Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 249
Filtrar
Mais filtros

Tipo de documento
Intervalo de ano de publicação
1.
Lancet ; 403(10445): 2695-2708, 2024 Jun 22.
Artigo em Inglês | MEDLINE | ID: mdl-38795719

RESUMO

BACKGROUND: Transcatheter aortic valve implantation is an established, guideline-endorsed treatment for severe aortic stenosis. Precise sizing of the balloon-expandable Myval transcatheter heart valve (THV) series with the aortic annulus is facilitated by increasing its diameter in 1·5 mm increments, compared with the usual 3 mm increments in valve size. The LANDMARK trial aimed to show non-inferiority of the Myval THV series compared with the contemporary THVs Sapien Series (Edwards Lifesciences, Irvine, CA, USA) or Evolut Series (Medtronic, Minneapolis, MN, USA). METHODS: In this prospective, multinational, randomised, open-label, non-inferiority trial across 31 hospitals in 16 countries (Germany, France, Sweden, the Netherlands, Italy, Spain, New Zealand, Portugal, Greece, Hungary, Poland, Slovakia, Slovenia, Croatia, Estonia, and Brazil), 768 participants with severe symptomatic native aortic stenosis were randomly assigned (1:1) to the Myval THV or a contemporary THV. Eligibility was primarily decided by the heart team in accordance with 2021 European Society of Cardiology guidelines. As per the criteria of the third Valve Academic Research Consortium, the primary endpoint at 30 days was a composite of all-cause mortality, all stroke, bleeding (types 3 and 4), acute kidney injury (stages 2-4), major vascular complications, moderate or severe prosthetic valve regurgitation, and conduction system disturbances resulting in a permanent pacemaker implantation. Non-inferiority of the study device was tested in the intention-to-treat population using a non-inferiority margin of 10·44% and assuming an event rate of 26·10%. This trial is registered with ClinicalTrials.gov, NCT04275726, and EudraCT, 2020-000137-40, and is closed to new participants. FINDINGS: Between Jan 6, 2021, and Dec 5, 2023, 768 participants with severe symptomatic native aortic stenosis were randomly assigned, 384 to the Myval THV and 384 to a contemporary THV. 369 (48%) participants had their sex recorded as female, and 399 (52%) as male. The mean age of participants was 80·0 years (SD 5·7) for those treated with the Myval THV and 80·4 years (5·4) for those treated with a contemporary THV. Median Society of Thoracic Surgeons scores were the same in both groups (Myval 2·6% [IQR 1·7-4·0] vs contemporary 2·6% [1·7-4·0]). The primary endpoint showed non-inferiority of the Myval (25%) compared with contemporary THV (27%), with a risk difference of -2·3% (one-sided upper 95% CI 3·8, pnon-inferiority<0·0001). No significant difference was seen in individual components of the primary composite endpoint. INTERPRETATION: In individuals with severe symptomatic native aortic stenosis, the Myval THV met its primary endpoint at 30 days. FUNDING: Meril Life Sciences.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Complicações Pós-Operatórias/epidemiologia , Estudos Prospectivos , Desenho de Prótese , Índice de Gravidade de Doença , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento
2.
Eur J Clin Invest ; 54(8): e14209, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38597271

RESUMO

BACKGROUND: In the last few years, percutaneous LAA occlusion (LAAO) has become a plausible alternative in atrial fibrillation (AF) patients with contraindications to anticoagulation therapy. Nevertheless, the optimal antiplatelet strategy following percutaneous LAAO remains to be defined. METHODS: Studies comparing single antiplatelet therapy (SAPT) versus dual antiplatelet therapy (DAPT) following LAAO were systematically searched and screened. The outcomes of interest were ischemic stroke, device-related thrombus (DRT) and major bleeding. A random-effect meta-analysis was performed comparing outcomes in both groups. The moderator effect of baseline characteristics on outcomes was evaluated by univariate meta-regression analyses. RESULTS: Sixteen observational studies with 3255 patients treated with antiplatelet therapy (SAPT, n = 1033; DAPT, n = 2222) after LAAO were included. Mean age was 74.5 ± 8.3 years, mean CHA2DS2-VASc and HAS-BLED scores were 4.3 ± 1.5 and 3.2 ± 1.0, respectively. At a weighted mean follow-up of 12.7 months, the occurrence of stroke (RR 1.33; 95% CI 0.64-2.77; p =.44), DRT (RR 1.52; 95% CI 0.90-2.58; p =.12), and the composite of stroke and DRT (RR 1.26; 95% CI 0.67-2.37; p =.47) did not differ significantly between SAPT and DAPT groups. The rate of major bleedings was also not different between groups (RR 1.41; 95% CI 0.64-3.12; p =.39). CONCLUSIONS: Among AF patients at high bleeding risk undergoing percutaneous LAAO, a post-procedural minimalistic antiplatelet strategy with SAPT did not significantly differ from DAPT regimens regarding the rate of stroke, DRT and major bleeding.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Terapia Antiplaquetária Dupla , Hemorragia , Inibidores da Agregação Plaquetária , Humanos , Apêndice Atrial/cirurgia , Inibidores da Agregação Plaquetária/uso terapêutico , Terapia Antiplaquetária Dupla/métodos , Hemorragia/induzido quimicamente , Idoso , Trombose/prevenção & controle , AVC Isquêmico/prevenção & controle , Acidente Vascular Cerebral/prevenção & controle , Estudos Observacionais como Assunto , Oclusão do Apêndice Atrial Esquerdo
3.
Artigo em Inglês | MEDLINE | ID: mdl-38959377

RESUMO

BACKGROUND: The treatment of resistant coronary lesions (RCL) is a great challenge for interventional cardiologists. The excimer laser coronary atherectomy (ELCA) is a plaque modification tool based on a main mechanism of photomechanical effect leading to mechanical disruption of the plaque. Contrast dye injection during laser delivery has demonstrated to enhance its power. AIM: To evaluate the effectiveness and safety of the contrast-enhanced ELCA by a stepwise approach in the treatment of RCLs. METHODS: We retrospectively examined consecutive patients undergoing contrast-enhanced ELCA-assisted PCI between 2018 and 2021 at two Italian sites. RCLs were defined as novo or in-stent undilatable/uncrossable with conventional balloons (SC/NC balloon). The primary endpoint was ELCA technical success defined as the laser catheter crossing the entire length of the target lesion established by angiographic evidence of the catheter tip in the artery distal to the stenosis. RESULTS: We enrolled 114 patients who underwent contrast-enhanced ELCA-assisted PCI: 58% of the patients had acute coronary syndrome while the left anterior descending artery was the target vessel in 42.1% of cases. The target lesion was most commonly in-stent (56.2%). The 0.9 mm ELCA catheter tip was employed in 89.5% of cases. The most used frequency/fluency profile was 70/70 (39.5%). The use of contrast-enhanced ELCA was associated with high technical, procedural, and clinical success rates (97.4%, 93.7%, and 90.1%, respectively). CONCLUSIONS: The contrast-enhanced ELCA seems to be a safe and effective treatment option for the management of both de novo and in-stent-resistant coronary lesions.

4.
Am Heart J ; 264: 72-82, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37279839

RESUMO

BACKGROUND: Little data exist on the relationship between total stent length (TSL) and cardiovascular outcomes at very-long follow-up in patients with ST-elevation myocardial infarction (STEMI) in the 2nd generation drug-eluting stents (DES) era. AIM: To analyze the relationship between TSL and 10-year target-lesion failure (TLF) in STEMI patients treated with percutaneous coronary intervention enrolled in the EXAMINATION-EXTEND. METHODS: The EXAMINATION-EXTEND was an extended-follow-up study of the EXAMINATION trial, which randomized 1:1 STEMI patients to receive DES or bare metal stent (BMS). The primary endpoint was TLF, defined as a composite of target lesion revascularization (TLR), target vessel myocardial infarction (TVMI), or definite/probable stent thrombosis (ST). Relationship between stent length and TLF was evaluated in the whole study group in a multiple-adjusted Cox regression model with TSL as a quantitative variable. Subgroup analysis was also performed according to stent type, diameter, and overlap. RESULTS: A total of 1,489 patients with a median TSL of 23 mm (Q1-Q318-35 mm) were included. TSL was associated with TLF at 10 years (adjusted HR per 5 mm increase of 1.07; 95% CI, 1.01-1.14; P = .02). This effect was mainly driven by TLR and was consistent regardless of stent type, diameter, or overlap. There was no significant relationship between TSL and TV-MI or ST. CONCLUSIONS: In STEMI patients, there is a direct relationship between TSL implanted in the culprit vessel and the risk of TLF at 10 years, mainly driven by TLR. The use of DES did not modify this association.


Assuntos
Fármacos Cardiovasculares , Stents Farmacológicos , Intervenção Coronária Percutânea , Infarto do Miocárdio com Supradesnível do Segmento ST , Humanos , Infarto do Miocárdio com Supradesnível do Segmento ST/cirurgia , Seguimentos , Resultado do Tratamento , Stents , Desenho de Prótese
5.
Catheter Cardiovasc Interv ; 102(7): 1364-1375, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37698335

RESUMO

BACKGROUND: Extremely large aortic valve anatomy is one of the remaining limitations leading to exclusion of patients for transcatheter aortic valve replacement (TAVR). AIMS: The newly approved Myval 32 mm device is designed for use in aortic annulus areas up to 840 mm2 . Here we want to share the initial worldwide experience with the device. METHODS AND RESULTS: Retrospective data were collected from 10 patients with aortic stenosis and very large annular anatomy (mean area 765.5 mm2 ), who underwent implantation with 32 mm Myval transcatheter heart valve at eight centers. Valve Academic Research Consortium-2 device success was achieved in all cases. Mild paravalvular leak was observed in three patients and two patients required new pacemaker implantation. One patient experienced retroperitoneal hemorrhage caused by the contralateral 6 F sheath and required surgical revision. No device-related complications, stroke, or death from any cause occurred within the 30-day follow-up period. In a studied cohort of 2219 consecutive TAVR-screened patients from a central European site, only 0.27% of patients showed larger anatomy than covered by the 32 mm Myval device by instructions for use without off-label use of overexpansion. This rate was significantly higher for the 34 mm Evolut Pro (1.8%) and 29 mm Sapien 3 (2.1%) devices. CONCLUSIONS: The Myval 32 mm prosthesis showed promising initial results in a cohort of patients who previously had to be excluded from TAVR. It is desirable that all future TAVR systems accommodate larger anatomy to allow optimal treatment of all patients.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Estudos Retrospectivos , Resultado do Tratamento , Desenho de Prótese , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter/efeitos adversos
6.
Catheter Cardiovasc Interv ; 102(5): 931-943, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37668097

RESUMO

BACKGROUND: Evidence of clinical impact of PPM after TAVI is conflicting and might vary according to the type of valve implanted. AIMS: To assess the clinical impact of prosthesis-patient mismatch (PPM) after transcatheter aortic valve implantation (TAVI) with balloon-expandable (BEV) and self-expandable valves (SEV) in patients with small annuli. METHODS: TAVI-SMALL 2 enrolled 628 patients in an international retrospective registry, which included patients with severe aortic stenosis and small annuli (annular perimeter <72 mm or area <400 mm2 ) treated with transfemoral TAVI at 16 high-volume centers between 2011 and 2020. Analyses were performed comparing patients with less than moderate (n = 452), moderate (n = 138), and severe PPM (n = 38). Primary endpoint was incidence of all-cause mortality. Predictors of all-cause mortality and PPM were investigated. RESULTS: At a median follow-up of 380 days (interquartile range: 210-709 days), patients with severe PPM, but not moderate PPM, had an increased risk of all-cause mortality when compared with less than moderate PPM (log-rank p = 0.046). Severe PPM predicted all-cause mortality in patients with BEV (hazard ratio [HR]: 5.20, 95% confidence interval [CI]: 1.27-21.2) and intra-annular valves (IAVs, HR: 4.23, 95% CI: 1.28-14.02), and it did so with borderline significance in the overall population (HR: 2.89, 95% CI: 0.95-8.79). Supra-annular valve (SAV) implantation was the only predictor of severe PPM (odds ratio: 0.33, 95% CI: 0.13-0.83). CONCLUSIONS: Patients with small aortic annuli and severe PPM after TAVI have an increased risk of all-cause mortality at early term follow-up, especially after IAV or BEV implantation. TAVI with SAV protected from severe PPM.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/etiologia , Estudos Retrospectivos , Desenho de Prótese , Resultado do Tratamento , Substituição da Valva Aórtica Transcateter/efeitos adversos
7.
Eur Heart J Suppl ; 25(Suppl C): C79-C83, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37125288

RESUMO

True coronary bifurcation lesions (CBL) represent a challenging scenario for percutaneous coronary interventions (PCI), and are associated with a higher risk of target lesion failure (TLF), particularly when two stents are implanted. A hybrid strategy combining a drug-eluting stent (DES) in the main branch, and a drug-coated balloon in the side branch may improve outcomes by reducing the total stent length while maintaining an effective anti-prolipherative action. In this sub-study of the HYPER trial, 50 patients with true CBL were treated with a hybrid strategy: procedural success was 96%, one case of peri-procedural myocardial infarction and one case of TLF (in a DES-treated segment) at 1 year were reported. This study suggests that such a hybrid strategy may be a safe and effective option for true CBL PCI, and warrants additional investigations to compare outcomes with standard of care strategies.

8.
Artigo em Inglês | MEDLINE | ID: mdl-36525378

RESUMO

OBJECTIVES: To explore the long-term clinical outcomes following intravascular lithotripsy (IVL) in calcified coronary lesions from a real-world population. BACKGROUND: IVL is a relatively new but promising modality for treating coronary calcified lesions, but there is a dearth of long-term outcome data from real-world patients. METHODS: This was a multicenter, observational study in which we enrolled all patients treated with IVL from November 2018 to February 2021 from eight centers in Europe and the United Kingdom. Procedural success, complications, and clinical outcomes (cardiac death, target vessel myocardial infarction [TVMI], target lesion revascularization [TLR], and MACE [major adverse cardiac events, the composite of cardiac death, TVMI, and TLR]) were assessed. RESULTS: In total, 273 patients with a mean age of 72 ± 9.1 years were treated with IVL. Major comorbidities included diabetes mellitus (n = 110, 40%) and chronic kidney disease (n = 45, 16%). Acute coronary syndrome accounted for 48% (n = 132) of patients, while 52% (n = 141) had stable angina. De novo lesions and in-stent restenosis accounted for 79% and 21% of cases, respectively. Intravascular imaging was used in 33% (n = 90) of patients. An upfront IVL strategy was adopted in 34% (n = 92), while the rest were bailout procedures. Adjuvant rotational atherectomy ("RotaTripsy") was required in 11% (n = 31) of cases. The procedural success was 99%. During a median follow-up of 687 days (interquartile range: 549-787), cardiac death occurred in 5% (n = 14), TVMI in 3% (n = 8), TLR in 6% (n = 16), and MACE rate was 11% (n = 30). CONCLUSION: This is the largest multicenter registry with a long-term follow-up showing the remarkably high procedural success of IVL use in calcified coronary lesions with low rates of hard endpoints and MACE.

9.
Catheter Cardiovasc Interv ; 99(3): 664-673, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34582631

RESUMO

OBJECTIVES: to test the safety and efficacy of intravascular imaging and specifically optical coherence tomography (OCT) as a diagnostic tool for left main angioplasty and analyze the mid-term outcome accordingly. BACKGROUND: Clinical data and international guidelines recommend the use of intravascular imaging ultrasound (IVUS) to guide left main (LM) angioplasty. Despite early experience using OCT in this setting is encouraging, the evidence supporting its use is still limited. METHODS: ROCK II is a multicenter, investigator-driven, retrospective European study to compare the performance of IVUS and OCT versus angiography in patients undergoing distal-LM stenting. The primary study endpoint was target-lesion failure (TLF) including cardiac death, target-vessel myocardial infarction and target-lesion revascularization. We designed this study hypothesizing the superiority of intravascular imaging over angiographic guidance alone, and the non-inferiority of OCT versus IVUS. RESULTS: A total of 730 patients, 377 with intravascular-imaging guidance (162 OCT, 215 IVUS) and 353 with angiographic guidance, were analyzed. The one-year rate of TLF was 21.2% with angiography and 12.7% with intravascular-imaging (p = 0.039), with no difference between OCT and IVUS (p = 0.26). Intravascular-imaging was predictor of freedom from TLF (HR 0.46; 95% CI 0.23-0.93: p = 0.03). Propensity-score matching identified three groups of 100 patients each with no significant differences in baseline characteristics. The one-year rate of TLF was 16% in the angiographic, 7% in the OCT and 6% in the IVUS group, respectively (p = 0.03 for IVUS or OCT vs. angiography). No between-group significant differences in the rate of individual components of TLF were found. CONCLUSIONS: Intravascular imaging was superior to angiography for distal LM stenting, with no difference between OCT and IVUS.


Assuntos
Doença da Artéria Coronariana , Intervenção Coronária Percutânea , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/patologia , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/métodos , Estudos Retrospectivos , Tomografia de Coerência Óptica/métodos , Resultado do Tratamento , Ultrassonografia de Intervenção/métodos
10.
Rev Cardiovasc Med ; 22(4): 1421-1428, 2021 Dec 22.
Artigo em Inglês | MEDLINE | ID: mdl-34957782

RESUMO

Coronary bifurcation lesion (CBL) is a common but challenging scenario in percutaneous coronary interventions. Drug-coated balloons (DCBs) are modern devices with attractive perspective in CBL treatment. In-stent restenosis, small vessel and diffuse de-novo coronary artery disease have been, so far, considered the ideal scenario for DCBs application. Studies assessing DCBs in de-novo CBL demonstrated the safety and efficacy of this strategy. However, the heterogeneity of the study populations and the presence of methodological limitations prevent from drawing definite recommendations. Considering that the best treatment of bifurcations has not yet been defined, the "leaving nothing behind" philosophy will be the topic of future studies.


Assuntos
Angioplastia Coronária com Balão , Doença da Artéria Coronariana , Reestenose Coronária , Intervenção Coronária Percutânea , Angioplastia Coronária com Balão/efeitos adversos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Resultado do Tratamento
11.
Catheter Cardiovasc Interv ; 98(2): 225-235, 2021 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-32936532

RESUMO

BACKGROUND: The recently introduced intravascular lithotripsy (IVL) appears promising and relatively safer than conventional approaches when dealing with calcified lesions. Although there are published reports on this novel technology, data from the real world are limited. In this study, we aim to report on the experience of IVL from a real-world population derived from six European centers that undertake high-volume complex coronary interventions. METHODS AND RESULTS: We enrolled all patients treated with IVL between November 2018 and February 2020 at six centers. Procedural success and complications were assessed along with clinical outcomes, which included: cardiac death, target vessel myocardial infarction (TVMI), target lesion revascularisation (TLR), and major adverse cardiac event (MACE) (composite of cardiac death, TVMI, and TLR). Hundred and ninety patients (200 lesions) with a mean age of 72 years were treated using IVL. Diabetes and chronic kidney disease were present in 50% (n = 95) and 16% (n = 30) of cases, respectively. Acute-coronary syndromes accounted for 91 (48%) of the cases. Most were de-novo lesions (77%; n = 154). Upfront use of IVL occurred in 26% of cases, while the rest were bail-out procedures due to inadequate predilatation with conventional balloons. Adjuvant rotational atherectomy was needed in 17% of cases. Procedural success was achieved in 99% of cases with a complication rate of 3%. During the median follow-up of 222 days, there was two cardiac deaths (1%), one case of TVMI (0.5%), 3 TLR (1.5%) taking the MACE rate to 2.6%. CONCLUSION: Use of IVL appears to be safe and effective in dealing with calcified-coronary lesions. A high success rate was observed with low procedural complications and event rates.


Assuntos
Aterectomia Coronária , Doença da Artéria Coronariana , Litotripsia , Calcificação Vascular , Idoso , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Humanos , Litotripsia/efeitos adversos , Stents , Resultado do Tratamento , Calcificação Vascular/diagnóstico por imagem , Calcificação Vascular/terapia
12.
Catheter Cardiovasc Interv ; 98(6): E862-E869, 2021 11 15.
Artigo em Inglês | MEDLINE | ID: mdl-33961729

RESUMO

OBJECTIVES: To evaluate the use and outcomes of percutaneous mechanical circulatory support (pMCS) utilized during transcatheter aortic valve implantation (TAVI) from high-volume centers. METHODS AND RESULTS: Our international multicenter registry including 13 high-volume TAVI centers with 87 patients (76.5 ± 11.8 years, 63.2% men) who underwent TAVI for severe aortic stenosis and required pMCS (75.9% VA-ECMO, 19.5% Impella CP, 4.6% TandemHeart) during the procedure (prior to TAVI 39.1%, emergent rescue 50.6%, following TAVI 10.3%). The procedures were considered high-risk, with 50.6% having severe left ventricular dysfunction, 24.1% biventricular dysfunction, and 32.2% severe pulmonary hypertension. In-hospital and 1-year mortality were 27.5% and 49.4%, respectively. Patients with prophylactic hemodynamic support had lower periprocedural mortality compared to patients with rescue insertion of pMCS (log rank = 0.013) and patients who did not undergo cardiopulmonary resuscitation during the TAVI procedure had better short and long term survival (log rank <0.001 and 0.015, respectively). CONCLUSIONS: Given the overall survival rate and low frequency of pMCS-related complications, our study results support the use of pMCS prophylactically or during the course of TAVI (bailout) in order to improve clinical outcomes in high-risk procedures or in case of acute life-threatening hemodynamic collapse.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Feminino , Humanos , Masculino , Sistema de Registros , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
13.
Catheter Cardiovasc Interv ; 97(3): 411-420, 2021 02 15.
Artigo em Inglês | MEDLINE | ID: mdl-32198845

RESUMO

OBJECTIVES: We aimed to evaluate the use of bare metal stent (BMS) implantation in current percutaneous coronary intervention (PCI) era, focusing on indications for use and clinical outcomes. BACKGROUND: Limited data on BMS usage in current clinical practice are available. METHODS: All patients who underwent PCI with at least one BMS implantation in 18 Italian centers from January 1, 2013 to December 31, 2017, were included in our registry. Rates of BMS use and reasons for BMS implantations were reported for the overall study period and for each year. Primary outcomes were mortality, bleeding (Bleeding Academic Research Consortium-BARC and Thrombolysis in Myocardial Infarction-TIMI non-CABG definitions), and major adverse cardiac events (MACE) defined as the composite of all-cause and cardiac death, any myocardial infarction, target vessel revascularization, or any stent thrombosis. RESULTS: Among 58,879 patients undergoing PCI in the study period, 2,117 (3.6%) patients (mean age 73 years, 69.7% males, 73.3% acute coronary syndrome) were treated with BMS implantation (2,353 treated lesions). The rate of BMS implantation progressively decreased from 10.1% (2013) to 0.3% (2017). Main reasons for BMS implantation were: ST-elevation myocardial infarction (STEMI) (23.1%), advanced age (24.4%), and physician's perception of high-bleeding risk (34.0%). At a mean follow-up of 2.2 ± 1.5 years, all-cause and cardiac mortality were 25.6 and 12.7%, respectively; MACE rate was 35.3%, any bleeding rate was 13.0% (BARC 3-5 bleeding 6.3%, TIMI non-CABG major bleeding 6.1%). CONCLUSION: In a large, contemporary, real-world, multicenter registry, BMS use progressively reduced over the last 5 years. Main reasons for BMS implantation were STEMI, advanced age, and physician's perception of high-bleeding risk. High rates of mortality and MACE were observed in this real-world high-risk population.


Assuntos
Stents Farmacológicos , Intervenção Coronária Percutânea , Feminino , Humanos , Itália , Masculino , Intervenção Coronária Percutânea/efeitos adversos , Sistema de Registros , Stents , Resultado do Tratamento
14.
Heart Lung Circ ; 30(9): 1397-1405, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33812787

RESUMO

BACKGROUND: The success rate of coronary angiography (CA) after transcatheter aortic valve implantation (TAVI) is variable. Our aim was to investigate CA difficulty, outcomes, and predictors of difficult CA after TAVI. METHOD: This was an international multicentric retrospective cohort study that included patients with TAVI and subsequent CA between January 2010 and December 2019. Difficulty with CA was graded as 1 (normal), 2 (partial engagement, complete vessel opacification), 3 (partial engagement, incomplete vessel opacification), and 4 (unsuccessful angiography). Patients were grouped as (a) "easy" (grade 1 for left and right) or (b) "difficult" (grade >1 for either). We compared baseline characteristics and outcomes, and performed multivariate logistic regression for predictors of difficult CA. RESULTS: Of 96 patients included (mean age 77.4±8.7 years, 48 [50%] male), 88 (92%) had successful CA. Right CA was successful in 80 (83%) patients and left CA in 91 (95%) (p<0.0001). The "difficult" group (n=41 [43%]) had higher Society of Thoracic Surgery (STS) scores (7.6±4.9 vs 5.4±4.0; p=0.022), smaller annulus perimeters (72.4±5.4 mm vs 76.2±9.4 mm; p=0.049), greater use of self-expanding valves (83% vs 18%; p<0.0001), increased valve size (26.8±2.1 mm vs 25.6±3.0 mm; p=0.032), and increased oversizing for area (44.3%±17.4% vs 23.6%±22.0%; p=0.0002) and perimeter (17.5%±8.2% vs 7.1%±10.8%; p<0.0001). There was no difference in outcomes except for increased major bleeding (7.3% vs 0.0%; p=0.042). The strongest predictor for "difficult" CA was self-expanding valves when compared to balloon-expandable valves (adjusted odds ratio [aOR], 15.23; 95% confidence interval [CI], 2.27-102.40). Society of Thoracic Surgery score was borderline predictive (aOR, 1.26; 95% CI, 1.04-1.52). CONCLUSIONS: Our results show that after TAVI, CA success rate is high, right CA is more difficult than left, self-expanding valves predispose to difficult CA, and STS score weakly predicts difficult CA. This study is hypothesis-generating and more research is required to confirm these findings.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Idoso , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Cateterismo Cardíaco , Humanos , Masculino , Desenho de Prótese , Estudos Retrospectivos , Resultado do Tratamento
15.
Catheter Cardiovasc Interv ; 96(3): E248-E256, 2020 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-32012453

RESUMO

BACKGROUND: A large trial established the favorable profile of a new polymer-free biolimus A9-eluting stent (PF-BES) with a 1-month dual antiplatelet therapy (DAPT) in high bleeding risk (HBR) patients. This is the first study comparing outcomes for a 1-month versus longer DAPT strategies following PF-BES-percutaneous coronary intervention (PCI). METHODS: All patients undergoing PF-BES-PCI (January 2016 to July 2018) were included in the multicenter CHANCE registry. Patients were stratified according to DAPT strategy at discharge (planned 1-month vs. planned >1-month). Primary outcomes were the 390-day estimates of a patient-oriented and of a device-oriented composite endpoints (POCE: death, myocardial infarction [MI] or target vessel revascularization; DOCE: cardiac death, target vessel-MI or ischemia-driven target lesion revascularization). Landmark analyses from 1-month post-PCI were carried. RESULTS: Following PF-BES-PCI, 328(40.3%) and 485(59.6%) patients were discharged with 1-month and longer DAPT (12 months [6-12]), respectively. Patients with a previous or index MI were less likely to be discharged on 1-month DAPT. Patients prescribed with 1-month DAPT were more likely to be at HBR than those with longer DAPT (90.2% vs. 69.9%, p = .001). No between-groups differences in the primary outcomes (planned 1-month vs. planned >1-month DAPT: POCE 11.9% vs. 13.2%, p = .747; DOCE: 4.8% vs. 8.1%, p = .500) were observed, also after adjusting for confoundings (POCE: adjusted-hazard ratio [adj-HR] 1.26, 95%CI 0.74-2.13; DOCE: adj-HR 1.00, 95%CI 0.49-1.99). Landmark analyses showed similar results. CONCLUSIONS: In a large all-comers registry of PF-BES PCI, no interaction of planned DAPT strategy (1-month vs. >1-month) with outcomes was found. This observation warrants investigation in adequately powered randomized studies (ClinicalTrials.gov NCT03622203).


Assuntos
Fármacos Cardiovasculares/administração & dosagem , Doença da Artéria Coronariana/terapia , Stents Farmacológicos , Terapia Antiplaquetária Dupla , Intervenção Coronária Percutânea/instrumentação , Inibidores da Agregação Plaquetária/administração & dosagem , Sirolimo/análogos & derivados , Idoso , Idoso de 80 Anos ou mais , Fármacos Cardiovasculares/efeitos adversos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Esquema de Medicação , Terapia Antiplaquetária Dupla/efeitos adversos , Terapia Antiplaquetária Dupla/mortalidade , Feminino , Humanos , Itália , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Inibidores da Agregação Plaquetária/efeitos adversos , Desenho de Prótese , Sistema de Registros , Sirolimo/administração & dosagem , Sirolimo/efeitos adversos , Fatores de Tempo , Resultado do Tratamento
16.
Catheter Cardiovasc Interv ; 96(2): 255-265, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-31905259

RESUMO

BACKGROUND: The ULISSE registry evaluated the real-world performance of the Ultimaster® biodegradable polymer sirolimus-eluting stent (BP-SES) in a multicenter-independent cohort of patients undergoing percutaneous coronary intervention, including a large proportion of diabetes mellitus (DM) patients. METHODS: In this subgroup analysis, 1,660 consecutive patients, 2,422 lesions, treated with BP-SES enrolled in the ULISSE registry were divided in two groups: DM (485 patients, 728 lesions) and non-DM (1,175 patients, 1,694 lesions). Primary endpoint was target lesion failure (TLF), a composite endpoint of cardiac-death, target-vessel myocardial infarction (TV-MI), and clinically driven target lesion revascularization (TLR) at 1-year. Secondary endpoint was TLR at 1-year. RESULTS: At 1-year follow-up TLF occurred in 5% overall patients and was significantly higher in DM patients (8 vs. 3.7%; p = .001), due to more cardiac deaths (3.4 vs. 1.1%; p = .002). TLR occurred in 3.2% overall patients, and it was not significantly higher in DM compared to non-DM patients (4.4 vs. 2.8%; p = .114). The incidence of stent thrombosis was low and similar between groups (0.4 vs. 0.9%; p = .526). Insulin-treated DM (ITDM) patients showed higher rate of TLF as compared to non-ITDM patients (13 vs. 6.5%; p = .041), but similar rate of TLR (6 vs. 4%; p = .405). After adjustment for relevant comorbidities, DM was not significantly associated with TLF or cardiac death in patients undergoing BP-SES implantation. CONCLUSIONS: This study is the first all-comers evaluation of BP-SES in DM patients. Our findings show that DM patients, mostly those with ITDM, still represent a vulnerable population and experience significantly higher rate of TLF. Overall BP-SES efficacy is considerable, although not statistically significant higher rate of TLR is still present in DM compared to non-DM patients.


Assuntos
Implantes Absorvíveis , Fármacos Cardiovasculares/administração & dosagem , Doença da Artéria Coronariana/terapia , Diabetes Mellitus , Stents Farmacológicos , Intervenção Coronária Percutânea/instrumentação , Sirolimo/administração & dosagem , Idoso , Fármacos Cardiovasculares/efeitos adversos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Diabetes Mellitus/diagnóstico , Diabetes Mellitus/mortalidade , Feminino , Humanos , Itália , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Estudos Prospectivos , Desenho de Prótese , Sistema de Registros , Medição de Risco , Fatores de Risco , Sirolimo/efeitos adversos , Fatores de Tempo , Resultado do Tratamento
17.
Catheter Cardiovasc Interv ; 95(3): 522-529, 2020 02 15.
Artigo em Inglês | MEDLINE | ID: mdl-31385427

RESUMO

OBJECTIVES: Evaluate safety and efficacy of polymer-free biolimus-eluting stents (PF-BESs) versus ultrathin stents in unprotected left main (ULM) or bifurcation. BACKGROUND: PF-BESs due to reduced length of dual antiplatelet therapy (DAPT) are increasingly used. However, there are limited data about safety and efficacy for ULM or bifurcation. METHODS: We selected all-patients treated for ULM or bifurcation from two multicenter real life registries (RAIN [NCT03544294] evaluating ultrathin stents, CHANCE [NCT03622203] appraising PF-BES). After propensity score with matching, the primary endpoint was major adverse cardiac events (MACE; a composite of all-cause death, myocardial infarction, target lesion revascularization [TLR], and stent thrombosis [ST]), while its components along with target vessel revascularization (TVR) secondary endpoints. RESULTS: Three thousand and three patients treated with ultrathin stents and 446 with PF-BESs, resulting respectively in 562 and 281 after propensity score with matching (33 and 22%, respectively, with ULM disease). After 12 (8-20) months, rates of MACE were similar (9 vs. 8%, p = 0.56) without difference in TLR and ST (3.0 vs. 1.7%, p = .19 and 1.8 vs. 1.1%, p = .42). These results were consistent for ULM group (3 vs. 1.7% and 1.8 vs. 1.1%, p = .49 and .76), for non-ULM group (2.1 vs. 3.4%, p = .56 and 1.2 vs. 1.7%, p = .78) and for two-stent strategy (8.7 vs. 4.5% and 4.3 vs. 3.2%, p = .75 and .91). Among patients treated with 1 month of DAPT in both groups, those with ultrathin stents experienced higher rates of MACE related to all-cause death (22 vs. 12%, p = .04) with higher although not significant rates of ST (3 vs. 0%, p = .45). CONCLUSIONS: PF-BES implanted on ULM or BiF offered freedom from TLR and ST comparable to ultrathin stents. PF-BESs patients assuming DAPT for 1 month experienced a lower despite not significant incidence of ST.


Assuntos
Fármacos Cardiovasculares/administração & dosagem , Doença da Artéria Coronariana/terapia , Stents Farmacológicos , Intervenção Coronária Percutânea/instrumentação , Sirolimo/análogos & derivados , Idoso , Idoso de 80 Anos ou mais , Fármacos Cardiovasculares/efeitos adversos , Protocolos Clínicos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Doença da Artéria Coronariana/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Pontuação de Propensão , Desenho de Prótese , Sistema de Registros , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Sirolimo/administração & dosagem , Sirolimo/efeitos adversos , Fatores de Tempo
18.
Catheter Cardiovasc Interv ; 93(3): 404-410, 2019 02 15.
Artigo em Inglês | MEDLINE | ID: mdl-30346080

RESUMO

OBJECTIVES: To report 1-year clinical outcomes of bioresorbable vascular scaffold (BVS) in acute coronary syndromes (ACS) population. BACKGROUND: BVS use has rapidly extended to high-risk patients as those presenting with ACS. To date limited data have been reported on BVS performance in ACS patients. METHODS: RAI is a multicenter, prospective registry that included 1,505 patients treated with at least 1 successful BVS implantation. A subgroup analysis on ACS patients was performed and the 1-year outcomes of this cohort compared to the remaining stable coronary artery disease (SCAD) population are reported here. Coprimary endpoints were target-lesion revascularization (TLR) and scaffold thrombosis (ScT) at 1-year follow-up. RESULTS: Fifty-nine percent of the patients presented with ACS, of whom 36.5% with ST-elevation myocardial infarctions. ACS patients were significantly younger, with a better cardiovascular risk profile, a lower rate of multivessel disease, chronic total occlusion or in-stent restenosis and a lower Syntax score. Predilation and postdilation were performed in 97.4% and in 96.5% of cases, respectively. No differences were noted in terms of TIMI 3 final flow, but acute gain was greater in ACS compared to SCAD group (P < 0.001). At one-year follow-up no differences were found in terms of TLR (3.3% vs. 3.3%, P = 0.98), and device-oriented composite end-point (4.3% vs. 3.4%, P = 0.4) between ACS and SCAD groups. The rate of definite/probable ScT was numerically higher in ACS vs. stable CAD patients (1.3% vs. 0.8%, P = 0.2). CONCLUSIONS: Our data suggest that the use of BVS in ACS patients is associated with a numerically higher rate of ScT compared to SCAD population numerically higher, but without statistical significance.


Assuntos
Implantes Absorvíveis , Síndrome Coronariana Aguda/terapia , Angina Instável/terapia , Angioplastia Coronária com Balão/instrumentação , Infarto do Miocárdio sem Supradesnível do Segmento ST/terapia , Infarto do Miocárdio com Supradesnível do Segmento ST/terapia , Síndrome Coronariana Aguda/diagnóstico por imagem , Síndrome Coronariana Aguda/mortalidade , Idoso , Angina Instável/diagnóstico por imagem , Angina Instável/mortalidade , Angioplastia Coronária com Balão/efeitos adversos , Angioplastia Coronária com Balão/mortalidade , Trombose Coronária/mortalidade , Feminino , Humanos , Itália , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio sem Supradesnível do Segmento ST/diagnóstico por imagem , Infarto do Miocárdio sem Supradesnível do Segmento ST/mortalidade , Estudos Prospectivos , Desenho de Prótese , Sistema de Registros , Fatores de Risco , Infarto do Miocárdio com Supradesnível do Segmento ST/diagnóstico por imagem , Infarto do Miocárdio com Supradesnível do Segmento ST/mortalidade , Fatores de Tempo , Resultado do Tratamento
19.
Catheter Cardiovasc Interv ; 94(7): 972-979, 2019 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-31037840

RESUMO

BACKGROUND: The ULISSE registry has demonstrated the real-world performance of the Ultimaster biodegradable polymer sirolimus-eluting stent (BP-SES) in a large cohort of patients undergoing percutaneous coronary intervention, including a large proportion of patients presenting with acute myocardial infarction (AMI). METHODS: We performed a subgroup analysis of the ULISSE registry in AMI patients and compared the outcomes of this vulnerable cohort with that of patients presenting without AMI (non-AMI). The primary end point was the incidence of 1-year target lesion failure (TLF), a composite of cardiac death, target vessel myocardial infarction (TV-MI), and clinically indicated target lesion revascularization (TLR). RESULTS: Of 1,660 patients included in the ULISSE registry, 381(23%) presented with AMI, 207(54.3%) non-ST elevation myocardial infarction, and 174(45.7%) ST-elevation myocardial infarction. Compared with non-AMI patients, those with AMI were more frequently female and smokers, with lower left ventricular ejection fraction (LVEF) and chronic kidney disease requiring dialysis. At 1 year, TLF rate was significantly higher in AMI than non-AMI patients (7.9 vs. 4.1%; HR 1.98, CI 95% 1.22-3.23; p = .005) driven by higher rate of cardiac death (4.0 vs. 1.1%; HR 3.59, CI 95% 1.64-7.88; p = .01) and TV-MI (2.8 vs 0.9%; HR 2.99,CI 95% 1.22-7.37; p = .01), without differences in TLR rate (4.3 vs. 2.9%,HR 0.66, CI95% 0.35-1.25; p = .2). At multivariate Cox regression analysis, eGFR <40 mL/min (HR: 2.868) and LVEF <40% (HR: 2.394) were the only independent predictors of TLF. CONCLUSIONS: In AMI patients, Ultimaster BP-SES implantation was associated with higher rate of TLF and definite stent thrombosis compared with non-AMI patients. The high incidence of adverse events was mainly driven by the unfavorable baseline risk profile.


Assuntos
Implantes Absorvíveis , Fármacos Cardiovasculares/administração & dosagem , Doença da Artéria Coronariana/terapia , Stents Farmacológicos , Infarto do Miocárdio/terapia , Intervenção Coronária Percutânea/instrumentação , Polímeros/química , Sirolimo/administração & dosagem , Idoso , Fármacos Cardiovasculares/efeitos adversos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Trombose Coronária/etiologia , Feminino , Humanos , Itália , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/diagnóstico por imagem , Infarto do Miocárdio/mortalidade , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Intervalo Livre de Progressão , Desenho de Prótese , Recidiva , Sistema de Registros , Estudos Retrospectivos , Fatores de Risco , Sirolimo/efeitos adversos , Fatores de Tempo
20.
Cardiology ; 142(2): 93-96, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31079093

RESUMO

To date, very little is known about the performance of a sirolimus-eluting bioresorbable magnesium scaffold (Mg-BRS) in patients with acute myocardial infarction (AMI). A multicenter cohort analysis was performed on 69 consecutive AMI subjects treated with Mg-BRS. Procedural success was obtained in all cases, and no in-hospital events were reported. At 9-month follow-up, no cardiac death, target-vessel myocardial infarction, ischemia-driven target lesion revascularization, or Mg-BRS thrombosis was reported. Although our analysis showed encouraging results, larger studies and longer-term follow-up are needed to better understand the potential benefits associated with the use of a Mg-BRS in AMI patients.


Assuntos
Implantes Absorvíveis , Stents Farmacológicos , Magnésio/administração & dosagem , Infarto do Miocárdio/cirurgia , Sirolimo/administração & dosagem , Doença Aguda , Idoso , Seguimentos , Humanos , Itália , Pessoa de Meia-Idade , Intervenção Coronária Percutânea , Desenho de Prótese , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA