Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Pharm Res ; 41(3): 501-512, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38326530

RESUMO

PURPOSE: This study aimed to test the feasibility of using Small Angle X-ray Scattering (SAXS) coupled with Density from Solution Scattering (DENSS) algorithm to characterize the internal architecture of messenger RNA-containing lipid nanoparticles (mRNA-LNPs). METHODS: The DENSS algorithm was employed to construct a three-dimensional model of average individual mRNA-LNP. The reconstructed models were cross validated with cryogenic transmission electron microscopy (cryo-TEM), and dynamic light scattering (DLS) to assess size, morphology, and internal structure. RESULTS: Cryo-TEM and DLS complemented SAXS, revealed a core-shell mRNA-LNP structure with electron-rich mRNA-rich region at the core, surrounded by lipids. The reconstructed model, utilizing the DENSS algorithm, effectively distinguishes mRNA and lipids via electron density mapping. Notably, DENSS accurately models the morphology of the mRNA-LNPs as an ellipsoidal shape with a "bleb" architecture or a two-compartment structure with contrasting electron densities, corresponding to mRNA-filled and empty lipid compartments, respectively. Finally, subtle changes in the LNP structure after three freeze-thaw cycles were detected by SAXS, demonstrating an increase in radius of gyration (Rg) associated with mRNA leakage. CONCLUSION: Analyzing SAXS profiles based on DENSS algorithm to yield a reconstructed electron density based three-dimensional model can be a useful physicochemical characterization method in the toolbox to study mRNA-LNPs and facilitate their development.


Assuntos
Elétrons , Lipossomos , Nanopartículas , Raios X , Espalhamento a Baixo Ângulo , RNA Mensageiro/química , Difração de Raios X , Nanopartículas/química , Lipídeos/química , RNA Interferente Pequeno/química
2.
Surg Endosc ; 38(8): 4329-4335, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38874609

RESUMO

BACKGROUND: Liver surgery is associated with a significant hospital stay regardless the type of liver resection. A large incision is essential for open liver surgery which is a major factor in the course of the patient's recovery. For patients with small parenchyma liver lesions requiring surgical resection, robotic surgery potentially offers the opportunity to transform the patient's post-operative course. A day-case robotic liver resection pathway was formulated and implemented at our institution when patients were planned for discharge within 24 h of admission for liver surgery. METHODS: Single surgeon case series of cases performed at a tertiary hepatobiliary and pancreatic centre between September 2022 and November 2023. The inclusion criteria were non-anatomical wedge resections, < 2 anatomical segmental resections, left lateral hepatectomy and minimally invasive surgery. RESULTS: This is the first series of robotic day-case minor liver resection in the United Kingdom. 20 patients were included in this case series. The mean operative time was 86.6 ± 30.9 min and mean console time was 58.6 ± 24.5 min. Thirteen patients (65%) were discharged within 24 h of surgery. The main cause of hospitalisation beyond 24 h was inadequate pain relief. There were no Clavien-Dindo grade III or above complications, no 30-day readmission and 90-day mortalities. CONCLUSION: This case series demonstrates that robotic day-case liver resection is safe and feasible. Robust follow-up pathways must be in place to allow for the safe implementation of this approach, to monitor for any complications and to allow intervention as required in a timely manner.


Assuntos
Procedimentos Cirúrgicos Ambulatórios , Hepatectomia , Duração da Cirurgia , Procedimentos Cirúrgicos Robóticos , Humanos , Procedimentos Cirúrgicos Robóticos/métodos , Hepatectomia/métodos , Feminino , Pessoa de Meia-Idade , Masculino , Idoso , Procedimentos Cirúrgicos Ambulatórios/métodos , Tempo de Internação/estatística & dados numéricos , Adulto , Centros de Atenção Terciária
3.
ACS Appl Mater Interfaces ; 16(5): 5598-5612, 2024 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-38270979

RESUMO

Imaging plays a critical role in all stages of cancer care from early detection to diagnosis, prognosis, and therapy monitoring. Recently, photoacoustic imaging (PAI) has started to emerge into the clinical realm due to its high sensitivity and ability to penetrate tissues up to several centimeters deep. Herein, we encapsulated indocyanine green J (ICGJ) aggregate, one of the only FDA-approved organic exogenous contrast agents that absorbs in the near-infrared range, at high loadings up to ∼40% w/w within biodegradable polymersomes (ICGJ-Ps) composed of poly(lactide-co-glycolide-b-polyethylene glycol) (PLGA-b-PEG). The small Ps hydrodynamic diameter of 80 nm is advantageous for in vivo applications, while directional conjugation with epidermal growth factor receptor (EGFR) targeting cetuximab antibodies renders molecular specificity. Even when exposed to serum, the ∼11 nm-thick membrane of the Ps prevents dissociation of the encapsulated ICGJ for at least 48 h with a high ratio of ICGJ to monomeric ICG absorbances (i.e., I895/I780 ratio) of approximately 5.0 that enables generation of a strong NIR photoacoustic (PA) signal. The PA signal of polymersome-labeled breast cancer cells is proportional to the level of cellular EGFR expression, indicating the feasibility of molecular PAI with antibody-conjugated ICGJ-Ps. Furthermore, the labeled cells were successfully detected with PAI in highly turbid tissue-mimicking phantoms up to a depth of 5 mm with the PA signal proportional to the amount of cells. These data show the potential of molecular PAI with ICGJ-Ps for clinical applications such as tumor margin detection, evaluation of lymph nodes for the presence of micrometastasis, and laparoscopic imaging procedures.


Assuntos
Imunoconjugados , Técnicas Fotoacústicas , Verde de Indocianina/química , Meios de Contraste/química , Análise Espectral , Imagem Molecular , Receptores ErbB , Técnicas Fotoacústicas/métodos
4.
Biomed Mater ; 16(4)2021 05 04.
Artigo em Inglês | MEDLINE | ID: mdl-33857922

RESUMO

Several biofabrication methods are being investigated to produce scaffolds that can replicate the structure of the extracellular matrix. Direct-write, near-field electrospinning of polymer solutions and electrowriting of polymer melts are methods which combine fine fiber formation with computer-guided control. Research with such systems has focused primarily on synthetic polymers. To better understand the behavior of biopolymers used for direct-writing, this project investigated changes in fiber morphology, size, and variability caused by varying gelatin and acetic acid concentration, as well as process parameters such as needle gauge and height, stage speed, and interfiber spacing. Increasing gelatin concentration at a constant acetic acid concentration improved fiber morphology from large, planar structures to small, linear fibers with a median of 2.3 µm. Further varying the acetic acid concentration at a constant gelatin concentration did not alter fiber morphology and diameter throughout the range tested. Varying needle gauge and height further improved the median fiber diameter to below 2 µm and variability of the first and third quartiles to within ±1 µm of the median. Additional adjustment of stage speed did not impact the fiber morphology or diameter. Repeatable interfiber spacings down to 250 µm were shown to be capable with the system. In summary, this study illustrates the optimization of processing parameters for direct-writing of gelatin to produce fibers on the scale of collagen fibers. This system is thus capable of replicating the fibrous structure of musculoskeletal tissues with biologically relevant materials which will provide a durable platform for the analysis of single cell-fiber interactions to help better understand the impact scaffold materials and dimensions have on cell behavior.


Assuntos
Técnicas Eletroquímicas/métodos , Gelatina/química , Nanofibras/química , Alicerces Teciduais/química , Biopolímeros/química , Nanotecnologia , Engenharia Tecidual
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA