Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 49
Filtrar
1.
J Infect Dis ; 224(8): 1325-1332, 2021 Oct 28.
Artigo em Inglês | MEDLINE | ID: mdl-34329473

RESUMO

BACKGROUND: Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) reverse-transcription polymerase chain reaction (RT-PCR) provides a highly variable cycle threshold (Ct) value that cannot distinguish viral infectivity. Subgenomic ribonucleic acid (sgRNA) has been used to monitor active replication. Given the importance of long RT-PCR positivity and the need for work reincorporation and discontinuing isolation, we studied the functionality of normalized viral loads (NVLs) for patient monitoring and sgRNA for viral infectivity detection. METHODS: The NVLs measured through the Nucleocapsid and RNA-dependent-RNA-polymerase genes and sgRNA RT-PCRs were performed in 2 consecutive swabs from 84 healthcare workers. RESULTS: The NVLs provided similar and accurate quantities of both genes of SARS-CoV-2 at 2 different timepoints of infection, overcoming Ct-value and swab collection variability. Among SARS-CoV-2-positive samples, 51.19% were sgRNA-positive in the 1st RT-PCR and 5.95% in the 2nd RT-PCR. All sgRNA-positive samples had >4 log10 RNA copies/1000 cells, whereas samples with ≤1 log10 NVLs were sgRNA-negative. Although NVLs were positive until 29 days after symptom onset, 84.1% of sgRNA-positive samples were from the first 7 days, which correlated with viral culture viability. Multivariate analyses showed that sgRNA, NVLs, and days of symptoms were significantly associated (P < .001). CONCLUSIONS: The NVLs and sgRNA are 2 rapid accessible techniques that could be easily implemented in routine hospital practice providing a useful proxy for viral infectivity and coronavirus disease 2019 patient follow-up.


Assuntos
COVID-19/diagnóstico , SARS-CoV-2/isolamento & purificação , Carga Viral/normas , Adulto , Assistência ao Convalescente/normas , COVID-19/terapia , COVID-19/transmissão , COVID-19/virologia , Teste de Ácido Nucleico para COVID-19/estatística & dados numéricos , Tomada de Decisão Clínica/métodos , Monitoramento Epidemiológico , Feminino , Pessoal de Saúde/estatística & dados numéricos , Humanos , Masculino , Pessoa de Meia-Idade , Nasofaringe/patologia , Nasofaringe/virologia , RNA Viral/isolamento & purificação , SARS-CoV-2/genética , SARS-CoV-2/patogenicidade
2.
Clin Infect Dis ; 73(Suppl_5): S472-S479, 2021 12 15.
Artigo em Inglês | MEDLINE | ID: mdl-34910176

RESUMO

BACKGROUND: Infectious diseases' outbreak investigation requires, by definition, conducting a thorough epidemiological assessment while simultaneously obtaining biological samples for an adequate screening of potential responsible pathogens. Complete autopsies remain the gold-standard approach for cause-of-death evaluation and characterization of emerging diseases. However, for highly transmissible infections with a significant associated lethality, such as COVID-19, complete autopsies are seldom performed due to biosafety challenges, especially in low-resource settings. Minimally invasive tissue sampling (MITS) is a validated new approach based on obtaining postmortem samples from key organs and body fluids, a procedure that does not require advanced biosafety measures or a special autopsy room. METHODS: We aimed to review the use of MITS or similar procedures for outbreak investigation up to 27 March 2021 and their performance for evaluating COVID-19 deaths. RESULTS: After a literature review, we analyzed in detail the results of 20 studies conducted at international sites, whereby 216 COVID-19-related deaths were investigated. MITS provided a general and more granular understanding of the pathophysiological changes secondary to the infection and high-quality samples where the extent and degree of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2)-related damage could be evaluated. CONCLUSIONS: MITS is a useful addition in the investigation and surveillance of infections occurring in outbreaks or epidemics. Its less invasive nature makes the tool more acceptable and feasible and reduces the risk of procedure-associated contagion, using basic biosafety measures. Standardized approaches protocolizing which samples should be collected-and under which exact biosafety measures-are necessary to facilitate and expand its use globally.


Assuntos
COVID-19 , Autopsia , Humanos , Pandemias , SARS-CoV-2
3.
Clin Infect Dis ; 73(Suppl_5): S454-S464, 2021 12 15.
Artigo em Inglês | MEDLINE | ID: mdl-34910166

RESUMO

BACKGROUND: Minimally invasive tissue sampling (MITS), a postmortem procedure that uses core needle biopsy samples and does not require opening the body, may be a valid alternative to complete autopsy (CA) in highly infectious diseases such as coronavirus disease-19 (COVID-19). This study aimed to (1) compare the performance of MITS and CA in a series of COVID-19 deaths and (2) evaluate the safety of the procedure. METHODS: From October 2020 to February 2021, MITS was conducted in 12 adults who tested positive before death for COVID-19, in a standard, well-ventilated autopsy room, where personnel used reinforced personal protective equipment. In 9 cases, a CA was performed after MITS. A thorough histological evaluation was conducted, and the presence of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) was evaluated by real-time reverse-transcription polymerase chain reaction (RT-PCR) and immunohistochemistry. RESULTS: The diagnoses provided by MITS and CA matched almost perfectly. In 9 patients, COVID-19 was in the chain of events leading to death, being responsible for diffuse alveolar damage and mononuclear T-cell inflammatory response in the lungs. No specific COVID-19 features were identified. Three deaths were not related to COVID-19. All personnel involved in MITS repeatedly tested negative for COVID-19. SARS-CoV-2 was identified by RT-PCR and immunohistochemistry in the MITS samples, particularly in the lungs. CONCLUSIONS: MITS is useful for evaluating COVID-19-related deaths in settings where a CA is not feasible. The results of this simplified and safer technique are comparable to those of CA.


Assuntos
COVID-19 , Autopsia , Humanos , Equipamento de Proteção Individual , Reação em Cadeia da Polimerase em Tempo Real , SARS-CoV-2
4.
BMC Infect Dis ; 21(1): 526, 2021 Jun 05.
Artigo em Inglês | MEDLINE | ID: mdl-34090384

RESUMO

BACKGROUND: Klebsiella spp. are important pathogens associated with bacteremia among admitted children and is among the leading cause of death in children < 5 years in postmortem studies, supporting a larger role than previously considered in childhood mortality. Herein, we compared the antimicrobial susceptibility, mechanisms of resistance, and the virulence profile of Klebsiella spp. from admitted and postmortem children. METHODS: Antimicrobial susceptibility and virulence factors of Klebsiella spp. recovered from blood samples collected upon admission to the hospital (n = 88) and postmortem blood (n = 23) from children < 5 years were assessed by disk diffusion and multiplex PCR. RESULTS: Klebsiella isolates from postmortem blood were likely to be ceftriaxone resistant (69.6%, 16/23 vs. 48.9%, 43/88, p = 0.045) or extended-spectrum ß-lactamase (ESBL) producers (60.9%, 14/23 vs. 25%, 22/88, p = 0.001) compared to those from admitted children. blaCTX-M-15 was the most frequent ESBL gene: 65.3%, 9/14 in postmortem isolates and 22.7% (5/22) from admitted children. We found higher frequency of genes associated with hypermucoviscosity phenotype and invasin in postmortem isolates than those from admitted children: rmpA (30.4%; 7/23 vs. 9.1%, 8/88, p = 0.011), wzi-K1 (34.7%; 8/23 vs. 8%; 7/88, p = 0.002) and traT (60.8%; 14/23 vs. 10.2%; 9/88, p < 0.0001), respectively. Additionally, serine protease auto-transporters of Enterobacteriaceae were detected from 1.8% (pic) to 12.6% (pet) among all isolates. Klebsiella case fatality rate was 30.7% (23/75). CONCLUSION: Multidrug resistant Klebsiella spp. harboring genes associated with hypermucoviscosity phenotype has emerged in Mozambique causing invasive fatal disease in children; highlighting the urgent need for prompt diagnosis, appropriate treatment and effective preventive measures for infection control.


Assuntos
Antibacterianos/farmacologia , Farmacorresistência Bacteriana Múltipla/genética , Infecções por Enterobacteriaceae/mortalidade , Klebsiella/efeitos dos fármacos , Klebsiella/genética , Fatores de Virulência/genética , Autopsia , Bacteriemia/epidemiologia , Bacteriemia/microbiologia , Pré-Escolar , Infecções por Enterobacteriaceae/microbiologia , Feminino , Humanos , Lactente , Recém-Nascido , Klebsiella/isolamento & purificação , Masculino , Testes de Sensibilidade Microbiana , Moçambique/epidemiologia , beta-Lactamases/genética
5.
J Environ Manage ; 295: 112902, 2021 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-34171775

RESUMO

While the burden of disease from well-studied drinking water contaminants is declining, risks from emerging chemical and microbial contaminants arise because of social, technological, demographic and climatological developments. At present, emerging chemical and microbial drinking water contaminants are not assessed in a systematic way, but reactively and incidence based. Furthermore, they are assessed separately despite similar pollution sources. As a result, risks might be addressed ineffectively. Integrated risk assessment approaches are thus needed that elucidate the uncertainties in the risk evaluation of emerging drinking water contaminants, while considering risk assessors' values. This study therefore aimed to (1) construct an assessment hierarchy for the integrated evaluation of the potential risks from emerging chemical and microbial contaminants in drinking water and (2) develop a decision support tool, based on the agreed assessment hierarchy, to quantify (uncertain) risk scores. A multi-actor approach was used to construct the assessment hierarchy, involving chemical and microbial risk assessors, drinking water experts and members of responsible authorities. The concept of value-focused thinking was applied to guide the problem-structuring and model-building process. The development of the decision support tool was done using Decisi-o-rama, an open-source Python library. With the developed decision support tool (uncertain) risk scores can be calculated for emerging chemical and microbial drinking water contaminants, which can be used for the evidence-based prioritisation of actions on emerging chemical and microbial drinking water risks. The decision support tool improves existing prioritisation approaches as it combines uncertain indicator levels with a multi-stakeholder approach and integrated the risk assessment of chemical and microbial contaminants. By applying the concept of value-focused thinking, this study addressed difficulties in evidence-based decision-making related to emerging drinking water contaminants. Suggestions to improve the model were made to guide future research in assisting policy makers to effectively protect public health from emerging drinking water risks.


Assuntos
Água Potável , Poluentes Químicos da Água , Monitoramento Ambiental , Políticas , Medição de Risco , Poluentes Químicos da Água/análise
6.
Artigo em Inglês | MEDLINE | ID: mdl-32122890

RESUMO

In this study, the plasmid content of clinical and commensal strains was analyzed and compared. The replicon profile was similar in both populations, except for L, M, A/C, and N (detected only in clinical strains) and HI1 (only in commensal strains). Although I1 and F were the most frequent replicons, only IncI1, sequence type 12 (ST12) was associated with blaCMY-2 in both populations. In contrast, the widespread resistant IncF plasmids were not linked to a single epidemic plasmid.


Assuntos
Proteínas de Bactérias/genética , Farmacorresistência Bacteriana/genética , Escherichia coli/genética , Klebsiella pneumoniae/genética , Plasmídeos/genética , beta-Lactamases/genética , Escherichia coli/isolamento & purificação , Fezes/microbiologia , Humanos , Klebsiella pneumoniae/isolamento & purificação , Tipagem de Sequências Multilocus
7.
Emerg Infect Dis ; 25(8): 1614-1616, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-31310211

RESUMO

We report a case of Sneathia amnii as the causative agent of maternal chorioamnionitis and congenital pneumonia resulting in a late fetal death in Mozambique, with strong supportive postmortem molecular and histopathologic confirmation. This rare, fastidious gram-negative coccobacillus has been reported to infrequently cause abortions, stillbirths, and neonatal infections.


Assuntos
Corioamnionite/diagnóstico , Corioamnionite/microbiologia , Infecções por Fusobacteriaceae/diagnóstico , Infecções por Fusobacteriaceae/microbiologia , Leptotrichia , Complicações Infecciosas na Gravidez/diagnóstico , Complicações Infecciosas na Gravidez/microbiologia , Natimorto , Adulto , Autopsia , Corioamnionite/epidemiologia , Feminino , Infecções por Fusobacteriaceae/epidemiologia , Humanos , Imuno-Histoquímica , Pulmão/microbiologia , Pulmão/patologia , Moçambique/epidemiologia , Gravidez , Complicações Infecciosas na Gravidez/epidemiologia
8.
Eur Respir J ; 54(3)2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31346005

RESUMO

Sensitive tools are needed to accurately establish the diagnosis of tuberculosis (TB) at death, especially in low-income countries. The objective of this study was to evaluate the burden of TB in a series of patients who died in a tertiary referral hospital in sub-Saharan Africa using an in-house real time PCR (TB-PCR) and the Xpert MTB/RIF Ultra (Xpert Ultra) assay.Complete diagnostic autopsies were performed in a series of 223 deaths (56.5% being HIV-positive), including 54 children, 57 maternal deaths and 112 other adults occurring at the Maputo Central Hospital, Mozambique. TB-PCR was performed in all lung, cerebrospinal fluid and central nervous system samples in HIV-positive patients. All samples positive for TB-PCR or showing histological findings suggestive of TB were analysed with the Xpert Ultra assay.TB was identified as the cause of death in 31 patients: three out of 54 (6%) children, five out of 57 (9%)maternal deaths and 23 out of 112 (21%) other adults. The sensitivity of the main clinical diagnosis to detect TB as the cause of death was 19.4% (95% CI 7.5-37.5) and the specificity was 97.4% (94.0-99.1) compared to autopsy findings. Concomitant TB (TB disease in a patient dying of other causes) was found in 31 additional cases. Xpert Ultra helped to identify 15 cases of concomitant TB. In 18 patients, Mycobacterium tuberculosis DNA was identified by TB-PCR and Xpert Ultra in the absence of histological TB lesions. Overall, 62 (27.8%) cases had TB disease at death and 80 (35.9%) had TB findings.The use of highly sensitive, easy to perform molecular tests in complete diagnostic autopsies may contribute to identifying TB cases at death that would have otherwise been missed. Routine use of these tools in certain diagnostic algorithms for hospitalised patients needs to be considered. Clinical diagnosis showed poor sensitivity for the diagnosis of TB at death.


Assuntos
Meningite/mortalidade , Tuberculose Miliar/mortalidade , Tuberculose Resistente a Múltiplos Medicamentos/mortalidade , Tuberculose Pulmonar/mortalidade , Adolescente , Adulto , Autopsia , Causas de Morte , Criança , Pré-Escolar , Feminino , Infecções por HIV/complicações , Infecções por HIV/mortalidade , Humanos , Lactente , Recém-Nascido , Masculino , Mortalidade Materna , Moçambique/epidemiologia , Mycobacterium tuberculosis , Estudos Prospectivos , Reação em Cadeia da Polimerase em Tempo Real , Centros de Atenção Terciária
9.
Malar J ; 18(1): 136, 2019 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-30999908

RESUMO

BACKGROUND: Limited health research capacities (HRC) undermine a country's ability to identify and adequately respond to local health needs. Although numerous interventions to strengthen HRC have been conducted in Africa, there is a need to share the lessons learnt by funding organizations, institutes and researchers. The aim of this report is to identify best practices in HRC strengthening by describing a training programme conducted between 2016 and 2017 at the Saint Joseph's Catholic Hospital (SJCH) in Monrovia (Liberia). METHODS: A call for trainees was launched at the SJCH, the Liberia Medicines and Health Products Regulatory Authority (LMHRA), the Ministry of Health and Social Welfare, the Mother Pattern College of Health Sciences (MPCHS) and community members. Selected trainees participated in four workshops on Good Clinical Laboratory Practice (GCLP), standard operating procedures (SOP) and scientific communication, as well as in a 5-months eLearning mentoring programme. After the training, a collectively-designed research project on malaria was conducted. RESULTS: Twenty-one of the 28 trainees (14 from the SJCH, 3 from LMHRA, one from MPCHS, and 10 community representatives) completed the programme satisfactorily. Pre- and post-training questionnaires completed by 9 of the trainees showed a 14% increase in the percentage of correct answers. Trainees participated in a mixed-methods cross-sectional study of Plasmodium falciparum infection among pregnant women at the SJCH. Selected trainees disseminated activities and research outcomes in three international meetings and three scientific publications. CONCLUSION: This training-through-research programme successfully involved SJCH staff and community members in a practical research exercise on malaria during pregnancy. The challenge is to ensure that the SJCH remains active in research. Harmonization of effectiveness indicators for HRC initiatives would strengthen the case for investing in such efforts.


Assuntos
Fortalecimento Institucional/métodos , Malária/prevenção & controle , Ensino , Atenção à Saúde/organização & administração , Mão de Obra em Saúde/organização & administração , Humanos , Libéria , Pesquisa Qualitativa
10.
PLoS Med ; 14(11): e1002431, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-29117196

RESUMO

BACKGROUND: Despite global health efforts to reduce maternal mortality, rates continue to be unacceptably high in large parts of the world. Feasible, acceptable, and accurate postmortem sampling methods could provide the necessary evidence to improve the understanding of the real causes of maternal mortality, guiding the design of interventions to reduce this burden. METHODS AND FINDINGS: The validity of a minimally invasive autopsy (MIA) method in determining the cause of death was assessed in an observational study in 57 maternal deaths by comparing the results of the MIA with those of the gold standard (complete diagnostic autopsy [CDA], which includes any available clinical information). Concordance between the MIA and the gold standard diagnostic categories was assessed by the kappa statistic, and the sensitivity, specificity, positive and negative predictive values and their 95% confidence intervals (95% CI) to identify the categories of diagnoses were estimated. The main limitation of the study is that both the MIA and the CDA include some degree of subjective interpretation in the attribution of cause of death. A cause of death was identified in the CDA in 98% (56/57) of cases, with indirect obstetric conditions accounting for 32 (56%) deaths and direct obstetric complications for 24 (42%) deaths. Nonobstetric infectious diseases (22/32, 69%) and obstetric hemorrhage (13/24, 54%) were the most common causes of death among indirect and direct obstetric conditions, respectively. Thirty-six (63%) women were HIV positive, and HIV-related conditions accounted for 16 (28%) of all deaths. Cerebral malaria caused 4 (7%) deaths. The MIA identified a cause of death in 86% of women. The overall concordance of the MIA with the CDA was moderate (kappa = 0.48, 95% CI: 0.31-0.66). Both methods agreed in 68% of the diagnostic categories and the agreement was higher for indirect (91%) than for direct obstetric causes (38%). All HIV infections and cerebral malaria cases were identified in the MIA. The main limitation of the technique is its relatively low performance for identifying obstetric causes of death in the absence of clinical information. CONCLUSIONS: The MIA procedure could be a valuable tool to determine the causes of maternal death, especially for indirect obstetric conditions, most of which are infectious diseases. The information provided by the MIA could help to prioritize interventions to reduce maternal mortality and to monitor progress towards achieving global health targets.


Assuntos
Infecções por HIV/mortalidade , Morte Materna/etiologia , Mortalidade Materna , Complicações na Gravidez/patologia , Adolescente , Adulto , Autopsia/métodos , Causas de Morte , Feminino , Infecções por HIV/diagnóstico , Humanos , Moçambique/epidemiologia , Complicações do Trabalho de Parto/diagnóstico , Complicações do Trabalho de Parto/patologia , Gravidez , Complicações na Gravidez/diagnóstico , Adulto Jovem
11.
PLoS Med ; 14(6): e1002318, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28632735

RESUMO

BACKGROUND: Over 5 million stillbirths and neonatal deaths occur annually. Limited and imprecise information on the cause of these deaths hampers progress in achieving global health targets. Complete diagnostic autopsies (CDAs)-the gold standard for cause of death determination-are difficult to perform in most high-burden settings. Therefore, validation of simpler and more feasible methods is needed. METHODS AND FINDINGS: In this observational study, the validity of a minimally invasive autopsy (MIA) method in determining the cause of death was assessed in 18 stillbirths and 41 neonatal deaths by comparing the results of the MIA with those of the CDA. Concordance between the categories of diseases obtained by the 2 methods was assessed by the Kappa statistic, and the sensitivity, specificity, positive, and negative predictive values of the MIA diagnoses were calculated. A cause of death was identified in 16/18 (89%) and 15/18 (83%) stillborn babies in the CDA and the MIA, respectively. Fetal growth restriction accounted for 39%, infectious diseases for 22%, intrapartum hypoxia for 17%, and intrauterine hypoxia for 11% of stillborn babies. Overall, the MIA showed in this group a substantial concordance with the CDA (Kappa = 0.78, 95% CI [0.56-0.99]). A cause of death was identified in all (100%) and 35/41 (85%) neonatal deaths in the CDA and the MIA, respectively. In this group, the majority of deaths were due to infectious diseases (66%). The overall concordance of the MIA with the CDA in neonates was moderate (Kappa = 0.40, 95% CI [0.18-0.63]). A high percentage of accuracy was observed for the MIA in all the diagnostic categories in both stillbirths and neonates (>75%). The main limitation of this study is that some degree of subjective interpretation is inherent to cause-of-death attribution in both the MIA and the CDA; this is especially so in stillbirths and in relation to fetal growth restriction. CONCLUSIONS: The MIA could be a useful tool for cause-of-death determination in stillbirths and neonatal deaths. These findings may help to accelerate progress towards meeting global health targets by obtaining more accurate information on the causes of death in these age groups, which is essential in guiding the design of new interventions and increasing the effectiveness of those already implemented.


Assuntos
Autopsia/métodos , Causas de Morte , Natimorto , Autopsia/instrumentação , Autopsia/normas , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Moçambique , Sensibilidade e Especificidade
12.
PLoS Med ; 14(6): e1002317, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28632739

RESUMO

BACKGROUND: In recent decades, the world has witnessed unprecedented progress in child survival. However, our knowledge of what is killing nearly 6 million children annually in low- and middle-income countries remains poor, partly because of the inadequacy and reduced precision of the methods currently utilized in these settings to investigate causes of death (CoDs). The study objective was to validate the use of a minimally invasive autopsy (MIA) approach as an adequate and more acceptable substitute for the complete diagnostic autopsy (CDA) for pediatric CoD investigation in a poor setting. METHODS AND FINDINGS: In this observational study, the validity of the MIA approach in determining the CoD was assessed in 54 post-neonatal pediatric deaths (age range: ≥1 mo to 15 y) in a referral hospital of Mozambique by comparing the results of the MIA with those of the CDA. Concordance in the category of disease obtained by the two methods was evaluated by the Kappa statistic, and the sensitivity, specificity, and positive and negative predictive values of the MIA diagnoses were calculated. A CoD was identified in all cases in the CDA and in 52/54 (96%) of the cases in the MIA, with infections and malignant tumors accounting for the majority of diagnoses. The MIA categorization of disease showed a substantial concordance with the CDA categorization (Kappa = 0.70, 95% CI 0.49-0.92), and sensitivity, specificity, and overall accuracy were high. The ICD-10 diagnoses were coincident in up to 75% (36/48) of the cases. The MIA allowed the identification of the specific pathogen deemed responsible for the death in two-thirds (21/32; 66%) of all deaths of infectious origin. Discrepancies between the MIA and the CDA in individual diagnoses could be minimized with the addition of some basic clinical information such as those ascertainable through a verbal autopsy or clinical record. The main limitation of the analysis is that both the MIA and the CDA include some degree of expert subjective interpretation. CONCLUSIONS: The MIA showed substantial concordance with CDA for CoD identification in this series of pediatric deaths in Mozambique. This minimally invasive approach, simpler and more readily acceptable than the more invasive CDA, could provide robust data for CoD surveillance, especially in resource-limited settings, which could be helpful for guiding child survival strategies in the future.


Assuntos
Autopsia/instrumentação , Causas de Morte , Adolescente , Criança , Mortalidade da Criança , Pré-Escolar , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Moçambique , Sensibilidade e Especificidade
13.
Artigo em Inglês | MEDLINE | ID: mdl-27919890

RESUMO

Seventy-two (54.5%) out of 132 fecal samples from a group of yellow-legged gulls in Barcelona, Spain, were positive for Escherichia coli producing either extended-spectrum ß-lactamases (ESBL) (51.5%), carbapenemase (1.5%), or cephamycinase (1.5%). The isolation of two carbapenemase-producing E. coli strains is a matter of concern.


Assuntos
Proteínas de Bactérias/metabolismo , Charadriiformes/microbiologia , Escherichia coli/enzimologia , beta-Lactamases/metabolismo , Animais , Espanha
14.
PLoS Med ; 13(11): e1002171, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27875530

RESUMO

BACKGROUND: There is an urgent need to identify tools able to provide reliable information on the cause of death in low-income regions, since current methods (verbal autopsy, clinical records, and complete autopsies) are either inaccurate, not feasible, or poorly accepted. We aimed to compare the performance of a standardized minimally invasive autopsy (MIA) approach with that of the gold standard, the complete diagnostic autopsy (CDA), in a series of adults who died at Maputo Central Hospital in Mozambique. METHODS AND FINDINGS: In this observational study, coupled MIAs and CDAs were performed in 112 deceased patients. The MIA analyses were done blindly, without knowledge of the clinical data or the results of the CDA. We compared the MIA diagnosis with the CDA diagnosis of cause of death. CDA diagnoses comprised infectious diseases (80; 71.4%), malignant tumors (16; 14.3%), and other diseases, including non-infectious cardiovascular, gastrointestinal, kidney, and lung diseases (16; 14.3%). A MIA diagnosis was obtained in 100/112 (89.2%) cases. The overall concordance between the MIA diagnosis and CDA diagnosis was 75.9% (85/112). The concordance was higher for infectious diseases and malignant tumors (63/80 [78.8%] and 13/16 [81.3%], respectively) than for other diseases (9/16; 56.2%). The specific microorganisms causing death were identified in the MIA in 62/74 (83.8%) of the infectious disease deaths with a recognized cause. The main limitation of the analysis is that both the MIA and the CDA include some degree of expert subjective interpretation. CONCLUSIONS: A simple MIA procedure can identify the cause of death in many adult deaths in Mozambique. This tool could have a major role in improving the understanding and surveillance of causes of death in areas where infectious diseases are a common cause of mortality.


Assuntos
Autopsia/métodos , Causas de Morte , Adolescente , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Moçambique , Adulto Jovem
15.
BMC Infect Dis ; 15: 44, 2015 Feb 06.
Artigo em Inglês | MEDLINE | ID: mdl-25656393

RESUMO

BACKGROUND: Influenza virus infections are responsible for significant morbidity and mortality in both pediatric and adult populations worldwide. Rapid and accurate diagnosis of influenza is necessary for appropriate patient management during the influenza season and for optimal utilization of anti-influenza therapy. We prospectively tested the accuracy of a simple and rapid diagnostic method. METHODS: Ninety-eight samples (nasal and pharyngeal swabs) from patients with upper respiratory tract infection symptoms who presented to primary healthcare centres in Barcelona (Spain) were prospectively analyzed. The samples were collected as part of influenza surveillance program. Samples that had enough volume to make the new test after aliquoting the amount needed to perform routine tests were included. None of the samples were pre-selected as a result of their status in relation to influenza virus. Samples were analyzed by in-house real-time PCR and Alere i Influenza A & B (Alere i), which uses isothermal amplification of nucleic acids for the qualitative detection of influenza A and B in nasal swabs transported in viral transport media. The two techniques were compared by positive percent agreement (PPA) and negative percent agreement (NPA). Statistical analysis was performed with Stata. RESULTS: Of the 98 samples analysed 90 were concordant; 46 (46.9%) were positive and 44 (44.9%) were negative. Five samples showed invalid results with the Alere i test and could be not re-tested due to insufficient sample volume and were not included in the final statistical analysis. In the 93 remaining samples, the Alere i test showed 97% of accuracy having correctly classified 90 samples. We obtained discordant results in 3 samples (3%). The PPA was 93.8% for influenza A and 94.1% for influenza B, and NPA was 100% for influenza A and influenza B virus. In addition, the Alere i was very rapid (15 minutes or less) and extremely easy to use. CONCLUSIONS: The Alere i test provided a good correlation compared to the real-time PCR test for the diagnosis of influenza. Since this method can be performed in minutes, it allows immediate, accurate clinical decisions to prescribe appropriate antiviral treatment or isolation of patients.


Assuntos
Vírus da Influenza A/isolamento & purificação , Vírus da Influenza B/isolamento & purificação , Influenza Humana/diagnóstico , Técnicas de Amplificação de Ácido Nucleico/métodos , Adulto , Criança , Humanos , Vírus da Influenza A/genética , Vírus da Influenza B/genética , Influenza Humana/epidemiologia , Influenza Humana/virologia , Nariz/virologia , Faringe/virologia , RNA Viral/genética , RNA Viral/isolamento & purificação , Reação em Cadeia da Polimerase em Tempo Real , Sensibilidade e Especificidade , Espanha/epidemiologia , Fatores de Tempo
16.
Microbiol Spectr ; : e0425622, 2023 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-36975992

RESUMO

Currently, a rapid detection of SARS-CoV-2 in clinical settings such as patients from emergency surgery is needed. The QuantuMDx Q-POC assay is a real-time-PCR test that was created for the rapid detection of SARS-CoV-2 in only 30 min. This study aimed to compare QuantuMDx Q-POC with our standard algorithm with Cobas 6800 for SARS-CoV-2 detection. The samples were run in parallel in both platforms. First, a comparison analysis was carried out. Second, the limit of detection was determinate in both platforms using a serial dilution of SARS-CoV-2 inactivated virus. A total of 234 samples were analyzed. For a Ct <30, the sensitivity and specificity was 100.0% and 92.5%, respectively. Positive predictive value was 86.2% and negative predictive value was 100.0%. Both COBAS 6800 and QuantuMDx Q-POC could detect up to 100 copies/mL. The QuantuMDx Q-POC system it is a reliable option when a rapid detection of SARS-CoV-2 is necessary. IMPORTANCE In different health care settings, such as patients from emergency surgery, rapid detection of SARS-CoV-2 is needed. The QuantuMDx Q-POC is an automatized fast workflow platform based on detection of three genes: two genes encoding structural proteins that can be used to differentiate SARS-CoV-2 from other coronavirus and a third target gene encoding a nonstructural region that is unique for SARS-CoV-2 such as the open reading frame (ORF1). This assay enables a rapid detection of SARS-CoV-2 with a high sensitivity in a short time frame (30 min). Therefore, QuantuMDx is a simple, rapid and easy SARS-CoV-2 detection test from direct middle nasal swabs.

17.
Eur Respir Rev ; 31(166)2022 Dec 31.
Artigo em Inglês | MEDLINE | ID: mdl-36261158

RESUMO

Respiratory virus infection can cause severe illnesses capable of inducing acute respiratory failure that can progress rapidly to acute respiratory distress syndrome (ARDS). ARDS is related to poor outcomes, especially in individuals with a higher risk of infection, such as the elderly and those with comorbidities, i.e. obesity, asthma, diabetes mellitus and chronic respiratory or cardiovascular disease. Despite this, effective antiviral treatments available for severe viral lung infections are scarce. The coronavirus disease 2019 (COVID-19) pandemic demonstrated that there is also a need to understand the role of airborne transmission of respiratory viruses. Robust evidence supporting this exists, but better comprehension could help implement adequate measures to mitigate respiratory viral infections. In severe viral lung infections, early diagnosis, risk stratification and prognosis are essential in managing patients. Biomarkers can provide reliable, timely and accessible information possibly helpful for clinicians in managing severe lung viral infections. Although respiratory viruses highly impact global health, more research is needed to improve care and prognosis of severe lung viral infections. In this review, we discuss the epidemiology, diagnosis, clinical characteristics, management and prognosis of patients with severe infections due to respiratory viruses.


Assuntos
COVID-19 , Síndrome do Desconforto Respiratório , Vírus , Humanos , Idoso , SARS-CoV-2 , Antivirais/uso terapêutico , Biomarcadores
19.
Microbiol Spectr ; 10(2): e0235121, 2022 04 27.
Artigo em Inglês | MEDLINE | ID: mdl-35293799

RESUMO

Microbiological diagnosis of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has been a challenge. Although real-time reverse transcription PCR (RT-PCR) represents the gold standard method, strategies that allow rapid and simple diagnosis are necessary for the early identification of cases. In this study, we evaluated the diagnostic performance of six different commercial rapid antigen tests (Coronavirus antigen [Ag] rapid test cassette [Healgen Scientific, Houston, TX, USA], COVID-19 Ag FIA [Vircell, SD Biosensor Inc., Gyeonggi-do, Republic of Korea], Clinitest rapid COVID-19 antigen test [Siemens, Healthineers, Erlangen, Germany], SARS-CoV-2 rapid antigen test [SD Biosensor; Roche Diagnostics, Basel, Switzerland], Panbio COVID-19 Ag rapid test device [Abbott, Chicago, IL, USA], and SARS-CoV-2 test [MonLab, Barcelona, Spain]) in 130 nasopharyngeal swab samples tested previously by RT-PCR. The overall sensitivity of the rapid tests ranged from 65% to 79%, and the specificity was 100% for all of them. The sensitivity was higher for those samples with RT-PCR cycle threshold (CT) values below 25 and those from patients presenting within the first week of symptoms. The Siemens test showed the highest sensitivity for patients with high viral loads while the Vircell test performed better than the rest for CT values of ≥25. IMPORTANCE The rapid detection of people infected with SARS-CoV-2 is essential for a correct and effective control of the disease it causes. This process must be sensitive, fast, and simple, and it must be possible to carry out in any type of health center. Rapid antigen tests are the answer to this need. Knowing its ability to detect the virus in different stages of the disease is essential for a correct diagnosis, which is why this study has been carried out to evaluate the sensitivity and specificity of 6 different antigens tests in nasopharyngeal smear samples.


Assuntos
COVID-19 , SARS-CoV-2 , Antígenos Virais/análise , COVID-19/diagnóstico , Teste para COVID-19 , Humanos , Reação em Cadeia da Polimerase em Tempo Real
20.
Infect Dis Ther ; 11(1): 587-593, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34762246

RESUMO

The immense impact of the COVID-19 pandemic on health systems has motivated the scientific community to search for clinical prognostic factors for SARS-CoV-2 infection. Low cycle threshold values (Ct) of diagnostic real-time RT-PCR assays in hospitalized patients have been associated with a poor prognosis in several studies, whereas other studies did not find this association. We explored whether SARS-CoV-2 Ct values at diagnosis were associated with a poor outcome (admission to hospital and death) in 604 community patients diagnosed at primary health centers. Although lower Ct values were found in patients who died of COVID-19, the Ct value was not significantly associated with a worse outcome in a multivariate analysis, while age remained an independent prognostic factor. We did not find evidence to support the role of Ct values as a prognostic factor of COVID-19 in community cases.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA