Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 161
Filtrar
1.
Nature ; 626(8001): 990-998, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38383782

RESUMO

Electrode-based electrical stimulation underpins several clinical bioelectronic devices, including deep-brain stimulators1,2 and cardiac pacemakers3. However, leadless multisite stimulation is constrained by the technical difficulties and spatial-access limitations of electrode arrays. Optogenetics offers optically controlled random access with high spatiotemporal capabilities, but clinical translation poses challenges4-6. Here we show tunable spatiotemporal photostimulation of cardiac systems using a non-genetic platform based on semiconductor-enabled biomodulation interfaces. Through spatiotemporal profiling of photoelectrochemical currents, we assess the magnitude, precision, accuracy and resolution of photostimulation in four leadless silicon-based monolithic photoelectrochemical devices. We demonstrate the optoelectronic capabilities of the devices through optical overdrive pacing of cultured cardiomyocytes (CMs) targeting several regions and spatial extents, isolated rat hearts in a Langendorff apparatus, in vivo rat hearts in an ischaemia model and an in vivo mouse heart model with transthoracic optical pacing. We also perform the first, to our knowledge, optical override pacing and multisite pacing of a pig heart in vivo. Our systems are readily adaptable for minimally invasive clinical procedures using our custom endoscopic delivery device, with which we demonstrate closed-thoracic operations and endoscopic optical stimulation. Our results indicate the clinical potential of the leadless, lightweight and multisite photostimulation platform as a pacemaker in cardiac resynchronization therapy (CRT), in which lead-placement complications are common.


Assuntos
Terapia de Ressincronização Cardíaca , Desenho de Equipamento , Marca-Passo Artificial , Silício , Animais , Camundongos , Ratos , Terapia de Ressincronização Cardíaca/métodos , Endoscopia , Coração , Procedimentos Cirúrgicos Minimamente Invasivos , Isquemia Miocárdica/cirurgia , Isquemia Miocárdica/terapia , Miócitos Cardíacos , Semicondutores , Suínos , Modelos Animais
2.
Cardiol Young ; 33(7): 1192-1195, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36472122

RESUMO

Tricuspid atresia with common arterial trunk is a very rare association in complex CHD. This association has even more infrequently been documented concomitantly with interrupted aortic arch. We present the diagnosis and initial surgical management of an infant with a fetal diagnosis of tricuspid atresia and common arterial trunk, with additional postnatal finding of interrupted aortic arch with interruption between the left common carotid and left subclavian artery. Due to the infant's small size, she was initially palliated with bilateral pulmonary artery bands and a ductal stent. This was followed by septation of the common arterial trunk and interrupted aortic arch repair and 4 mm right subclavian artery to main pulmonary artery shunt placement at two months of age. She was discharged home on day of life 81.


Assuntos
Atresia Tricúspide , Persistência do Tronco Arterial , Lactente , Feminino , Humanos , Atresia Tricúspide/diagnóstico por imagem , Atresia Tricúspide/cirurgia , Persistência do Tronco Arterial/cirurgia , Artéria Pulmonar/diagnóstico por imagem , Artéria Pulmonar/cirurgia , Artéria Pulmonar/anormalidades , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/cirurgia , Aorta Torácica/anormalidades
3.
Proc Natl Acad Sci U S A ; 116(26): 12710-12719, 2019 06 25.
Artigo em Inglês | MEDLINE | ID: mdl-31182572

RESUMO

Despite significant research efforts, clinical practice for arterial bypass surgery has been stagnant, and engineered grafts continue to face postimplantation challenges. Here, we describe the development and application of a durable small-diameter vascular graft with tailored regenerative capacity. We fabricated small-diameter vascular grafts by electrospinning fibrin tubes and poly(ε-caprolactone) fibrous sheaths, which improved suture retention strength and enabled long-term survival. Using surface topography in a hollow fibrin microfiber tube, we enable immediate, controlled perfusion and formation of a confluent endothelium within 3-4 days in vitro with human endothelial colony-forming cells, but a stable endothelium is noticeable at 4 weeks in vivo. Implantation of acellular or endothelialized fibrin grafts with an external ultrathin poly(ε-caprolactone) sheath as an interposition graft in the abdominal aorta of a severe combined immunodeficient Beige mouse model supports normal blood flow and vessel patency for 24 weeks. Mechanical properties of the implanted grafts closely approximate the native abdominal aorta properties after just 1 week in vivo. Fibrin mediated cellular remodeling, stable tunica intima and media formation, and abundant matrix deposition with organized collagen layers and wavy elastin lamellae. Endothelialized grafts evidenced controlled healthy remodeling with delayed and reduced macrophage infiltration alongside neo vasa vasorum-like structure formation, reduced calcification, and accelerated tunica media formation. Our studies establish a small-diameter graft that is fabricated in less than 1 week, mediates neotissue formation and incorporation into the native tissue, and matches the native vessel size and mechanical properties, overcoming main challenges in arterial bypass surgery.


Assuntos
Materiais Biocompatíveis/química , Endotélio Vascular/fisiologia , Regeneração , Enxerto Vascular/métodos , Animais , Artérias/fisiologia , Artérias/cirurgia , Feminino , Fibrina/química , Camundongos , Poliésteres/química , Fluxo Sanguíneo Regional , Engenharia Tecidual/métodos
4.
J Card Surg ; 37(12): 5144-5152, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36378940

RESUMO

BACKGROUND: Tetralogy of Fallot (TOF) repair is a frequent procedure, and although valve-sparing (VS) repair is preferred, determining which patients can successfully undergo this operation remains controversial. We sought to identify parameters to determine a selective, accurate indication for VS repair. METHODS: We reviewed 71 patients (82%) undergoing VS repair. We analyzed hemodynamic data, intraoperative reports, and follow-up echocardiography results to identify acceptable indications. Patients requiring pulmonary valve (PV) reintervention versus no reintervention were compared. RESULTS: PV annulus size at repair was z-score of -2.0 (-5.3, 1.3). Approximately half (51%) had a z-score less than -2. Cox regression results showed this was not a risk factor for reintervention (p = .59). Overall, 1-, 3-, 5-, and 10-year freedom from PV reintervention rates were 95.8%, 92.8%, 91% and 77.8%, respectively. Residual pulmonary stenosis (PS) at initial repair was relatively higher in the reintervention group compared with no reintervention group (40 [28, 51] mmHg vs. 30 [22, 37] mmHg; p = .08). For patients with residual PS, pressure gradient (PG) was consistent over time across both groups (PV reintervention: -3 [-15, 8] mmHg vs. no reintervention: 0 [-9, 8] mmHg). The risk of PV reintervention is 3.7-fold higher when the PG from intraoperative TEE is greater than 45 mmHg (p = .04). CONCLUSIONS: Our review of the midterm outcomes of expanded indication for VS suggests intraoperative decision to convert to transannular patch is warranted if intraoperative postprocedure TEE PG is greater than 45 mmHg or RV pressure is higher than half of systemic pressure to prevent reintervention.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Estenose da Valva Pulmonar , Valva Pulmonar , Tetralogia de Fallot , Humanos , Lactente , Valva Pulmonar/cirurgia , Tetralogia de Fallot/diagnóstico por imagem , Tetralogia de Fallot/cirurgia , Procedimentos Cirúrgicos Cardíacos/métodos , Resultado do Tratamento , Estenose da Valva Pulmonar/diagnóstico por imagem , Estenose da Valva Pulmonar/cirurgia , Estudos Retrospectivos
5.
Biochem Biophys Res Commun ; 577: 12-16, 2021 11 05.
Artigo em Inglês | MEDLINE | ID: mdl-34487959

RESUMO

The Notch pathway is an ancient intercellular signaling system with crucial roles in numerous cell-fate decision processes across species. While the canonical pathway is activated by ligand-induced cleavage and nuclear localization of membrane-bound Notch, Notch can also exert its activity in a ligand/transcription-independent fashion, which is conserved in Drosophila, Xenopus, and mammals. However, the noncanonical role remains poorly understood in in vivo processes. Here we show that increased levels of the Notch intracellular domain (NICD) in the early mesoderm inhibit heart development, potentially through impaired induction of the second heart field (SHF), independently of the transcriptional effector RBP-J. Similarly, inhibiting Notch cleavage, shown to increase noncanonical Notch activity, suppressed SHF induction in embryonic stem cell (ESC)-derived mesodermal cells. In contrast, NICD overexpression in late cardiac progenitor cells lacking RBP-J resulted in an increase in heart size. Our study suggests that noncanonical Notch signaling has stage-specific roles during cardiac development.


Assuntos
Coração/embriologia , Miocárdio/metabolismo , Receptores Notch/metabolismo , Transdução de Sinais , Animais , Diferenciação Celular , Células Cultivadas , Fator de Transcrição GATA4/genética , Fator de Transcrição GATA4/metabolismo , Proteína Homeobox Nkx-2.5/genética , Proteína Homeobox Nkx-2.5/metabolismo , Proteínas de Homeodomínio/genética , Proteínas de Homeodomínio/metabolismo , Proteína de Ligação a Sequências Sinal de Recombinação J de Imunoglobina/genética , Proteína de Ligação a Sequências Sinal de Recombinação J de Imunoglobina/metabolismo , Mesoderma/citologia , Mesoderma/embriologia , Mesoderma/metabolismo , Camundongos , Camundongos Knockout , Camundongos Transgênicos , Células-Tronco Embrionárias Murinas/citologia , Células-Tronco Embrionárias Murinas/metabolismo , Miocárdio/citologia , Proteínas com Domínio T/genética , Proteínas com Domínio T/metabolismo , Fatores de Transcrição/genética , Fatores de Transcrição/metabolismo
6.
J Cardiovasc Magn Reson ; 23(1): 99, 2021 09 06.
Artigo em Inglês | MEDLINE | ID: mdl-34482836

RESUMO

BACKGROUND: Coarctation of the aorta (CoA) is associated with decreased exercise capacity despite successful repair. Altered flow patterns have been identified due to abnormal aortic arch geometry. Our previous work demonstrated aorta size mismatch to be associated with exercise intolerance in this population. In this study, we studied aortic flow patterns during simulations of exercise in repaired CoA using 4D flow cardiovascular magnetic resonance (CMR) using aortic replicas connected to an in vitro flow pump and correlated findings with exercise stress test results to identify biomarkers of exercise intolerance. METHODS: Patients with CoA repair were retrospectively analyzed after CMR and exercise stress test. Each aorta was manually segmented and 3D printed. Pressure gradient measurements from ascending aorta (AAo) to descending aorta (DAo) and 4D flow CMR were performed during simulations of rest and exercise using a mock circulatory flow loop. Changes in wall shear stress (WSS) and secondary flow formation (vorticity and helicity) from rest to exercise were quantified, as well as estimated DAo Reynolds number. Parameters were correlated with percent predicted peak oxygen consumption (VO2max) and aorta size mismatch (DAAo/DDAo). RESULTS: Fifteen patients were identified (VO2max 47 to 126% predicted). Pressure gradient did not correlate with VO2max at rest or exercise. VO2max correlated positively with the change in peak vorticity (R = 0.55, p = 0.03), peak helicity (R = 0.54, p = 0.04), peak WSS in the AAo (R = 0.68, p = 0.005) and negatively with peak WSS in the DAo (R = - 0.57, p = 0.03) from rest to exercise. DAAo/DDAo correlated strongly with change in vorticity (R = - 0.38, p = 0.01), helicity (R = - 0.66, p = 0.007), and WSS in the AAo (R = - 0.73, p = 0.002) and DAo (R = 0.58, p = 0.02). Estimated DAo Reynolds number negatively correlated with VO2max for exercise (R = - 0.59, p = 0.02), but not rest (R = - 0.28, p = 0.31). Visualization of streamline patterns demonstrated more secondary flow formation in aortic arches with better exercise capacity, larger DAo, and lower Reynolds number. CONCLUSIONS: There are important associations between secondary flow characteristics and exercise capacity in repaired CoA that are not captured by traditional pressure gradient, likely due to increased turbulence and inefficient flow. These 4D flow CMR parameters are a target of investigation to identify optimal aortic arch geometry and improve long term clinical outcomes after CoA repair.


Assuntos
Coartação Aórtica , Aorta , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/cirurgia , Coartação Aórtica/diagnóstico por imagem , Coartação Aórtica/cirurgia , Velocidade do Fluxo Sanguíneo , Hemodinâmica , Humanos , Espectroscopia de Ressonância Magnética , Valor Preditivo dos Testes , Estudos Retrospectivos
7.
J Card Surg ; 36(11): 4054-4060, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34423475

RESUMO

BACKGROUND: Aortic cusp extension is a technique for aortic valve (AV) repairs in pediatric patients. The choice of the material used in this procedure may influence the time before reoperation is required. We aimed to assess postoperative and long-term outcomes of patients receiving either pericardial or synthetic repairs. METHODS: We conducted a single-center, retrospective study of pediatric patients undergoing aortic cusp extension valvuloplasty (N = 38) with either autologous pericardium (n = 30) or CorMatrix (n = 8) between April 2009 and July 2016. Short- and long-term postoperative outcomes were compared between the two groups. Freedom from reoperation was compared using Kaplan-Meier analysis. Degree of aortic stenosis (AS) and aortic regurgitation (AR) were recorded at baseline, postoperatively, and at outpatient follow-up. RESULTS: At 5 years after repair, freedom from reoperation was significantly lower in the CorMatrix group (12.5%) compared to the pericardium group (62.5%) (p = .01). For the entire cohort, there was a statistically significant decrease in the peak trans-valvar gradient between preoperative and postoperative assessments with no significant change at outpatient follow-up. In the pericardium group, 28 (93%) had moderate to severe AR at baseline which improved to 11 (37%) postoperatively and increased to 21 (70%) at time of follow-up. In the biomaterial group, eight (100%) had moderate to severe AR which improved to three (38%) postoperatively and increased to seven (88%) at time of follow-up. CONCLUSION: In terms of durability, the traditional autologous pericardium may outperform the new CorMatrix for AV repairs using the cusp extension method.


Assuntos
Insuficiência da Valva Aórtica , Estenose da Valva Aórtica , Procedimentos Cirúrgicos Cardíacos , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Criança , Humanos , Reoperação , Estudos Retrospectivos , Resultado do Tratamento
8.
Cardiol Young ; 31(5): 848-850, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33487195

RESUMO

Loeys-Dietz syndrome is a connective tissue disorder known to cause aggressive aortopathy in paediatric patients, but it is extremely rare for cardiovascular events to present during infancy. We report the first successful aortic repair in a neonate with LDS presenting in extremis with an early onset, massive aortic aneurysm.


Assuntos
Aneurisma da Aorta Torácica , Síndrome de Loeys-Dietz , Procedimentos de Cirurgia Plástica , Aneurisma da Aorta Torácica/cirurgia , Criança , Humanos , Recém-Nascido , Síndrome de Loeys-Dietz/complicações , Síndrome de Loeys-Dietz/diagnóstico , Síndrome de Loeys-Dietz/cirurgia , Procedimentos Cirúrgicos Vasculares
9.
Cardiol Young ; 31(3): 476-478, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33272339

RESUMO

A full-term, female presented on her date of birth with severe pulmonary hypertension (PH) and mitral regurgitation (MR), requiring veno-arterial extracorporeal membrane oxygenation. After the treatment, her PH and MR were resolved with no anatomic abnormality present. We propose a positive feedback loop of PH causing right ventricular dilation and interventricular septal shifts, worsening MR, and elevated left atrial, and potentially pulmonary, pressures.


Assuntos
Oxigenação por Membrana Extracorpórea , Hipertensão Pulmonar , Insuficiência da Valva Mitral , Feminino , Átrios do Coração , Humanos , Hipertensão Pulmonar/complicações , Hipertensão Pulmonar/diagnóstico , Lactente , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/complicações , Insuficiência da Valva Mitral/diagnóstico
10.
J Card Surg ; 35(6): 1357-1359, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32333435

RESUMO

We report a case of successful heart and liver transplantation requiring intraoperative extracorporeal membrane oxygenation (ECMO) for primary cardiac allograft dysfunction in a patient with Fontan failure. A successful outcome for both the heart and the liver can be achieved with the timely management of ECMO support. In describing our experiences treating a Fontan patient requiring multiorgan transplantation, we have shown that challenging cases such as this one can have successful outcomes if multidisciplinary collaborations and proper treatment strategies are utilized at the optimal timing, along with family support and patient cooperation.


Assuntos
Oxigenação por Membrana Extracorpórea , Técnica de Fontan , Transplante de Coração , Cuidados Intraoperatórios , Transplante de Fígado , Disfunção Primária do Enxerto/terapia , Adulto , Aloenxertos , Feminino , Humanos , Comunicação Interdisciplinar , Cooperação do Paciente , Falha de Tratamento , Resultado do Tratamento
11.
Artif Organs ; 43(1): 21-29, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30084490

RESUMO

While pediatric HeartWare HVAD application has increased, determining candidacy and timing for initiation of pediatric VAD support has remained a challenge. We present our experience with a systematic approach to HVAD implantation as a bridge to pediatric heart transplantation. We performed a retrospective, single center review of pediatric patients (n = 11) who underwent HVAD implantation between September 2014 and January 2018. Primary endpoints evaluated were survival to heart transplantation, need for right ventricular assist device (RVAD) at any point, ongoing HVAD support, or death. Median patient age was 11 years (range: 3-16). Median BSA was 1.25 m2 (range: 0.56-2.1). Heart failure etiologies requiring support were dilated cardiomyopathy (n = 8), myocarditis (n = 1), congenital mitral valve disease (n = 1), and single ventricle heart failure (n = 1). Median time from cardiac ICU admission for heart failure to HVAD placement was 15 days (range 3-55), based on standardized VAD implantation criteria involving imaging assessment and noncardiac organ evaluation. The majority of patients (91%) were INTERMACS Level 2 at time of implant. Three patients (27%) had CentriMag RVAD placement at time of HVAD implantation. Two of these three patients had successful RVAD explanation within 2 weeks. Median length of HVAD support was 60 days (range 6-405 days). Among the 11 patients, survival during HVAD therapy to date is 91% (10/11) with 9 (82%) bridged to heart transplantation and one (9%) continuing to receive support. Posttransplant survival has been 100%, with median follow-up of 573 days (range 152-1126). A systematic approach to HVAD implantation can provide excellent results in pediatric heart failure management for a variety of etiologies and broad BSA range.


Assuntos
Insuficiência Cardíaca/cirurgia , Transplante de Coração , Coração Auxiliar , Seleção de Pacientes , Implantação de Prótese/normas , Adolescente , Criança , Pré-Escolar , Feminino , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/mortalidade , Humanos , Masculino , Implantação de Prótese/instrumentação , Implantação de Prótese/métodos , Estudos Retrospectivos , Análise de Sobrevida , Fatores de Tempo , Resultado do Tratamento , Listas de Espera/mortalidade
12.
J Cardiothorac Vasc Anesth ; 33(10): 2804-2813, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30738750

RESUMO

Perfusion strategies for cardiopulmonary bypass have direct consequences on pediatric cardiac surgery outcomes. However, inconsistent study results and a lack of uniform evidence-based guidelines for pediatric cardiopulmonary bypass management have led to considerable variability in perfusion practices among, and even within, institutions. Important aspects of cardiopulmonary bypass that can be optimized to improve clinical outcomes of pediatric patients undergoing cardiac surgery include extracorporeal circuit components, priming solutions, and additives. This review summarizes the current literature on circuit components and priming solution composition with an emphasis on crystalloid, colloid, and blood-based primes, as well as mannitol, bicarbonate, and calcium.


Assuntos
Procedimentos Cirúrgicos Cardíacos/tendências , Ponte Cardiopulmonar/métodos , Ponte Cardiopulmonar/tendências , Albuminas/efeitos adversos , Albuminas/farmacologia , Procedimentos Cirúrgicos Cardíacos/métodos , Soluções Cardioplégicas , Ponte Cardiopulmonar/instrumentação , Criança , Soluções Cristaloides , Drenagem/métodos , Desenho de Equipamento , Humanos , Bombas de Infusão , Propriedades de Superfície
13.
Cardiol Young ; 29(7): 1002-1004, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31221232

RESUMO

Aneurysms of the right atrium are rare in the paediatric population. We report a case of a foetal diagnosis of right atrial aneurysm with associated atrial tachycardia in foetal and postnatal life. Unique to our case are the findings of isolated pericardial effusion without hydrops fetalis and the development of aortic coarctation in postnatal life.


Assuntos
Coartação Aórtica/complicações , Coartação Aórtica/diagnóstico , Aneurisma Cardíaco/complicações , Aneurisma Cardíaco/diagnóstico , Disfunção Ventricular Esquerda/complicações , Disfunção Ventricular Esquerda/diagnóstico , Adulto , Coartação Aórtica/cirurgia , Feminino , Aneurisma Cardíaco/cirurgia , Humanos , Recém-Nascido , Gravidez , Ultrassonografia Pré-Natal , Disfunção Ventricular Esquerda/cirurgia
14.
Pediatr Res ; 83(1-2): 223-231, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-28985202

RESUMO

Recent advances have allowed for three-dimensional (3D) printing technologies to be applied to biocompatible materials, cells and supporting components, creating a field of 3D bioprinting that holds great promise for artificial organ printing and regenerative medicine. At the same time, stem cells, such as human induced pluripotent stem cells, have driven a paradigm shift in tissue regeneration and the modeling of human disease, and represent an unlimited cell source for tissue regeneration and the study of human disease. The ability to reprogram patient-specific cells holds the promise of an enhanced understanding of disease mechanisms and phenotypic variability. 3D bioprinting has been successfully performed using multiple stem cell types of different lineages and potency. The type of 3D bioprinting employed ranged from microextrusion bioprinting, inkjet bioprinting, laser-assisted bioprinting, to newer technologies such as scaffold-free spheroid-based bioprinting. This review discusses the current advances, applications, limitations and future of 3D bioprinting using stem cells, by organ systems.


Assuntos
Bioimpressão/métodos , Células-Tronco Pluripotentes Induzidas/citologia , Impressão Tridimensional , Medicina Regenerativa/métodos , Tecido Adiposo/fisiologia , Animais , Órgãos Artificiais , Materiais Biocompatíveis/química , Osso e Ossos/fisiologia , Sistema Cardiovascular , Células Endoteliais da Veia Umbilical Humana , Humanos , Lasers , Fígado/fisiologia , Células-Tronco Mesenquimais/fisiologia , Camundongos , Músculo Esquelético/fisiologia , Sistema Nervoso , Pele/metabolismo , Cicatrização
15.
J Card Surg ; 33(6): 339-343, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29726037

RESUMO

BACKGROUND: Loeys-Dietz syndrome (LDS) is an autosomal dominant connective tissue disorder predisposing patients to aneurysm formation and arterial dissection. Aortic root replacement is often performed prophylactically and valve-sparing root replacement (VSRR) has become the procedure of choice. However, in these patients with connective tissue disorders, postoperative pseudoaneurysms may develop. METHODS: All children with LDS undergoing VSRR at a single institution were retrospectively reviewed to identify patients who developed postoperative pseudoaneurysms. RESULTS: Thirty-one children with LDS underwent VSRR; four of these developed pseudoaneurysms of their synthetic aortic root grafts requiring reoperation. These four children were reviewed to investigate the cause of pseudoaneurysm formation after VSRR. Each had severe subtypes of LDS. Each underwent reoperation for repair of their pseudoaneurysms and were found to have suffered pseudoaneurysms as a result of tearing of sutures from their reimplantation VSRR. CONCLUSIONS: Pseudoaneurysms following aortic root replacement with VSRR can occur in children with severe subtypes of LDS. Long-term surveillance is required to detect these potentially life-threatening lesions.


Assuntos
Falso Aneurisma/etiologia , Falso Aneurisma/cirurgia , Aneurisma Aórtico/etiologia , Aneurisma Aórtico/cirurgia , Implante de Prótese Vascular/métodos , Síndrome de Loeys-Dietz/complicações , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/cirurgia , Adolescente , Adulto , Feminino , Humanos , Lactente , Masculino , Reoperação , Índice de Gravidade de Doença , Adulto Jovem
16.
FASEB J ; 30(7): 2627-36, 2016 07.
Artigo em Inglês | MEDLINE | ID: mdl-27059717

RESUMO

Stenosis is a critical problem in the long-term efficacy of tissue-engineered vascular grafts (TEVGs). We previously showed that host monocyte infiltration and activation within the graft drives stenosis and that TGF-ß receptor 1 (TGF-ßR1) inhibition can prevent it, but the latter effect was attributed primarily to inhibition of mesenchymal cell expansion. In this study, we assessed the effects of TGF-ßR1 inhibition on the host monocytes. Biodegradable TEVGs were implanted as inferior vena cava interposition conduits in 2 groups of C57BL/6 mice (n = 25/group): unseeded grafts and unseeded grafts with TGF-ßR1 inhibitor systemic treatment for the first 2 wk. The TGF-ßR1 inhibitor treatment effectively improved TEVG patency at 6 mo compared to the untreated control group (91.7 vs. 48%, P < 0.001), which is associated with a reduction in classic activation of mononuclear phagocytes. Consistent with these findings, the addition of rTGF-ß to LPS/IFN-γ-stimulated monocytes enhanced secretion of inflammatory cytokines TNF-α, IL-12, and IL-6; this effect was blocked by TGF-ßR1 inhibition (P < 0.0001). These findings suggest that the TGF-ß signaling pathway contributes to TEVG stenosis by inducing classic activation of host monocytes. Furthermore, blocking monocyte activation by TGF-ßR1 inhibition provides a viable strategy for preventing TEVG stenosis while maintaining neotissue formation.-Lee, Y.-U., de Dios Ruiz-Rosado, J., Mahler, N., Best, C. A., Tara, S., Yi, T., Shoji, T., Sugiura, T., Lee, A. Y., Robledo-Avila, F., Hibino, N., Pober, J. S., Shinoka, T., Partida-Sanchez, S., Breuer, C. K. TGF-ß receptor 1 inhibition prevents stenosis of tissue-engineered vascular grafts by reducing host mononuclear phagocyte activation.


Assuntos
Leucócitos Mononucleares/fisiologia , Receptores de Fatores de Crescimento Transformadores beta/metabolismo , Animais , Prótese Vascular , Constrição Patológica , Citocinas/genética , Citocinas/metabolismo , Camundongos , Camundongos Endogâmicos C57BL , Receptores de Fatores de Crescimento Transformadores beta/genética , Engenharia Tecidual , Alicerces Teciduais
17.
FASEB J ; 29(6): 2431-8, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25713026

RESUMO

The first clinical trial of tissue-engineered vascular grafts (TEVGs) identified stenosis as the primary cause of graft failure. In this study, we aimed to elucidate the role of the host immune response in the development of stenosis using a murine model of TEVG implantation. We found that the C.B-17 wild-type (WT) mouse (control) undergoes a dramatic stenotic response, which is nearly completely abolished in the immunodeficient SCID/beige (bg) variant. SCID mice, which lack an adaptive immune system due to the absence of T and B lymphocytes, experienced rates of stenosis comparable to WT controls (average luminal diameter, WT: 0.071 ± 0.035 mm, SCID: 0.137 ± 0.032 mm, SCID/bg: 0.804 ± 0.039 mm; P < 0.001). The bg mutation is characterized by NK cell and platelet dysfunction, and systemic treatment of WT mice with either NK cell-neutralizing (anti-NK 1.1 antibody) or antiplatelet (aspirin/Plavix [clopidogrel bisulfate]; Asp/Pla) therapy achieved nearly half the patency observed in the SCID/bg mouse (NK Ab: 0.356 ± 0.151 mm, Asp/Pla: 0.452 ± 0.130 mm). Scaffold implantation elicited a blunted immune response in SCID/bg mice, as demonstrated by macrophage number and mRNA expression of proinflammatory cytokines in TEVG explants. Implicating the initial innate immune response as a critical factor in graft stenosis may provide a strategy for prognosis and therapy of second-generation TEVGs.


Assuntos
Imunidade Adaptativa/imunologia , Implante de Prótese Vascular/normas , Prótese Vascular/normas , Imunidade Inata/imunologia , Animais , Antígenos de Diferenciação/genética , Antígenos de Diferenciação/imunologia , Antígenos de Diferenciação/metabolismo , Linfócitos B/imunologia , Linfócitos B/metabolismo , Plaquetas/imunologia , Plaquetas/metabolismo , Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/efeitos adversos , Constrição Patológica/etiologia , Constrição Patológica/imunologia , Citocinas/genética , Citocinas/imunologia , Feminino , Expressão Gênica/imunologia , Sistema Imunitário/citologia , Sistema Imunitário/imunologia , Sistema Imunitário/metabolismo , Imuno-Histoquímica , Mediadores da Inflamação/imunologia , Mediadores da Inflamação/metabolismo , Células Matadoras Naturais/imunologia , Células Matadoras Naturais/metabolismo , Macrófagos/imunologia , Macrófagos/metabolismo , Camundongos , Camundongos SCID , Reação em Cadeia da Polimerase Via Transcriptase Reversa , Linfócitos T/imunologia , Linfócitos T/metabolismo
18.
Arterioscler Thromb Vasc Biol ; 35(9): 2003-10, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26183618

RESUMO

OBJECTIVE: Despite successful translation of bioresorbable vascular grafts for the repair of congenital heart disease, stenosis remains the primary cause of graft failure. In this study, we investigated the efficacy of long-term treatment with the antiplatelet drugs, aspirin and cilostazol, in preventing stenosis and evaluated the effect of these drugs on the acute phase of inflammation and tissue remodeling. APPROACH AND RESULTS: C57BL/6 mice were fed a drug-mixed diet of aspirin, cilostazol, or normal chow during the course of follow-up. Bioresorbable vascular grafts, composed of poly(glycolic acid) mesh sealed with poly(l-lactide-co-ε-caprolactone), were implanted as inferior vena cava interposition conduits and followed up for 2 weeks (n=10 per group) or 24 weeks (n=15 per group). Both aspirin and cilostazol suppressed platelet activation and attachment onto the grafts. On explant at 24 weeks, well-organized neotissue had developed, and cilostazol treatment resulted in 100% graft patency followed by the aspirin (67%) and no-treatment (60%) groups (P<0.05). Wall thickness and smooth muscle cell proliferation in the neotissue of the cilostazol group were decreased when compared with that of the no-treatment group at 24 weeks. In addition, cilostazol was shown to have an anti-inflammatory effect on neotissue at 2 weeks by regulating the recruitment and activation of monocytes. CONCLUSIONS: Cilostazol prevents stenosis of bioresorbable vascular graft in a mouse inferior vena cava implantation model up to 24 weeks and is accompanied by reduction of smooth muscle cell proliferation and acute inflammation.


Assuntos
Implantes Absorvíveis , Prótese Vascular , Oclusão de Enxerto Vascular/prevenção & controle , Insuficiência Cardíaca/cirurgia , Tetrazóis/farmacologia , Remodelação Vascular/efeitos dos fármacos , Veia Cava Inferior/cirurgia , Animais , Aspirina/farmacologia , Proliferação de Células , Cilostazol , Modelos Animais de Doenças , Técnica de Fontan/métodos , Oclusão de Enxerto Vascular/patologia , Insuficiência Cardíaca/patologia , Imuno-Histoquímica , Camundongos , Camundongos Endogâmicos C57BL , Inibidores da Agregação Plaquetária/farmacologia , Falha de Prótese , Resultado do Tratamento
19.
Circ J ; 78(1): 12-9, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24334558

RESUMO

The development of vascular bioengineering has led to a variety of novel treatment strategies for patients with cardiovascular disease. Notably, combining biodegradable scaffolds with autologous cell seeding to create tissue-engineered vascular grafts (TEVG) allows for in situ formation of organized neovascular tissue and we have demonstrated the clinical viability of this technique in patients with congenital heart defects. The role of the scaffold is to provide a temporary 3-dimensional structure for cells, but applying TEVG strategy to the arterial system requires scaffolds that can also endure arterial pressure. Both biodegradable synthetic polymers and extracellular matrix-based natural materials can be used to generate arterial scaffolds that satisfy these requirements. Furthermore, the role of specific cell types in tissue remodeling is crucial and as a result many different cell sources, from matured somatic cells to stem cells, are now used in a variety of arterial TEVG techniques. However, despite great progress in the field over the past decade, clinical effectiveness of small-diameter arterial TEVG (<6mm) has remained elusive. To achieve successful translation of this complex multidisciplinary technology to the clinic, active participation of biologists, engineers, and clinicians is required.


Assuntos
Implantes Absorvíveis , Prótese Vascular , Cardiopatias Congênitas/terapia , Engenharia Tecidual/métodos , Alicerces Teciduais , Animais , Cardiopatias Congênitas/fisiopatologia , Humanos , Engenharia Tecidual/tendências
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA