratory session. Blood lactate, HR, stage completion time, and overall completion time were recorded during the GT. Linear regression correlation analyses revealed a significant inverse association between V̇o2max (mL·kg-1·min-1) and GT completion time (r = -0.88, P < 0.0001). In addition, there were significant correlations between V̇o2max maximum HR and GT maximum HR (r = 0.89, P < 0.0001) and V̇o2max 3-minute post bLa and GT 3-minute post bLa (r = 0.63, P = 0.0029). Sex-specific analysis showed significant inverse associations between female and male GT completion time and V̇o2max (r = -0.70, P = 0.0352; r = -0.94, P < 0.0002). Bland-Altman plots were used to evaluate concordance between GT completion time, V̇o2max, maximum HR, and 3-minute post bLa. Results suggest the GT is a valid assessment to accurately estimate aerobic endurance performance similar to standard laboratory methods.


Assuntos
Laboratórios , Corrida , Adulto , Exercício Físico , Teste de Esforço , Feminino , Frequência Cardíaca , Humanos , Masculino , Consumo de Oxigênio , Adulto Jovem
9.
J Magn Reson Imaging ; 54(3): 975-984, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-33786915

RESUMO

BACKGROUND: Diffusion magnetic resonance imaging (MRI) is integral to detection of prostate cancer (PCa), but conventional apparent diffusion coefficient (ADC) cannot capture the complexity of prostate tissues and tends to yield noisy images that do not distinctly highlight cancer. A four-compartment restriction spectrum imaging (RSI4 ) model was recently found to optimally characterize pelvic diffusion signals, and the model coefficient for the slowest diffusion compartment, RSI4 -C1 , yielded greatest tumor conspicuity. PURPOSE: To evaluate the slowest diffusion compartment of a four-compartment spectrum imaging model (RSI4 -C1 ) as a quantitative voxel-level classifier of PCa. STUDY TYPE: Retrospective. SUBJECTS: Forty-six men who underwent an extended MRI acquisition protocol for suspected PCa. Twenty-three men had benign prostates, and the other 23 men had PCa. FIELD STRENGTH/SEQUENCE: A 3 T, multishell diffusion-weighted and axial T2-weighted sequences. ASSESSMENT: High-confidence cancer voxels were delineated by expert consensus, using imaging data and biopsy results. The entire prostate was considered benign in patients with no detectable cancer. Diffusion images were used to calculate RSI4 -C1 and conventional ADC. Classifier images were also generated. STATISTICAL TESTS: Voxel-level discrimination of PCa from benign prostate tissue was assessed via receiver operating characteristic (ROC) curves generated by bootstrapping with patient-level case resampling. RSI4 -C1 was compared to conventional ADC for two metrics: area under the ROC curve (AUC) and false-positive rate for a sensitivity of 90% (FPR90 ). Statistical significance was assessed using bootstrap difference with two-sided α = 0.05. RESULTS: RSI4 -C1 outperformed conventional ADC, with greater AUC (mean 0.977 [95% CI: 0.951-0.991] vs. 0.922 [0.878-0.948]) and lower FPR90 (0.032 [0.009-0.082] vs. 0.201 [0.132-0.290]). These improvements were statistically significant (P < 0.05). DATA CONCLUSION: RSI4 -C1 yielded a quantitative, voxel-level classifier of PCa that was superior to conventional ADC. RSI classifier images with a low false-positive rate might improve PCa detection and facilitate clinical applications like targeted biopsy and treatment planning. EVIDENCE LEVEL: 3 TECHNICAL EFFICACY: Stage 2.


Assuntos
Neoplasias da Próstata , Imagem de Difusão por Ressonância Magnética , Humanos , Imageamento por Ressonância Magnética , Espectroscopia de Ressonância Magnética , Masculino , Neoplasias da Próstata/diagnóstico por imagem , Curva ROC , Estudos Retrospectivos
10.
J Magn Reson Imaging ; 53(2): 628-639, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33131186

RESUMO

BACKGROUND: Multicompartmental modeling outperforms conventional diffusion-weighted imaging (DWI) in the assessment of prostate cancer. Optimized multicompartmental models could further improve the detection and characterization of prostate cancer. PURPOSE: To optimize multicompartmental signal models and apply them to study diffusion in normal and cancerous prostate tissue in vivo. STUDY TYPE: Retrospective. SUBJECTS: Forty-six patients who underwent MRI examination for suspected prostate cancer; 23 had prostate cancer and 23 had no detectable cancer. FIELD STRENGTH/SEQUENCE: 3T multishell diffusion-weighted sequence. ASSESSMENT: Multicompartmental models with 2-5 tissue compartments were fit to DWI data from the prostate to determine optimal compartmental apparent diffusion coefficients (ADCs). These ADCs were used to compute signal contributions from the different compartments. The Bayesian Information Criterion (BIC) and model-fitting residuals were calculated to quantify model complexity and goodness-of-fit. Tumor contrast-to-noise ratio (CNR) and tumor-to-background signal intensity ratio (SIR) were computed for conventional DWI and multicompartmental signal-contribution maps. STATISTICAL TESTS: Analysis of variance (ANOVA) and two-sample t-tests (α = 0.05) were used to compare fitting residuals between prostate regions and between multicompartmental models. T-tests (α = 0.05) were also used to assess differences in compartmental signal-fraction between tissue types and CNR/SIR between conventional DWI and multicompartmental models. RESULTS: The lowest BIC was observed from the 4-compartment model, with optimal ADCs of 5.2e-4, 1.9e-3, 3.0e-3, and >3.0e-2 mm2 /sec. Fitting residuals from multicompartmental models were significantly lower than from conventional ADC mapping (P < 0.05). Residuals were lowest in the peripheral zone and highest in tumors. Tumor tissue showed the largest reduction in fitting residual by increasing model order. Tumors had a greater proportion of signal from compartment 1 than normal tissue (P < 0.05). Tumor CNR and SIR were greater on compartment-1 signal maps than conventional DWI (P < 0.05) and increased with model order. DATA CONCLUSION: The 4-compartment signal model best described diffusion in the prostate. Compartmental signal contributions revealed by this model may improve assessment of prostate cancer. Level of Evidence 3 Technical Efficacy Stage 3 J. MAGN. RESON. IMAGING 2021;53:628-639.


Assuntos
Neoplasias da Próstata , Teorema de Bayes , Imagem de Difusão por Ressonância Magnética , Humanos , Masculino , Neoplasias da Próstata/diagnóstico por imagem , Reprodutibilidade dos Testes , Estudos Retrospectivos
11.
J Biomech Eng ; 143(12)2021 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-34382638

RESUMO

INTRODUCTION: Simulations based on computational musculoskeletal models are powerful tools for evaluating the effects of potential biomechanical interventions, such as implementing a novel prosthesis. However, the utility of simulations to evaluate the effects of varied prosthesis design parameters on gait mechanics has not been fully realized due to the lack of a readily-available limb loss-specific gait model and methods for efficiently modeling the energy storage and return dynamics of passive foot prostheses. The purpose of this study was to develop and validate a forward simulation-capable gait model with lower-limb loss and a semi-active variable-stiffness foot (VSF) prosthesis. METHODS: A seven-segment 28-DoF gait model was developed and forward kinematics simulations, in which experimentally observed joint kinematics were applied and the resulting contact forces under the prosthesis evolved accordingly, were computed for four subjects with unilateral below-knee amputation walking with a VSF. RESULTS: Model-predicted resultant ground reaction force (GRFR) matched well under trial-specific optimized parameter conditions (mean R2: 0.97, RMSE: 7.7% body weight (BW)) and unoptimized (subject-specific, but not trial-specific) parameter conditions (mean R2: 0.93, RMSE: 12% BW). Simulated anterior-posterior center of pressure demonstrated a mean R2 = 0.64 and RMSE = 14% foot length. Simulated kinematics remained consistent with input data (0.23 deg RMSE, R2 > 0.99) for all conditions. CONCLUSIONS: These methods may be useful for simulating gait among individuals with lower-limb loss and predicting GRFR arising from gait with novel VSF prostheses. Such data are useful to optimize prosthesis design parameters on a user-specific basis.


Assuntos
Membros Artificiais , Amputação Cirúrgica , Fenômenos Biomecânicos , , Marcha , Humanos , Articulação do Joelho , Desenho de Prótese , Caminhada
12.
J Biomech Eng ; 143(7)2021 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-33704375

RESUMO

Passive energy storage and return (ESR) feet are current performance standard in lower limb prostheses. A recently developed semi-active variable-stiffness foot (VSF) prosthesis balances the simplicity of a passive ESR device with the adaptability of a powered design. The purpose of this study was to model and simulate the ESR properties of the VSF prosthesis. The ESR properties of the VSF were modeled as a lumped parameter overhung beam. The overhung length is variable, allowing the model to exhibit variable ESR stiffness. Foot-ground contact was modeled using sphere-to-plane contact models. Contact parameters were optimized to represent the geometry and dynamics of the VSF and its foam base. Static compression tests and gait were simulated. Simulation outcomes were compared to corresponding experimental data. Stiffness of the model matched that of the physical VSF (R2: 0.98, root-mean-squared error (RMSE): 1.37 N/mm). Model-predicted resultant ground reaction force (GRFR) matched well under optimized parameter conditions (R2: 0.98, RMSE: 5.3% body weight,) and unoptimized parameter conditions (R2: 0.90, mean RMSE: 13% body weight). Anterior-posterior center of pressure matched well with R2 > 0.94 and RMSE < 9.5% foot length in all conditions. The ESR properties of the VSF were accurately simulated under benchtop testing and dynamic gait conditions. These methods may be useful for predicting GRFR arising from gait with novel prostheses. Such data are useful to optimize prosthesis design parameters on a user-specific basis.


Assuntos
Marcha
13.
Radiology ; 296(1): 76-84, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32315265

RESUMO

Background Prostate MRI is used widely in clinical care for guiding tissue sampling, active surveillance, and staging. The Prostate Imaging Reporting and Data System (PI-RADS) helps provide a standardized probabilistic approach for identifying clinically significant prostate cancer. Despite widespread use, the variability in performance of prostate MRI across practices remains unknown. Purpose To estimate the positive predictive value (PPV) of PI-RADS for the detection of high-grade prostate cancer across imaging centers. Materials and Methods This retrospective cross-sectional study was compliant with the HIPAA. Twenty-six centers with members in the Society of Abdominal Radiology Prostate Cancer Disease-focused Panel submitted data from men with suspected or biopsy-proven untreated prostate cancer. MRI scans were obtained between January 2015 and April 2018. This was followed with targeted biopsy. Only men with at least one MRI lesion assigned a PI-RADS score of 2-5 were included. Outcome was prostate cancer with Gleason score (GS) greater than or equal to 3+4 (International Society of Urological Pathology grade group ≥2). A mixed-model logistic regression with institution and individuals as random effects was used to estimate overall PPVs. The variability of observed PPV of PI-RADS across imaging centers was described by using the median and interquartile range. Results The authors evaluated 3449 men (mean age, 65 years ± 8 [standard deviation]) with 5082 lesions. Biopsy results showed 1698 cancers with GS greater than or equal to 3+4 (International Society of Urological Pathology grade group ≥2) in 2082 men. Across all centers, the estimated PPV was 35% (95% confidence interval [CI]: 27%, 43%) for a PI-RADS score greater than or equal to 3 and 49% (95% CI: 40%, 58%) for a PI-RADS score greater than or equal to 4. The interquartile ranges of PPV at these same PI-RADS score thresholds were 27%-44% and 27%-48%, respectively. Conclusion The positive predictive value of the Prostate Imaging and Reporting Data System was low and varied widely across centers. © RSNA, 2020 Online supplemental material is available for this article. See also the editorial by Milot in this issue.


Assuntos
Imageamento por Ressonância Magnética/métodos , Neoplasias da Próstata/diagnóstico por imagem , Sistemas de Informação em Radiologia , Idoso , Estudos Transversais , Humanos , Masculino , Valor Preditivo dos Testes , Próstata/diagnóstico por imagem , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sociedades Médicas
14.
J Ultrasound Med ; 39(1): 127-137, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31281992

RESUMO

OBJECTIVES: To assess the visualization rate and size of the frontal horns (FHs) and cavum septi pellucidi (CSP) in healthy fetuses throughout pregnancy. METHODS: After Institutional Review Board approval, 522 consecutive uncomplicated singleton pregnancies between 15 and 39 gestational weeks were enrolled in the study. Ultrasound measurements of the anterior horn width (AHW), center from the horn distance (CFHD), distance from the FHs to the CSP, and CSP width were retrospectively performed using axial transventricular or transcerebellar planes. Available maternal body mass indices were recorded. RESULTS: At least 1 FH was seen in 78% of the cases. The mean AHW decreased over the second trimester and plateaued in the third trimester. The CFHD plateaued in the second trimester and increased in the third trimester. Downside FHs were generally larger than upside FHs. More FHs were measured in transventricular (69%) than transcerebellar (31%) planes. Frontal horns were seen with high, low, and no confidence in 57%, 21%, and 22% of cases, respectively. No-confidence rates were 17% in the second trimester and 42% in the third trimester. The CSP was not visualized in 4% of cases; 15 of 19 cases of a nonvisualized CSP were scanned between 18 and 37 weeks. Mean body mass indices ± SDs were 27.6 ± 6.7 kg/m2 for the patients in cases of a visualized CSP and 32.4 ± 9.1 kg/m2 for the patients in cases of a nonvisualized CSP. CONCLUSIONS: Normative data for the fetal FH and CSP width were established. Frontal horns are more frequently seen on transventricular views and are difficult to confidently assess in the late third trimester. This study challenges previously reported data that the CSP is seen in 100% of cases from 18 to 37 weeks.


Assuntos
Segundo Trimestre da Gravidez , Terceiro Trimestre da Gravidez , Septo Pelúcido/anatomia & histologia , Septo Pelúcido/embriologia , Ultrassonografia Pré-Natal/métodos , Adulto , Feminino , Humanos , Gravidez , Valores de Referência , Estudos Retrospectivos
15.
J Sports Sci ; 37(23): 2702-2710, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31608832

RESUMO

The intrinsic foot musculature (IFM) supports the arches of the foot and controls metatarsophalangeal joint (MTPJ) motion. Stronger IFM can increase the effective foot length, potentially altering lower-extremity gearing similar to that of using carbon-fibre-plated footwear. The purpose of this study was to investigate if strengthening of the IFM can alter gait mechanics and improve running economy. Eleven participants were randomly assigned into an experimental group and nine into a control group. The experimental group performed IFM strengthening exercises for ten weeks. Toe-flexor strength, gait mechanics, and running economy were assessed at baseline, five weeks, and ten weeks; using a custom strength testing apparatus, motion capture and force-instrumented treadmill, and indirect calorimetry. Toe-flexor strength increased in the experimental group (p = .006); however, MTPJ and ankle mechanics and running economy did not change. The dearth of changes in mechanics may be due to a lack of mechanical advantage of the IFM, runners staying within their preferred movement path, a need for MTPJ dorsiflexion to facilitate the windlass mechanism, or the primary function of the IFM being to support the longitudinal arch of the foot as opposed to modulating MTPJ mechanics.


Assuntos
Tornozelo/fisiologia , Marcha/fisiologia , Articulação Metatarsofalângica/fisiologia , Força Muscular/fisiologia , Músculo Esquelético/fisiologia , Corrida/fisiologia , Dedos do Pé/fisiologia , Adulto , Fenômenos Biomecânicos , Feminino , Humanos , Masculino , Adulto Jovem
16.
Exp Brain Res ; 235(9): 2829-2841, 2017 09.
Artigo em Inglês | MEDLINE | ID: mdl-28647814

RESUMO

Very little is known about the effects of specific practice on motor learning of predictive balance control during novel bipedal gait. This information could provide an insight into how the direction and magnitude of predictive errors during acquisition of a novel gait task influence transfer of balance control, as well as yield a practice protocol for the restoration of balance for those with locomotor impairments. This study examined the effect of a variable practice paradigm on transfer of a novel asymmetric gait pattern in able-bodied individuals. Using a split-belt treadmill, one limb was driven at a constant velocity (constant limb) and the other underwent specific changes in velocity (variable limb) during practice according to one of three prescribed practice paradigms: serial, where the variable limb velocity increased linearly; random blocked, where variable limb underwent random belt velocity changes every 20 strides; and random practice, where the variable limb underwent random step-to-step changes in velocity. Random practice showed the highest balance control variability during acquisition compared to serial and random blocked practice which demonstrated the best transfer of balance control on one transfer test. Both random and random blocked practices showed significantly less balance control variability during a second transfer test compared to serial practice. These results indicate that random blocked practice may be best for generalizability of balance control while learning a novel gait, perhaps, indicating that individuals who underwent this practice paradigm were able to find the most optimal balance control solution during practice.


Assuntos
Marcha/fisiologia , Extremidade Inferior/fisiologia , Equilíbrio Postural/fisiologia , Prática Psicológica , Transferência de Experiência/fisiologia , Adolescente , Adulto , Feminino , Humanos , Masculino , Adulto Jovem
17.
Arch Phys Med Rehabil ; 98(6): 1180-1186, 2017 06.
Artigo em Inglês | MEDLINE | ID: mdl-28057517

RESUMO

OBJECTIVE: To investigate whether lower extremity muscle activation patterns differ in the strides leading to locomotive state transitions in the involved limb of individuals with transtibial amputation. It is hypothesized that all transitions elicit activation differences between strides as the subjects move toward the transition event. DESIGN: Single-sample, observational study. SETTING: University research center. PARTICIPANTS: Volunteer sample of persons with unilateral transtibial amputation (N=9; mean age, 48.8±12.1y; mean height, 1.74±0.09m; mean weight, 86.1±24.7kg) were recruited by posting flyers in local prosthetics clinics. INTERVENTIONS: Not applicable. MAIN OUTCOME MEASURES: Surface electromyography was used to measure muscle activation from 7 muscles of the involved limb. Subjects walked across 8 different terrain conditions transitioning from level-ground to ramp/stair locomotion and vice versa. Statistical Parametric Mapping analysis of variance (α<.05) was used to assess muscle activation differences in the 3 pretransition gait cycles as subjects moved toward the terrain change. RESULTS: No muscle activation changes were observed in ramp transitions. All stair transitions elicited a myoelectric difference in at least 2 muscles. The transition from stair descent to level ground elicited change in the greatest number of muscles. Tibialis anterior activation was unchanged in all transitions. CONCLUSIONS: Muscle activation differences were observed in the involved limb of individuals with transtibial amputation during stair transitions, suggesting that those patterns may be successfully used in transition detection algorithms. It remains unknown whether ramp transitions can be successfully identified pretransition using electromyography.


Assuntos
Amputação Cirúrgica/reabilitação , Marcha/fisiologia , Locomoção/fisiologia , Músculo Esquelético/fisiologia , Caminhada/fisiologia , Adulto , Membros Artificiais , Fenômenos Biomecânicos , Eletromiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Modalidades de Fisioterapia
18.
Laterality ; 22(2): 219-232, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26947117

RESUMO

Unilateral hand contractions increase activation in the motor cortex of the contralateral hemisphere, providing a means to alter the relative degree of activation in the right hemisphere versus the left hemisphere through spreading activation. Prior research reported enhanced verbal creativity as measured by performance on remote associate problems in Hebrew from left-hand contractions (right-hemisphere activation). We sought to extend the previous findings to English problems and to homograph interpretation. In Experiment 1, unilateral hand contractions in fact altered performance on the English remote associates, but in the direction of improved performance following right-hand contractions and left-hemisphere activation. In Experiment 2, the probability of retrieving atypical interpretations of homographs with multiple meanings was least likely for left-hemisphere dominant strong right handers, but the hand contraction manipulation had no effect.


Assuntos
Encéfalo/fisiologia , Lateralidade Funcional/fisiologia , Mãos/fisiologia , Atividade Motora/fisiologia , Contração Muscular/fisiologia , Semântica , Criatividade , Feminino , Humanos , Masculino , Testes Neuropsicológicos , Fatores de Tempo
19.
J Appl Biomech ; 32(4): 388-93, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-27046933

RESUMO

Gait termination can be challenging for balance-impaired populations, including lower limb amputees. As powered prosthetic ankle devices come to market, it is important to better understand gait termination timing in an unplanned situation. Timing patterns were examined in unplanned gait termination to determine a threshold for being able to terminate gait in 1 step. Time to terminate gait (TTG) was also examined, using both final heel strike and center of mass (COM) acceleration metrics. Fourteen able-bodied subjects walked over ground and terminated gait in response to a randomly-timed auditory stimulus. A lumbar-mounted accelerometer and footswitches were used to assess timing of gait termination. Subjects were able to terminate gait in 1 step if the stimulus occurred at or before 19.8% of gait cycle. Later stimulus resulted in a 2-step stop pattern. The TTG using COM acceleration was greater than when using heel strike data. Motion of the COM was not fully arrested until 162 ± 38% of gait cycle. The stabilization phase between heel strike and COM motion arrest was greater for 1-step stops (1.41 ± 0.42 s) than 2-step stops (0.96 ± 0.33 s). These findings indicate gait termination timing should be calculated using COM motion, including the stabilization phase post heel strike.


Assuntos
Desaceleração , Marcha/fisiologia , Extremidade Inferior/fisiologia , Acelerometria/instrumentação , Estimulação Acústica , Adulto , Fenômenos Biomecânicos , Feminino , Voluntários Saudáveis , Humanos , Masculino , Equilíbrio Postural/fisiologia
20.
J Appl Biomech ; 32(3): 233-40, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26671831

RESUMO

Lower limb amputation has been associated with secondary impairments such as knee osteoarthritis in the uninvolved limb. Greater knee loading in the frontal plane has been related to severity and rate of progression in knee osteoarthritis. Reduced push-off work from the involved limb can increase uninvolved limb knee loading. However, little is known about specific effects that prosthetic foot damping may have on uninvolved limb loading. We hypothesized that uninvolved limb peak knee internal abduction moment (IAM) and loading rates would be greater when using a high-damping foot compared with a low-damping foot, across walking speeds. Eight healthy, young subjects walked in a prosthesis simulator boot using the experimental feet. Greater uninvolved limb first peak IAM (+16% in fast speed, P = .002; +11% in slow speed, P = .001) and loading rates (+11% in fast speed, P = .003) were observed when using the high-damping foot compared with low-damping foot. Within each foot, uninvolved limb first peak IAM and loading rates had a trend to increase with increased walking speed. These findings suggest that damping properties of prosthetic feet are related to uninvolved limb peak knee IAM and loading rates.


Assuntos
Membros Artificiais , Pé/fisiologia , Articulação do Joelho/fisiologia , Caminhada/fisiologia , Suporte de Carga/fisiologia , Antropometria , Fenômenos Biomecânicos , Feminino , Voluntários Saudáveis , Humanos , Masculino , Desenho de Prótese , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA