Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Int J Mol Sci ; 22(12)2021 Jun 14.
Artigo em Inglês | MEDLINE | ID: mdl-34198683

RESUMO

We noted recently that the injection of cells with a needle through a cystoscope in the urethral sphincter muscle of pigs failed to deposit them nearby or at the intended target position in about 50% of all animals investigated (n > 100). Increasing the chance for precise cell injection by shotgun approaches employing several circumferential injections into the sphincter muscle bears the risk of tissue injury. In this study, we developed and tested a novel needle-free technique to precisely inject cells in the urethral sphincter tissue, or other tissues, using a water-jet system. This system was designed to fit in the working channels of endoscopes and cystoscopes, allowing a wide range of minimally invasive applications. We analyze key features, including the physical parameters of the injector design, pressure ranges applicable for tissue penetration and cell injections and biochemical parameters, such as different compositions of injection media. Our results present settings that enable the high viability of cells post-injection. Lastly, the method is suitable to inject cells in the superficial tissue layer and in deeper layers, required when the submucosa or the sphincter muscle of the urethra is targeted.


Assuntos
Células/metabolismo , Técnicas Citológicas/métodos , Animais , Sobrevivência Celular , Endoscopia , Células HeLa , Humanos , Suínos , Água
2.
Immunobiology ; 226(6): 152144, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34624625

RESUMO

Regulatory T cells (Tregs) maintain immune homeostasis by regulating the activation of other immune cells. Preclinical studies show that the infusion of Tregs can promote immunological tolerance to allografts and prevent or cure multiple autoimmune diseases. However, Treg therapy is limited by high numbers of cells required to induce tolerance. In this study, we aimed at improving the in vitro expansion of sort purified mouse Tregs using the CD28 Superagonist (CD28-SA) D665 and comparing it to the conventional expansion using anti-CD3/anti-CD28 Dynabeads®. CD28-SA-stimulated Tregs expanded more than Dynabead®-stimulated Tregs while maintaining their phenotype by expressing the same level of CD4, CD25 and Foxp3. CD28-SA-expanded Tregs produced comparable amounts of IL-10 and TGFß while showing a slightly superior suppressive capacity compared to Dynabead®-stimulated Tregs. Thus, stimulating murine Tregs with the CD28-SA is a promising alternative since it maintains their suppressive capacity without altering their phenotype and yields a higher fold expansion within 14 days.


Assuntos
Antígenos CD28/agonistas , Fatores Imunológicos/farmacologia , Imunomodulação/efeitos dos fármacos , Linfócitos T Reguladores/efeitos dos fármacos , Linfócitos T Reguladores/imunologia , Linfócitos T Reguladores/metabolismo , Animais , Biomarcadores , Imunofenotipagem , Ativação Linfocitária , Masculino , Camundongos
3.
Swiss Med Wkly ; 137(37-38): 536-40, 2007 Sep 22.
Artigo em Inglês | MEDLINE | ID: mdl-17990144

RESUMO

BACKGROUND: Patients and medical personnel are eager to use blood glucose meters that are easy to handle and fast acting. We questioned whether accuracy and precision of these new, small and light weight devices would meet analytical laboratory standards and tested four meters with the above mentioned conditions. METHODS: Approximately 300 capillary blood samples were collected and tested using two devices of each brand and two different types of glucose test strips. Blood from the same samples was used for comparison. Results were evaluated using maximum deviation of 5% and 10% from the comparative method, the error grid analysis, the overall deviation of the devices, the linear regression analysis as well as the CVs for measurement in series. RESULTS: Of all 1196 measurements a deviation of less than 5% resp. 10% from the reference method was found for the FreeStyle (FS) meter in 69.5% and 96%, the Glucocard X Meter (GX) in 44% and 75%, the One Touch Ultra (OT) in 29% and 60%, the Wellion True Track (WT) in 28.5% and 58%. The error grid analysis gave 99.7% for FS, 99% for GX, 98% for OT and 97% for WT in zone A. The remainder of the values lay within zone B. Linear regression analysis resembled these results. CVs for measurement in series showed higher deviations for OT and WT compared to FS and GX. CONCLUSIONS: The four new, small and fast acting glucose meters fulfil clinically relevant analytical laboratory requirements making them appropriate for use by medical personnel. However, with regard to the tight and restrictive limits of the ADA recommendations, the devices are still in need of improvement. This should be taken into account when the devices are used by primarily inexperienced persons and is relevant for further industrial development of such devices.


Assuntos
Análise Química do Sangue/instrumentação , Análise Química do Sangue/normas , Glicemia/análise , Calibragem , Humanos , Modelos Lineares , Controle de Qualidade , Fitas Reagentes , Valores de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA