1.
Radiology ; 264(1): 119-25, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22570506

RESUMO

PURPOSE: To retrospectively determine which features of urinary calculi are associated with their detection after virtual elimination of contrast medium at dual-energy computed tomographic (CT) urography by using a novel tin filter. MATERIALS AND METHODS: The institutional ethics committee approved this retrospective study, with waiver of informed consent. A total of 152 patients were examined with single-energy nonenhanced CT and dual-energy CT urography in the excretory phase (either 140 and 80 kV [n=44] or 140 and 100 kV [n=108], with tin filtration at 140 kV). The contrast medium in the renal pelvis and ureters was virtually removed from excretory phase images by using postprocessing software, resulting in virtual nonenhanced (VNE) images. The sensitivity regarding the detection of calculi on VNE images compared with true nonenhanced (TNE) images was determined, and interrater agreement was evaluated by using the Cohen k test. By using logistic regression, the influences of image noise, attenuation, and stone size, as well as attenuation of the contrast medium, on the stone detection rate were assessed. Threshold values with maximal sensitivity and specificity were calculated by means of receiver operating characteristic analyses. RESULTS: Eighty-seven stones were detected on TNE images; 46 calculi were identified on VNE images (sensitivity, 52.9%). Interrater agreement revealed a κ value of 0.95 with TNE images and 0.91 with VNE data. Size (long-axis diameter, P=.005; short-axis diameter, P=.041) and attenuation (P=.0005) of the calculi and image noise (P=.0031) were significantly associated with the detection rate on VNE images. As threshold values, size larger than 2.9 mm, maximum attenuation of the calculi greater than 387 HU, and image noise less than 20 HU were found. CONCLUSION: After virtual elimination of contrast medium, large (>2.9 mm) and high-attenuation (>387 HU) calculi can be detected with good reliability; smaller and lower attenuation calculi might be erased from images, especially with increased image noise.


Assuntos
Tomografia Computadorizada por Raios X/métodos , Cálculos Urinários/diagnóstico por imagem , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Meios de Contraste , Feminino , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Curva ROC , Interpretação de Imagem Radiográfica Assistida por Computador , Estudos Retrospectivos , Sensibilidade e Especificidade , Ácidos Tri-Iodobenzoicos , Urografia
2.
J Digit Imaging ; 25(2): 250-7, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21786073

RESUMO

The purpose of this study was to evaluate the influence of advanced software assistance on the assessment of carotid artery stenosis; particularly, the inter-observer variability of readers with different level of experience is to be investigated. Forty patients with suspected carotid artery stenosis received head and neck dual-energy CT angiography as part of their pre-interventional workup. Four blinded readers with different levels of experience performed standard imaging interpretation. At least 1 day later, they performed quantification using an advanced vessel analysis software including automatic dual-energy bone and hard plaque removal, automatic and semiautomatic vessel segmentation, as well as creation of curved planar reformation. Results were evaluated for the reproducibility of stenosis quantification of different readers by calculating the kappa and correlation values. Consensus reading of the two most experienced readers was used as the standard of reference. For standard imaging interpretation, experienced readers reached very good (k = 0.85) and good (k = 0.78) inter-observer variability. Inexperienced readers achieved moderate (k = 0.6) and fair (k = 0.24) results. Sensitivity values 80%, 91%, 83%, 77% and specificity values 100%, 84%, 82%, 53% were achieved for significant area stenosis >70%. For grading using advanced vessel analysis software, all readers achieved good inter-observer variability (k = 0.77, 0.72, 0.71, and 0.77). Specificity values of 97%, 95%, 95%, 93% and sensitivity values of 84%, 78%, 86%, 92% were achieved. In conclusion, when supported by advanced vessel analysis software, experienced readers are able to achieve good reproducibility. Even inexperienced readers are able to achieve good results in the assessment of carotid artery stenosis when using advanced vessel analysis software.


Assuntos
Angiografia/métodos , Estenose das Carótidas/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Meios de Contraste , Humanos , Imageamento Tridimensional/métodos , Iopamidol/análogos & derivados , Interpretação de Imagem Radiográfica Assistida por Computador , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Software , Interface Usuário-Computador
3.
Acta Radiol ; 52(7): 762-6, 2011 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-21498316

RESUMO

BACKGROUND: CT has become an important role in the differential diagnosis of acute chest pain to exclude an aortic dissection, pulmonary embolism and acute coronary artery syndrome. However, the additional radiation exposure is a cause of concern and dose saving strategies should be applied, if possible. PURPOSE: To estimate effective dose of retrospective gated and prospective ECG-triggered triple-rule-out computed tomography angiography (TRO-CTA). MATERIAL AND METHODS: An Alderson-Rando-phantom equipped with thermoluminescent dosimeters was used for dose measurements. Exposure was performed on a 128-slice single source scanner. The following scan parameters were used (retrospective ECG-gated): 120 kV, 190 mAs/rot., collimation 128x0.6 mm, rotation time 0.3 s. Protocols with a simulated heart rate (HR) of 60 and 100 bpm were performed using the standard ECG-pulsing as well as MinDose. Additionally, a prospective triggered TRO-CTA was acquired (HR 60 bpm). RESULTS: The estimated effective dose of retrospective ECG-gated TRO-CTA ranged from 7.4-13.4 mSv and from 10.1-17.5 mSv for men and women, respectively. Due to radiosensitive breast tissue, women received a significant increased effective dose of up to 64.7% ± 0.03% (p = 0.028) compared to men. MinDose reduces radiation exposure of up to 33.0% ± 6.5% in comparison to standard ECG-pulsing (p < 0.001). The effective dose increased significantly with lower heart rates (p < 0.001). Prospective ECG-triggered TRO-CTA showed an effective dose of 5.9 mSv and 8.2 mSv for men and women, respectively. Compared to retrospective ECG-gated TRO-CTA a significant dose reduction was observed (p < 0.001). CONCLUSION: Due to the significant different dose exposure, scan protocols should be specifically adapted in a patient- and problem-oriented manner.


Assuntos
Técnicas de Imagem de Sincronização Cardíaca/métodos , Angiografia Coronária/métodos , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos , Feminino , Humanos , Masculino , Imagens de Fantasmas , Estatísticas não Paramétricas , Dosimetria Termoluminescente
4.
Oncol Res Treat ; 44(7-8): 400-407, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34102639

RESUMO

INTRODUCTION: Addition of cyclin-dependent 4/6 kinase (CDK4/6) inhibitors to endocrine therapy is standard of care in the treatment of women with advanced hormone receptor-positive HER2-negative breast cancer. However, the predictive factors for the treatment response to CDK4/6 inhibitor therapy are poorly elucidated. Early changes in the by [18F]-fluorodeoxyglucose positron emission tomography (FDG-PET) uptake of tumors receiving different kinds of therapy have proven to reliably predict treatment outcomes in a variety of malignancies. Therefore, the feasibility of early metabolic response assessment to predict the long-term treatment response to CDK4/6 inhibitor therapy was evaluated in the present study. METHODS: Eight patients underwent FDG-PET/CT before and after the initiation of CDK4/6 inhibitor therapy (ribociclib, palbociclib or abemcaciclib). CDK4/6 inhibitor therapy was combined with either aromatase inhibition or fulvestrant. The median interval between the treatment start (including baseline PET) and the follow-up PET examination was 14 days. Conventional radiographic staging was performed 3 months after the start of CDK4/6 inhibitor therapy. The percentual changes in molecular tumor volume, SUVpeak, the summed SUVpeak of up to 5 metastases (PERCIST-5), and total lesion glycolysis (TLG) were calculated for each patient. RESULTS: Three patients showed progressive disease after 3 months of CDK4/6 inhibitor therapy, whereas 5 patients showed disease control (3 stable disease and 2 partial remission). Disease control was maintained in these patients (follow-up range 7-22 months). Patients with disease control had a significantly greater decline in TLG (-55.3 vs. 16.7%; p < 0.05). The same was true for the PERCIST-5 (-21.9 vs. 11.3%, p < 0.05). All patients with progressive TLG showed treatment failure and/or a poor outcome. CONCLUSION: Elevated TLG on early FDG-PET seems to be associated with long-term treatment failure and a poor outcome in patients undergoing CDK4/6 inhibitor therapy for metastatic breast cancer. Early findings indicate a potential prognostic value of early FDG-PET in this setting and warrant a prospective evaluation.


Assuntos
Neoplasias da Mama , Inibidores de Proteínas Quinases/uso terapêutico , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/tratamento farmacológico , Quinase 4 Dependente de Ciclina , Quinase 6 Dependente de Ciclina , Ciclinas , Feminino , Fluordesoxiglucose F18 , Hormônios , Humanos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Tomografia por Emissão de Pósitrons , Prognóstico , Estudos Prospectivos , Compostos Radiofarmacêuticos
5.
Radiology ; 257(2): 402-9, 2010 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-20807847

RESUMO

PURPOSE: To retrospectively evaluate radiation dose, image quality, and the ability to differentiate urinary calculi of differing compositions by using low-dose dual-energy computed tomography (CT). MATERIALS AND METHODS: The institutional review board approved this retrospective study; informed consent was waived. A low-dose dual-energy CT protocol (tube voltage and reference effective tube current-time product, 140 kV and 23 mAs and 80 kV and 105 mAs; collimation, 64 × 0.6 mm; pitch, 0.7) for the detection of urinary calculi was implemented into routine clinical care. All patients (n = 112) who were examined with this protocol from July 2008 to August 2009 were included. The composition of urinary calculi was assessed by using commercially available postprocessing software and was compared with results of the reference standard (ex vivo infrared spectroscopy) in 40 patients for whom the reference standard was available. Effective doses were calculated. Image quality was rated subjectively and objectively and was correlated with patient size expressed as body cross-sectional area at the level of acquisition by using Spearman correlation coefficients. RESULTS: One calcified concrement in the distal ureter of an obese patient was mistakenly interpreted as mixed calcified and uric acid. One struvite calculus was falsely interpreted as cystine. All other uric acid, cystine, and calcium-containing calculi were correctly identified by using dual-energy CT. The mean radiation dose was 2.7 mSv. The average image quality was rated as acceptable, with a decrease in image quality in larger patients. CONCLUSION: Low-dose unenhanced dual-source dual-energy CT can help differentiate between calcified, uric acid, and cystine calculi at a radiation dose comparable to that of conventional intravenous pyelography. Because of decreased image quality in obese patients, only nonobese patients should be examined with this protocol.


Assuntos
Tomografia Computadorizada por Raios X/métodos , Cálculos Urinários/química , Cálculos Urinários/diagnóstico por imagem , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Diagnóstico Diferencial , Erros de Diagnóstico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador , Estudos Retrospectivos , Sensibilidade e Especificidade , Urografia
6.
AJR Am J Roentgenol ; 194(6): 1590-5, 2010 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-20489101

RESUMO

OBJECTIVE: Dual-energy CT has the potential to automatically remove calcified plaques from angiographic data sets. The objective of this study is to compare the accuracy of visual grading of stenoses after plaque removal with visual grading in standard reconstructions. Digital subtraction angiography (DSA) was used as a reference standard. SUBJECTS AND METHODS: Twenty-five patients underwent dual-energy CT (140 kV and 80 mAs; 80 kV and 234 mAs) angiography and DSA. Plaque and bone removal was performed. Twenty-nine calcified stenoses were quantified using standard reconstructions, plaque and bone removal maximum intensity projections after plaque and bone removal, and DSA images, according to the North American Symptomatic Carotid Endarterectomy Trial criteria. The accuracy of the detection of relevant stenoses (> 70%) and occlusions was assessed. Correlation coefficients of the grades of stenoses with DSA were calculated. The influence of vessel enhancement on the accuracy of plaque removal was analyzed. RESULTS: The average postprocessing time was 45 seconds. After plaque removal, all 25 relevant and four nonrelevant stenoses were correctly detected. Six relevant stenoses were overestimated as complete occlusions. With the standard reconstructions, two nonrelevant stenoses were overestimated as relevant. Correlation coefficients (r(2)) for the grading of stenoses after plaque removal and with standard reconstructions versus DSA were 0.7694 and 0.4329, respectively. Vessel contrast enhancement correlated weakly (r(2) = 0.2072) with the accuracy of plaque removal. CONCLUSION: Dual-energy CT with plaque removal automatically delivers CT luminograms with a high sensitivity for the detection of relevant stenoses and a higher correlation to DSA than standard reconstructions but frequently leads to an overestimation of high-grade stenoses as occlusions. Thus, dual-energy CT plaque and bone removal should be used complementary to standard reconstructions, and not exclusively.


Assuntos
Angiografia Digital/métodos , Estenose das Carótidas/diagnóstico por imagem , Angiografia Cerebral/métodos , Crânio/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Idoso , Idoso de 80 Anos ou mais , Calcinose/diagnóstico por imagem , Calcinose/cirurgia , Estenose das Carótidas/cirurgia , Endarterectomia das Carótidas , Feminino , Humanos , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Intensificação de Imagem Radiográfica/métodos , Interpretação de Imagem Radiográfica Assistida por Computador , Crânio/cirurgia , Resultado do Tratamento
7.
J Comput Assist Tomogr ; 34(2): 309-15, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-20351526

RESUMO

OBJECTIVE: To assess dose and image quality of dual-energy (DE) mixed images in comparison to single-energy (SE) images. METHODS: A phantom containing iodine contrast inserts was scanned using SE and DE protocols. Dual-energy mixed images were reconstructed with varying composition ratios (ratio describing the contribution of 80 and 140 data in the mixed images). Image noise, iodine contrast, and contrast-to-noise ratios (CNRs) were assessed inside and outside the central field of view (FoV). RESULTS: With the default composition ratio (0.3), noise and contrast were comparable between both protocols in the central FoV. Peripherally, DE image noise exceeded noise in SE images; CNR in the periphery was lower in the DE images. The highest CNR was found for a composition ratio of 0.5 to 0.9, exceeding the CNR of SE images. CONCLUSIONS: Dual-energy mixed images offer an image quality comparable to SE images within the central FoV at comparable dose levels. In the peripheral FoV, image quality is decreased. By optimizing the composition ratio in the DE mixed images, higher CNRs than in the SE images can be achieved, leading to a dose reduction potential.


Assuntos
Doses de Radiação , Tomografia Computadorizada por Raios X/métodos , Meios de Contraste , Processamento de Imagem Assistida por Computador/métodos , Iohexol/análogos & derivados , Modelos Lineares , Imagens de Fantasmas , Controle de Qualidade
8.
Heart Vessels ; 25(1): 57-62, 2010 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-20091400

RESUMO

This study assesses the global left ventricular function and volumes using dual-source computed tomography (DSCT) with improved temporal resolution (83 ms) by use of a semi-automatic software tool in comparison to invasive angiography (IVA). One hundred patients scheduled for invasive coronary angiography because of suspected or known coronary artery disease (80 men; 20 women, mean age 62 +/- 10 years) were additionally examined by DSCT. Global left ventricular function (LVF), left ventricular end-diastolic volume (LVEDV), end-systolic volume (LVESV), and stroke volume (SV) were calculated by the use of semi-automatic post-processing software and results compared with those of IVA. Bland-Altman analysis revealed a good concordance between DSCT and IVA in terms of LVF: Pearson's r 0.78, confidence interval [CI] 0.68-0.86, P < 0.0001, bias 7.1% +/- 9.1%. The same was true for LVESV (Pearson's r 0.78, CI 0.67-0.85, P < 0.0001, bias 15.0 +/- 21.0 ml), whereas the agreement for LVEDV and SV was only moderate (LVEDV: Pearson's r 0.59, CI 0.43-0.72, P < 0.0001, bias 13.0 +/- 18.1 ml; SV: Pearson's r 0.47, CI 0.28-0.62, P < 0.0001, bias -1.4 +/- 28.4 ml). Semi-automatic evaluation of left ventricular parameters with DSCT revealed good correlation for LVF and LVESV, whereas LVEDV and SV showed only a moderate correlation. Moreover, LVF is systematically underestimated by DSCT.


Assuntos
Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Volume Sistólico , Disfunção Ventricular Esquerda/diagnóstico por imagem , Função Ventricular Esquerda , Idoso , Automação Laboratorial , Doença da Artéria Coronariana/complicações , Doença da Artéria Coronariana/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Tomografia Computadorizada por Raios X , Disfunção Ventricular Esquerda/etiologia , Disfunção Ventricular Esquerda/fisiopatologia
9.
Eur Radiol ; 19(3): 584-90, 2009 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-18953544

RESUMO

Multi-slice computed tomography (MSCT) is a non-invasive modality to visualize coronary arteries with an overall good image quality. Improved spatial and temporal resolution of 64-slice and dual-source computed tomography (DSCT) scanners are supposed to have a positive impact on diagnostic accuracy and image quality. However, quantitative parameters to compare image quality of 16-slice, 64-slice MSCT and DSCT are missing. A total of 256 CT examinations were evaluated (Siemens, Sensation 16: n = 90; Siemens Sensation 64: n = 91; Siemens Definition: n = 75). Mean Hounsfield units (HU) were measured in the cavum of the left ventricle (LV), the ascending aorta (Ao), the left ventricular myocardium (My) and the proximal part of the left main (LM), the left anterior descending artery (LAD), the right coronary artery (RCA) and the circumflex artery (CX). Moreover, the ratio of intraluminal attenuation (HU) to myocardial attenuation was assessed for all coronary arteries. Clinical data [body mass index (BMI), gender, heart rate] were accessible for all patients. Mean attenuation (CA) of the coronary arteries was significantly higher for DSCT in comparison to 64- and 16-slice MSCT within the RCA [347 +/- 13 vs. 254 +/- 14 (64-MSCT) vs. 233 +/- 11 (16-MSCT) HU], LM (362 +/- 11/275 +/- 12/262 +/- 9), LAD (332 +/- 17/248 +/- 19/219 +/- 14) and LCX (310 +/- 12/210 +/- 13/221 +/- 10, all p < 0.05), whereas there was no significant difference between DSCT and 64-MSCT for the LV, the Ao and My. Heart rate had a significant impact on CA ratio in 16-slice and 64-slice CT only (p < 0.05). BMI had no impact on the CA ratio in DSCT only (p < 0.001). Improved spatial and temporal resolution of dual-source CT is associated with better opacification of the coronary arteries and a better contrast with the myocardium, which is independent of heart rate. In comparison to MSCT, opacification of the coronary arteries at DSCT is not affected by BMI. The main advantage of DSCT lies with the heart rate independency, which might have a positive impact on the diagnostic accuracy.


Assuntos
Angiografia Coronária/métodos , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Cálcio/metabolismo , Feminino , Frequência Cardíaca , Humanos , Processamento de Imagem Assistida por Computador/métodos , Masculino , Análise Multivariada , Miocárdio/patologia , Estudos Retrospectivos
10.
Eur Radiol ; 19(1): 37-41, 2009 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-18648818

RESUMO

The aim of the study was to evaluate radiation exposure of a chest pain protocol with ECG-gated dual-source computed tomography (DSCT). An Alderson Rando phantom equipped with thermoluminescent dosimeters was used for dose measurements. Exposure was performed on a dual-source computed tomography system with a standard protocol for chest pain evaluation (120 kV, 320 mAs/rot) with different simulated heart rates (HRs). The dose of a standard chest CT examination (120 kV, 160 mAs) was also measured. Effective dose of the chest pain protocol was 19.3/21.9 mSv (male/female, HR 60), 17.9/20.4 mSv (male/female, HR 80) and 14.7/16.7 mSv (male/female, HR 100). Effective dose of a standard chest examination was 6.3 mSv (males) and 7.2 mSv (females). Radiation dose of the chest pain protocol increases significantly with a lower heart rate for both males (p = 0.040) and females (p = 0.044). The average radiation dose of a standard chest CT examination is about 36.5% that of a CT examination performed for chest pain. Using DSCT, the evaluated chest pain protocol revealed a higher radiation exposure compared with standard chest CT. Furthermore, HRs markedly influenced the dose exposure when using the ECG-gated chest pain protocol.


Assuntos
Carga Corporal (Radioterapia) , Técnicas de Imagem de Sincronização Cardíaca , Dor no Peito/diagnóstico por imagem , Eficiência Biológica Relativa , Dosimetria Termoluminescente , Tomografia Computadorizada por Raios X/métodos , Humanos , Imagens de Fantasmas , Doses de Radiação , Tomografia Computadorizada por Raios X/instrumentação
11.
Radiology ; 247(2): 346-55, 2008 May.
Artigo em Inglês | MEDLINE | ID: mdl-18372455

RESUMO

PURPOSE: To prospectively evaluate the effect of heart rate, heart rate variability, and calcification on dual-source computed tomography (CT) image quality and to prospectively assess diagnostic accuracy of dual-source CT for coronary artery stenosis, by using invasive coronary angiography as the reference standard. MATERIALS AND METHODS: This study had local Ethics Committee approval; all patients gave informed consent. Patients who underwent bypass surgery were excluded; patients with coronary artery stent-grafts were included. One hundred patients (20 women, 80 men; mean age, 62 years +/- 10 [standard deviation]) known to have or suspected of having coronary artery disease underwent dual-source CT and invasive coronary angiography. Image quality was assessed. Accuracy of dual-source CT in depiction or exclusion of significant stenosis (>or=50%) was evaluated on a per-segment and per-patient basis. Effects of heart rate, heart rate variability, and calcification on image quality and accuracy were analyzed by using multivariate regression and were analyzed between subgroups of predictor variables. Simple regression was performed to calculate thresholds for adequate image quality. RESULTS: Mean heart rate was 64.9 beats per minute +/- 13.2, mean variability was 23.6 beats per CT examination +/- 36.2, and mean Agatston score was 786.5 +/- 965.9. Diagnostic image quality was obtained in 90.2% of segments. Sensitivity, specificity, and positive and negative predictive values for the presence of significant stenosis were, respectively, 91.1%, 92.0%, 75.4%, and 97.5% by segment and 100%, 81.5%, 93.6%, and 100% by patient. Image quality was significantly related to heart rate variability (P = .015) and calcification (P < .001); the number of nondiagnostic segments was significantly affected by calcification only. Calcification was the single factor with significant impact on diagnostic accuracy (P = .001). CONCLUSION: While dual-source CT resulted in heart-rate independent image quality, image quality remained prone to heart rate variability and calcification.


Assuntos
Calcinose/diagnóstico por imagem , Estenose Coronária/diagnóstico por imagem , Frequência Cardíaca/fisiologia , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Calcinose/fisiopatologia , Meios de Contraste , Angiografia Coronária , Estenose Coronária/fisiopatologia , Feminino , Humanos , Iopamidol/análogos & derivados , Dinitrato de Isossorbida/administração & dosagem , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Interpretação de Imagem Radiográfica Assistida por Computador , Análise de Regressão , Sensibilidade e Especificidade , Vasodilatadores/administração & dosagem
12.
Eur J Radiol ; 66(1): 127-33, 2008 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-17851011

RESUMO

AIMS: Detecting stenoses of coronary arteries with multidetector row computer tomography (MDCT) is a well feasible non-invasive method. However, there is still the problem of deciding whether a stenosis is hemodynamically relevant or not. Objective of the present study was to validate the feasibility of a low dose protocol for MDCT using 80 kV for detecting late enhancement. METHODS AND RESULTS: Using a Alderson-Rando Phantom evaluation of the effective dose of this LE protocol was performed. Ten patients (six male, four female, mean age 61) with known coronary artery disease and scheduled for a conventional coronary angiogram in our facility were subsequently recruited. All patients underwent CT-angiography (CTA) 1 day prior to magnetic resonance imaging. Five minutes after the application of 100ml contrast agent for the CTA scan, a low dose late enhancement scan (80 kV, 400 mA s maximum, ECG pulsed scan, 64 mm x 0.6mm collimation, 0.33 s tube rotation) was performed. Phantom dose measurements showed an effective dose for this protocol of 1.19 mSv (male) and 1.61 mSv (female). Fifty-six percent (5/9) of the patients showed a late enhancement on the MRI scan. Three transmural late enhancements and all four negative findings were correctly identified by CT. This represents a sensitivity of 78% (3/5), specificity of 100% (3/3), NPV of 100% (4/4) and a PPV of 97%. CONCLUSION: We were able to show that the low dose protocol is feasible and, furthermore, preliminary results look promising.


Assuntos
Estenose Coronária/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Meios de Contraste , Angiografia Coronária , Estudos de Viabilidade , Feminino , Gadolínio DTPA , Humanos , Iopamidol/análogos & derivados , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas , Valor Preditivo dos Testes , Sensibilidade e Especificidade
13.
Am J Cardiol ; 100(4): 587-92, 2007 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-17697811

RESUMO

The aim of the present study was to evaluate the diagnostic accuracy of a new dual-source computed tomographic scanner generation with 83-ms temporal resolution in cardiac imaging. Fifty-one unselected consecutive patients (mean age 64 +/- 10 years) scheduled for invasive coronary angiography because of suspected or known coronary artery disease (CAD) were examined with dual-source computed tomography (DSCT). All coronary segments were analyzed regarding the presence of coronary artery lesions. The findings were compared with invasive coronary angiography. During computed tomographic examination, mean heart rate was 65 +/- 14 beats/min. Thirteen of 51 patients (25%) did not have sinus rhythm. Mean Agatston score equivalent was 779 (median 358, range 0 to 3,898). Prevalence of CAD was 75%. Based on a coronary segment model, sensitivity was 96%, specificity 87%, positive predictive value 61%, and negative predictive value 99% for the detection of significant lesions (> or =50% diameter stenosis). The main reason for false-positive results was an overestimation of mild lesions by DSCT. In conclusion, our initial data indicate that DSCT allows a high accuracy to exclude relevant coronary stenosis in unselected patients with a high prevalence of CAD and a relevant number with heart rhythm irregularities. However, overestimation of stenosis, especially in cases of calcifications, is still a limitation.


Assuntos
Angiografia Coronária/métodos , Doença das Coronárias , Tomografia Computadorizada por Raios X , Idoso , Doença das Coronárias/diagnóstico por imagem , Doença das Coronárias/epidemiologia , Doença das Coronárias/fisiopatologia , Eletrocardiografia , Feminino , Alemanha/epidemiologia , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Prevalência , Prognóstico , Reprodutibilidade dos Testes , Índice de Gravidade de Doença
14.
Invest Radiol ; 42(3): 189-95, 2007 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-17287649

RESUMO

PURPOSE: Multislice detector computed tomography (MSCT) is an accurate noninvasive modality to detect and classify different stages of atherosclerosis. The aim of the New Age II Study was to detect coronary lesions in men without established coronary artery disease (CAD) but with a distinct cardiovascular risk profile. We also sought to assess the effect after 1 year of a lipid-lowering therapy (LLT) using 20 mg of atorvastatin. METHODS: Forty-sixe male patients (mean, 61 +/- 10 years) with an elevated risk for CAD (PROCAM score >3 quintile) without LLT were included. Native and contrast-enhanced scans were performed in all patients. A total of 27 of 46 patients received a follow-up scan (after 488 +/- 138 days). Coronary plaque burden (CPB) was assessed volumetrically. RESULTS: The prevalence of CAD was 83% (38/46 patients), and 11% (5/46) without coronary calcifications still had noncalcified plaques. Total cholesterol and low-density lipoprotein cholesterol levels decreased significantly under LLT (225 +/- 41 mg/dL vs. 162 +/- 37 mg/dL, P < 0.0001 and 148 +/- 7 mg/dL vs. 88 +/- 5 mg/dL, P < 0.001, respectively). On follow-up, calcium score and CPB remained unchanged (Agatston score: 261 +/- 301 vs. 282 +/- 360; CPB: 0.149 +/- 0.108 vs. 0.128 +/- 0.075 mL, P > 0.05), whereas mean plaque volume of noncalcified plaques decreased significantly from 0.042 +/- 0.029 mL versus 0.030 +/- 0.014 mL (P < 0.05, mean reduction 0.012 +/- 0.017 mL or 24 +/- 13%). CONCLUSIONS: Statin therapy led to a significant reduction of noncalcified plaque burden that was not reflected in calcium scoring or total plaque burden. This finding might explain the risk reduction after the initiation of statin therapy. Using multislice detector computed tomography, physicians have the potential to monitor medical treatment in patients with coronary atherosclerosis.


Assuntos
Calcinose/tratamento farmacológico , Doença da Artéria Coronariana/tratamento farmacológico , Vasos Coronários/patologia , Inibidores de Hidroximetilglutaril-CoA Redutases/uso terapêutico , Hipolipemiantes/uso terapêutico , Adulto , Idoso , Doença da Artéria Coronariana/patologia , Humanos , Inibidores de Hidroximetilglutaril-CoA Redutases/farmacologia , Hipolipemiantes/farmacologia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Fatores de Risco , Tomografia Computadorizada por Raios X
15.
Invest Radiol ; 42(3): 196-203, 2007 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-17287650

RESUMO

OBJECTIVES: The aim of this study was to quantify image quality gains of a moving coronary plaque phantom using dual-source computed tomography (DSCT) providing 83 milliseconds temporal resolution in direct comparison to 64 slice single-source multidetector CT (MDCT) with a temporal resolution of 165 milliseconds. MATERIALS AND METHODS: Three cardiac vessel phantoms with fixed 50% stenosis and changing plaque configurations were mounted on a moving device simulating cardiac motion. Scans were performed at a simulated heart frequency of 60 to 120 bpm. Image quality assessment was performed in different anatomic orientations inside a thoracic phantom. RESULTS: A significant improvement of image quality using the DSCT could be found (P=0.0002). Relevant factors influencing image quality aside from frequency (P=0.0002) are plaque composition (P<0.0001), as well as orientation (P<0.0001). CONCLUSION: Scanning with 83 milliseconds temporal resolution improved image quality of coronary plaque at higher heart frequencies.


Assuntos
Angiografia Coronária/instrumentação , Doença da Artéria Coronariana/diagnóstico por imagem , Tomografia Computadorizada por Raios X/instrumentação , Algoritmos , Angiografia Coronária/métodos , Doença da Artéria Coronariana/patologia , Humanos , Processamento de Imagem Assistida por Computador , Imagens de Fantasmas , Intensificação de Imagem Radiográfica , Fatores de Tempo , Tomografia Computadorizada por Raios X/métodos
16.
AJR Am J Roentgenol ; 189(5): 1064-70, 2007 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-17954641

RESUMO

OBJECTIVE: Functional analysis using MDCT has been limited by insufficient temporal resolution. The aim of this study was to assess the performance of a dual-source CT system with improved temporal resolution in the determination of both volume- or time-dependent functional parameters and regional wall motion in comparison with cine MRI. SUBJECTS AND METHODS: Twenty patients (15 of whom had previous myocardial infarction) were prospectively examined using dual-source CT. MRI was used as the standard of reference. Using the Simpson's method, ventricular volumes were determined for the whole of the cardiac cycle and results compared using Parson's correlation and Bland-Altman analysis. Regional wall motion was assessed on cine images and compared using weighted kappa statistics. RESULTS: Dual-source CT revealed a strong correlation with cine MRI regarding the quantification of end-diastolic volume (r = 0.98), end-systolic volume (r = 0.99), stroke volume (r = 0.96), and ejection fraction (r = 0.95). Good correlation was obtained for peak ejection rate (r = 0.79) and peak filling rate (r = 0.84), whereas agreement proved only moderate for time-to-peak ejection rate (r = 0.68) or time-to-peak filling rate from end-systole (r = 0.64). The mean difference for ejection fraction was negligible (bias, 0.72%). Good agreement between both techniques was likewise found for regional wall motion (kappa = 0.88). CONCLUSION: With the improvement of temporal resolution between 42 and 83 milliseconds, dual-source CT not only enables accurate assessment of global functional parameters, but it also allows for quantification of time-dependent variables and reliable evaluation of regional wall motion.


Assuntos
Intensificação de Imagem Radiográfica/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Disfunção Ventricular Esquerda/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Intensificação de Imagem Radiográfica/instrumentação , Interpretação de Imagem Radiográfica Assistida por Computador/instrumentação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X/instrumentação
17.
J Diabetes Complications ; 21(2): 69-74, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17331854

RESUMO

BACKGROUND: Diabetes mellitus is an important risk factor for coronary artery disease. Cardiac multislice computed tomography (MSCT) permits visualization of the coronary arteries with good sensitivity and specificity. However, at present, there are no data whether MSCT allows an accurate assessment of coronary arteries of diabetic patients, in comparison to nondiabetic patients. Thus, we compared the catheter-controlled MSCT results from diabetic and nondiabetic patients in a cohort of 116 patients with regard to sensitivity, specificity, positive predictive value, and negative predictive value, as well as image quality. METHODS AND MATERIALS: Twenty-two diabetic patients (age, 64.6+/-8.5 years; number of risk factors, 3.4+/-1.1) and 94 nondiabetic patients (age, 64.2+/-9.2 years; number of risk factors, 2.4+/-1.0) were examined by MSCT (Sensation 16 Speed 4 D, Siemens, Forchheim, Germany; gantry rotation time, 375 ms) and invasive coronary angiography. MSCT results were compared, blinded to the results of the coronary angiography with regard to the presence or absence of a significant stenosis (>50%) in a modified American Heart Association 13-segment model. Image quality was assessed on a qualitative scale between 1 (very good) and 5 (invisible) for each segment. RESULTS: Sensitivity, specificity, positive predictive value, and negative predictive value were statistically not different in diabetic and nondiabetic patients (0.85/0.98/0.92/0.96 vs. 0.84/0.97/0.91/0.95). One diabetic and three nondiabetic patients had to be excluded from analysis. Diabetic patients had relevantly more risk factors (P < .05), but calcium scoring was not different in both groups (Agatston score 1090+/-1278 vs. 798+/-1033). The image quality in both cohorts was comparable. CONCLUSIONS: MSCT allows the assessment of the coronary arteries noninvasively in diabetic patients with a good sensitivity and specificity, and diabetes does not have an impact on the number of evaluable segments. Thus, MSCT is a noninvasive tool in the care of these patients.


Assuntos
Doença da Artéria Coronariana/diagnóstico , Angiopatias Diabéticas/diagnóstico , Tomografia Computadorizada Espiral/métodos , Idoso , Calcinose/diagnóstico , Estudos de Coortes , Estenose Coronária/diagnóstico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Fatores de Risco , Sensibilidade e Especificidade , Tomografia Computadorizada Espiral/instrumentação
18.
J Am Coll Cardiol ; 45(1): 123-7, 2005 Jan 04.
Artigo em Inglês | MEDLINE | ID: mdl-15629385

RESUMO

OBJECTIVES: The aim of our study was to evaluate the diagnostic accuracy of 16-multi-detector spiral computed tomography (MDCT) with 188 ms temporal resolution. BACKGROUND: Because of rapid technical innovations, MDCT coronary imaging has significantly improved in the last five years. Recent results indicate a high diagnostic accuracy, especially in patients with clinical suspicion of coronary artery disease (CAD). METHODS: A total of 72 consecutive patients (30 women, 42 men, age 64 +/- 10 years) scheduled for invasive coronary angiography (ICA) because of suspected CAD were additionally studied by MDCT (Sensation 16 Speed 4D, Siemens, Forchheim, Germany). Thirty-seven of 72 patients (51%) received an additional beta-blockade before MDCT because of heart rates >65 beats/min. The MDCT scans were analyzed regarding the presence of coronary artery lesions. Results were compared with ICA. RESULTS: All 72 scans showed diagnostic image quality (heart rate: 64.1 +/- 9.2 beats/min, calcium mass: 86 +/- 156 mg). Thirteen coronary segments were evaluated in each patient. Sixty-two of 936 (6.6%) segments showed a nondiagnostic image quality. All segments were included in the analysis. A total of 117 relevant lesions (diameter stenosis >50%) were detected using ICA, and 96 of 117 (82%) were detected by MDCT. Sensitivity, specificity, and positive and negative predictive values for the whole study group were as follows: 82%, 98%, 87%, and 97%, respectively. The correct clinical diagnosis of presence or absence of significant CAD was obtained in 65 of 72 (90%) patients. All stenoses were detected by MDCT in 52 of 72 (72%) patients. CONCLUSIONS: Our results indicate a high diagnostic accuracy of 16-slice MDCT with improved temporal resolution.


Assuntos
Doença das Coronárias/diagnóstico por imagem , Tomografia Computadorizada Espiral/métodos , Adulto , Idoso , Estenose Coronária/diagnóstico por imagem , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Sensibilidade e Especificidade , Fatores Sexuais
19.
Int J Cardiol ; 106(2): 244-9, 2006 Jan 13.
Artigo em Inglês | MEDLINE | ID: mdl-16321698

RESUMO

BACKGROUND: Cardiac multi-slice computed tomography (MSCT) scanners permit visualization of the coronary arteries and coronary artery bypass grafts. The latest MSCT generation with true 16-detector slices (Sensation 16 Speed 4 D, Siemens, Forchheim, Germany) provides improved temporal and spatial resolution, as well as significantly reduced scan time. To assess, whether this technical improvement has also an impact on image quality and accuracy of MSCT diagnosis in patients with previous coronary artery bypass graft (CABG) surgery the following study was conducted. METHODS AND MATERIAL: Thirteen consecutive patients (pts) (10 male, 3 female, mean age 62 +/- 6.4 [55-73] years, heart rate 68 +/- 11 [52-88] bpm) and a total number of 43 coronary bypass grafts (11 arterial, 32 venous grafts) were examined by MSCT (gantry rotation time 375 ms). In addition to the analysis of coronary bypass grafts, 13 coronary segments (sgts) were evaluated in each patient (n = 169 sgts). MSCT results were compared with coronary angiography. RESULTS: Forty-one of 43 bypass grafts (95%) were analyzable by MSCT. In conventional angiography 16 of 43 (37%) grafts were occluded. Sixteen of them were correctly diagnosed by MSCT (sensitivity 100%). One graft showed a 50% anastomosis stenosis which was also detected. Twenty-five of 27 grafts without severe lesion showed no significant stenosis in MSCT (specificity 93%, positive predictive value (PPV) 89%, negative predictive value (NPV) 100%). Ninety of 108 (83%) high-grade stenosis (>70%) of the native coronary vessels were correctly detected (sensitivity 83%, PPV 78%). From the 61 sgts without high grade stenosis 36 were correctly classified (specificity 59%, NPV 67%). If sgts number 8, 9 and 10, which are normally not target for revascularization, are excluded sensitivity rises to 89%, specificity to 71%, PPV to 87% and NPV to 75%. The correct clinical diagnosis (absence or presence of a high grade stenosis of at least one bypass graft) was achieved in all patients. CONCLUSIONS: True 16-slice MSCT with faster gantry rotation time allows detection of lesions in coronary artery bypass grafts with high sensitivity and specificity. The evaluation of native vessels in pts with known CAD remains a diagnostic challenge. However, the correct clinical diagnosis was achieved in all pts. MSCT is a non-invasive tool to assess coronary artery bypass grafts.


Assuntos
Ponte de Artéria Coronária , Doença das Coronárias/diagnóstico por imagem , Doença das Coronárias/cirurgia , Tomografia Computadorizada por Raios X , Idoso , Angiografia Coronária , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Sensibilidade e Especificidade , Resultado do Tratamento
20.
J Am Coll Cardiol ; 44(6): 1230-7, 2004 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-15364324

RESUMO

OBJECTIVES: The aim of our study was to evaluate the feasibility of detecting coronary artery lesions using a new computed tomography (CT) scanner with 16 detectors and faster gantry rotation. BACKGROUND: Computed tomography angiography of the coronaries permits assessment of the coronaries; however, image quality is still impaired by motion artifacts and calcifications. METHODS: Sixty patients scheduled for conventional coronary angiography (CCA) were additionally studied by multislice spiral computed tomography (MSCT). Calcium scores and a contrast-enhanced visualization of the coronaries were performed and analyzed regarding evaluability, presence of coronary artery lesions, and correct clinical diagnosis. RESULTS: Calcium scoring was successful in all patients; 58 of 60 patients had a diagnostic contrast-enhanced scan. Mean calcium score was 506 +/- 743 Agatston score equivalent (ASE); 13 of 58 (22%) patients had an ASE >or=1,000, 46 of 58 (78%) patients <1,000. In 763 coronary segments, CCA detected a total of 75 lesions >or=50%. The MSCT correctly assessed 54 of these. Twenty-one lesions were missed or incorrectly underestimated. Sensitivity was 72%, specificity 97%. When restricting analysis to patients with an ASE <1,000, 40 significant lesions >or=50% were seen on CCA, and MSCT correctly detected 39 lesions (sensitivity 98%, specificity 98%). Regardless of any threshold, the correct clinical diagnosis could be obtained in 58 of 60 (97%) of all patients. CONCLUSIONS: In individuals with low-to-moderate amounts of coronary artery calcium, 16-detector CT coronary angiography has high sensitivity and specificity for the diagnosis of significant coronary artery stenosis.


Assuntos
Doença da Artéria Coronariana/diagnóstico por imagem , Tomografia Computadorizada Espiral , Adulto , Idoso , Calcinose/diagnóstico por imagem , Meios de Contraste , Angiografia Coronária , Feminino , Alemanha , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Interpretação de Imagem Radiográfica Assistida por Computador , Sensibilidade e Especificidade , Índice de Gravidade de Doença