Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Base de dados
Tipo de documento
Ano de publicação
Intervalo de ano de publicação
1.
Clin Endocrinol (Oxf) ; 101(3): 195-202, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38798198

RESUMO

BACKGROUND: Adrenal insufficiency (AI) is a life-threatening condition which requires long term glucocorticoid replacement. The insulin tolerance test (ITT) is the current gold standard test for diagnosis of secondary AI, but the widely accepted cut-off value of a peak cortisol of less than 500 nmol/L assumes that anyone who does not reach this value has AI and thus requires full replacement. The cut-off used to diagnose AI is also founded on outdated assays. Use of this cut-off in an era of more specific immunoassays therefore risks misdiagnosis, subsequent unnecessary glucocorticoid exposure and associated adverse effects with increased mortality risk. DESIGN, PATIENTS AND MEASUREMENTS: This retrospective analysis assessed 300 ITT cortisol responses using the Abbott Architect and Alinity analyser platforms in patients with suspected AI over a period of 12 years (August 2010 to January 2022), at a tertiary centre. RESULTS: Patients were classified as having AI or not, based on a comprehensive clinical review of electronic patient records from the point of test to the present day by a panel of pituitary and adrenal specialists. Using the current institutional cut-off value of 500 nmol/L, receiver operating characteristic analysis identified a 100.0% sensitivity and 43.6% specificity (area under the curve 0.979). Using a lower cortisol threshold value of 416 nmol/L on the Abbott analyser platform maintained a sensitivity of 100.0% and improved the specificity to 86.7%. CONCLUSION: This data supports lowering the Abbott analyser ITT peak cortisol threshold to 416 nmol/L. Use of this improved cut-off avoids unnecessary glucocorticoid replacement therapy in 104 (34.7%) of individuals in this study. All patients remained well with at least 1 year longitudinal follow up of glucocorticoid replacement.


Assuntos
Insuficiência Adrenal , Erros de Diagnóstico , Hidrocortisona , Humanos , Insuficiência Adrenal/diagnóstico , Insuficiência Adrenal/sangue , Estudos Retrospectivos , Hidrocortisona/sangue , Hidrocortisona/análise , Feminino , Pessoa de Meia-Idade , Masculino , Adulto , Erros de Diagnóstico/prevenção & controle , Idoso , Insulina , Glucocorticoides/uso terapêutico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA