Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 58
Filtrar
1.
Ann Vasc Surg ; 34: 250-60, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27116907

RESUMO

BACKGROUND: Visceral arteries are commonly involved in endovascular repair of complex abdominal aortic aneurysms (AAAs). To improve repair techniques and reduce long-term complications involving visceral arteries, it is crucial to understand in vivo arterial geometry and the deformations due to visceral organ movement with respiration. This study quantifies deformation of the celiac, superior mesenteric (SMA), and renal arteries during respiration and correlates the deformations with diaphragmatic excursion. METHODS: Sixteen patients with small AAAs underwent magnetic resonance angiography during inspiratory and expiratory breathholds. From geometric models of the aorta and visceral arteries, vessel length, branch angle, curvature, and positions were computed, along with degree of diaphragmatic excursion as indicated by kidney translation. RESULTS: From inspiration to expiration, the celiac artery exhibited axial shortening of 4.8 ± 6.4% (P < 0.001) and a mean curvature increase of 0.03 ± 0.02 mm(-1), greater than other visceral arteries (P < 0.01). With expiration, the SMA, left and right renal arteries (LRA and RRA) angled upward by -9.8 ± 6.4°, -6.4 ± 6.4°, and -5.2 ± 5.0°, respectively (P < 0.005). All vessels translated superiorly (P < 0.0005) and posteriorly (P < 0.01), and the SMA translated rightward additionally (P < 0.005). The left and right kidneys translated by 22 ± 9 mm and 21 ± 9 mm, mostly superiorly (P < 0.001). Translations of all visceral arteries were moderately correlated to the right kidney (R > 0.50). Correlation of the LRA with the left kidney was greater than that of the RRA with the right kidney. CONCLUSIONS: The celiac artery exhibited less branch angle change, and greater axial and curvature deformations than the other visceral arteries, due to the vicinity to the liver and influence of the median arcuate ligament. Correlation between visceral arteries and kidney translations revealed that diaphragmatic excursion affects vessel mobility. Weaker correlation of the RRA to the right kidney indicates mechanical shielding from the inferior vena cava.


Assuntos
Aneurisma da Aorta Abdominal/diagnóstico por imagem , Artéria Celíaca/diagnóstico por imagem , Imageamento Tridimensional , Rim/diagnóstico por imagem , Angiografia por Ressonância Magnética , Artéria Mesentérica Superior/diagnóstico por imagem , Modelos Cardiovasculares , Artéria Renal/diagnóstico por imagem , Respiração , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/fisiopatologia , Suspensão da Respiração , Expiração , Feminino , Humanos , Interpretação de Imagem Assistida por Computador , Inalação , Masculino , Movimento , Valor Preditivo dos Testes
2.
J Magn Reson Imaging ; 38(4): 938-45, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23371926

RESUMO

PURPOSE: To determine whether a multiphase method with high spatiotemporal resolution (STR) by means of a combination of parallel imaging, pseudorandom sampling and temporal view sharing improves the capture and intensity of gadoxetate arterial phase images as well as lesion enhancement. MATERIALS AND METHODS: Thirty-seven patients were imaged with a conventional spoiled gradient echo acquisition and 48 with a high STR multiphase acquisition after the administration of gadoxetate. Arterial phase capture, image quality, and quality of fat suppression were qualitatively graded. Fourteen lesions in the conventional group and 28 in the high STR multiphase group were imaged, including 34 focal nodular hyperplasias. The ratio of lesion to parenchyma enhancement as well as relative hepatic artery enhancement were calculated. Chi-squared, Mann-Whitney U and student t-tests were used to compare differences. RESULTS: The high STR multiphase acquisition included the arterial phase more frequently than conventional acquisitions (P < 0.001), with the arterial phase missed in 17% (95% CI of 4-28%) of patients with conventional acquisition compared with 2% (95% CI of 0-6%) with the high STR multiphase acquisition. There was no loss of image quality or degree of fat saturation. Additionally, there was increased relative intensity of the hepatic arteries (P < 0.001) as well as lesion enhancement (P = 0.01). CONCLUSION: The high STR multiphase acquisition resulted in more reliable gadoxetate arterial phase capture compared with a conventional acquisition while preserving image quality with robust fat saturation.


Assuntos
Artérias/patologia , Gadolínio DTPA/química , Imageamento Tridimensional , Imageamento por Ressonância Magnética , Meios de Contraste/química , Hiperplasia Nodular Focal do Fígado/patologia , Humanos , Processamento de Imagem Assistida por Computador , Reprodutibilidade dos Testes , Estudos Retrospectivos , Software , Fatores de Tempo
3.
J Magn Reson Imaging ; 38(6): 1325-32, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23553967

RESUMO

PURPOSE: To quantify renal artery deformation due to respiration using magnetic resonance (MR) image-based geometric analysis. MATERIALS AND METHODS: Five males were imaged with contrast-enhanced MR angiography during inspiratory and expiratory breath-holds. From 3D models of the abdominal aorta, left and right renal arteries (LRA and RRA), we quantified branching angle, curvature, peak curve angle, axial length, and locations of branch points. RESULTS: With expiration, maximum curvature changes were 0.054 ± 0.025 mm(-1) (P < 0.01), and curve angle at the most proximal curvature peak increased by 8.0 ± 4.5° (P < 0.05) in the LRA. Changes in maximum curvature and curve angles were not significant in the RRA. The first renal bifurcation point translated superiorly and posteriorly by 9.7 ± 3.6 mm (P < 0.005) and 3.5 ± 2.1 mm (P < 0.05), respectively, in the LRA, and 10.8 ± 6.1 mm (P < 0.05) and 3.6 ± 2.5 mm (P < 0.05), respectively, in the RRA. Changes in branching angle, axial length, and renal ostia locations were not significant. CONCLUSION: The LRA and RRA deformed and translated significantly. Greater deformation of the LRA as compared to the RRA may be due to asymmetric anatomy and mechanical support by the inferior vena cava. The presented methodology can extend to quantification of deformation of diseased and stented arteries to help renal artery implant development.


Assuntos
Expiração/fisiologia , Imageamento Tridimensional/métodos , Inalação/fisiologia , Angiografia por Ressonância Magnética/métodos , Modelos Anatômicos , Artéria Renal/anatomia & histologia , Artéria Renal/fisiologia , Adulto , Idoso , Suspensão da Respiração , Simulação por Computador , Módulo de Elasticidade/fisiologia , Humanos , Masculino , Pessoa de Meia-Idade , Modelos Biológicos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
4.
J Vasc Interv Radiol ; 24(7): 1035-42, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23796090

RESUMO

PURPOSE: To quantify respiration-induced deformations of the superior mesenteric artery (SMA), left renal artery (LRA), and right renal artery (RRA) in patients with small abdominal aortic aneurysms (AAAs). MATERIALS AND METHODS: Sixteen men with AAAs (age 73 y ± 7) were imaged with contrast-enhanced magnetic resonance angiography during inspiratory and expiratory breath-holds. Centerline paths of the aorta and visceral arteries were acquired by geometric modeling and segmentation techniques. Vessel translations and changes in branching angle and curvature resulting from respiration were computed from centerline paths. RESULTS: With expiration, the SMA, LRA, and RRA bifurcation points translated superiorly by 12.4 mm ± 9.5, 14.5 mm ± 8.8, and 12.7 mm ± 6.4 (P < .001), and posteriorly by 2.2 mm ± 2.7, 4.9 mm ± 4.2, and 5.6 mm ± 3.9 (P < .05), respectively, and the SMA translated rightward by 3.9 mm ± 4.9 (P < .01). With expiration, the SMA, LRA, and RRA angled upward by 9.7° ± 6.4, 7.5° ± 7.8, and 4.9° ± 5.3, respectively (P < .005). With expiration, mean curvature increased by 0.02 mm(-1) ± 0.01, 0.01 mm(-1) ± 0.01, and 0.01 mm(-1) ± 0.01 in the SMA, LRA, and RRA, respectively (P < .05). For inspiration and expiration, RRA curvature was greater than in other vessels (P < .025). CONCLUSIONS: With expiration, the SMA, LRA, and RRA translated superiorly and posteriorly as a result of diaphragmatic motion, inducing upward angling of vessel branches and increased curvature. In addition, the SMA exhibited rightward translation with expiration. The RRA was significantly more tortuous, but deformed less than the other vessels during respiration.


Assuntos
Aneurisma da Aorta Abdominal/patologia , Expiração , Inalação , Artéria Mesentérica Superior/patologia , Artéria Renal/patologia , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/fisiopatologia , Suspensão da Respiração , Humanos , Interpretação de Imagem Assistida por Computador , Angiografia por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes
5.
AJR Am J Roentgenol ; 201(6): 1303-8, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24261371

RESUMO

OBJECTIVE: Separation methods exploit the different precessional frequencies of fat and water protons. They offer potential benefits to body MRI but are not routinely used in most practices. After a review of the technique, we highlight through cases promising applications of this technology, including using water-only series to obtain more robust fat-suppressed images, shortening MRI scanning protocol time, and achieving perfect coregistering of fat-suppressed and non-fat-suppressed images. CONCLUSION: As technology has advanced, fat-water separation techniques have shown that they can be valuable tools for a body MRI practice, particularly when the presence or absence of fat, homogeneity of fat saturation, coregistration, or quantitative evaluation is critical.


Assuntos
Tecido Adiposo , Água Corporal , Aumento da Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Prótons , Meios de Contraste , Humanos , Imageamento Tridimensional
6.
AJR Am J Roentgenol ; 198(3): W250-9, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22358022

RESUMO

OBJECTIVE: The quantification of cardiac flow and ventricular volumes is an essential goal of many congenital heart MRI examinations, often requiring acquisition of multiple 2D phase-contrast and bright-blood cine steady-state free precession (SSFP) planes. Scan acquisition, however, is lengthy and highly reliant on an imager who is well-versed in structural heart disease. Although it can also be lengthy, 3D time-resolved (4D) phase-contrast MRI yields global flow patterns and is simpler to perform. We therefore sought to accelerate 4D phase contrast and to determine whether equivalent flow and volume measurements could be extracted. MATERIALS AND METHODS: Four-dimensional phase contrast was modified for higher acceleration with compressed sensing. Custom software was developed to process 4D phase-contrast images. We studied 29 patients referred for congenital cardiac MRI who underwent a routine clinical protocol, including cine short-axis stack SSFP and 2D phase contrast, followed by contrast-enhanced 4D phase contrast. To compare quantitative measurements, Bland-Altman analysis, paired Student t tests, and F tests were used. RESULTS: Ventricular end-diastolic, end-systolic, and stroke volumes obtained from 4D phase contrast and SSFP were well correlated (ρ = 0.91-0.95; r(2) = 0.83-0.90), with no statistically significant difference. Ejection fractions were well correlated in a subpopulation that underwent higher-resolution compressed-sensing 4D phase contrast (ρ = 0.88; r(2) = 0.77). Four-dimensional phase contrast and 2D phase contrast flow rates were also well correlated (ρ = 0.90; r(2) = 0.82). Excluding ventricles with valvular insufficiency, cardiac outputs derived from outlet valve flow and stroke volumes were more consistent by 4D phase contrast than by 2D phase contrast and SSFP. CONCLUSION: Combined parallel imaging and compressed sensing can be applied to 4D phase contrast. With custom software, flow and ventricular volumes may be extracted with comparable accuracy to SSFP and 2D phase contrast. Furthermore, cardiac outputs were more consistent by 4D phase contrast.


Assuntos
Cardiopatias Congênitas/fisiopatologia , Imagem Cinética por Ressonância Magnética/métodos , Disfunção Ventricular Esquerda/fisiopatologia , Adolescente , Adulto , Velocidade do Fluxo Sanguíneo , Criança , Pré-Escolar , Meios de Contraste , Feminino , Gadolínio , Gadolínio DTPA , Humanos , Interpretação de Imagem Assistida por Computador , Imageamento Tridimensional , Lactente , Masculino , Compostos Organometálicos , Estudos Retrospectivos , Volume Sistólico
7.
J Vasc Interv Radiol ; 22(2): 244-9, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21276917

RESUMO

PURPOSE: The authors have developed a direct method to study femoral artery stent deformations in vivo. A previously described imaging and analysis approach based on a calibrated phantom was used to examine stents in human volunteers treated for atherosclerotic disease. In this pilot study, forces on stents were evaluated under different in-vivo flexion conditions. MATERIALS AND METHODS: The optimized imaging protocol for imaging with a C-arm computed tomography system was first verified in an in-vivo porcine stent model. Human data were obtained by imaging 13 consenting volunteers with stents in femoral vessels. The affected leg was imaged in straight and bent positions to observe stent deformations. Semiautomatic software was used to calculate the changes in bending, extension, and torsion on the stents for the two positions. RESULTS: For the human studies, tension and bending calculation were successful. Bending was found to compress stent lengths by 4% ± 3% (-14.2 to 1.5 mm), increase their average eccentricity by 10% ± 9% (0.12 to -0.16), and change their mean curvature by 27% ± 22% (0 to -0.005 mm(-1)). Stents with the greatest change in eccentricity and curvature were located behind the knee or in the pelvis. Torsion calculations were difficult because the stents were untethered and are symmetric. In addition, multiple locations in each stent underwent torsional deformations. CONCLUSIONS: The imaging and analysis approach developed based on calibrated in vitro measurements was extended to in-vivo data. Bending and tension forces were successfully evaluated in this pilot study.


Assuntos
Ligas , Angiografia/métodos , Prótese Vascular , Artéria Femoral/diagnóstico por imagem , Artéria Femoral/cirurgia , Stents , Tomografia Computadorizada por Raios X/métodos , Idoso , Animais , Módulo de Elasticidade , Análise de Falha de Equipamento/métodos , Feminino , Humanos , Masculino , Desenho de Prótese , Suínos
8.
AJR Am J Roentgenol ; 197(4): 816-26, 2011 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21940568

RESUMO

OBJECTIVE: Noninvasive imaging of the heart and coronary vasculature using CT and MRI is a new and exciting opportunity for radiologists. The purpose of this pictorial essay is to review normal and variant anatomy of the coronary arteries and of several coronary anomalies that may be clinically significant. The coronary veins and artifacts simulating disease will also be briefly covered. This article will help radiologists learn and review normal coronary anatomy, normal variants, and coronary anomalies and recognize pitfalls, such as coronary veins and artifacts, that may be confusing when first encountered. CONCLUSION: The coronary arteries generally are predictable in their origin, course, and perfusion territories. Standardized reporting systems exist for describing the location of specific lesions, and radiologists who interpret CT and MR coronary images should be aware of and should attempt to integrate these reporting schemes into clinical practice.


Assuntos
Anomalias dos Vasos Coronários/diagnóstico , Artefatos , Meios de Contraste , Doença das Coronárias/diagnóstico , Vasos Coronários/anatomia & histologia , Humanos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Tomografia Computadorizada por Raios X/métodos
9.
Pediatr Radiol ; 41(6): 711-20, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21221566

RESUMO

BACKGROUND: Cardiovascular flow is commonly assessed with two-dimensional, phase-contrast MRI (2-D PC-MRI). However, scan prescription and acquisition over multiple planes is lengthy, often requires direct physician oversight and has inconsistent results. Time-resolved volumetric PC-MRI (4-D flow) may address these limitations. OBJECTIVE: We assess the degree of agreement and internal consistency between 2-D and 4-D flow quantification in our clinical population. MATERIALS AND METHODS: Software enabling flow calculation from 4-D flow was developed in Java. With IRB approval and HIPAA compliance, 18 consecutive patients without shunts were identified who underwent both (1) conventional 2-D PC-MRI of the aorta and main pulmonary artery and (2) 4-D flow imaging. Aortic and pulmonary flow rates were assessed with both techniques. RESULTS: Both methods showed general agreement in flow rates (ρ: 0.87-0.90). Systemic and pulmonary arterial flow rates were well-correlated (ρ: 4-D 0.98-0.99, 2-D 0.93), but more closely matched with 4-D (P < 0.05, Brown-Forsythe). Pulmonary flow rates were lower than systemic rates for 2-D (P < 0.05, two-sample t-test). In a sub-analysis of patients without pulmonary or aortic regurgitation, 2-D showed improved correlation of flow rates while 4-D phase-contrast remained tightly correlated (ρ: 4-D 0.99-1.00, 2-D 0.99). CONCLUSION: 4-D PC-MRI demonstrates greater consistency than conventional 2-D PC-MRI for flow quantification.


Assuntos
Algoritmos , Técnicas de Imagem de Sincronização Cardíaca/métodos , Circulação Coronária , Aumento da Imagem/métodos , Angiografia por Ressonância Magnética/métodos , Imagem Cinética por Ressonância Magnética/métodos , Circulação Pulmonar , Adolescente , Adulto , Criança , Pré-Escolar , Feminino , Humanos , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
10.
J Magn Reson Imaging ; 31(2): 425-9, 2010 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-20099356

RESUMO

PURPOSE: To evaluate rest and exercise hemodynamics in patients with abdominal aortic aneurysms (AAA) and peripheral occlusive disease (claudicants) using phase-contrast MRI. MATERIALS AND METHODS: Blood velocities were acquired by means of cardiac-gated cine phase-contrast in a 0.5 Tesla (T) open MRI. Volumetric flow was calculated at the supraceliac (SC), infrarenal (IR), and mid-aneurysm (MA) levels during rest and upright cycling exercise using an MR-compatible exercise cycle. RESULTS: Mean blood flow increased during exercise (AAA: 130%, Claudicants: 136% of resting heart rate) at the SC and IR levels for AAA participants (2.6 +/- 0.6 versus 5.8 +/- 1.6 L/min, P < 0.001 and 0.8 +/- 0.4 versus 5.1 +/- 1.7 L/min, P < 0.001) and claudicants (2.3 +/- 0.5 versus 4.5 +/- 0.9 L/min, P < 0.005 and 0.8 +/- 0.2 versus 3.3 +/- 0.9 L/min, P < 0.005). AAA participants had a significant decrease in renal and digestive blood flow from rest to exercise (1.8 +/- 0.7 to 0.7 +/- 0.6 L/min, P < 0.01). The decrease in renal and digestive blood flow during exercise correlated with daily activity level for claudicants (R = 0.81). CONCLUSION: Abdominal aortic hemodynamic changes due to lower extremity exercise can be quantified in patients with AAA and claudication using PC-MRI. The redistribution of blood flow during exercise was significant and different between the two disease states.


Assuntos
Aneurisma da Aorta Abdominal/complicações , Aneurisma da Aorta Abdominal/diagnóstico , Teste de Esforço , Aumento da Imagem/métodos , Claudicação Intermitente/diagnóstico , Claudicação Intermitente/etiologia , Imagem Cinética por Ressonância Magnética/métodos , Idoso , Humanos , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
11.
J Vasc Interv Radiol ; 21(2): 195-202, 2010 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-20022767

RESUMO

PURPOSE: Vessel deformations have been implicated in endoluminal device fractures, and therefore better understanding of these deformations could be valuable for device regulation, evaluation, and design. The purpose of this study is to describe geometric changes of the superficial femoral artery (SFA) resulting from hip and knee flexion in older subjects. MATERIALS AND METHODS: The SFAs of seven healthy subjects aged 50-70 years were imaged with magnetic resonance angiography with the legs straight and with hip and knee flexion. From geometric models constructed from these images, axial, twisting, and bending deformations were quantified. RESULTS: There was greater shortening in the bottom third of the SFA than in the top two thirds (top, 5.9% +/- 3.0%; middle, 6.7% +/- 2.1%; bottom, 8.1% +/- 2.0% [mean +/- SD]; P < .05), significant twist in all sections (top, 1.3 degrees /cm +/- 0.8; middle, 1.8 degrees /cm +/- 1.1; bottom, 2.1 degrees /cm +/- 1.3), and greater curvature increase in the bottom third than in the top two thirds (top, 0.15 cm(-1) +/- 0.06; middle, 0.09 cm(-1) +/- 0.07; bottom, 0.41 cm(-1) +/- 0.22; P < .001). CONCLUSIONS: The SFA tends to deform more in the bottom third than in the other sections, likely because of less musculoskeletal constraint distal to the adductor canal and vicinity of knee flexion. The SFAs of these older subjects curve off axis with normal joint flexion, probably resulting from known loss of arterial elasticity with age. This slackening of the vessel enables a method for noninvasive quantification of in vivo SFA strain, which may be valuable for treatment planning and device design. In addition, the spatially resolved arterial deformations quantified in this study may be useful for commercial and regulatory device evaluation.


Assuntos
Envelhecimento/fisiologia , Artéria Femoral/anatomia & histologia , Articulação do Quadril/fisiologia , Articulação do Joelho/fisiologia , Angiografia por Ressonância Magnética , Fatores Etários , Idoso , Elasticidade , Humanos , Masculino , Pessoa de Meia-Idade , Modelos Cardiovasculares , Contração Muscular , Torção Mecânica
12.
AJR Am J Roentgenol ; 195(3): 687-91, 2010 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-20729447

RESUMO

OBJECTIVE: The purpose of our study was to evaluate image quality in a 3D spoiled gradient-recalled echo (SPGR) sequence that was modified to incorporate respiratory navigation to limit the deleterious effects of respiratory motion and to compare it with conventional scanning during breath-holding and free breathing. CONCLUSION: Respiratory navigation of 3D SPGR sequences is technically feasible, and image quality is modestly improved over free breathing acquisitions using conventional 3D SPGR sequences. This may represent a promising imaging alternative for patients who cannot hold their breath.


Assuntos
Imageamento Tridimensional , Hepatopatias/diagnóstico , Imageamento por Ressonância Magnética/métodos , Respiração , Adulto , Meios de Contraste , Feminino , Gadolínio DTPA , Humanos , Masculino , Pessoa de Meia-Idade , Estatísticas não Paramétricas
13.
Pediatr Radiol ; 40(3): 340-4, 2010 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-20066407

RESUMO

T1-W imaging of the pediatric abdomen is often limited by respiratory motion artifacts. Although navigation has been commonly employed for coronary MRA and T2-W imaging, navigation for T1-W imaging is less developed. Thus, we incorporated a navigator pulse into a fat-suppressed T1-W SPGR sequence such that steady-state contrast was not disrupted. Ten children were scanned after gadolinium administration three times in immediate succession: breath-hold with no navigation, free-breathing with navigation, and free-breathing without navigation. Motion artifacts were scored for each sequence by two radiologists,showing fewer motion artifacts with navigation compared to free-breathing and greater motion artifacts than with breath-holding. This work demonstrates the feasibility and potential utility of navigation for pediatric abdominal T1-W imaging.


Assuntos
Abdome/patologia , Artefatos , Aumento da Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Movimento , Mecânica Respiratória , Adolescente , Adulto , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
14.
Radiology ; 253(2): 390-8, 2009 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-19789237

RESUMO

PURPOSE: To use a rat model for nephrogenic systemic fibrosis (NSF) that was administered high-dose gadodiamide to determine whether the co-administration of erythropoietin (Epo) and intravenous iron potentiated development of skin lesions that are thought to be a marker for the development of NSF. MATERIALS AND METHODS: The local committee for animal research approved this study. High-dose gadodiamide was administered, 2.5 mmol per kilogram of body weight for 20 days, or 500 times the U.S. Food and Drug Administration-approved dose, to four groups of Hannover-Wistar rats: group A, gadodiamide only; B, gadodiamide and Epo; C, gadodiamide and intravenous iron; and D, gadodiamide, Epo, and intravenous iron. The animals were sacrificed 7 days after final injection, and the authors examined dermal histologic findings from each animal and measured metal deposition by using inductively coupled plasma mass spectrometry. To compare the effect of metal deposition and cellularity, a linear mixed effects model was used to fit the data within PROC MIXED modeled with rat-specific random effects, and subsequently a Dunnett adjustment was performed. RESULTS: Rats treated with gadodiamide and both Epo and intravenous iron (group D) had significantly worse skin lesions at gross and histologic analysis (P = .004) compared with the rate treated with gadodiamide only (group A). Group D also had increased levels of deposited gadolinium as measured by means of mass spectrometry (P = .012). CONCLUSION: With a rat model similar to those already existing in the literature, skin changes were more marked in animals exposed to gadodiamide, Epo, and intravenous iron, as opposed to those animals exposed to gadodiamide alone; this experiment suggests that great caution may be warranted when prescribing gadolinium-based contrast agents to patients receiving Epo and intravenous iron.


Assuntos
Meios de Contraste/toxicidade , Eritropoetina/toxicidade , Gadolínio DTPA/toxicidade , Complexo Ferro-Dextran/toxicidade , Dermopatia Fibrosante Nefrogênica/induzido quimicamente , Animais , Cálcio/metabolismo , Meios de Contraste/administração & dosagem , Sinergismo Farmacológico , Epoetina alfa , Gadolínio DTPA/administração & dosagem , Injeções Intravenosas , Complexo Ferro-Dextran/administração & dosagem , Masculino , Dermopatia Fibrosante Nefrogênica/metabolismo , Dermopatia Fibrosante Nefrogênica/patologia , Ratos , Ratos Wistar , Proteínas Recombinantes , Pele/metabolismo , Pele/patologia
15.
J Vasc Surg ; 49(6): 1580-4, 2009 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-19223146

RESUMO

We report the first utilization of time-resolved three-dimensional phase contrast magnetic resonance imaging, termed 4D flow, to image a type I endoleak after endovascular aneurysm repair. The combination of 4D flow and a traditional magnetic resonance angiogram can aid in the accurate detection and characterization of endoleaks by combining the three-dimensional resolution of cross-sectional imaging with the temporally resolved velocity data of Doppler ultrasound.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Meios de Contraste , Interpretação de Imagem Assistida por Computador , Imageamento Tridimensional , Angiografia por Ressonância Magnética , Falha de Prótese , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/patologia , Aneurisma da Aorta Abdominal/fisiopatologia , Velocidade do Fluxo Sanguíneo , Humanos , Masculino , Fluxo Sanguíneo Regional , Reoperação , Tomografia Computadorizada por Raios X , Falha de Tratamento , Ultrassonografia Doppler Dupla
16.
Semin Thorac Cardiovasc Surg ; 20(4): 358-64, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-19251177

RESUMO

Time-resolved three-dimensional (3D) phase-contrast (PC) magnetic resonance imaging (MRI), or four-dimensional (4D) flow, is able to provide robust 3D images with three-directional velocities. This review discusses the technique and application of 4D flow in the imaging of thoracic aortic pathologies. It has been instrumental in describing normal flow patterns throughout the cardiac cycle in the ascending and descending aorta and has shown the variety of flow patterns that exist in ascending aortic aneurysms.


Assuntos
Aorta Torácica , Doenças da Aorta/diagnóstico , Imageamento Tridimensional/métodos , Angiografia por Ressonância Magnética/métodos , Velocidade do Fluxo Sanguíneo , Meios de Contraste , Humanos , Interpretação de Imagem Assistida por Computador
17.
Semin Thorac Cardiovasc Surg ; 20(4): 333-9, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-19251174

RESUMO

Cardiovascular imaging technology is continuously evolving and provides an increasing array of tests to evaluate cardiovascular morphology and function. A basic understanding of imaging technology is helpful to select the best modality to answer a specific clinical question. This article provides a brief overview of recent technical developments in computed tomography (CT), magnetic resonance (MR), and echocardiography, which have increased our diagnostic understanding and may modulate treatment planning of patients with cardiovascular diseases: electrocardiographically (ECG)-gated CT, 4D-flow magnetic resonance imaging (MRI), and three-dimensional (3D) echocardiography.


Assuntos
Doenças Cardiovasculares/diagnóstico , Ecocardiografia/tendências , Imageamento por Ressonância Magnética/tendências , Tomografia Computadorizada por Raios X/tendências , Meios de Contraste , Eletrocardiografia , Humanos , Interpretação de Imagem Assistida por Computador , Imageamento Tridimensional , Doses de Radiação
18.
Breast J ; 14(6): 574-80, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-19000051

RESUMO

To assess which specific morphologic features, enhancement patterns, or pharmacokinetic parameters on breast Magnetic Resonance Imaging (MRI) could predict a false-negative outcome of Proton MR Spectroscopy ((1)H MRS) exam in patients with invasive breast cancer. Sixteen patients with invasive ductal carcinoma of the breast were prospectively included and underwent both, contrast-enhanced breast MRI and (1)H MRS examination of the breast. The MR images were reviewed and the lesions morphologic features, enhancement patterns and pharmacokinetic parameters (k21-value) were scored according to the ACR BI-RADS-MRI lexicon criteria. For the in vivo MRS studies, each spectrum was evaluated for the presence of choline based on consensus reading. Breast MRI and (1)H MRS data were compared to histopathologic findings. In vivo (1)H MRS detected a choline peak in 14/16 (88%) cancers. A false-negative (1)H MRS study occurred in 2/16 (14%) cancer patients. K21 values differed between both groups: the 14 choline positive cancers had k21 values ranging from 0.01 to 0.20/second (mean 0.083/second), whereas the two choline-negative cancers showed k21 values of 0.03 and 0.05/second, respectively (mean 0.040/second). Also enhancement kinetics did differ between both groups; typically both cancers that were choline-negative showed a late phase plateau (100%), whereas this was only shown in 5/14 (36%) of the choline positive cases. There was no difference between both groups with regard to morphologic features on MRI. This study showed that false-negative (1)H MRS examinations do occur in breast cancer patients, and that the presence of a choline peak on (1)H MRS as malignancy marker is related to the k21 value of the invasive tumor being imaged.


Assuntos
Biomarcadores Tumorais/análise , Neoplasias da Mama/diagnóstico , Carcinoma Ductal de Mama/patologia , Colina/análise , Imageamento por Ressonância Magnética/métodos , Espectroscopia de Ressonância Magnética/métodos , Adulto , Idoso , Neoplasias da Mama/patologia , Reações Falso-Negativas , Feminino , Humanos , Aumento da Imagem , Pessoa de Meia-Idade , Invasividade Neoplásica , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
19.
Int J Radiat Oncol Biol Phys ; 66(2): 462-8, 2006 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-16965993

RESUMO

PURPOSE: To evaluate indirect magnetic resonance lymphangiography (MR-LAG) using interstitial injection of conventional gadolinium contrast (gadoteridol and gadopentetate dimeglumine) for delineating the primary lymphatic drainage of head-and-neck sites. METHODS AND MATERIALS: We performed head-and-neck MR-LAG in 5 healthy volunteers, with injection of dermal and mucosal sites. We evaluated the safety of the procedure, the patterns of enhancement categorized by injection site and nodal level, the time course of enhancement, the optimal concentration and volume of contrast, and the optimal imaging sequence. RESULTS: The worst side effects of interstitial contrast injection were brief, mild pain and swelling at the injected sites that were self-limited. MR-LAG resulted in consistent visualization of the primary lymphatic drainage pattern specific to each injected site, which was reproducible on repeated examinations. The best enhancement was obtained with injection of small volumes (0.3-0.5 mL) of either agent diluted, imaging within 5-15 min of injection, and a three-dimensional fast spoiled gradient echo sequence with magnetization transfer. CONCLUSIONS: We found head-and-neck MR-LAG to be a safe, convenient imaging method that provides functional information about the lymphatic drainage of injected sites. Applied to head-and-neck cancer, it has the potential to identify sites at highest risk of occult metastatic spread for radiotherapy or surgical planning, and possibly to visualize micrometastases.


Assuntos
Meios de Contraste , Gadolínio DTPA , Cabeça/diagnóstico por imagem , Compostos Heterocíclicos , Linfografia/métodos , Pescoço/diagnóstico por imagem , Compostos Organometálicos , Adulto , Meios de Contraste/efeitos adversos , Feminino , Gadolínio , Gadolínio DTPA/efeitos adversos , Compostos Heterocíclicos/efeitos adversos , Humanos , Linfografia/efeitos adversos , Imageamento por Ressonância Magnética/métodos , Masculino , Compostos Organometálicos/efeitos adversos , Projetos Piloto , Cintilografia
20.
Magn Reson Imaging ; 24(10): 1363-7, 2006 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-17145408

RESUMO

OBJECTIVE: This study investigates the use of contrast-enhanced, T1-weighted, water-selective spectral-spatial 3D gradient echo magnetic resonance imaging (MRI) with magnetization transfer (3DSSMT) for detecting breast cancer in patients with intraparenchymal silicone. CONCLUSION: Water-selective 3DSSMT provides superior fat and silicone suppression in patients with free silicone as compared with conventional fat saturation. It enables direct, high-quality, high-spatial-resolution, T1-weighted breast MRI of contrast enhancement without the need for subtraction processing and aids diagnosis of cancer in the breast with free silicone.


Assuntos
Implantes de Mama , Neoplasias da Mama/diagnóstico , Imageamento por Ressonância Magnética/métodos , Géis de Silicone , Adulto , Idoso , Meios de Contraste , Feminino , Humanos , Pessoa de Meia-Idade , Estudos Retrospectivos , Água
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA