Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 33
Filtrar
1.
Diabetes Obes Metab ; 14(3): 283-7, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22051162

RESUMO

To compare the effects of miglitol [an alpha-glucosidase inhibitor (AGI) absorbed in the intestine] and voglibose (an AGI not absorbed) on plasma glucagon-like peptide-1 (GLP-1) and gastric inhibitory polypeptide (GIP) levels, 26 and 24 Japanese type 2 diabetic patients were randomly assigned to receive miglitol or voglibose, respectively. After 12-week administration of both drugs, during 2-h meal tolerance test, plasma glucose, serum insulin and total GIP were significantly decreased and active GLP-1 was significantly increased. Miglitol group showed a significantly lower total GIP level than voglibose group. Miglitol, but not voglibose, significantly reduced body weight (BW). In all participants, the relative change in BW was positively correlated with that of insulin significantly and of GIP with a weak tendency, but not of GLP-1. In conclusion, both drugs can enhance postprandial GLP-1 responses and reduce GIP responses. The significant BW reduction by miglitol might be attributable to its strong GIP-reducing efficacy.


Assuntos
1-Desoxinojirimicina/análogos & derivados , Diabetes Mellitus Tipo 2/tratamento farmacológico , Hipoglicemiantes/farmacologia , Incretinas/sangue , Inositol/análogos & derivados , Obesidade/tratamento farmacológico , 1-Desoxinojirimicina/administração & dosagem , 1-Desoxinojirimicina/farmacologia , Povo Asiático , Diabetes Mellitus Tipo 2/sangue , Diabetes Mellitus Tipo 2/metabolismo , Esquema de Medicação , Feminino , Polipeptídeo Inibidor Gástrico/efeitos dos fármacos , Peptídeo 1 Semelhante ao Glucagon/efeitos dos fármacos , Humanos , Hipoglicemiantes/administração & dosagem , Inositol/administração & dosagem , Inositol/farmacologia , Masculino , Pessoa de Meia-Idade , Obesidade/sangue , Obesidade/metabolismo , Período Pós-Prandial
2.
Horm Metab Res ; 41(12): 910-5, 2009 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-19670106

RESUMO

Previous studies of diabetic patients indicate that increased urinary excretion of certain plasma proteins (molecular radii <55 A), such as IgG, transferrin, and ceruloplasmin, precede the development of microalbuminuria. Moreover, increases in these urinary proteins predict future development of microalbuminuria. To clarify whether blood pressure changes influence urinary excretion of these proteins, we examined relationships between diurnal blood pressure changes measured by ambulatory blood pressure monitoring and urinary excretion of IgG, transferrin, ceruloplasmin, alpha2-macroglobulin (88 A) and albumin (36 A) measured separately during the day and night in 20 healthy controls and 26 normotensive, normoalbuminuric diabetic patients. Diurnal change in systolic blood pressure was not correlated to urinary excretion of either albumin or alpha2-macroglobulin in either diabetic patients or controls. However, statistically significant correlations between diurnal changes in systolic blood pressure and those of urinary excretion of IgG, transferrin and ceruloplasmin were found in diabetic patients but not in controls. The present findings suggest that urinary excretion of IgG, transferrin, and ceruloplasmin are more easily affected than albuminuria by systemic blood pressure changes in normoalbuminuric diabetic patients. This is supported by our previous finding that urinary excretion of IgG, transferrin and ceruloplasmin increased while albuminuria did not following enhanced glomerular filtration rate after acute protein loading, which causes increased glomerular capillary pressure due to afferent arterioles dilation, mimicking diabetic intra-renal hemodynamics. Taken together, these findings suggest that urinary excretion of IgG, transferrin, and ceruloplasmin may be more sensitive indicators of glomerular capillary pressure change than albuminuria in normoalbuminuric diabetic patients.


Assuntos
Pressão Sanguínea/fisiologia , Ceruloplasmina/urina , Ritmo Circadiano/fisiologia , Diabetes Mellitus Tipo 2/fisiopatologia , Diabetes Mellitus Tipo 2/urina , Imunoglobulina G/urina , Transferrina/urina , Adulto , Idoso , Albuminúria/urina , Proteínas Sanguíneas/urina , Estudos de Casos e Controles , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
3.
Int J Radiat Oncol Biol Phys ; 34(5): 1105-11, 1996 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-8600094

RESUMO

PURPOSE: To introduce the process of developing an integrated radiotherapy network. METHODS AND MATERIALS: We developed a new radiotherapy treatment-planning system in 1987 that we named the Computer Tomography (CT) simulator. CT images were immediately transported to multiimage monitors and to a planning computer, and treatment planning could be performed with the patient lying on the CT couch. The results of planning were used to guide a laser projector, and radiation fields were projected onto the skin of the patient. Since 1991, an integrated radiotherapy network system has been developed, which consists of a picture archiving and communicating system (PACS), a radiotherapy information database, a CT simulator, and a linear accelerator with a multileaf collimator. RESULTS: Clinical experience has been accumulated in more than 1,000 patients. Based on our 7 years of experience, we have modified several components of our original CT simulator and have developed a second generation CT simulator. A standard protocol has been developed for communication between the CT scanner, treatment planning computer, and radiotherapy apparatus using the Ethernet network. As a result, treatment planning data can be transported to the linear accelerator within 1 min after completion of treatment planning. CONCLUSION: This system enables us to make optimal use of CT information and to devise accurate three-dimensional (3D) treatment-planning programs. Our network also allows for the performance of fully computer-controlled dynamic arc conformal therapy.


Assuntos
Redes de Comunicação de Computadores/organização & administração , Simulação por Computador , Sistemas de Informação em Radiologia/organização & administração , Planejamento da Radioterapia Assistida por Computador/organização & administração , Tomografia Computadorizada por Raios X
4.
J Nucl Med ; 27(7): 1184-91, 1986 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-3487628

RESUMO

To perform accurate in vivo quantitation by single photon emission computed tomography, we have developed a new method for detecting body contours for the correction of tissue attenuation. Our method can rapidly derive the best fit contours throughout the body by using the measured axial length of the patient body and Fourier filtering the detected contours which are defined by a unique bit-plane algorithm. We have also evaluated the effects of the body contours on the reconstructed images by using various attenuation correction techniques including a precorrection method (Sorenson, 1974), a postcorrection method (Chang, 1978), a weighted backprojection method, and a radial post correction method (Tanaka, 1983 and 1984). Counts in the specified region-of-interest in phantom images reconstructed by the radial postcorrection, weighted backprojection, and postcorrection methods were more strongly affected by inaccurately detected contours than were counts derived from images reconstructed by the precorrection method.


Assuntos
Superfície Corporal , Tomografia Computadorizada de Emissão/métodos , Humanos
6.
Brain Res ; 153(3): 495-505, 1978 Sep 29.
Artigo em Inglês | MEDLINE | ID: mdl-698790

RESUMO

The effect of cerebellar stimulation on the accommodation of the lens was examined in anesthetized cats. An infrared optometer was used to measure the refractive power of the lens during stimulation of the cerebellum. The area giving responses within latencies shorter than 160 msec and amplitudes larger than 0.15 diopters is localized in the contralateral interpositus and fastigial nuclei and the ipsilateral interpositus nucleus. No responses could be evoked by stimulating the bilateral lateral nuclei. Accommodation responses were also evoked by cerebellar cortex stimulation. Accommodation responses evoked by stimulating the cerebellar nuclei were inhibited by preceding cerebellar cortical stimulation.


Assuntos
Adaptação Ocular , Cerebelo/fisiologia , Acomodação Ocular , Animais , Mapeamento Encefálico , Gatos , Córtex Cerebelar/fisiologia , Núcleos Cerebelares/fisiologia , Estimulação Elétrica , Cristalino/inervação , Inibição Neural , Tempo de Reação/fisiologia , Refração Ocular , Vias Visuais/fisiologia
7.
Brain Res ; 128(1): 69-79, 1977 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-871913

RESUMO

The effect of cerebellar lesions upon the pupillary light reflex was examined in anesthetized cats. The pupillary response elicited by a step and sinusoidally modulated light stimulus was used. In acute cerebellectomized cats, the high frequency cutoff of the frequency response of the pupillary reflex was moved to a lower level after cerebellar lesions. Selective lesions were made in the deep cerebellar nuclei and the frequency responses of the pupillary reflex were compared. The fastigial lesions produced the most prominent change in the frequency responses. Electrical stimulation of the deep cerebellar nuclei, especially the fastigial nuclei, induced pupillary dilatation. Thus the cerebellum appears to participate in the control of the pupillary light reflex by improving the frequency responses of the pupil so that it can follow changing light stimuli better, and this control is exerted via the bilateral fastigial nuclei.


Assuntos
Núcleos Cerebelares/fisiologia , Luz , Reflexo Pupilar , Animais , Gatos , Potenciais Evocados , Tempo de Reação
8.
Ann Nucl Med ; 3(2): 83-8, 1989 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-2641452

RESUMO

Left ventricular ejection fraction (EF) was measured by factor analysis (FA) of multigated cardiac blood pool scintigram in 38 consecutive patients, and compared with that measured by the variable ROI method (EFVROI) with automated left ventricular contour detection. FA was automatically performed without operator intervention with a success rate of 100%. The correlation of EF with EFVROI was significant in the group of 22 patients with normal wall motion (r = 0.65, p less than 0.001), and the entire group of patients (r = 0.70, p less than 0.001), but not significant (p = 0.19) in the group of 16 patients with abnormal wall motion. In conclusion, left ventricular ejection fraction can be estimated by factor analysis of MUGA in patients with normal wall motion.


Assuntos
Imagem do Acúmulo Cardíaco de Comporta/estatística & dados numéricos , Volume Sistólico , Adulto , Idoso , Análise Fatorial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
9.
Radiat Med ; 7(3): 124-8, 1989.
Artigo em Inglês | MEDLINE | ID: mdl-2587804

RESUMO

The optimum Butterworth-Wiener filter (BWF) for the preprocessing of N-isopropyl-p-[I-123]-iodoamphetamine (I-123 IMP) SPECT was determined by a simulation experiment. Sixty-four images of the brain phantom containing 14.8 MBq of I-123 IMP were collected with a gamma camera equipped with a slant hole collimator during a 360-degree rotation. The images were processed with 27 BWFs of different shapes, followed by SPECT image reconstruction and visual comparison. The optimum BWF had a cutoff frequency of 0.25/pixel, FWHM of four pixels, and constant of 0.05. The image quality was greatly affected by the cutoff frequency of BWF used for preprocessing.


Assuntos
Encéfalo/diagnóstico por imagem , Tomografia Computadorizada de Emissão de Fóton Único/instrumentação , Criança , Filtração/instrumentação , Humanos , Masculino , Modelos Estruturais
10.
Comput Methods Programs Biomed ; 66(1): 47-54, 2001 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-11378222

RESUMO

We propose two new concepts for teleradiology: 'real-time radiology' and 'seamless operation of a workstation to view images from both local and remote hospitals'. In this paper, we describe an experimental real-time radiology system with a new multimedia diagnostic workstation, which has been established under teleradiology concepts and can be used for cooperative diagnosis by interchanging radiographic images bilaterally in real-time during an audio-visual discussion. The clinical evaluation of real-time radiology using a newly developed diagnostic workstation demonstrated the system to be practical and routinely available to enhance the radiological diagnostic quality of teleradiology.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Telerradiologia/métodos , Hospitais Universitários , Humanos , Processamento de Imagem Assistida por Computador/instrumentação , Sistemas de Informação em Radiologia/instrumentação , Telerradiologia/instrumentação
11.
Kaku Igaku ; 27(2): 93-106, 1990 Feb.
Artigo em Japonês | MEDLINE | ID: mdl-2348587

RESUMO

A consultation expert system which supports our computer aided reporting system was developed. The system was used for the evaluation of the two dimensional polar (bull's eye) display of 201Tl myocardial SPECT. The system consists of patients management (PM) and consultation expert systems (ES). The former is connected to image processors coupled with scinticameras. The bull's eye display of myocardial SPECT is transferred from image processor to the data base of PM. When inference request is made, the feature extraction program extracts information on localization, extent and severity of focal defects comparing count-rates pixel by pixel with the reference obtained from seven normal controls. The inference engine is activated to determine presence of focal defects utilizing diagnostic rules in the knowledge base. The results are sent back to PM and reported with the probability of assurance. Fifty eight patients with old myocardial infarction (OMI), angina pectoris (AP) and other diseases as well as normal controls were included in the study. The decision for presence or absence of focal defects by ES agreed with that by nuclear physicians (NP) in 301 segments among 330 (91%) in stress images. The presence of redistribution in delayed images agreed in 43 segments among 67 (64%). Image interpretation by ES agreed well with that of NP in patients with OMI (19/20) and AP (9/11). Seven were interpreted as normal by both ES and NP. The system is useful, as it provides NP with complementary and supportive information applicable to decision making and reporting. Further clinical experiences can improve knowledge base for better ES function.


Assuntos
Sistemas Inteligentes , Coração/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador , Radioisótopos de Tálio , Tomografia Computadorizada de Emissão de Fóton Único , Sistemas Computacionais , Teste de Esforço , Feminino , Cardiopatias/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA