RESUMO
Tetrazines (Tz) have been applied as bioorthogonal agents for various biomedical applications, including pretargeted imaging approaches. In radioimmunoimaging, pretargeting increases the target-to-background ratio while simultaneously reducing the radiation burden. We have recently reported a strategy to directly 18F-label highly reactive tetrazines based on a 3-(3-fluorophenyl)-Tz core structure. Herein, we report a kinetic study on this versatile scaffold. A library of 40 different tetrazines was prepared, fully characterized, and investigated with an emphasis on second-order rate constants for the reaction with trans-cyclooctene (TCO). Our results reveal the effects of various substitution patterns and moreover demonstrate the importance of measuring reactivities in the solvent of interest, as click rates in different solvents do not necessarily correlate well. In particular, we report that tetrazines modified in the 2-position of the phenyl substituent show high intrinsic reactivity toward TCO, which is diminished in aqueous systems by unfavorable solvent effects. The obtained results enable the prediction of the bioorthogonal reactivity and thereby facilitate the development of the next generation of substituted aryltetrazines for in vivo applications.
Assuntos
Diagnóstico por Imagem , Linhagem Celular Tumoral , SolventesRESUMO
OBJECTIVES: Current methods of diagnosing superior semicircular canal dehiscence syndrome (SCDS) include a clinical exam, audiometric testing, temporal bone computer tomography (CT) imaging, and vestibular evoked myogenic potential (VEMP) testing. The main objective of this study was to develop an improved diagnostic approach to SCDS optimized for accuracy, efficiency, and safety that utilizes clinical presentation, audiometric testing, CT imaging, high-frequency cervical VEMP (cVEMP) testing, and patient treatment preference. A secondary aim was to investigate the cost associated with the current versus proposed diagnostic paradigms. DESIGN: All patients who underwent cVEMP testing since introduction of the 2 kHz cVEMP in our clinical protocol in July 2018 were screened. Patients suspected of SCDS based upon symptoms who also had available audiogram, CT scan, and 2 kHz cVEMP were included (58 ears). Patients were categorized as dehiscent, thin, or not dehiscent based on their CT scan. Symptom prevalence and cVEMP outcomes were analyzed and compared for all groups. The accuracy of the 2 kHz cVEMP was calculated using CT imaging as the standard. Using a combination of patient symptomatology, audiometric, CT and 2 kHz cVEMP data, as well as patient preference, a best clinical practice approach was developed. The cost associated with this approach was calculated and compared with cost of the current SCDS diagnostic workup using Medicare reimbursement rates. RESULTS: In the overall patient population suspected of SCDS based on clinical presentation, the sensitivity and specificity of 2 kHz cVEMP were 76% and 100%, respectively, while the positive and negative predictive values were 100% and 84.6%, assuming that the CT scan finding was correct. Autophony was the most common symptom in patients who had both superior semicircular canal dehiscence on CT imaging plus abnormal 2 kHz cVEMP (p < 0.001). Combining patient symptomatology, 2 kHz normalized peak to peak cVEMP amplitude, and patient treatment preference to determine, which patients should undergo CT scanning resulted in a potential cost reduction between 45% and 61%. CONCLUSION: In patients suspected of SCDS based on their clinical presentation, the combination of symptomatology, 2 kHz cVEMP data, and patient preference can be used to determine which patients should undergo CT scanning, resulting in a diagnostic cost reduction and reduced patient radiation exposure.
Assuntos
Deiscência do Canal Semicircular , Potenciais Evocados Miogênicos Vestibulares , Idoso , Humanos , Medicare , Estudos Retrospectivos , Canais Semicirculares/diagnóstico por imagem , Osso Temporal/diagnóstico por imagem , Estados UnidosRESUMO
OBJECTIVES: Factors contributing to auditory brainstem implant (ABI) outcomes are poorly understood. The aims of this study are to (1) characterize ABI electrode array position on postoperative imaging and (2) determine if variability in position is related to perceptual outcomes. DESIGN: Retrospective cohort study. Subjects were selected from the adult ABI recipient population at Massachusetts Eye and Ear. Postoperative three-dimensional (3D) computed tomography (CT) reconstruction of the head was used to measure ABI array position in 20 adult ABI recipients (17 with Neurofibromatosis Type 2 (NF2) and three non-NF2 recipients). Three-dimensional electrode array position was determined based on angles from the horizontal using posterior and lateral views and on distances between the proximal array tip superiorly from the basion (D1), laterally (D2P) and posteriorly (D2L) from the midline. Array position was correlated with perceptual data (in 15 of the 20 recipients who used their ABI). Perceptual data included the number of electrodes that provided auditory sensation, location and type of side effects, level of speech perception (from no sound to open-set word recognition of monosyllables) and the amount of charge required for auditory perception. RESULTS: Although the 3D orientation of the ABI array exhibited a variety of angles, all arrays were posteriorly tilted from the lateral view and most were medially tilted from the posterior view. ABI position relative to the basion from posterior showed mean distances of 1.71 ± 0.42 and 1.1 ± 0.29 cm for D1 and D2, respectively, and a mean D2 of 1.30 ± 0.45 cm from the lateral view. A strong linear negative correlation was found between the number of active electrodes and the distance of the proximal array tip laterally from the basion (D2P; rs = -0.73, p = 0.006) when measured in the posterior view. Although side effects were experienced in all recipients and varied in type and location across the array, electrodes in the middle part of the array tended to elicit auditory sensations while the proximal and distal tips of the array tended to elicit nonauditory side effects. Arrays with and without low charge thresholds appeared to generally overlap in position. However, the two recipients with the best (open-set) speech perception had low charge thresholds and had arrays that were tilted superiorly in the posterior view. CONCLUSION: ABI recipients with better speech perception appear to share a profile of arrays that are tilted superiorly as compared to recipients with lower speech perception levels. These ABI recipients have a high number of active electrodes (10 or more) and require less electrical charge on individual electrodes to achieve optimal stimulation.
Assuntos
Implante Auditivo de Tronco Encefálico , Implantes Auditivos de Tronco Encefálico , Neurofibromatose 2 , Percepção da Fala , Adulto , Implante Auditivo de Tronco Encefálico/métodos , Eletrodos , Humanos , Neurofibromatose 2/complicações , Neurofibromatose 2/diagnóstico por imagem , Neurofibromatose 2/cirurgia , Estudos Retrospectivos , Percepção da Fala/fisiologia , Tomografia Computadorizada por Raios XRESUMO
Bioorthogonal chemistry is bridging the divide between static chemical connectivity and the dynamic physiologic regulation of molecular state, enabling in situ transformations that drive multiple technologies. In spite of maturing mechanistic understanding and new bioorthogonal bond-cleavage reactions, the broader goal of molecular ON/OFF control has been limited by the inability of existing systems to achieve both fast (i.e., seconds to minutes, not hours) and complete (i.e., >99%) cleavage. To attain the stringent performance characteristics needed for high fidelity molecular inactivation, we have designed and synthesized a new C2-symmetric trans-cyclooctene linker (C2TCO) that exhibits excellent biological stability and can be rapidly and completely cleaved with functionalized alkyl-, aryl-, and H-tetrazines, irrespective of click orientation. By incorporation of C2TCO into fluorescent molecular probes, we demonstrate highly efficient extracellular and intracellular bioorthogonal disassembly via omnidirectional tetrazine-triggered cleavage.
Assuntos
Ciclo-Octanos/química , Sondas Moleculares/química , Anticorpos/química , Anticorpos/metabolismo , Carbono/química , Química Click , Corantes Fluorescentes/química , IsomerismoRESUMO
OBJECTIVES: To determine the most effective method for normalizing cervical vestibular evoked myogenic potentials (cVEMPs). DESIGN: cVEMP data from 20 subjects with normal hearing and vestibular function were normalized using 16 combinations of methods, each using one of the 4 modes of electromyogram (EMG) quantification described below. All methods used the peak to peak value of an averaged cVEMP waveform (VEMPpp) and obtained a normalized cVEMP by dividing VEMPpp by a measure of the EMG amplitude. EMG metrics were obtained from the EMG within short- and long-duration time windows. EMG amplitude was quantified by its root-mean-square (RMS) or average full-wave-rectified (RECT) value. The EMG amplitude was used by (a) dividing each individual trace by the EMG of this specific trace, (b) dividing VEMPpp by the average RMS or RECT of the individual trace EMG, (c) dividing the VEMPpp by an EMG metric obtained from the average cVEMP waveform, or (d) dividing the VEMPpp by an EMG metric obtained from an average cVEMP "noise" waveform. Normalization methods were compared by the normalized cVEMP coefficient of variation across subjects and by the area under the curve from a receiver-operating-characteristic analysis. A separate analysis of the effect of EMG-window duration was done. RESULTS: There were large disparities in the results from different normalization methods. The best methods used EMG metrics from individual-trace EMG measurements, not from part of the average cVEMP waveform. EMG quantification by RMS or RECT produced similar results. For most EMG quantifications, longer window durations were better in producing receiver-operating-characteristic with high areas under the curve. However, even short window durations worked well when the EMG metric was calculated from the average RMS or RECT of the individual-trace EMGs. Calculating the EMG from a long-duration window of a cVEMP "noise" average waveform was almost as good as the individual-trace-EMG methods. CONCLUSIONS: The best cVEMP normalizations use EMG quantification from individual-trace EMGs. To have the normalized cVEMPs accurately reflect the vestibular activation, a good normalization method needs to be used.
Assuntos
Eletromiografia/métodos , Músculos do Pescoço/fisiologia , Potenciais Evocados Miogênicos Vestibulares/fisiologia , Adulto , Feminino , Voluntários Saudáveis , Humanos , Masculino , Pessoa de Meia-Idade , Curva ROC , Adulto JovemRESUMO
BACKGROUND: The cervical vestibular evoked myogenic potential (cVEMP) test measures saccular and inferior vestibular nerve function. The cVEMP can be elicited with different frequency stimuli and interpreted using a variety of metrics. Patients with superior semicircular canal dehiscence (SCD) syndrome generally have lower cVEMP thresholds and larger amplitudes, although there is overlap with healthy subjects. The aim of this study was to evaluate which metric and frequency best differentiate healthy ears from SCD ears using cVEMP. METHODS: Twenty-one patients with SCD and 23 age-matched controls were prospectively included and underwent cVEMP testing at 500, 750, 1,000 and 2,000 Hz. Sound level functions were obtained at all frequencies to acquire threshold and to calculate normalized peak-to-peak amplitude (VEMPn) and VEMP inhibition depth (VEMPid). Third window indicator (TWI) metrics were calculated by subtracting the 250-Hz air-bone gap from the ipsilateral cVEMP threshold at each frequency. Ears of SCD patients were divided into three groups based on CT imaging: dehiscent, thin or unaffected. The ears of healthy age-matched control subjects constituted a fourth group. RESULTS: Comparing metrics at all frequencies revealed that 2,000-Hz stimuli were most effective in differentiating SCD from normal ears. ROC analysis indicated that for both 2,000-Hz cVEMP threshold and for 2,000-Hz TWI, 100% specificity could be achieved with a sensitivity of 92.0%. With 2,000-Hz VEMPn and VEMPid at the highest sound level, 100% specificity could be achieved with a sensitivity of 96.0%. CONCLUSION: The best diagnostic accuracy of cVEMP in SCD patients can be achieved with 2,000-Hz tone burst stimuli, regardless of which metric is used.
Assuntos
Estimulação Acústica/métodos , Doenças do Labirinto/diagnóstico , Canais Semicirculares/fisiopatologia , Potenciais Evocados Miogênicos Vestibulares/fisiologia , Vestíbulo do Labirinto/fisiopatologia , Adulto , Idoso , Audiometria de Tons Puros , Feminino , Humanos , Doenças do Labirinto/fisiopatologia , Masculino , Pessoa de Meia-Idade , Inibição Neural/fisiologia , Estudos Prospectivos , Valores de Referência , Sáculo e Utrículo/fisiopatologia , Espectrografia do Som , Nervo Vestibular/fisiopatologiaRESUMO
OBJECTIVES: Cervical vestibular evoked myogenic potentials (cVEMP) indirectly reveal the response of the saccule to acoustic stimuli through the inhibition of sternocleidomastoid muscle electromyographic response. VEMP inhibition depth (VEMPid) is a recently developed metric that estimates the percentage of saccular inhibition. VEMPid provides both normalization and better accuracy at low response levels than amplitude-normalized cVEMPs. Hopefully, VEMPid will aid in the clinical assessment of patients with vestibulopatholgy. To calculate VEMPid a template is needed. In the original method, a subject's own cVEMP was used as the template, but this method can be problematic in patients who do not have robust cVEMP responses. We hypothesize that a "generic" template, created by assembling cVEMPs from healthy subjects, can be used to compute VEMPid, which would facilitate the use of VEMPid in subjects with pathological conditions. DESIGN: A generic template was created by averaging cVEMP responses from 6 normal subjects. To compare VEMPid calculations using a generic versus a subject-specific template, cVEMPs were obtained in 40 healthy subjects using 500, 750, and 1000 Hz tonebursts at sound levels ranging from 98 to 123 dB peSPL. VEMPids were calculated both with the generic template and with the subject's own template. The ability of both templates to determine whether a cVEMP was present or not was compared with receiver operating characteristic curves. RESULTS: No significant differences were found between VEMPid calculations using a generic template versus using a subject-specific template for all frequencies and sound levels. Based on the receiver operating characteristic curves, the subject-specific and generic template did an equally good job at determining threshold. Within limits, the shape of the generic template did not affect these results. CONCLUSIONS: A generic template can be used instead of a subject-specific template to calculate VEMPid. Compared with cVEMP normalized by electromyographic amplitudes, VEMPid is advantageous because it averages zero when there is no sound stimulus and it allows the accumulating VEMPid value to be shown during data acquisition as a guide to deciding when enough data has been collected.
Assuntos
Sáculo e Utrículo/fisiologia , Potenciais Evocados Miogênicos Vestibulares , Adulto , Análise de Variância , Feminino , Voluntários Saudáveis , Humanos , Masculino , Pessoa de Meia-Idade , Valores de Referência , Doenças Vestibulares/diagnóstico , Adulto JovemRESUMO
The Cogan syndrome is a rare disorder characterized by nonsyphilitic interstitial keratitis and audiovestibular symptoms. Profound sensorineural hearing loss has been reported in approximately half of the patients with the Cogan syndrome resulting in candidacy for cochlear implantation in some patients. The current study is the first histopathologic report on the temporal bones of a patient with the Cogan syndrome who during life underwent bilateral cochlear implantation. Preoperative MRI revealed tissue with high density in the basal turns of both cochleae and both vestibular systems consistent with fibrous tissue due to labyrinthitis. Histopathology demonstrated fibrous tissue and new bone formation within the cochlea and vestibular apparatus, worse on the right. Severe degeneration of the vestibular end organs and new bone formation in the labyrinth were seen more on the right than on the left. Although severe bilateral degeneration of the spiral ganglion neurons was seen, especially on the right, the postoperative word discrimination score was between 50 and 60% bilaterally. Impedance measures were generally higher in the right ear, possibly related to more fibrous tissue and new bone found in the scala tympani on the right side.
Assuntos
Cóclea/patologia , Síndrome de Cogan/patologia , Perda Auditiva Neurossensorial/patologia , Labirintite/patologia , Rampa do Tímpano/patologia , Gânglio Espiral da Cóclea/patologia , Osso Temporal/patologia , Cóclea/cirurgia , Implante Coclear , Síndrome de Cogan/reabilitação , Orelha Interna/patologia , Perda Auditiva Neurossensorial/reabilitação , Humanos , Masculino , Pessoa de Meia-Idade , Gânglio Espiral da Cóclea/citologia , Osso Temporal/cirurgiaRESUMO
BACKGROUND: The cervical vestibular evoked myogenic potential (cVEMP) represents an inhibitory reflex of the saccule measured in the ipsilateral sternocleidomastoid muscle (SCM) in response to acoustic or vibrational stimulation. Since the cVEMP is a modulation of SCM electromyographic (EMG) activity, cVEMP amplitude is proportional to muscle EMG amplitude. We sought to evaluate muscle contraction influences on cVEMP peak-to-peak amplitudes (VEMPpp), normalized cVEMP amplitudes (VEMPn), and inhibition depth (VEMPid). METHODS: cVEMPs at 500 Hz were measured in 25 healthy subjects for 3 SCM EMG contraction ranges: 45-65, 65-105, and 105-500 µV root mean square (r.m.s.). For each range, we measured cVEMP sound level functions (93-123 dB peSPL) and sound off, meaning that muscle contraction was measured without acoustic stimulation. The effect of muscle contraction amplitude on VEMPpp, VEMPn, and VEMPid and the ability to distinguish cVEMP presence/absence were evaluated. RESULTS: VEMPpp amplitudes were significantly greater at higher muscle contractions. In contrast, VEMPn and VEMPid showed no significant effect of muscle contraction. Cohen's d indicated that for all 3 cVEMP metrics contraction amplitude variations produced little change in the ability to distinguish cVEMP presence/absence. VEMPid more clearly indicated saccular output because when no acoustic stimulus was presented the saccular inhibition estimated by VEMPid was zero, unlike those by VEMPpp and VEMPn. CONCLUSION: Muscle contraction amplitude strongly affects VEMPpp amplitude, but contractions 45-300 µV r.m.s. produce stable VEMPn and VEMPid values. Clinically, there may be no need for subjects to exert high contraction effort. This is especially beneficial in patients for whom maintaining high SCM contraction amplitudes is challenging.
Assuntos
Contração Muscular/fisiologia , Músculos do Pescoço/fisiologia , Potenciais Evocados Miogênicos Vestibulares/fisiologia , Estimulação Acústica , Adulto , Idoso , Eletromiografia , Feminino , Voluntários Saudáveis , Humanos , Masculino , Pessoa de Meia-Idade , Adulto JovemRESUMO
OBJECTIVES: The auditory brainstem implant (ABI) provides sound awareness to patients who are ineligible for cochlear implantation. Auditory performance varies widely among similar ABI cohorts. We hypothesize that differences in electrode array position contribute to this variance. Herein, we classify ABI array position based on postoperative imaging and investigate the relationship between position and perception. DESIGN: Retrospective review of pediatric and adult ABI users with postoperative computed tomography. To standardize views across subjects, true axial reformatted series of scans were created using the McRae line. Using multiplanar reconstructions, basion and electrode array tip coordinates and array angles from vertical were measured. From a lateral view, array angles (V) were classified into types I to IV, and from posterior view, array angles (T) were classified into types A to D. Array position was further categorized by measuring distance vertical from basion (D1) and lateral from midline (D2). Differences between array classifications were compared with audiometric thresholds, number of active electrodes, and pitch ranking. RESULTS: Pediatric (n = 4, 2 with revisions) and adult (n = 7) ABI subjects were included in this study. Subjects had a wide variety of ABI array angles, but most were aimed superiorly and posteriorly (type II, n = 7) from lateral view and upright or medially tilted from posterior view (type A, n = 6). Mean pediatric distances were 8 to 42% smaller than adults for D1 and D2. In subjects with perceptual data, electrical thresholds and the number of active electrodes differed among classification types. CONCLUSIONS: In this first study to classify ABI electrode array orientation, array position varied widely. This variability may explain differences in auditory performance.
Assuntos
Implante Auditivo de Tronco Encefálico/métodos , Implantes Auditivos de Tronco Encefálico , Percepção Auditiva , Tronco Encefálico/diagnóstico por imagem , Perda Auditiva Bilateral/reabilitação , Perda Auditiva Neurossensorial/reabilitação , Nervo Vestibulococlear/anormalidades , Adulto , Idoso , Audiometria , Pré-Escolar , Perda Auditiva Bilateral/etiologia , Perda Auditiva Neurossensorial/etiologia , Humanos , Imageamento Tridimensional , Lactente , Pessoa de Meia-Idade , Malformações do Sistema Nervoso/complicações , Neurofibromatose 2/complicações , Período Pós-Operatório , Estudos Retrospectivos , Índice de Gravidade de Doença , Tomografia Computadorizada por Raios X , Adulto JovemRESUMO
OBJECTIVE: The objective is to develop methods to utilize newborn reflectance measures for the identification of middle-ear transient conditions (e.g., middle-ear fluid) during the newborn period and ultimately during the first few months of life. Transient middle-ear conditions are a suspected source of failure to pass a newborn hearing screening. The ability to identify a conductive loss during the screening procedure could enable the referred ear to be either (1) cleared of a middle-ear condition and recommended for more extensive hearing assessment as soon as possible, or (2) suspected of a transient middle-ear condition, and if desired, be rescreened before more extensive hearing assessment. DESIGN: Reflectance measurements are reported from full-term, healthy, newborn babies in which one ear referred and one ear passed an initial auditory brainstem response newborn hearing screening and a subsequent distortion product otoacoustic emission screening on the same day. These same subjects returned for a detailed follow-up evaluation at age 1 month (range 14 to 35 days). In total, measurements were made on 30 subjects who had a unilateral refer near birth (during their first 2 days of life) and bilateral normal hearing at follow-up (about 1 month old). Three specific comparisons were made: (1) Association of ear's state with power reflectance near birth (referred versus passed ear), (2) Changes in power reflectance of normal ears between newborn and 1 month old (maturation effects), and (3) Association of ear's newborn state (referred versus passed) with ear's power reflectance at 1 month. In addition to these measurements, a set of preliminary data selection criteria were developed to ensure that analyzed data were not corrupted by acoustic leaks and other measurement problems. RESULTS: Within 2 days of birth, the power reflectance measured in newborn ears with transient middle-ear conditions (referred newborn hearing screening and passed hearing assessment at age 1 month) was significantly greater than power reflectance on newborn ears that passed the newborn hearing screening across all frequencies (500 to 6000 Hz). Changes in power reflectance in normal ears from newborn to 1 month appear in approximately the 2000 to 5000 Hz range but are not present at other frequencies. The power reflectance at age 1 month does not depend significantly on the ear's state near birth (refer or pass hearing screening) for frequencies above 700 Hz; there might be small differences at lower frequencies. CONCLUSIONS: Power reflectance measurements are significantly different for ears that pass newborn hearing screening and ears that refer with middle-ear transient conditions. At age 1 month, about 90% of ears that referred at birth passed an auditory brainstem response hearing evaluation; within these ears the power reflectance at 1 month did not differ between the ear that initially referred at birth and the ear that passed the hearing screening at birth for frequencies above 700 Hz. This study also proposes a preliminary set of criteria for determining when reflectance measures on young babies are corrupted by acoustic leaks, probes against the ear canal, or other measurement problems. Specifically proposed are "data selection criteria" that depend on the power reflectance, impedance magnitude, and impedance angle. Additional data collected in the future are needed to improve and test these proposed criteria.
Assuntos
Orelha Média/fisiopatologia , Potenciais Evocados Auditivos do Tronco Encefálico/fisiologia , Perda Auditiva Condutiva/fisiopatologia , Emissões Otoacústicas Espontâneas/fisiologia , Feminino , Voluntários Saudáveis , Perda Auditiva Condutiva/diagnóstico , Humanos , Recém-Nascido , Masculino , Triagem NeonatalRESUMO
OBJECTIVES: The primary aim of this study was to compare the perceptual sensation produced by bipolar electrical stimulation of auditory brainstem implant (ABI) electrodes with the morphology of electrically evoked responses elicited by the same bipolar stimulus in the same unanesthetized, postsurgical state. Secondary aims were to (1) examine the relationships between sensations elicited by the bipolar stimulation used for evoked potential recording and the sensations elicited by the monopolar pulse-train stimulation used by the implant processor, and (2) examine the relationships between evoked potential morphology (elicited by bipolar stimulation) to the sensations elicited by monopolar stimulation. DESIGN: Electrically evoked early-latency and middle-latency responses to bipolar, biphasic low-rate pulses were recorded postoperatively in four adults with ABIs. Before recording, the perceptual sensations elicited by these bipolar stimuli were obtained and categorized as (1) auditory sensations only, (2) mixed sensations (both auditory and nonauditory), (3) side effect (nonauditory sensations), or (4) no sensation. In addition, the sensations elicited by monopolar higher-rate pulse-train stimuli similar to that used in processor programming were measured for all electrodes in the ABI array and classified using the same categories. Comparisons were made between evoked response morphology, bipolar stimulation sensation, and monopolar stimulation sensation. RESULTS: Sensations were classified for 33 bipolar pairs as follows: 21 pairs were auditory, 6 were mixed, 5 were side effect, and 1 was no sensation. When these sensations were compared with the electrically evoked response morphology for these signals, P3 of the electrically evoked auditory brainstem response (eABR) and the presence of a middle-latency positive wave, usually between 15 and 25 msec (electrical early middle-latency response [eMLR]), were only present when the perceptual sensation had an auditory component (either auditory or mixed pairs). The presence of other waves in the early-latency response such as N1 or P2 or a positive wave after 4 msec did not distinguish between only auditory or only nonauditory sensations. For monopolar stimulation, 42 were classified as auditory, 16 were mixed, and 26 were classified as side effect or no sensation. When bipolar sensations were compared with monopolar sensations for the 21 bipolar pairs categorized as auditory, 7 pairs had monopolar sensations of auditory for both electrodes, 9 pairs had only one electrode with a monopolar sensation of auditory, with the remainder having neither electrode as auditory. Of 6 bipolar pairs categorized as mixed, 3 had monopolar auditory sensations for one of the electrodes. When monopolar stimulation was compared with evoked potential morphology elicited by bipolar stimulation, P3 and the eMLR were more likely to be present when one or both of the electrodes in the bipolar pair elicited an auditory or mixed sensation with monopolar stimulation and were less likely to occur when neither of the electrodes had an auditory monopolar sensation. Again, other eABR waves did not distinguish between auditory and nonauditory sensations. CONCLUSIONS: ABI electrodes that are associated with auditory sensations elicited by bipolar stimulation are more likely to elicit evoked responses with a P3 wave or a middle-latency wave. P3 of the eABR and M15-25 of the eMLR are less likely to be present if neither electrode of the bipolar pair evoked an auditory sensation with monopolar stimulation.
Assuntos
Implante Auditivo de Tronco Encefálico , Implantes Auditivos de Tronco Encefálico , Potenciais Evocados Auditivos do Tronco Encefálico/fisiologia , Perda Auditiva Central/reabilitação , Neuroma Acústico/cirurgia , Adolescente , Adulto , Nervo Coclear/lesões , Feminino , Perda Auditiva Central/etiologia , Perda Auditiva Central/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Neurofibromatose 2/complicações , Neuroma Acústico/etiologiaRESUMO
OBJECTIVES: Vestibular evoked myogenic potentials (VEMPs) are due to vestibular responses producing brief inhibitions of muscle contractions that are detectable in electromyographic (EMG) responses. VEMP amplitudes are traditionally measured by the peak to peak amplitude of the averaged EMG response (VEMPpp) or by a normalized VEMPpp (nVEMPpp). However, a brief EMG inhibition does not satisfy the statistical assumptions for the average to be the optimal processing strategy. Here, it is postulated that the inhibition depth of motoneuron firing is the desired metric for showing the influence of the vestibular system on the muscle system. The authors present a metric called "VEMPid" that estimates this inhibition depth from the EMG data obtained in a usual VEMP data acquisition. The goal of this article was to compare how well VEMPid, VEMPpp, and nVEMPpp track inhibition depth. DESIGN: To find a robust method to compare VEMPid, VEMPpp, and nVEMPpp, realistic physiological models for the inhibition of VEMP EMG signals were made using VEMP data from four measurement sessions on each of the five normal subjects. Each of the resulting 20 EMG-production models was adjusted to match the EMG autocorrelation of an individual subject and session. Simulated VEMP traces produced by these models were used to compare how well VEMPid, VEMPpp, and nVEMPpp tracked model inhibition depth. RESULTS: Applied to simulated and real VEMP data, VEMPid showed good test-retest consistency and greater sensitivity at low stimulus levels than VEMPpp or nVEMPpp. For large-amplitude responses, nVEMPpp and VEMPid were equivalent in their consistency across subjects and sessions, but for low-amplitude responses, VEMPid was superior. Unnormalized VEMPpp was always worse than nVEMPpp or VEMPid. CONCLUSIONS: VEMPid provides a more reliable measurement of vestibular function at low sound levels than the traditional nVEMPpp, without requiring a change in how VEMP tests are performed. The calculation method for VEMPid should be applicable whenever an ongoing muscle contraction is briefly inhibited by an external stimulus.
Assuntos
Neurônios Motores/fisiologia , Contração Muscular/fisiologia , Músculos do Pescoço/fisiologia , Inibição Neural/fisiologia , Reflexo , Potenciais Evocados Miogênicos Vestibulares/fisiologia , Vestíbulo do Labirinto/fisiologia , Adulto , Simulação por Computador , Eletromiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Adulto JovemRESUMO
Superior canal dehiscence (SCD) is caused by an absence of bony covering of the arcuate eminence or posteromedial aspect of the superior semicircular canal. However, the clinical presentation of SCD syndrome varies considerably, as some SCD patients are asymptomatic and others have auditory and/or vestibular complaints. In order to determine the basis for these observations, we examined the association between SCD length and location with: (1) auditory and vestibular signs and symptoms; (2) air conduction (AC) loss and air-bone gap (ABG) measured by pure-tone audiometric testing, and (3) cervical vestibular-evoked myogenic potential (cVEMP) thresholds. 104 patients (147 ears) underwent SCD length and location measurements using a novel method of measuring bone density along 0.2-mm radial CT sections. We found that patients with auditory symptoms have a larger dehiscence (median length: 4.5 vs. 2.7 mm) with a beginning closer to the ampulla (median location: 4.8 vs. 6.4 mm from ampulla) than patients with no auditory symptoms (only vestibular symptoms). An increase in AC threshold was found as the SCD length increased at 250 Hz (95% CI: 1.7-4.7), 500 Hz (95% CI: 0.7-3.5) and 1,000 Hz (95% CI: 0.0-2.5), and an increase in ABG as the SCD length increased at 250 Hz (95% CI: 2.0-5.3), 500 Hz (95% CI: 1.6-4.6) and 1,000 Hz (95% CI: 1.3-3.3) was also seen. Finally, a larger dehiscence was associated with lowered cVEMP thresholds at 250 Hz (95% CI: -4.4 to -0.3), 500 Hz (95% CI: -4.1 to -1.0), 750 Hz (95% CI: -4.2 to -0.7) and 1,000 Hz (95% CI: -3.6 to -0.5) and a starting location closer to the ampulla at 250 Hz (95% CI: 1.3-5.1), 750 Hz (95% CI: 0.2-3.3) and 1,000 Hz (95% CI: 0.6-3.5). These findings may help to explain the variation of signs and symptoms seen in patients with SCD syndrome.
Assuntos
Otopatias/patologia , Canais Semicirculares/patologia , Potenciais Evocados Miogênicos Vestibulares/fisiologia , Estimulação Acústica , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Audiometria de Tons Puros , Otopatias/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Canais Semicirculares/fisiopatologia , Testes de Função Vestibular , Adulto JovemRESUMO
Halogen bonds are typically observed to have a linear arrangement with a 180° angle between the nucleophile and the halogen bond acceptor X-R. This linearity is commonly explained using the σ-hole model, although there have been alternative explanations involving exchange repulsion forces. We employ two-dimensional Distortion/Interaction and Energy Decomposition Analysis to examine the archetypal H3 Nâ¯X2 halogen bond systems. Our results indicate that although halogen bonds are predominantly electrostatic, their directionality is largely due to decreased Pauli repulsion in linear configurations as opposed to angled ones in the I2 and Br2 systems. As we move to the smaller halogens, Cl2 and F2 , the influence of Pauli repulsion diminishes, and the energy surface is shaped by orbital interactions and electrostatic forces. These results support the role of exchange repulsion forces in influencing the directionality of strong halogen bonds. Additionally, we demonstrate that the 2D Energy Decomposition Analysis is a useful tool for enhancing our understanding of the nature of potential energy surfaces in noncovalent interactions.
RESUMO
OBJECTIVE: To elucidate the differences in auditory performance between auditory brainstem implant (ABI) patients with tumor or nontumor etiologies. DATA SOURCES: PubMed, Embase, and Web of Science Core Collection from 1990 to 2021. REVIEW METHODS: We included published studies with 5 or more pediatric or adult ABI users. Auditory outcomes and side effects were analyzed with weighted means for closed-set, open-set speech, and categories of auditory performance (CAP) scores. Overall performance was compared using an Adult Pediatric Ranked Order Speech Perception (APROSPER) scale created for this study. RESULTS: Thirty-six studies were included and underwent full-text review. Data were extracted for 662 tumor and 267 nontumor patients. 83% were postlingually deafened and 17% were prelingually deafened. Studies that included tumor ABI patients had a weighted mean speech recognition of 39.2% (range: 19.6%-83.3%) for closed-set words, 23.4% (range: 17.2%-37.5%) for open-set words, 21.5% (range: 2.7%-48.4%) for open-set sentences, and 3.1 (range: 1.0-3.2) for CAP scores. Studies including nontumor ABI patients had a weighted mean speech recognition of 79.8% (range: 31.7%-84.4%) for closed-set words, 53.0% (range: 14.6%-72.5%) for open-set sentences, and 2.30 (range: 2.0-4.7) for CAP scores. Mean APROSPER results indicate better auditory performance among nontumor versus tumor patients (3.5 vs 3.0, P = .04). Differences in most common side effects were also observed between tumor and nontumor ABI patients. CONCLUSION: Auditory performance is similar for tumor and nontumor patients for standardized auditory test scores. However, the APROSPER scale demonstrates better ABI performance for nontumor compared to tumor patients.
Assuntos
Implantes Auditivos de Tronco Encefálico , Percepção da Fala , Adulto , Humanos , Surdez/cirurgia , Percepção da Fala/fisiologia , Resultado do Tratamento , CriançaRESUMO
Measurement of bone conduction (BC) hearing thresholds at extended high frequencies (EHF; above 8 kHz) is of clinical interest but is technically complicated by limitations in standard BC transducer output, a lack of calibration standards and sparse clinical data from human subjects. A recently described calibration scheme using an artificial mastoid and interposed accelerometer is applied in this study to characterize and compare acceleration and computed force outputs over the 4-20 kHz range of two standard BC transducers: the RadioEar® B71 and B81, as well as two non-standard, commercially available BC transducers: the Tascam® HP-F200 and the Aftershokz® AS400. Measures of linear output growth, harmonic distortion and acoustic radiation are assessed and compared across devices. A maximum linear input voltage is established for each BC transducer using measurements of linear output growth and total harmonic distortion. At maximum linear input level, the Tascam shows superior force output by 25 to 40 dB above 8 kHz and the widest dynamic EHF range. Acoustic radiation per output force was lowest for the Tascam, whereas the AS400 behaved more like an air conduction earphone than a force generator. In a cohort of 15 normal hearing volunteers, BC thresholds, measured with the Tascam and reported in dB re 1 rms µN, were consistent with historical measures of EHF BC thresholds in similar subjects using an alternative BC transducer.
Assuntos
Audiometria , Condução Óssea , Humanos , Limiar Auditivo , Audição , TransdutoresRESUMO
Pretargeting is a powerful nuclear imaging strategy to achieve enhanced imaging contrast for nanomedicines and reduce the radiation burden to healthy tissue. Pretargeting is based on bioorthogonal chemistry. The most attractive reaction for this purpose is currently the tetrazine ligation, which occurs between trans-cyclooctene (TCO) tags and tetrazines (Tzs). Pretargeted imaging beyond the blood-brain barrier (BBB) is challenging and has not been reported thus far. In this study, we developed Tz imaging agents that are capable of ligating in vivo to targets beyond the BBB. We chose to develop 18F-labeled Tzs as they can be applied to positron emission tomography (PET) - the most powerful molecular imaging technology. Fluorine-18 is an ideal radionuclide for PET due to its almost ideal decay properties. As a non-metal radionuclide, fluorine-18 also allows for development of Tzs with physicochemical properties enabling passive brain diffusion. To develop these imaging agents, we applied a rational drug design approach. This approach was based on estimated and experimentally determined parameters such as the BBB score, pretargeted autoradiography contrast, in vivo brain influx and washout as well as on peripheral metabolism profiles. From 18 initially developed structures, five Tzs were selected to be tested for their in vivo click performance. Whereas all selected structures clicked in vivo to TCO-polymer deposited into the brain, [18F]18 displayed the most favorable characteristics with respect to brain pretargeting. [18F]18 is our lead compound for future pretargeted neuroimaging studies based on BBB-penetrant monoclonal antibodies. Pretargeting beyond the BBB will allow us to image targets in the brain that are currently not imageable, such as soluble oligomers of neurodegeneration biomarker proteins. Imaging of such currently non-imageable targets will allow early diagnosis and personalized treatment monitoring. This in turn will accelerate drug development and greatly benefit patient care.
RESUMO
OBJECTIVE: The aim of this study was to evaluate the hearing outcome of cochlear implantation in patients deafened by Ménière's disease. STUDY DESIGN: Retrospective single-institution study. SETTING: Tertiary medical center. METHODS: Our institutional database of 1400 patients with cochlear implants was reviewed to identify cases with deafness due to Ménière's disease. Twenty-nine patients were identified: 24 with unilateral and 5 with sequential bilateral cochlear implants. Pre- and postoperative speech recognition scores and medical data were extracted from the medical record and analyzed. RESULTS: Overall the mean difference between pre- and postoperative speech recognition after >1 year was 56% (95% CI, 47.08%-64.92%). The mean preoperative monosyllabic word score was 9.5%, and the mean postoperative scores at 1 month, 3 months, 6 months, 1 year, and >1 year were 37.1%, 46.1%, 54.1%, 59.1%, and 66.8%, respectively. Cochlear implantation resulted in improved word scores in all patients regardless of prior medical or surgical treatment (endolymphatic sac, labyrinthectomy). The mean postoperative hearing improvement in patients aged <70 and ≥70 years was 65.26% (95% CI, 54.79%-75.73%) and 40.00% (95% CI, 27.22%-52.77%). Postoperative word scores in patients with bilateral cochlear implants were not significantly different between the first and second implanted ears or between the monoaural and binaural testing conditions. CONCLUSION: Cochlear implant in patients deafened by Ménière's disease significantly improves word recognition scores regardless of whether medical or surgical treatment is used prior to implantation. The potential improvement in word recognition scores decreases after age 70 years.
Assuntos
Implante Coclear , Implantes Cocleares , Saco Endolinfático , Perda Auditiva Neurossensorial , Doença de Meniere , Percepção da Fala , Implante Coclear/métodos , Audição , Perda Auditiva Neurossensorial/cirurgia , Humanos , Doença de Meniere/complicações , Doença de Meniere/cirurgia , Estudos Retrospectivos , Resultado do TratamentoRESUMO
PURPOSE: Characterizing and comparing speech recognition development in children with cochlear implants (CIs) is challenging because of variations in test type. This retrospective cohort study modified the Pediatric Ranked Order Speech Perception (PROSPER) scoring system to (a) longitudinally analyze the speech perception of children with CIs and (b) examine the role of age at CI activation, listening mode (i.e., unilateral or bilateral implantation), and interimplant interval. METHOD: Postimplantation speech recognition scores from 31 children with prelingual, severe-to-profound hearing loss who received CIs were analyzed (12 with unilateral CI [UniCI], 13 with sequential bilateral CIs [SEQ BiCIs], and six with simultaneous BiCIs). Data were extracted from the Massachusetts Eye and Ear Audiology database. A version of the PROSPER score was modified to integrate the varying test types by mapping raw scores from different tests into a single score. The PROSPER scores were used to construct speech recognition growth curves of the implanted ears, which were characterized by the slope of the growth phase, the time from activation to the plateau onset, and the score at the plateau. RESULTS: While speech recognition improved considerably for children following implantation, the growth rates and scores at the plateau were highly variable. In first implanted ears, later implantation was associated with poorer scores at the plateau (ß = -0.15, p = .01), but not growth rate. The first implanted ears of children with BiCIs had better scores at the plateau than those with UniCI (ß = 0.59, p = .02). Shorter interimplant intervals in children with SEQ BiCIs promoted faster speech recognition growth of the first implanted ears. CONCLUSION: The modified PROSPER score could be used clinically to track speech recognition development in children with CIs, to assess influencing factors, and to assist in developing and evaluating patient-specific intervention strategies. SUPPLEMENTAL MATERIAL: https://doi.org/10.23641/asha.20113538.